HomeMy WebLinkAboutResCheck Compliance CertificateGenerated by REScheck-Weh Software
Com pl ia nce Certificate
Project MONICO
Energy Code:
Location:
Construction Type:
Project Type:
Conditioned Floor Area
Glazing Area
Climate Zone:
Permit Date:
Permit Number:
All Electric
ls Renewable
Has Charger
Has Battery:
Has Heat Pump:
20x8 tEcc
Rifle, Colorado
Single-family
New Construction
3,166 ft2
LOo/o
s (6881 HDD)
false
false
false
false
false
Construction Site Owner/Agent:Desig ner/Contractor:
Compliance: 1.970 BetterThan Code Maximum UA: 315 Your UA: 3O9
The % Better or Worse Than Code lndex reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Slah-*n-graele trade*ffs are no lcnger c*nsiderecl ifi the U.A cr p*rf*rmance ccrnpli*nce peth ift RE$check. fiach Et*b-on-#rade
assembiy in the specified c{imat* aone milst meet th* mininnum energy code insulaticn R-value and depth requir*m*nls.
Envelope Assemblies
a\l
$
$
Ceiling: Raised or Energy Truss
Wall north: Wood Frame, i.6" o.c.
Door: Glass Door (over 50% glazing)
Window: Vinyl Frame
Wall south: Wood Frame, L6" o.c.
Door 1: Solid Door (under 50% glazing)
Window 1.:Vinyl Frame
Wall east: Wood Frame, 16" o.c.
Window 2: Vinyl Frame
Wall west: Wood Frame, 1.6" o.c.
r,952
536
4L
53
485
101
44
420
10
62r
0.020
0.060
0.270
0.270
0.060
0.270
0.270
0,060
0.270
0.060
0.026
0,060
0,300
0.300
0.060
0.300
0.300
0,060
0.300
0.060
39
27
11
L4
20
27
t2
25
3
32
5L
27
!2
16
20
30
13
25
3
32
49,0
19.0
19.0
19.0
0.0
0,0
0.0
0,0
0.0
Co,m,plia'nce: Fasses using IJA trade-cff
Gross Area
(}r
Perimeter
Cont. Prap. Req,
R-Value U-Factor U-FactorAssemblyR-Value
Cavity
UA UA
Prop. Req,
r.9.0
Project Title: MONICO
Data filename:
Report date: 04116124
Page 1 of 2
CavitYt
R-Value
Cont. Prop, Req.
R-Value U-Factor U-Factor
Prop,
UA
Gross Area
Perimeter
Reg.orAssembly UA
Door 2: Solid Door (under 50% glazing)
Window 3: Vinyl Frame
Wall lower east: Wood Frame, 16" o.c.
Floor: Slab-On-Grade (Unheated)
lnsulation depth: 3.0'
lnsulation position: Fully lnsulated (uniform R-value
across perimeter and under slab)
Basement Wall: Solid Concrete or Masonry
Wall height: 10.0'
Depth betow grade: 8.0'
lnsulation depth: 10.0'
Basement Wall L west: Solid Concrete or Masonry
Wall height: 3.5'
Depth below grade: 3.0'
lnsulation depth: 3.5'
28
64
93
138
969
105
8
L7
6
I
19
619.0 0,0
72.O
12.0
0.274
0.270
0.060
0,300
0,300
0.060
L2.0 0.336 0.360 0 0
0.0 0.062 0.050 60 48
50.0 0.073 0.050 8
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications,.and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2018 IECC requirements in
REscheckVersion : REScheck-Web and to comply with the mandatory requirements listed in the REScheck lnspection Checklist.
Name - Title Dates
Project Title: MONICO
Data filename:
Report date: 04116124
Page? of 2
2018 IECC Energy
Effi ciency Ce rtificate
Above-Grade Wall
Below-Grade Wall
Floor
Ceiling / Roof
Ductwork (unconditioned spaces):
Window
Door
Heating Syste
Cooling Syste
Water Heaterr_
Name:
Comments
19.OO
12.OO
12.0O
49.00
o.27
o.27
Date:
l,nsul*tion Ra ing R-Val,ue
Glnss & Deor Rating U-Facter sl{GC
Heating & Cooling Eq,uiprne*t Efficie.ncy