HomeMy WebLinkAboutAmended Conditions of Permit 06.03.24AMENpEp (06/03/2024) CONDIflONS OF PERMIT
BLRE-02 -24-8509
ROGER WALTERS
New Sing le-family dwelling including basement
with attached garage and covered porches
461 Meadow Creek Dr., Parachute
Battlement Creek Vlg, Sec 2, Blk 5, Lot 06
1) ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE (I.R.C.)AND 201B
INTERNATIONAL ENERGY CONSERVATION CODE (I.E.C.C.)
2) PROPOSED TMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE |TEMS CONTAINED lN THE ATTACHED "GARFIELD
COUNTY BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON
THIS LIST.
3) ELECTRTCAL PERMITT|NG AND TNSPECTTONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL ROUGH-lN
APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL
INSPECTION & CERTIFICATE OF OCCUPANCY.
4\ WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLY WITH WILDFIRE MITIGATION AND DEFENSIBLE
SPACE RECOMMENDATIONS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE DISTRICT. PLEASE REFER
TO THE GARFIELD COUNTY COMMUNITY DEVELOPMENT WEBSITE FOR ADDITIONAL INFORMATION.
5) NOTE TO PROPERry OWNER: FLOOR PLAN (A1) DEPICTS A 35 FT BY 17 FT COVERED PORCH OFF THE MASTER
BEDROOM SUITE, GREAT ROOM, AND ATTACHED GARAGE. /FTHIS COVERED PATIO SPACE IS ENCLOSED /
CONVERTED IN FUTURE TO BECOME HEATED, CONDITIONED HABITABLE LIVING SPACE .. BE ADVISED A
SEPARATE BUILDING APPLICATION SUBMITTAL BY THE OWNER TO GARFIIELD COUNTY COMMUNITY
DEVELOPMENT DEPARTMENT TO VERIFY BULDING LIFE SAFEry AND LAND USE COMPLAINCE WILL PERTAIN.
(REFERENCE tRC SECTTONS R302 AND R310) -- BEDROOMS MUST NOr HAVE WINDOW / DOOR OPENINGS
DI RECTLY I NTO GARAGES).
6) OpEN HOLE SOTLS REPORT, TNCLUDING COMPACTION REPORT FOR STRUCTURAL FILL, lS REOUIRED AT FOOTING
INSPECTION AND PRIOR TO ANY CONCRETE POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO
THE BUILDING INSPECTOR. 1,000 PSF soil bearing.
7\ FIELD VERIFY ANY PRE-ENGINEERED ROOF TRUSSES AS MAY PERTAIN. HAVE ENGINEERING FOR BUILDING
INSPECTOR AT TIME OF FRAME INSPECTION.
8) BLOWER DOOR TEST tS REOUTRED. MUST SUBMTT BLOWER DOOR TEST REPORT TO GARFIELD COUNIY
COMMUNITY DEVELOPMENT DEPT. OFFICE PRIOR TO SCHEDULING FINAL BUILDING INSPECTION / C.O. FINAL.
9) A LOT TMPROVEMENT CERT|FtCATE, SEALED BY A COLORADO LICENSED SURVEYOR, IS REOUIRED AT
FOUNDATION INSPECTION TO VERIFY STRUCTURE IS IN COMPLIANCE WITH SUBDIVISION SETBACKS AND/OR
PLATTED BUILDING ENVELOPE.
10) pRESCRtpTtVE PATHAMENDEDUSTNG RESCHECKSOFTWARE FOR ENERGY COMPLIANCE OFTHIS HOME
DESIGN. REVISEDMAN'JALJREPORTSHOWSHEATEDCONDITIONEDBASEMENT,OWNERISENCOURAGED
TO COLLABORATE WITH THE MECHANICAL SUPPLIER TO PREPARE AN UPDATED NEW MANUAL J REPORT
SHOWING CORRECTED WINTER DESIGN TEMPERATURE OF MINUS 2 DEGREES FOR LOCATION LESS THAN 7,OOO
FT ELEVATION. ALL NEW HOMES TO HAVE WHOLE.HOUSE MECHANICAL VENTILATION SYSTEM INSTALLED
(2015 IRC TABLE m1507.3.3(1)AND (2) SHOWN ON COVER SHEET.
1 1) 06/03/2024 REV'SED ARCHTTECTURAL SHEETS SHOW DELETTON OF 2,095 SA FT CRAWL SPACE AND
INTRODUCNON OF 2,095 SA FT FULL HEIGHT BASEMENT. A2.O BASEMENT LEVEL FLOOR PIAN LAYOUT
DEPICTS ENCLOSED FURNACE ROOM, HALF BATH, OPEN STORAGE SOUTH AND OPEN STORAGE NORTH W'TH
SINGLE BASEMEA'I EGRESS WINDOW AND DOUBLE DOOR EXITING TO BACI<YARD PATIO. A2.1 LOWER LEVEL
THERMAL ENVELOPE AND REVISED MANUAL J REPORT DEPICI COND'TIONED BASEMENT WITHIN THE
THERMAL ENVELOPE. SHOULD OWNER WISH TO CONVERT HEATED CONDITIONED REs'DENT'AL STOFjGE
TO OTHER FUTURE ROOM USES, IT IS RECOMMENDED OWNER PROACIIVELY SUPPLY L'GHT AND
VENTII.ATION PURSUANT TO 201 5 IRC R303.4 (DUR'NG THE ORIGINAL BUILD). FIELD VERIFY AS-BUILT
NATURALORMECHAN'CALVENTIATION AT ROUGH.IN / FRAMING INSPECNONS. ATTHETIMEOF PLAN
CHECK/,NG REVTSEDARCHTTECrURALSHEETS(DATED 05/29/2024) - P|4.NS EXAMINER CONFIRMS
ADDITIONAL BASEMENT SAUARE FOOTAGE AND REVISED HOME LOCATION ON LOT 6 APPilRTO COMPLY
WITH THE BATTLEMENT MESA PUD GUIDE AND ZON'NG REGULATIONS.