HomeMy WebLinkAboutOWTS Spec SheetItem #
lilt {o60-2GP
{060 Gallon Tiro Gompartment
lnfiltratot@ Poly Tank
lT'Top
Mew
TANKTOP
HALF
CONTINUOUS
GASKET
&u[TANK
INTERIOR SEAM CLIP
(s)
ALIGNMENT
DOWEL (34)TANK BOTTOM
HALF
Mid-Height Seam
Section
24'A@ESSOPEN|I{G\Section
Mew
Tank lndude llds
51,7'.
I
17',A',OUTLET
7T'
il.7
EXTERIOR
HEIGHTr Compliont with CSA ond IAPMO Stondordso PVC risers ovoilobleo Secondory sofety screen ovoiloble with PVC riserr Moximum buriol depth is 48"
o Minumum buriol depth is 6"o Tonk is not roted for vehiculor troffic loodingr Exterior of monhole cover includes the following
worning: "DANGER DO NOT ENTER: POISON
GASES''
SEAM CLIP
(rYPrcAL)
LIFTING STRAP
(rYPrcAL)
End
View
lnvert r Dimensions
I"'
dei lnlet Outlet Length Width Height
r 47" 44" , 1l7" t62.2" t 54.7"
Digging Specs Net
Copocity
1094 gol
Weight
ffir,nSilsn'
I;IIATCIYTA'}G.
12' Long x 7' Wi
320 lbs
aE
(J \
o \o\o
<-o
o\
E g
l"
Bulkhead
Wator &
Warilewater
r Systems
r Prcdude
Frolssrs6z6f ffigtrr
Fu: filo) 3S€727 BHE\ftb' @81211
Webclb: wrrrv.wllenmtom
Emll : frottUck@tdleWtmtomPRtCASflIne. rsemce
Residential Biotube' Effluent Filters
Applications
Our patente d* 4-in. (100-mm) Biotube Effluent Filters, Biotube Jr., Biotube
Insert Filters, and Biotube Base Inlet Filters are ideal for residentid septic
tanks and have a lifetirne wafranty. They prevent large solids from leaving
the tank, dramatically improving wastewater qualiry and extending the life
of residential drainfields.
4-in. (100-mm) Bioutbe Effluent Fiher
I
4-in. (1 00-tnm) Biotube Jr.
(4-in. Biotube carnidge auail-
able separatefi as Insert Fiber)
8-in. (200-mn)
Base Inlet Filter
4-in. (100-mn)
Insert I'iber
I
at
l
:
i
'
1
I
t
:.'.,
I
i
Orenco's superior efflaent fhers resist clogging better than all other brands. Our stan-
dard, full-sized 4-in. (100-mm) Biotube Effluent Fiber prouidcs rtaximtr.m long-term
protection in a contplete pachage, with housing. Our 4'in. (100-mm) Biontbe Jr', at
balf the size of our standard model, has more f.hering capacity tban the full-sized fhers
sold b1t otber manufacturerc. For tanhs witlt existing outlet tees, the Biotube Insert Fiber
is ideal. Andfor low-profle tanhs, there:s the Base Inlet Fiber'
'Covered ty prrenr numbers 5,492'635 and4,439,323
To 0rder
Call your nearest Orenco Systems@, Inc. distributor. For nearest distribu-
tor, call Orenco at 800-348-9843 or go to www.orenco.com and click on
"Distributor Locator."
APS.FI-1
Rev.3.4 @ 11/10
0ronco Systomso, lnc.
Standard Features & Benefits
. Has 5-10 times
more flow area
than other brands,
so lasts many
times longer
between clean-
ings, increasing
homeowner
satisfaction
. lnstalls in min-
utes inside new
or existing tanks;
eKendible tee
handle for easy
removal
0ptional
Features &
Benefits
. Alarm available, to
signal the need for
cleaning
. Flow modulating
discharge orifices
available to limit
flow rate leaving
tank, mitigat-
ing surges and
increasing
retention time
. Custom and
commercial sizes
available
. Easyto clean by
simply hosing off
whenever the tank
needs pumping
. Removes about
two-thirds of sus-
pended solids, on
average, extending
drainfield life
. Corrosion-proof
construction, to
ensure long life
. Lifetime warranty
Biotube
Filteting
Process
Effluent from the
relatively clear zone
ofthe septic tank,
befirueen the scum
and sludge layers,
horizontally enters
the Biotube Effluent
Filter. Effluent then
enters the annular
space between the
housing and the
Biotubes, utilizing
the Biotubes'entire
surface for filtering.
Par-ticles larger than
the Biotube's mesh
are prevented from
leaving the tank.
OrencoSystems''
lncorporated
Changing tfu \Ya1 the
W'o rld Do et Wns te ua te rs
www.oienco.com
*.-',f,*r
€
Nomenclatures
4-in. Biotube Fiher (standard)
FT Mn!
Housing height:36" and 44" are standard
Filter diameter (inches)
W =fitsS = fits
n/pe 3034 outlet pipe
Schedule 40 outlet pipe
/8" liltration
il6" filtration
Biotube effluent lilter series
f-in. Biotube Filter (base inlet model)
FT 08 22- 14 B
Blank
P
--T--
I 0ptions:
Blank = no optionsM = flow modulation plate installedA = float bracket attached
Cartridge height: 2B" and 36" are standard
0plions:A = float bracket
FS = 2" outlet orifice
FSO = 2" outlet orifice and overflow platet
= Ilow modulation plate installed
= float bracket attached
Cartridge height (inch€s)
Filter diameter (inches)
Base inlet model
Cartridge heioht: 14" standard
Housing height: 22" standard
Filter diameter (inches)
08=8"
Blank = 1/S" filtrationP = 1/16" filtration
Biotube effluent tilter selies
- Also available with coupling and sleeve as a "kit": Ft-OVERFLOWKIT
4-in. Biotube Jf. (inctudes carlridse and housing)
FTJ 04 18
no options
-Tiloon.'
Blank =
IV
A
lits
tits
= 1/S" tiltration
= 1/l6" filtration
Type 3034 outlet tee
Schedule 40 outlet tee
Blank
P
Junior series
Biotube effluent {ilter series
4-in. Biotube Filter lnsert (cartridse onM
FTi 041B-
For customized options (e.9,, NC
indicates North Carolina reglons)
fits Type 3034 outlet tee
lits Schedule 40 outlet tee
Blank
D
Cartridge height (inches)
Filter diameter (inches)
= 1/S" filtration
= 1/16" {iltration
lnsert
Biotube effluent filter series
Distributed By:
&in. Biotube
Effluent Fiher
Extendible PVC handle
Stainless steel set screws
Top seal plate
Air
Biotube@ filter cartridge
Solid base
Filter housing
4-in. Biotube Jr
Tank wall
Riser
wall
V
Double Walled PVC Riser & Lid Options
Poly Lid
(Static load tested to 50m bs). Skid resistance surfiace. Available in green. Highest level of UV Probction includedo lncludes a bam gasket br airtight and
watertight appl ications. lncludes squars drive scr€urs b disoounage
unauthorized enfry. lnsulation panels achieve R-10 insulation rating
2'of lnsulation
Standard
Orenco @ DuraFiber* Access Lids (FLD)
Not recommended br vehicularhaffic
24'and 30' Diameibns. Solid, resin-infused fiberglass consfrustion. 20,000-lb breaking sfiengfrt. Standard gr€en or brctrn colors. Available with orwithout ureiltane lid gasket
o Available with carbon filhation. 4 stainless steel flathead socket cap scr€tils & hex
key wrench. lnsulated lids available - 2'or4'
Double Walled PVC Riser
. Available in 24' and 30" Diamebr. Gut to lengffrr. Sold in +l-2'increments
. Must be cut between ribs
tr PRECAS|f'rnc. oserule
(t{o) to56z6{ moom'fl7
P.O.Bo(ms
Fu: fllg) 3g5€T27 H'sE\nsa' @|,/'n1
Webclb: wttw.valleypreef om
Erml[ fronUek@valleyptmstom
Water &
Warilewalor
r Syeteme
r Prcducb
POTYLOK DISTRIBUTION BOX,
RISERS, AND LID
UD.BOX 0 uD€ox 8
D.BOX SEAL
(E\,ERYDs(o*3ffilH
4tEAll}
16'SIDE CUT OUT
TOACCEPT
POLYLOK SEAL
NO.300'l TEAR OUT FOR
4',SDR-35 0R
scHD40
NOTTOSCAIE
UD.BOX O'RISER
ROTO.FLOW 4'
+
6"
i
uD-BOX 12'RISER NOTTO SCATE
POLYLOCK
'v-NorcH'wE[R
1
g{ PEl8
8EFt6/E-lt{O
RIBS PR('IIIDE FRISIION
FITFORAI f PIPEID
#t l
,mTEETtl
20'GOVER FOR RISER &DAOX iroTTtrsAr.E
GASKETED SEAL ON
LID & RISER
VALLTY
Wetcr &
Warilcwftr
r Systems
r Ppduds
(?{9t3e5S7E{ am&'ru'3{7
P.O.Bo(95
Fu: O1g) ag$*?Tz| H'mVlsh' cofial
Webrlb: nrnv.vallqprccastmrn
Emll : fondsk@Mallqpr€rut@mPRTCASI1InG. rserulce
Ouick4 Plus
All-in-One Periscope
Ouick4 Plus Standard Chamber Ouick4 Plus
All-in-One 12 Endcap
Center Structural Columns
The Ouick4 Plus Standard Chamber offers maximum strength through its two center structural columns, This
chamber can be installed in a 36-inch-wide trench. Like the original line of Ouick4 chambers, it offers advanced
contouring capability with its Contour Swivel ConnectionrM which permits 1O-degree turns, right and left. lt is also
available in four-foot lengths to provide optimal installation flexibility, The Ouick4 Plus All-in-One 12 Endcap, and
the Ouick4 Periscope are available with this chamber, providing increased flexibility in system configurations.
Quick4 Plus Standard Chamber
. Two center structural columns offer increased stability and
superior strength
. Advanced contouring connections
. Latching mechanism allows for quick installation
. Four-foot chamber lengths are easy to handle and install
. Supports wheel loads of '16,000 lbs/axle with 12" of cover
Ouick4 Plus All-in-One 12 Endcap
. May be used at the end of chamber row for an inlet/
outlet or can be installed mid-trench
. Mid-trench connection feature allows construction of
chamber rows with center feed, as an alternative to
inletting at the ends of chamber rows
r Center-feed connection allows for easy installation of
serial distribution systems
. Pipe connection options include sides, ends or top
Quick4 Plus All-in-One Periscope
. Allows for raised invert installations
. 1B0o directional inletting
. Twelve inch raised invert great for serial applications
-nuick4 PLUS
;
THE QUICK4@ PLUS STANDARD CHAMBER
Ouick4 Plus Standard Chamber Side and End Views
(EFFECTIVE LENGTH)
u"
Ouick4 Plus All-in-One 12 Encap Front, Side and End Views
11.z',
13'
B'l B"5.3" INVERT
33"
Ouick4 Plus All-in-One Periscope
OUlCK,l PLUS
ALL.IN4NE
(360" SWTVEL )
o
12.7'INVERT OUICK4 PLUS
ALL.IN.ONE 12
ENOCAP
5"9"
INFILTRATOR SYSTEMS, INC. STANDARD LIMITED WARRANTY
(a) The slructural integrity o{ each chamber, end plate, wedge and other accessory manufactured by lnfiltrator ( "Units"), when installed and
oferated in a leachfiel-d oJ an onsite septic system in accordance with lntillrator's inshuctions, is warranted to the original purchaser ("Holdea')
against defective materials and workmanship for one year trom the date that the septic permit is issued for the septic system containing the Units;
piovided, however, that il a septic permit is not required by applicable law, the lvarranty period will begin upon lhe date that installation of the
septic system commences. To exercise its waruanty rights, Holder must notity lnfiltrator in writing at its Corporate Headquarters in Old Saybrook,
Conneciicut withjn fifteen (15) days of the alleged defect. lnfiltrator will supply replacement Units for Units determined by lnfiltrator to be covered
by this Limited Warranty. lnfiltratofs liability specifically excludes the cost of removal and/or installation of the Units.
(b)THE LIMIIED WAHRANTY AND HEMEDIES IN SUBPARAGRAPH ( ) ARE EXCLUSIVE, THERE ARE NO OTHER WARBANTIES WITH RESPECT
io ftir uutrs, tNcLUDtNc No tMpLtED WARRANTTES oF MERcHANTABIL|TY oR F|TNESS FoF A PARTIcULAR PUFPoSE
(c) This Limited Warranty shall be void if any part of the chamber system is manufactuled by anyone other than lnfiltrator. The Limited Watranty
does not extend to incidental, consequential, special or indirect damages. lnfiltrator shall not be liable for penalties or liquidated damages,
including loss of production and profits, labor and materials, ovelhead costs, or other losses or expenses incurred by the Holder or any third party
Specific;lly excluded from Limited Waffanty coverage are damage to the Units due io ordinary wear and tear, alteration, accident, misuse, abuse
oi negtect bf the Units; the Units being subjected to vehicle traffic or other conditions which are not permitted by the installation instructionsl failule
to ma]ntain the minimum ground covirs set torth in the installation instruclions: the placement of improper malerials into the system containing
the Units; failure of the Units or the septic system due to improper siting or improper sizing, excessive water usage, improper grease disposal,
or improper operation; or any other event not caused by lnfiltrator. This Limited Warranty shall be void if the Holder lails to comply with all of the
terms set forth in this Limited Warranty. Further, in no event shall lnfiltrator be responsible for any loss or damage to the Holder, the Units, or any
third pany resultjng from installation or shipment, or from any product liability claims of Holder or any third party. For this Limited Warranty to
apply, tire Units must be installed in accordance with all site conditions required by state and local codes; all other applicable laws; and lnfiltratoas
installation instruclions.
(d) No representalive of lnfiltrator has the authority to change or extend this Limited Warranty. No u/arranty applies to any party other than the
original Holder.
The above represents the Standard Limited Watranty offered by lnfiltrator. A limiied number of states and counties have different warranty
requiremenls. Any purchaser of Units should contact lnfiltrator's Corporate Headquarters in Old Saybrook, Connecticut, prior to such purchase,
to obtain a copy o1 the applicable warranty, and should carefully read that warranty prior to the purchase of units.
s?>-$tr
IN FILTRATOR'
systems inc.
6 Business Park Road . P.O, Box 768
Old Saybrook, CT 06475
860.577.7000 . FAX 860.577.7001
soo.22'a.4436
www. inf iltratorsystems. com
Quick4 Plus Standard Chamber Specifications
Size(Wx Lx H) 34"x53" x 12" (86 cm x 135 cm x31 cm)lnvert Height 0.6n, 5,3',, LO" 12.7'
(1 .5 cm, 8.4 cm, 18.5 cm, 22.6 cm)Effective Length .,48" (122 cm)
THE OUICK4@ PLUS STANDARD CHAMBER
For technical assistance, installation instructions or customer service, call lnfiltrator Systems at 800'221 .4436
U.S. Patents: 4,759,661 ; 5,01 7,041; 5,1 56,488; 5,336,01 7; 5,401,1 '1 6i 5,401,459; 5,51 1,903; 5,71 6,1 63; 5'5BB'778; 5'839'844
Canadian Patents: 1,329,959i 2,004,564 Other patents pending.
is a registered trademark in Mexico. Contour Swivel Connection is a trademark of lnfiltrator Systems lnc. @ 2009 lnfiltrator Systems lnc. Printed in U S.A PLUSos 1010lSl-2