Loading...
HomeMy WebLinkAboutResCheck Compliance CertificateGenerated by REScheck-Weh Software Com pl ia nce Certificate Project MONICO Energy Code: Location: Construction Type: Project Type: Conditioned Floor Area Glazing Area Climate Zone: Permit Date: Permit Number: All Electric ls Renewable Has Charger Has Battery: Has Heat Pump: 20x8 tEcc Rifle, Colorado Single-family New Construction 3,166 ft2 LOo/o s (6881 HDD) false false false false false Construction Site Owner/Agent:Desig ner/Contractor: Compliance: 1.970 BetterThan Code Maximum UA: 315 Your UA: 3O9 The % Better or Worse Than Code lndex reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Slah-*n-graele trade*ffs are no lcnger c*nsiderecl ifi the U.A cr p*rf*rmance ccrnpli*nce peth ift RE$check. fiach Et*b-on-#rade assembiy in the specified c{imat* aone milst meet th* mininnum energy code insulaticn R-value and depth requir*m*nls. Envelope Assemblies a\l $ $ Ceiling: Raised or Energy Truss Wall north: Wood Frame, i.6" o.c. Door: Glass Door (over 50% glazing) Window: Vinyl Frame Wall south: Wood Frame, L6" o.c. Door 1: Solid Door (under 50% glazing) Window 1.:Vinyl Frame Wall east: Wood Frame, 16" o.c. Window 2: Vinyl Frame Wall west: Wood Frame, 1.6" o.c. r,952 536 4L 53 485 101 44 420 10 62r 0.020 0.060 0.270 0.270 0.060 0.270 0.270 0,060 0.270 0.060 0.026 0,060 0,300 0.300 0.060 0.300 0.300 0,060 0.300 0.060 39 27 11 L4 20 27 t2 25 3 32 5L 27 !2 16 20 30 13 25 3 32 49,0 19.0 19.0 19.0 0.0 0,0 0.0 0,0 0.0 Co,m,plia'nce: Fasses using IJA trade-cff Gross Area (}r Perimeter Cont. Prap. Req, R-Value U-Factor U-FactorAssemblyR-Value Cavity UA UA Prop. Req, r.9.0 Project Title: MONICO Data filename: Report date: 04116124 Page 1 of 2 CavitYt R-Value Cont. Prop, Req. R-Value U-Factor U-Factor Prop, UA Gross Area Perimeter Reg.orAssembly UA Door 2: Solid Door (under 50% glazing) Window 3: Vinyl Frame Wall lower east: Wood Frame, 16" o.c. Floor: Slab-On-Grade (Unheated) lnsulation depth: 3.0' lnsulation position: Fully lnsulated (uniform R-value across perimeter and under slab) Basement Wall: Solid Concrete or Masonry Wall height: 10.0' Depth betow grade: 8.0' lnsulation depth: 10.0' Basement Wall L west: Solid Concrete or Masonry Wall height: 3.5' Depth below grade: 3.0' lnsulation depth: 3.5' 28 64 93 138 969 105 8 L7 6 I 19 619.0 0,0 72.O 12.0 0.274 0.270 0.060 0,300 0,300 0.060 L2.0 0.336 0.360 0 0 0.0 0.062 0.050 60 48 50.0 0.073 0.050 8 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications,.and other calculations submitted with the permit application. The proposed building has been designed to meet the 2018 IECC requirements in REscheckVersion : REScheck-Web and to comply with the mandatory requirements listed in the REScheck lnspection Checklist. Name - Title Dates Project Title: MONICO Data filename: Report date: 04116124 Page? of 2 2018 IECC Energy Effi ciency Ce rtificate Above-Grade Wall Below-Grade Wall Floor Ceiling / Roof Ductwork (unconditioned spaces): Window Door Heating Syste Cooling Syste Water Heaterr_ Name: Comments 19.OO 12.OO 12.0O 49.00 o.27 o.27 Date: l,nsul*tion Ra ing R-Val,ue Glnss & Deor Rating U-Facter sl{GC Heating & Cooling Eq,uiprne*t Efficie.ncy