HomeMy WebLinkAboutInsulation CertificateEnergyPro Insulation, Inc.
PO Box 2006, Grand Junction, CO 81502 Office 970-623-7327
Certificate of Insulation
The undersigned certifies that the listed insulation products have been installed in
accordance with the manufacturer's recommended applications for these Products
R-Value
Material
Work Area
Notes
R-49
Loose -fill Fiberglass
Ceiling Area
Cardboard baffles installed into every truss bay at
eaves for attic ventilation.
R-49
Unfaced Fiberglass
Ceiling Area
Installed to non-blowable ceiling areas.
Batts
R-21
Unfaced Fiberglass
Exterior Walls
Installed to exterior walls of house.
Batt
R-21
Kraft Faced Fiberglass
Exterior Walls
Installed to Garage / House Common Wall
Batt
R-19
Unfaced Fiberglass
Garage Ext. Walls
Installed to the 2X6 framed walls
Batt
R-13
Unfaced Fiberglass
Garage Ext. Walls
Installed to the 2X4 framed walls
Batt
R-38
Loose -fill Fiberglass
Garage Ceiling
Cardboard baffles installed into every other truss bay
Area
at eaves for attic ventilation. Unfaced batt installed at
non-blowable ceilings. Install baffles at storage
area to keep blow off storage deck.
R-21
Unfaced Fiberglass
Kneewalls
FSK paper installed on the backside as an air barrier.
Batts
Air Infiltration
Foam Gasket, Gun
Gaps and Cracks
Foam all horizontal and vertical penetrations. Install
Foam & Caulk
gasket at all top plate. Caulk bottom plate, stud
acks, and misc. gaps.
Air Infiltration
4 mil Poly
Exterior Walls &
Ceilings
Air Infiltration
Fire Foam
Penetrations Per
Fire rated foam installed into electrical & plumbing
Code
penetrations per code. Includes low expanding foam
to all windows & doors.
Air Infiltration
Gun Foam & Caulk
Air Sealing
After drywall caulk and foam electrical and plumbing
enetrations.
R-19
Unfaced Fiberglass
Crawl Space Walls
Mechanically fastened in place.
Batts
Job Address: 159 Blue Heron Dr. (Lot 57)
Glenwood Springs, CO 81601
Trent McComb 1>4e
President
EnergyPro Insulation, Inc.
Page 1 of I