HomeMy WebLinkAboutOWTS Engineers Revision 06.04.24V$�yS V4�K /ELL 200' MI 1000 OD{�GONCRETE SFP fiIC TANK C O 23 aw (3) R��11NS OF (12) 6 TOTAL STp CHAMBERS ON ANDY LOAM I 1 I Xlw r 81.3 Y�i�XYu q� I I E �N _4 4 � I 4d .k Ti M M c � � p,a xew m nnm 1- % SLOPE �� n - 2'X2' RI ID IN ULATION� / jJ J 10.0' MIN SEPTIC SITE PLAN APPROX 1'=40' I�^ I'�-1 LL t o /}I RES RV� STA� r. ARE` p I U 13\ 5 ISPECTI❑f� PORTS -TYP \) TOTAL \ \ I p. w.n n+Xd Yt FowX � Mn . 0 L1C e 7 aa0 XUU mUj IoU1 0 m SHEET SS1 BROCK CIVIL, LLC Professional Services P.O. BOX 23 Eagle, CO 81631 Cell 970-471-2121 May 21, 2024 Borah Barn/ADU 3207 CR #342 Silt, CO Garfield County, CO PN 245502200038 DESIGN CALCULATIONS FOR SEPTIC SYSTEM REFERENCES Garfield County Public Health Agency On -Site Wastewater Treatment System Regulations adopted March 6, 2023 ("Regulations"). Colo. Dept. of Public Health and Environment Regulation #43 5 CCR 1002-43. DESIGN FLOWS Number of bedrooms = 2 Number of persons per bedroom = 2 (design flow) Single Family Residential Design Flows = 75 gallons/day/person Q design = 2 bdrms x 2 persons/bdrm x 75 gallons/person/day = 300 gpd SOILS PROFILE (Visual and tactile investigation): Soil type 2A (SEE USDA) CHAMBER TRENCH CONSTRUCTION: Install chambers onto each undisturbed trench (approx) 3 ft X 48 ft bed level. in (3) run of (12) chambers. Backfill the chambers and all voids between with native Sandy Loam (no cobbles) to top of chambers. TOP SOIL CONSTRUCTION: Back fill over chambers with 12 inches of high organic top soil and reseed to native vegetation. D not compact top soil! SEPTIC TANK & PIPE CONSTRUCTION: Install septic tank level with 6" sand gravel bedding. Install the delivery pipe from the residence to the septic tank 2% slope, Schedule 40 PVC (ASTM D 2665) or SDR 35. Insulate under driveway or any parking area with 2" rigid insulation. Septic tank to have risers brought to or above final grade and shall have a secure locking mechanism. ALARM: A visual and audible alarm shall be incorporated into the controls and electrical connections. Alarm to be in an open area or area easily visible. NOTES: 1. The building sewer line from the barn to the septic tank shall have a slope of inch per foot (2%). Bends in the building sewer shall be limited to 45 degrees. 2. Use topsoil for vegetative cover. 3. Assemble and install the Infiltrator Chambers in the trenches according to the manufacturer's recommendations. 4. Avoid vehicle traffic, animal concentrated loads and irrigation over the system. Fencing advised. 5. The Septic System Installation shall be inspected by the Design Engineer prior to backfill. (Pictures not sufficient) 6. All installations shall meet the rules and regulations of the Eagle County Environmental Health Department. 7. Electrical requirements of alarm to be determined by Electrical Contractor prior to construction. In general, all electrical to be 18" below grade. 8. The Bio effluent screen shall be installed at outlet tee and maintained annually or as needed. 9. Pump septic tank every 2-3 years minimum to prevent deterioration of concrete. 10. Installer must be licensed installer in eagle county; see permit. MINIMUM DIMENSIONS TO FACILITIES ACTUAL (MIN. REQ'D) Profile Holes (2) Textural Classification (New Location) 0.0 to 2.0 ft Topsoil with organics SEPTIC TANK TO BUILDING 20 FT (5 FT) 2.0 to 8.0 ft Tan, Sandy Loam SEPTIC TANK TO WATER LINE 30 FT (10 FT) No groundwater. SEPTIC TANK TO ABSORPTION BED 81 FT (10 FT) ABSORPTION BED TO WELL SPRING (100 PERCOLATION TESTS: Visual and tactile evaluation of the treatment soil indicates Sandy, Silty Loam to Loam with a ABSORPTION BED TO BUILDING 80 F0 FT ( T) percolation rate 30 Minutes/inch. ABSORPTION BED TO WATER LINE 140 FT (2 F (25 FT) ABSORPTION BED TO IRRIGATION N/A (50 FT) INFILTRATOR CHAMBER SYSTEM IN SERIAL TRENCH DISTRIBUTION ABSORPTION BED TO PROPERTY LINE 0 (10 FT) Given this information, the new barn would be best served by a chamber system in serial trench distribution. BUILDING SEWER TO WATER LINE 3F 30 FT (]0 FT) Treatment Level 1 Effluent: Per Table 6-3: 10-1 Surface of Soil Treatment Area (STA) shall be based on LTAR of secondary sand and not the percolation rate. Soil Treatment Area = Design Flow (gals/day)/LTAR gal/day/SF. Long Term Acceptance Rate (LTAR) is calculated as follows: • According to Table 10-1, the LTAR is estimated to be 0.5 Gal/day/SF. • Design Flow = 300 GPD/ 0.5 G/day/sf x (0.7) (Table 10-3) = 420 SF. • Using Standard Quick 4 Infiltrators; 420 SF/12 sf per Infiltrator = 35 Infiltrators. • Trench shall be (3) runs of (12) Infiltrators, TOTAL (36). • Valley Precast 1,000 gallon tank with over flow audible and visual alarm. • Chamber Product to be Infiltrator Systems, Inc. "Quick 4" Standard Chambers. SEPTIC TANK: Table 9-1, for a 2 bedroom residential structure, Minimum Tank Capacity is 1,000 gallons in the first 2 chambers, and meets a minimum 48 hours of retention. Owner decision to install 1,250 tank. Proposed Valley Precast Tank: Inlet side 843 gallons, Outlet 416 gallons. Water tightness per Section 9, ASTM C 1227-12. INSTALLATION Install all components to the required setbacks required by regulations. No over excavation allowed for septic tank or trenches. See 43.7, Table 7-1 for further information and requirements if changes are made to assure proper clearances. SANDY LOAM 55% SAND 30% SILT 15% CLAY (N J Jno o NOr-' J Q�S 0 UGO^ mJOp oa0v� R W J> m W QU W to Z O N Q J D U J Q U U F W W 0) D ON Q4 Zzk0 U CY < ff l_ mUJ = r V) 40 ll�N 0� M SHEET SS2.1 DESIGN NOTES • Design per performance test per ASTM C1227 • Top surface area 56.25 ft' • f'c ® 28 days; concrete = 6.000 PSI Min. Installation, • Tank to be set on 5" min. sand bed or pea gravel • Tank to be backfilled uniformly on all sides in lifts less than 24' and mechanically compacted • Excavated material may be used for backfill, provided large stones are removed • Excavation should be dewatered and tank filled with water prior to being put in service for installation with water table less than 2' below grade • Meets C1644-06 for resilient connectors • Inlet and Outlet identified above pipe • Delivered complete with internal piping • PVC or concrete risers available • Secondary safety screen available with PVC riser • Option of pump or siphon installed ALLOWABLE BURY (Based on Water Table) WATER TABLE ALLOWABLE EARTH FILL 0'-0" 2'-0" 1' — 0" 3' — 0" 2'-0" 3'-0" 3'-0' 4'-0" DRY 4' — 0" 20" Clear Access • TANK ID 1,250 Gallon Tank Top View Section View Digging Specs Invert Dimensions Net Capacity Net Weight 13' Long x 7' Wide Inlet Outlet Length Width I Height Inlet Side Outlet I Total Lid I Tank I Total 56" below inlet 56"' 53" 135" 60" 68" 843 gal 416 gal 1259 gal 3120 Ibs 10880 Ibs 14000 be BIO FILTER OUTLET (CLEAN ANNUALLY -MIN) wabr 3 (719) 395.67" 28006006 Rd. 317 wastw*llt r P.O. B=925 o VALLEY `�"'8 Fmc (719)39"M BuemVWACO81211 . Products Wobeft www.veleyprec ast.00m PRECAST, Inc. • servioe Pam(: frorrtdosk@valleyprecast oom i e M �N J �N2 JMO I u J Q�S 0 500,u mJO0 oa�vz of 4j J> In 0 W QU W W J Q H W 0 0 F a W 1n =r V) QO afN 014) M SHEET SS2.2 INFILTRATOR SYSTEMS INC. DUICKO STANDARD CXrU18ER QUICK4 CHAMBER INSPECTION PORT TYPICAL INSTALLATION DETAIL OpBan A'. CHAMBER RISER TO GRADE Option B. INSTALLATION WITH VALVE BOX ax..m r) M<uw..uexw. ,.ne.m....s.«.BOrha ��-`JI IEnc�mv OUICX4 STANDARD MULTIPORT END CAP a/.NA,tlt MRl6. MC ..,RATP PS1D6 FC e lAm Pan wV INFILTRATOR SY31FY5 WG a Sale iN� WFILIRANR SYSRLS INC EtXM3 WK%15rANDARD 2 6n-Mfi .wasAM 1M1w6mOcm W9PECMM PORT DETN 1I mNFAI.n III -Ayes n !P 6T-]NI CULNA STANDARD PIAYBER RETAIL Sctls NOT TO SCALE CM1ackeE IiGP Scale NOT 10 SCALE (TatluE BCP De<= cAD Newa� DBL< asroTECX DrP.n B . rcrs SNeeL t i DFB.n B . HIS sneer 1 1 INFILTRATOR SYSTEMSINC, OUICK<CX6MfiER SAME END 6ERIAL OISTRIfiU11IXJ TRENCH DETAIL INFILTRATOR SYSTEMS INC. (PLAN VIEwI OUICKd CHAMBER NOTTO SCALE SLOPED SERIAL DISTRIBUTION DETAIL CROSS SECTION S�PE as sraxaRocwMaEx NOT TO SCALE I ORIGIrvAL GMOE DIFFERENT ELEVATION OVERFLOW 9fPllc T'UR ESTABLIBX VEGETATVE COIER 12 NIN., M10 LO40ARFA5 C! 8'MIN., NONTRAFFIC IlREA3 ,x.,.w��re����, a,rw 6601 `"`"" 6600' � iVP. xµTxPTExxW CiNTEWTOLENTER SYACINO PER LODE 6659' 10' (IF CHOSEN) PLEASE NOTE'. ALL INFILTRATOR CHAMBERS MAY BE USED IN THIS A PPLICPiION ... pM�igp WFILTXATCF SYSTFl15 6 M i eNx�RPV RBILTUTpi Sr81EY5 P en me IHG DNLK1 CNAMfi£RS m Y9XpIL cl mam SAYE END SEPoAL P.P BY ru mMY�� L' wi Wc. DWdN LXIJIBFA PUAaEmr[siLlrFltRwratcwfBiRs msveE3EUSEGbT'ENMrER � ��� gSTERUl10N ADFED YMAL qST. TRFNW uTUL �� oKl DETAIL cRoss sscTlaN seas NOT ro scALE grxEetl 6cP xae NOT ro seAu .uw BCP Deco asua_D+o Seek, aasERIAL Y qwn BR KJB SNeel t 1 DIORn B . KGB Awl 1 1 n� IN J 00Ni Jno � JN0 _j (ME W Scale) INFILTRATOR SYSTEMS, INC: > x w Y PLACEMENT OF FILL MATERIAL WITHIN ZONE OF DISPOSAL U 0 0 / O m J 0 rc v0�rn� a '� a— aP,Rx...Er.,,VEw,Fa m J J 40 W SPLASH PLATE 777, �N Reaccam N TIVE $' J Q al�� 0 A\\/ W N/yU H. / 0 mU J =nW O N �N TRENCH DETAIL NON -CONFINING OM 21 m Inflbalor BYSkms, Inc. S+Y Eqi to3cu[ c4 Pace HGSG Be BY, xP HIGH HIL �PpO LIC S Im CPc i � � C O� 1 305 .S�NA� .. m M � aW,W SHEET SS2.3