Loading...
HomeMy WebLinkAboutEngineer's Foundation Letter 06.14.24 June 14, 2024 Brad Jordan, AIA Jordan Architecture Inc PO Box 1031 Glenwood Springs, Colorado 81601 (970) 618-6690 bradjordanarchitect@gmail.com RE: ICF Header Beam Reinforcing Stirrups Lot 12 Rapids On The Colorado, New Castle, Colorado ESD Project Number: 23.078C Brad, At the request of the contractor, we reviewed the alternate of using #3 ā€œSā€ shaped stirrups in lieu of the typical closed loop stirrups. It is our understanding that due to the construction constraints with ICF walls, closed loop stirrups cannot be installed and therefore not a feasible option. Upon our review of the headers, we determined that the structural design is adequate with #3 single-leg ā€œSā€ stirrups with ACI standard hooks at the spacing as specified per the Rev 3 structural set, dated 12/11/2023. Should you have any further questions regarding this matter, please feel free to contact our office. Sincerely, Evolve Structural Design LLC Christopher Bridges, P.E. Project Manager 06/14/2024