HomeMy WebLinkAboutConditions of PermitCONDITION OF PERMIT
BLRE-04-24-8632
JOHN & MARLISSA WESTERFIELD
New Single-family dwelling w/ attached garage
15 Horseshoe Ln, Carbondale
Aspen Glen, FLG 7, H17
1) ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE (I.R.C.)AND 2018
I NTERNATIONAL EN ERGY CONSERVATION CODE (I. E.C.C.)
2) pROPOSED TMPROVEMENTS ARE SUBJECT TO ALL APPLTCABLE lTEl\4S CONTAINED lN THE
ATTACHED "GARFIELD COUNTY BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON
PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) ELECTRTCAL PERN/tTTtNG AND TNSPECTIONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL
ROUGH.IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS
REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.
4) ALL EXTERIOR LIGHTING TO BE DOWNCASTAND SHIELDED.
5) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLY WITH WILDFIRE MITIGATION AND
DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE
DISTRICT. PLEASE REFER TO THE GARFIELD COUNry COMMUNITY DEVELOPMENT WEBSITE FOR
ADDITIONAL I N FORMATION.
6) OPEN HOLE SOTLS REPORT tS REOUTRED AT FOOTTNG TNSPECTION AND PRIOR TO ANY CONCRETE
POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE BUILDING INSPECTOR.
1,500 PSF soil bearing.
7) PRE-ENGTNEERED ROOF TRUSSES. HAVE ENGTNEERTNG FOR BUILDING INSPECTOR AT TIME OF
FRAME INSPECTION.
8) BLOWER DOOR TEST tS REOUtRED. MUST SUBMIT BLOWER DOOR TEST REPORT TO GARFIELD
COUNTY COMMUNIry DEVELOPMENT DEPT. OFFICE PRIOR TO SCHEDULING FINAL BUILDING
INSPECTION / C.O. FINAL.
9) A LOT TMPROVEMENT CERT|FtCATE, SEALED BY A COLORADO LICENSED SURVEYOR, lS REOUIRED AT
FOUNDATION INSPECTION TO VERIFY STRUCTURE IS IN COMPLIANCE WITH MINIMUM SETBACK
REOUIREMENTS / BUILDING ENVELOPE.
10) AN ELEVATTON SURVEY, SEALED BY A COLORADO PROFESSTONAL LTCENSED SURVEYOR, lS
REOUIRED AT FRAME INSPECTION TO VERIFY THAT AS-BUILT ROOFS COMPLY WITH GARFIELD
COUNTY'S 25-FOOT BUILDING HEIGHT LIMIT AS DEFINED IN THE LAND USE DEVELOPMENT CODE.
1 1) PRESCR|pTtVE PATH USrNG 2018 tECC TABLE R402.1.2 HAS BEEN CHOSEN FOR ENERGY
COMPLIANCE OF THIS HOME DESIGN. MANUAL J REPORT ALSO ATTACHED FOR REFERENCE.
ALL NEW HOMES TO HAVE WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM INSTALLED (2015
IRC TABLE m1507.3.3(1)AND (2) SHOWN ON COVER SHEET. (NO ERV, EXHAUST ONLY SYSTEM
I NSTALLED PER ARCHITECT).