Loading...
HomeMy WebLinkAboutBlower Door TestTesting Company: Name:Energy Pro Address:2892 I70B Grand Junction, CO 81501 Phone: 970 623 7327 trent@energyproservices.com Technician: Name:Dennis Patterson Credentials: Email:dennispatt27@gmail.com Building Information: Project ID:SCIB LLC Address:210 Blue Heron Dr Lot 38 Glenwood Springs, CO 81601 Year Built:2024 Geo-Tag Data:Latitude: Longitude: Timestamp: Customer Information: Name:SCIB LLC Address:115 Boomerang Rd Suite 5201B Aspen, CO 81611 Phone: 512/673/3867 Email: michael.price@sunriseco.com Measured Leakage:2.02 ACH50 Leakage Target:3.00 ACH50 Compliance with Leakage Target:Pass Test ID:210 Blue Heron Dr lot 38 Purpose of Test:IECC 12/15 Env. Leakage Measured CFM50:1,209.4 Effective Leakage Area: 66.5 in² Building Volume:35,841.0 ft³Enclosure Surface Area: 3,425.0 ft² Coefficient (C):95.1 Exponent (n): 0.650 (assumed) Test Standard:RESNET 380 One-Point Test Mode: Depressurize Test Characteristics:Indoor Temp: 79 °F Altitude: 5,883.0 ft Outdoor Temp: 79 °F Time Average Period: 30 seconds Test Date and Time:2024-06-10 12:26:50 Envelope Leakage Test Test Readings: Target (Pa)Bldg (Pa)Adj Bldg (Pa)Fan (Pa)Flow (cfm)Config Baseline -0.4 -50.0 -51.1 -50.7 -41.8 1,173.3 Ring A Test Equipment: Flow Device:Model 3 110V Fan Pressure Gauge:DG1000 Serial #: 14229 Calibration Date: 2023-06-14 Deviations from Standard: None Comments: None Envelope Leakage Test Page 2 of 2Report by TEC Auto Test 1.9.1 (8), © 2023 The Energy Conservatory, Inc.