Loading...
HomeMy WebLinkAboutObservation of Pit Excavations 02.09.2024rcn $,'iffi'1ffi,#rn"'n3;'**' An Employcc Orncd Compony 5020 County Road 154 Glenwood Springs, CO 81601 phone: (970) 945-7988 fax: (970) 945-8454 email : kaglenwood@kumarusa.com www.kumarusa.com Ofiice Locations: Denver (HQ), Parker, Colorado Springs, Fort Collins, Glenwood Springs, and Summit County, Colorado February 9,2024 Shane Wiescamp 1977 Covnty Road 210 Rifle, Colorado 81650 wiescamps@msn'com project No.24-7-r4r Subject Observation of Pit Excavations, Proposed Shop Building,1977 County Road 210, East of Rifle, Colorado Dear Shane: As requested, a representative of Kumar & Associates observed the pit excavations at the subject site on February 2,2024 to evaluate the soils exposed for foundation support. The findings of our observations and recommendations for the foundation support are presented in this report. The services were performed in accordance with our agreement for professional engineering services to you dated February 2,2024. The proposed shop will be a tall one-story steel frame strucflre with a slab-on-grade floor. At the time of our visit to the site, two pits were excavated in the proposed building area. The soils exposed in the pit excavations consisted of about 6 inches of road base over natural, sandy silty olay down to the bottom of fhe pits at 3Yzto 4 feet. Results of swell-consolidation testing performed on samples taken from the site, shown on Figures I and 2,indicate the soils are moderately compressible under conditions of loading and wetting. The results of a percent finer than sand size gradation analysis and Atterberg Limits testing performed on a sample obtained from Pit 2 are shown on Table I and indicate the soils are sandy silty clay. No free water was encountered in the pit excavations and the soils were moist. Considering the conditions exposed in the excavation and the natwe of the proposed construction, spread footings placed on the undisturbed natural soil designed for an allowable soil bearing pressure of 1,500 psf should be adequate for support of the proposed shop. The exposed soils tend to compress when wetted and there could be some post-construction settlement of the foundation if the bearing soils become wet. Footings should be a minimum width of l8 inches for continuous walls and2 feet for columns. Loose and disturbed soils and existing fill in footing areas should be removed and the bearing level extended down to the undisturbed natural soils. The bearing soils should be protected against frost and concrete should not be placed on frozen soils. Exterior footings should be provided with adequate soil cover above their bearing elevations for frost protection. Continuous foundation walls should be reinforced top and bottom to span local anomalies such as by assuming an unsupported length of at least 12 feet. Foundation walls acting as retaining structures (if any) should also be designed Shane Wiescamp February 9,2024 Page2 to resist a lateral earth pressure based on an equivalent fluid unit weight of at least 55 pcf for on- site soil as backfill. A perimeter foundation drain should not be needed for the proposed slab'on- grade floor level. Structural fill placed within floor slab areas can consist of a suitable imported sandy gravel soil such as %-inch road base compacted to at least 95% of standard Proctor density at a moisture content near optimum. Backfill placed around the structure should be compacted and the surface graded to prevent ponding within at least 5 feet of the building. The recommendations submitted in this letter are based on our observation of the soils exposed within the two pit excavations. This study is based on the assumption that soils beneath the footings have equal or better support than those exposed. The risk of foundation movement may be greater than indicated in this report because of possible variations in the subsurface conditions. We should observe the footing subgrade prior to forming of footings. Our services do not include determining the presence, prevention or possibility of mold or other biological contaminants (MOBC) developing in the future. If the client is concemed about MOBC, then a professional in this special field of practice should be consulted. If you have any questions or need further assistance, please call our office. Sincerely, Kumar & Associates, I Daniel E. Hardin, P. Rev. by: SLP DEHlkac attachments Figures 1 and2- Swell-Consolidation Test Results Table I - Summary of Laboratory Test Results >/r>lzt Kumar & Associates, lnc. o Project No.24-7-141 I E I I g SAMPLE OF: Sondy Sllty Clcy FROM:PltloS' WC = 7,7 %, DD = 108 pcf ADDITIONAL COMPRESSION UNDER CONSTANT PRESSURE DUE TO WETTING I l i ,l .... _.:. _._...__.;-_.-___, _,.''' i..-.,-.i 1 0li j-1 LI =tn t-2 zot- 3-Joozoo_4 -5 -6 -7 I 24-7-141 Kumar & Associates SWELL_CONSOLIDATION TEST RESULTS Fig. 1 r g o SAMPLE OF: Sondy Sllty Cloy FROM:Pii2O2.5' WC = 11,6 %, DD = 106 pcf ADDITIONAL COMPRSSSION UNDER CONSTANT PRESSURE DUE TO WEfiING l hd ''' "-,'--_.' - _r" _.- _ -: - '.' t_ __ I 0x J-1lrl.Itl t_2 zo e-Ioozoo_4 -6 1.0 SWELL-CONSOLIDATION TEST RESULTS Fig. 224-7-141 Kumar & Associates g lcn lfurmr & Associates, lnc. @ Geotechnical and Materials Engineers and Environmental Scientists TABLE 1 SUilITIARY OF LABOMTORY TEST RESULTS lla. 2+7-141 2 1 PIT 2% -3 2% J m DEPT}I SAIPLE LOCATIOI{ 10.3 .611 7.7 {%} NATURAT TOSTURE coirTEhn 106 108 NATURAT DRY DENSlrY (%) GRAVEL (%) SA}ID 64 PERCENT PASSING NO. 2(nSEVE 20 MI LKIIJID LITF 5 PLASTIC INDB( l0[] ATIERBERGUTITS (D6fl UNCOf.IFINED COilPRESSNE STRENGTH Sandy Silty Clay Sandy Silty Clay Sandy silty Clay SOL TYPE