Loading...
HomeMy WebLinkAboutBlower Door Test ReportInfiltration Test Field Worksheet Test date:6/5/2024 Project name:Tesky Residence Project address:57 Garden Cir, New Castle Jurisdiction:Garfield Code:2018 IECC Architect: General Contractor: Test order by:Chelsey Tesky Address:57 Garden Cir, New Castle Send report to email:chelseytesky@gmail.com Phone:970-208-7375 Roof/ceiling type:Vented non-conditioned Crawlspace:unvented conditioned Garage:NA Category of space by floor CFA Other areas X Height =CSV Garage x =0 Vented attics x =0 Vented crawlspace x =0 Conditioned attics x =0 Vaulted ceilings, upper floor 1 x =0 Vaulted ceilings, upper floor 2 x =0 Open to below, upper floor x =0 Upper floor 1 x =0 Upper floor 2 x =0 Vaulted ceilings, main floor 1 x =0 Vaulted ceilings, main floor 2 x =0 Open to below, main floor x =0 Main floor 1 1,592 x 9.0 =14,328 Main floor 2 x =0 Conditioned crawlspace 1 1,592 x 5.5 =8,756 Conditioned crawlspace 2 x =0 Basement level 1 x =0 Basement level 2 x =0 Total CFA (Conditioned Floor Area)1,592 Square Feet Total CSV (Conditioned Space Volume)Cubic Feet 23,084 Temperature; Inside:72 Degrees lower outdoor temperature increases corrected flow Temperature; Outside:70 Degrees higher outdoor temperature increases corrected flow Elevation:5,597 FASL lower elevation decreases corrected flow Stack height (max vertical dimension):Feet higher elevation increases corrected flow Allowable Air Exchange Rate:3.0 ACH50 Allowable flow (sea level):1,154 CFM50 (volume/60) X allowable ACH50 Measured airflow:1,089 CFM50 Corrected airflow:1,122 CFM50* Corrected difference:33 CFM50 Tested air exchange rate:2.9 ACH50 (corrected airflow X 60)/volume Code compliance:PASS Test notes: