HomeMy WebLinkAboutBlower Door Test ReportInfiltration Test Field Worksheet
Test date:6/5/2024
Project name:Tesky Residence
Project address:57 Garden Cir, New Castle
Jurisdiction:Garfield
Code:2018 IECC
Architect:
General Contractor:
Test order by:Chelsey Tesky
Address:57 Garden Cir, New Castle
Send report to email:chelseytesky@gmail.com
Phone:970-208-7375
Roof/ceiling type:Vented non-conditioned
Crawlspace:unvented conditioned
Garage:NA
Category of space by floor CFA Other areas X Height =CSV
Garage x =0
Vented attics x =0
Vented crawlspace x =0
Conditioned attics x =0
Vaulted ceilings, upper floor 1 x =0
Vaulted ceilings, upper floor 2 x =0
Open to below, upper floor x =0
Upper floor 1 x =0
Upper floor 2 x =0
Vaulted ceilings, main floor 1 x =0
Vaulted ceilings, main floor 2 x =0
Open to below, main floor x =0
Main floor 1 1,592 x 9.0 =14,328
Main floor 2 x =0
Conditioned crawlspace 1 1,592 x 5.5 =8,756
Conditioned crawlspace 2 x =0
Basement level 1 x =0
Basement level 2 x =0
Total CFA (Conditioned Floor Area)1,592 Square Feet
Total CSV (Conditioned Space Volume)Cubic Feet 23,084
Temperature; Inside:72 Degrees lower outdoor temperature increases corrected flow
Temperature; Outside:70 Degrees higher outdoor temperature increases corrected flow
Elevation:5,597 FASL lower elevation decreases corrected flow
Stack height (max vertical dimension):Feet higher elevation increases corrected flow
Allowable Air Exchange Rate:3.0 ACH50
Allowable flow (sea level):1,154 CFM50 (volume/60) X allowable ACH50
Measured airflow:1,089 CFM50
Corrected airflow:1,122 CFM50*
Corrected difference:33 CFM50
Tested air exchange rate:2.9 ACH50 (corrected airflow X 60)/volume
Code compliance:PASS
Test notes: