HomeMy WebLinkAboutFraming DetailsCreated using Plan Analyst software by Plan Analyst LLC www.PlanAnalyst.com i Reaction LL =650 lbs DL =162.5 lbs TL =812.5 lbs Reaction LL =650 lbs DL =162.5 lbs TL =812.5 lbs Min bearing =1.5 in Min Bearing =1.5 in Based on the 2021 IBC/IRC and NDS-18 Based on top edge having continuous lateral support. lncrease in allowable for duration of load =0%DEFLECTION: L/180 = .4333 Ll24O =.325 U360 =.2167 L1480 =.1625 Total Load Deflection = .1197" - L1652 Live Load Deflection = .0958" - L1814 Deflection OK for floors and roofs BENDING ALLOWED = 18717.2 inch/lbs ACTUAL = 15843.8 inch/lbs Bending ratio = 84.60/o of the allowable Bending OK SHEAR: - No increase used ALLOWED =2823.3 pounds ACTUAL = 697.9 pounds Shear ratio = 24.7% of the allowable Shear OK 200plf LL 50plf DL T>4Garfield County Building Department 108 Eighth Street#401 (970) 945-1377 Beam lD