HomeMy WebLinkAboutEngineer's Foundation Letter 06.14.24
June 14, 2024
Brad Jordan, AIA
Jordan Architecture Inc
PO Box 1031
Glenwood Springs, Colorado 81601
(970) 618-6690
bradjordanarchitect@gmail.com
RE: ICF Header Beam Reinforcing Stirrups
Lot 12 Rapids On The Colorado, New Castle, Colorado
ESD Project Number: 23.078C
Brad,
At the request of the contractor, we reviewed the alternate of using #3 āSā shaped stirrups in lieu of the typical
closed loop stirrups. It is our understanding that due to the construction constraints with ICF walls, closed loop
stirrups cannot be installed and therefore not a feasible option. Upon our review of the headers, we
determined that the structural design is adequate with #3 single-leg āSā stirrups with ACI standard hooks at the
spacing as specified per the Rev 3 structural set, dated 12/11/2023.
Should you have any further questions regarding this matter, please feel free to contact our office.
Sincerely,
Evolve Structural Design LLC
Christopher Bridges, P.E.
Project Manager
06/14/2024