Loading...
HomeMy WebLinkAboutApplicationGarfield County Community Development Department 108 8th Street, Suite 401 Glenwood Springs, CO 81601 lsTol s4s-82L2 www.garfield-countv.com CN contractor: Smith Mountain Builders, LLC Mailing Address: 1011 Heritage Dr, Carbondale, CO 81623 Emait Addresr. Zach@SmithMB.com r^^.bf ,"ucr 408 234-0112Phone: l BUILDING PERMIT APPLICATION WPE OF CONSTRUCTION Commercial/Multi-Family Demolition Manufactured Home or Tiny Home (Single or Multi-Level) I Residential (SF, Duplex or Townhome) sinste ramity Reroof Accessory Dwelling Unit (ADU) - MAXIMUM SIZE OF 1,200 SQUARE FEET INVOTVED PARTIES 251 767-5971Phone:Casey and Ashley Adams Email Addresr. ashley@artfuldwellings.com 322 Sopris Circle, Basalt CO 81621 Property Owner: Mailing Address: Architect: Artful Dwellings - Ashley Adams 251Phone:767-5971 Email Addresr. ashley@artfuldwellings.com Mailing Address: 322 Sopris Circle, Basalt CO 81621 DB Structural Design Ltd - Nate Decker 31 9-5934Phone: 1229 Sage Ct, Rfile, CO 81650 970Engineer: Email Addresr. nate@dbsd.com Mailing Address Phone: ( )Manufactured Home lnstaller: Mailing Address: Email Address: PROJECT DETAILS Describe *orp. Construction of a new Single Family home in the Aspen Glen Neighborhood 5ug. Roaring Fork Mesa @ Aspen Glen rot 10 Block Job Address: 435 Brookie, Carbondale, CO .254 acres Height:Sq. Ft. of Building . 3583 gross / 2950 FA Assessor's Parcel Number: 239319401010 Property Size (Sq. Ft. or Acres):Owner's Valuation of Work: 24',6-1t4"# of Floors: 2 {Class of Work:New Remodel/Alteration Addition Garage:{hed Detached PROJECT DETAILS CONTINUED Septic:fWTS I Community Type of Heat:Natural Gas Propane E lectric Other Driveway Permit: Exempt Permit # NOTICE Authoritv. This application for a Building Permit must be signed by the Owner of the property, described above, oranauthorizedagent. lfthesignaturebelowisnotthatoftheOwner,aseparateletterofauthority,signedby the Owner, must be provided with this Application. Lesal Access. A Building Permit cannot be issued without proof of legal and adequate access to the property for purposes of inspections by the Building Division, Other Permits. Multi ple separate permits may be required: (1) State Electrical Permit, (2) County OWTS Permit, (3) another permit required for use on the property identified above, e.g. State or County Highway/ Road Access or a State Wastewater Discharge Permit. Void Permit. A Building Permit becomes null and void if the work authorized is not commenced within 180 days of the date of issuance and if work is suspended or abandoned for a period of 180 days after commencement. CERTIFICATION I hereby certify that I have read this Application and that the information contained above is true and correct. I understand that the Building Division accepts the Application, along with the plans and specifications and other data submitted by me or on my behalf (submittals), based upon my certification as to accuracy. Assuming completeness of the submittals and approval of this Application, a Building Permit will be issued granting permission to me, as Owner, to construct the structure(s) and facilities detailed on the submittals reviewed by the Building Division. In consideration of the issuance of the Building Permit, I agree that I and my agents will comply with provisions of any federal, state, or local law regulatingthe work and the Garfield County Building Code, OWTS regulations and applicable land use regulations (County Regulation(s)). All County development requiring a permit, except for residential uses, are subject to Article 7 of the Land Use and Development Code. I acknowledge that the Building Permit may be suspended or revoked, upon notice from the County, if the location, construction or use of the structure(s) and facility(ies), described above, are not in compliance with County Regulation(s) or any other applicable law. I hereby grant permission to the Building Division to enter the property, described above, to inspect the work. I further acknowledge that the issuance of the Building Permit does not prevent the Building Official from: (1) requiring the correction of errors in the submittals, if any, discovered after issuance; or (2l,stopping construction or use of the structure(s) or facility(ies) if such is in violation of County Regulation(s) or any other applicable Iaw. Review of this Application, including submittals, and inspections of the work bythe Building Division do not constitute an acceptance of responsibility or Iiability by the County of errors, omissions, or discrepancies. As the Owner, I acknowledge that responsibility for compliance with federal, state and local laws and County Regulations rest with me and my authorized agents, including without limitation my architect designer, engineer and/ or builder. I hereby acknowledge that I have read and understand the Notice and Certification above, as well as, have provided the required information which is correct and accurate to the best of my knowledge. A s h I ey C I a r k Ad a m s B:n.ll?'y.;,f81, y,t",ll:Jo"llib$0"'" 5.18.24 Property Owner Print and Sign Date tOFFICIAL USE ONLY offi qh*a c/aed CO /V D / T/ 0 /V S Special Conditions: Adiusted Valuation: &/o7^/-nD Plan Check FeetL5r.1b ,\UHF.'EO Manu. Home Fee: - Misc. Fees: ntp mDSzZOi Total Fdes: ^ '3, / ?2,''i'lAilA'flo Balance Due:lqrz, tl BP No: WTE-KIA OWTS No: -lA'#tii'A- B.E, Orroro"oiRD Const. rr'"l QD ,.W,PUP BUILDING / PTANNING DIVISION :b^il-bz| Signed Approval (+h Date Cw; ENERGY COMPLIANCE SHEET REQUIREMENTS: Effective June 30, 2023 Please provide details showing how building complies / meets Garfield County's adopted 2018 IECC and Glimate Zone 5. Depict, and show outline the structure's building thermal envelope. Outline should clearly show portions of the building to be conditioned inside the envelope (and label or otherwise identify any areas remaining unconditioned outside this envelope) Energy Compliance Plan should further include: Chosen Energy Compliance Path o Prescriptive: Cross Sections of insulated assemblies including the selected material/ R-Value and U-Values to comply with IRC Table R402.1.2 . U-Factor Alternative: Provide a ResCheck Report a Total U-Factor Alternative: Provide software generated submittal design reports and inspection checklist for any RESNET ERI index or other performance path designs Air sealing details around openings, pipes, penetrations, joints Fenestration U-factors Provide mechanical system design details including proposed efficiency rates, types of equipment, fuel types, locations Energy efficient lighting specifications - 90% to be high-efficacy (LED complies) Manual J Report required for new building structures and new equipment installations. STRUCTURAL PLANS: Please provide the following information on the structural plans. r SOILS REPORT - lf the project is located in a subdivision with a final plat requiring site specific soils investigation report or if Structural plans make a specific reference to a soils report, then a copy of the soils report is required to submit a building permit application. . Design specifications to include roof and deck snow load, wind and seismic design and frost depth.. Foundation plan showing complete footing and foundation dimensions. o Footing and foundation details specifying reinforcement and referenced on plans. . Framing plans for each floor level and roof. All beams, columns, joists, rafters and trusses specified. Pre-manufactured structures require the engineers stamp, signature and date. o Framing /connection details, braced wall lines, shear wall schedule, location and hold downs. NOTE: lf any required information is missing, delays in issuing the permit are to be expected. lf determined by the Building Official that additional information is necessary to review the application and/or plans for compliance, the application may be placed on hold until the required information is provided. Work may not proceed without the issuance of a permit. The Building Division will collect a Plan Review fee at time of application submittal. The permit fee, as well as any Road lmpact fees will be collected when the permit is issued. The permit application must be signed by the owner or by person having written authority from the owner to act as their representative. Building cannot be occupied until a Certificate of Occupancy (CO) is issued. Using the building without a CO will be considered an illegal occupancy and may be grounds for vacating the premises. (Final/CO inspection requirements will be attached to your approved field set of plans.) I hereby acknowledge I have read, understand and will abide by the requirements of this checklist. Owner print: Ashley Adams D:4ldl/s'grr!o/ A h'eyCa,l Ashlev Clark Adams Ad:h'Sign: - -' - - -- - o"" '''*'"'"uo'** p61g 5.18.24 'i BU'LDING DEPARTMENT 7A8 Eighth Saeet, Suite 4o1, Glenwood Springs, Co 87ffi7 Tel: (970) %s-8212 PLAN REVIEW CHECKLIST Permit No: BLRE-Ar-Z( -867/ Garfield County Building lssues 4/ ./ f ^tn K*4 &,o-z-47q 5VL e5,.u2D Pla n ning/Zoning lssues lu-/o 3to9atre -ane d, Engineered Foundation Driveway Permit Surveyed Site Plan aM_ Septic Permit and Setback t N A 1 f ',lD euitJine Hbight 4t,/ - / Property Line Setbacks 35 ft. Stream Setbacks Flood Plain Zoning Sign-Off Road lmpact Fees Grade/ Topography u10% Planning lssues Grade/ Topography 30% Attach Residential Plan Review List Subdivision Plat Notes 1b?oo W .f RF€. Fire Deoartment Review w;l:,A+;resfunP Val uation Determ ination/ Febs Red Line Plans/ Stamps/ Sticker Attach Conditions Application Signed Plan Reviewer to Sign Application Parcel/schedule No. 40# Snowload Letter - Manu. Hom t/ subdivision Plat 5oo17/ Descriotion & Summarv: r/S Q?SOx 7/,bg 2ZO) fu6:o cru,u/ t3/5x /8 a42zlo.oO ?jtr /85 y 3z tq52O, Absoits Report ./4 alz )< / g 5) blb, oo OD "T/'/ /o/ x /z-? b6.oo 'ugtb/ bu ,//rn7 0pHhl-t"{0t-E sOtts RHPSRT IS F{HSUIREN AT N:OOTII'IG !N$PH0T[Qri= 4a.82 *P*F eb'fro/* # zbf) b20, oaa, n/aah on.'