Loading...
HomeMy WebLinkAboutOWTS Permit Garfield County Public Health 2014 Blake Ave. Glenwood Springs, CO 81601 Phone: (970) 945-6614 ext. 8150 For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable. Project Address: 387 Meadow Lane Glenwood Springs Parcel No.: 218535483028 Owner Name: David and Dorothy Bleakley Owner Phone: (970) 274-2710 Designer: CBO Designer Phone: (970) 309-5259 Number of Bedrooms _4__Minimum Tank Capacity __1,250_gal__Minimum Absorption _656.25 ft 2 OWTS PERMIT KEEP AVAILABLE AT PROJECT SITE Permit Number _SEPT-8649_ Permit Type X New X Repair X Remodel/addition X Tank only Issue Date 05/21/2024 Expiration Date 05/21/2025 Permit Conditions: This OWTS Permit is approved on the condition of compliance with the design as submitted by CBO dated April 29, 2024. Changes must be approved by Garfield County Public Health and the designer prior to construction. The new OWTS will serve an existing 4-bedroom residence that is currently on the site. The existing OWTS will be abandoned in place. The new system will consist of a new, two-compartment minimum 1,500-gallon septic tank set level with access to grade, with a high-head pump in the second compartment. Effluent will be pumped to an automatic distributing valve set at the high point of the system that will distribute effluent to 660 ft2 of STA. The STA will consist of two GeoMat beds 10-feet wide by 33-feet long placed on a minimum of 3 feet of secondary sand media with four- feet between each bed. Laterals will consist of 1.5-inch diameter Schedule 40 PVC with 5/32-inch orifice holes spaced 2.5-feet on-center (O.C.) and ending in a sweeping ell with flush valves. Inspection ports are to be installed at each corner of each bed. Maintain all setbacks and elevations as designed. To assist in scheduling, please contact Garfield County Public Health (970-945-6614 ext. 8150) to notify the start of OWTS construction. Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final inspection of the installed system prior to backfill. NO OWTS COMPONENT SHALL BE BACKFILLED WITHOUT PRIOR APPROVAL FROM GARFIELD COUNTY PUBLIC HEALTH AND THE DESIGNER. Agreement All installations must comply with all requirements of the Garfield County OWTS regulations including but not limited to the conditions specified above. In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location, construction and erection of the proposed OWTS and associated structures for which this permit is granted. The applicant further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described OWTS and structure, the permit may then be revoked by notice from the Health Department and immediately become null and void. The issuance of a permit and specifications of terms and conditions therein will not constitute assumption of liability, nor create presumption that the local public health agency or its employees may be liable for the failure or malfunctioning of any system. Permit issuance will not constitute a certification that the system, the equipment used in the system, or any component used for system operation will ensure continuous compliance with the provision of the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit. Permit Approval Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as-built" drawing must be submitted and inspection of the system must be completed by GCPH before final approval of the system will be issued. 05/21/2024 Issued By: Garfield County Environmental Health Department Date