Loading...
HomeMy WebLinkAboutHers Rating Score 1Property 2015 IECC R-406 RESNET Registered Energy Rating Index Report Organization Builder:Arch: Axis Company:Confluence Architecture Address: Phone:970-963-9720 55 Horseshoe Lane, Glenwood Springs, CO Rater:Mark McLain 81623 _-_ More Energy 150 Existing i40 Homes 130 120 uo Reference Home 100 90 80 70 60 S0 40 30 20 Zero Energy Home to This Home o Less Energy RESXEi Energy Rating Index Information RESNET Registered Rating Rating No:699952056 Date Rated:2024-03-08 Rater ID (RTIN):9920829 Estimated Annual Energy■ • • Rated Home Calculated Energy Use (MBtu) Rated Home Cost ($lyr) Heating 75.2 $ 762 Cooling 0.2 $7 Water Heating 39.7 $438 Lights &Appliances 27.3 $876 Photovoltai cs -40.5 -$906 Service charge - $642 Total I 101.8 I $1,819 'Eased on standard operating conditions ERI with PV:25 ERI without PV:58 Electric (kWh):7,550.3 CO2 Emissions (Tons):2.6 Natural Gas (Therms):1,166.0 Energy Savings ($)**:NIA "Eased on the 2015 1 ECC R-406 Reference design home PASS This home MEETS the Energy Rating Index Score requirement of 2015 IECC R-406 for Climate Zone 5. It MEETS all of the requirements verified by Ekotrope. Mandatory requirements are summarized on the 2nd page of this report, some of which are not verified by Ekotrope. Name: Mark McLain Signature: �r Organization: Confluence Architecture Company:Deeper Green Consulting Address:101 W. Main Street, Frisco, CO 80443 Phone #:970-471-4298 Fax #: Digitally signed: 5/20/24 at 10:44 AM ?��JyvRTGAG� IM1,Q_ x 202 . •.. cR Or7ATrQN To determine if a provider is properly accredited go to: www.resnet.us/professional/programs/search_directory (Confirmed and tested) Provision Number Topic Compliance Decision Pass 2009 IECC Table 402.1.1 or Building thermal envelope minimum insulation levels and maximum 402.1.3 fenestration U-factor and SHGC R401.3 Post a permanent certificate listing the level of efficiencies installed in Certificate required for CO the house R402.4.1.2 Envelope air leakage maximum leakage rate Pass R402.4.1 /Table R402.4.1.1 Complywith air sealing and insulation requirements in Table Checklist required for CO R402.4.1.1 R402.4.4 Rooms containing fuel -burning appliances Pass* R402.5 Maximum fenestration U-factorand SHGC {U-Factor} Pass {SHGC} Pass R403.1.2 Heat pump controls Pass* R406.2 Ducts outside of conditioned space to be insulated to a minimum of Pass* R-6. R403.3.2 Duct sealing on all ducts Pass* R403.3.3 Duct testing for ducts in unconditioned space PASS R403.3.5 Building cavities not used as ducts. Pass* R403.5.1 Heated water circulation and temperature maintenance systems Pass* comply R403.5.3 Hot water pipe insulated to R-3 Fail R403.6 Mechanical ventilation meeting the requirements of the IRC or IMC. Pass* Outdoor air and exhaust dampers installed R403.7 ACCA Manual J and S Conducted for all heating and cooling systems. ACCA forms required for permit R403.8 Systems serving multiple dwelling units to meetthe mechanical Pass* requirements of IECC commercial code R403.9 Snow melt and ice system controls installed where applicable Pass* R403.10 Pools and permanent spa energy consumption meet requirements Pass* far heaters, time clocks and covers R403.11 Portable spas meet the requirements of APSP-14. Pass* R404.1 High efficacy lights installed in 75°/0 of permanently installed fixtures. Pass *These items have been field -verified by the Rater, Field Inspector, Code Inspector, or Builder Ekotrope RATER - Version 4.1.0.3403 IECC 2015 ERI compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RES NET Accredited HERS Rating Tool. All resu Its are based on data entered by Ekotrope users. Ekotrope disclaims all I iab i l ity for the information shown on this report. IECC 2015 Building UA Compliance Property 55 Horseshoe Lane Glenwood Springs, CO 81623 55 Horseshoe Lane Confirmed organization Confluence Architecture Mark McLain 970-963-9720 Builder Arch: Axis Elements Ceilings Above -Grade Walls Windows, Doors and Skylights Slab Floor: Framed Floors Foundation Walls Rim Joists Overall UA (Design must be equal or lower): Building UA Inspection Status 2024-03-08 Rater ID (RTIN): 9920829 RESNET Registered (Confirmed) Requirements IECC Reference 70.1 165.3 221.1 43.6 20.7 65.9 11.0 597.7 ® R402.15 Total UA alternative compliance passes by 27.2%. The proposed home meets the UA requirement by27.2% ® R402.3.2 Glazed Fenestration SHGC 4 R402A.1.2 Air LeakageTesting Airsealing is 2.97 ACH at 5fl Pa. It must not exceed 3.00 ACH at 50 Pa. As Designed 49.1 115.3 166.1 41.9 23.9 31.2 7.7 435.0 ® R402.5 Area weighted average fenestration SHGC Area -weighted average fenestration SHGC is 0.23.The maximum allowed value is [No Limit]. R4025 Area -weighted average fenestration U-Factor ® R404.1 Lighting Equipment At least 75.0% offixtures shall be high -efficacy lamps, currently 100.0%are high -efficacy. 11403.6.1 Mechanical Ventilation Efficacy Mandatory Checklist Mandatory code requirements that are not checked 2015 IECC Mandatory Checklist must be checked as complete. by Ekotrope must be met. R403.3.4 Duct Leakage Testing R403.5.3 Hot water pipe insulation Hot water pipes at least 314 in diameter must be insulated to R-3 at minimum. Design exceeds requirements for IECC 2015 Prescriptive compliance by 27.2%. Name: Mark McLain Signature: /� r Organization: Confluence Architecture Digitally signed: 5/20/24 at 10:44 AM Ekotrope RATER - Version 4.1.0.3403 IECC2015 Prescriptive compliance results calculated using Ekotrope RATE Ts energy and code compliance algorithm. Ekotrope RATER is a RES MET Accredited HERS Rating Tool. All resultsare based on data entered by Ekotrope users. Ekotrope disclaims all I iab i l ity for the information shown on this report. Building Specification Summary Property 55 Horseshoe Lane Glenwood Springs, CO 81623 55 Horseshoe Lane Confirmed Building Information Conditioned Area [ft2] Conditioned Volume [ft3] Thermal Boundary Area [ftz] Number Of Bedrooms Housing Type organization Confluence Architecture Mark McLain 970-963-9720 Builder Arch: Axis 3,471.00 42,779.00 10,090.00 4 Single family detached Building Shell Ceiling w/Attic I Attic vented ceiling R60 3; U-0.017 Vaulted Ceiling Rafter unvented R41 flash & R19 batt + RO Cl 3; U-0.031 Above Grade Walls I R23 cavity + R6 CI 3; U-0.04 Found. Walls I RI + RI drape; R-34 Framed Floors I R38 between living &garage batt 3; R-38 Slabs I RI edge + RO under, R-15 Mechanical Systems Heating Cooling Water Heating Programmable Thermostat Ventilation System Whole House Fan Lights and Appliances Percent Interior LED Percent Exterior LED Refrigerator (kWh/yr) Dishwasher Efficiency Ceiling Fan Inspection Status 2024-03-08 Rater ID (RTIN): 9920829 RESNET Registered (Confirmed) Rating HERS ERI HERS ERI w/o PV 25 58 Windows (largest) I U-Value: 0.23, SHGC: 0.23 Window / Wall Ratio 10.18 Window/ Floor Ratio 10.18 Infiltration 12.97 ACH50 Duct Lkg to Outside I Radiant Total Duct Leakage I Untested Boiler • Natural Gas • 95 AFUE Air Source Heat Pump • Electric • 19.7 SEER2 Boiler • Natural Gas • 0.85 Energy Factor Yes 20 CFM • 20 Watts (Default) • ERV NIA 100% Clothes Dryer Fuel Electric 100% Clothes Dryer CEF 3.9 1,071.0 Clothes Washer LER (kWh/yr) 85.0 240 kWh Clothes Washer Capacity 3.0 None Range/Oven Fuel Natural Gas Ekotrope RATER - Version 4.1.0.3403 All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. Building Summary Property 55 Horseshoe Lane Glenwood 5prin9s, CO 81623 55 Horseshoe Lane Confirmed ■ General Building Information N umbe r Of Bedrooms Number Of Floors Conditioned Floor Area [sq. ft.] Has Electric Vehicle Ready Space Unconditioned, attached garage? Conditioned Volume [cu. ft.] Total Units in Building Residence Type Number of Floors in Building Floor Number Model Community RESNETIIECC 2006-2018 Climate Zone IECC2021 CIimate Zone Organization Inspection Status Confl uence Architecture 2024-03-00 Mark McLain Rater ID (RTIN):9920829 970-963-9720 RESNET Registered [Confirmed] Builder Arch: Axis 4 2 3,471 No Yes 42,779 1 Single family detached 5B 5B ■ Foundation Wall Name LibraryType Height Above Grade Depth Below Grade Perimeter Location Enclosing Basement Wall R15+RI9drape 3.7 80 0.5 Exposed Exterior Conditioned Space CrawlspaceWall R15+R19drape Exposed Exterior ConditionedCrawlspace 0.5 2.5 181 Foundation Wall Library List Name Feet From Wall Top To Feet From Wall Top To Is Fully Insulated Continuous R-value Cavity R-value Effective Insulation R- Continuous Insulation Continuous Insulation value Top Bottom R 15 + RI 9d ra pe NIA N/A Yes 34.00 NIA N/A Name LibraryType Perimeter Floor Grade Carpet R Exposed Masonry Area Surface Area Location Enclosing Basement S I a a R15 edge+ R10 8o Below Grade 0 0 369.0 ft' Exposed Exterior Conditioned Space under Crawlspace S I a a R15 edge +RO 191 Below Grade 0 0 1A31.0 ft' Exposed Exterior Conditioned under Crawlspace 1 Building Summary Property Organization Inspection Status V V 11 1 1 V V Ill V V 55 Horseshoe Lane ConfluenceArchitecture 2024-03-00 Glenwood 5prings,CO 81623 Mark McLain Rater ID (RTIN):9920829 970-963-9720 RESNET Registered [Confirmed] 55 Horseshoe Lane Confirmed Builder Arch: Axis Slab Library List Name Wall Construction Slab Completely Underslab Perimeter Perimeter Perimeter Thermal Break Effective R-value Type Insulated' Insulation Width Insulation Depth Insulation R Value Insulation Is /t] /t] Exterior R15 edge+ RO under Wood Frarnel No 20 4 15 Yes No 0,00 Other R1 5 edge + RI O under Wood Frame I No 20 4 15 Yes Yes 10,00 other Framed Floor Name LibraryType Carpet R Floor Over Garage R38 between livin g & g a ra g e Batt 3 Framed Floor Library List Name Effective R•value R38 between living & garage batt3 26,276 Rim Joist Name Rim Ri rn - Garage Rim Joist Library List Name R 21.0 R 27.0 ry'rype Above Grade Area 626,0 ft Unconditioned, attached garage R 27.0 204,O ft Exposed Exterior R 21.0 Effective Insulation R-value 21.00 27.00 34,Oft Unconditioned, attached garage 2 Building Summary Property Organization Inspection Status V V 11 1 1 V V I] V V 55 Horseshoe Lane ConfluenceArchitecture 2024-03-00 Glenwood 5prings,CO 81623 Mark McLain Rater ID (RTIN):9920829 970-963-9720 RESNET Registered [Confirmed] 55 Horseshoe Lane Confirmed Builder Arch: Axis Name LibraryType Surface Color Surface Area Location Garage Wall R21 cavity garage 3 Medium 152.0 ft Unconditioned, attached garage Knee Wall RI cavity knee 3 Medium 11.0 ft, Attic Wall R23 cavity +R6 Cl 3 Mediurn 3,283.0 ft' Exposed Exterior Wall Library List Name Effective R-value RI cavity knee 3 11.185 R21 cavity garage 3 14.429 IR23 cavity + R6 Cl 3 24,802 1 Glazing Name Library Type Wall Foundation Wall Is Operable Overhang Overhang Ft To Overhang FtTo Orientation Surface Area Assignment Assignment Depth Top Bottom East-1 .231.23 Wall Yes 1 1 6.2 Southeast 32.0ft East -13 .231.23 Wall Yes 1 1.5 9 Southeast 18.0ft' East -17 .231.23 Wall Yes 1 7 12.8 Southeast 28.0ft East-2 .231.23 Wall Yes 1 17 22 Southeast 28.0ft East-4 .231.23 Wall Yes 1 2.0 6.8 Southeast 9.0ft East - Entry Sidelight .231.23 Wall Yes 9 2.5 9.5 Southeast 8.0ft North - 11 .231.23 Wall Yes 1 4.75 12.3 Northeast 36.0ft North -12 .23423 Wall Yes 1 4.75 12.3 Northeast 36.0ft North -16 .231.23 Wall Yes 1 1.5 6.8 Northeast 2TOft South - IS .231.23 Wall Yes 1 1 6.5 Southwest 28.0 ft' South - 19 .231.23 Wall Yes 1 6.5 12 Southwest 28.0ft' South - 20 .231.23 Wall Yes 1 4.8 10 Southwest 28.0 ft' 3 Building Summary Property Organization Inspection Status V V 11 1 1 V V 11 V V 55 Horseshoe Lane ConfluenceArch itectuire 2024-03-00 Glenwood 5prin9s,CO 81623 Mark McLain Rater ID (RTIN):9920829 970-963-9720 RESNET Registered [Confirmed] 55 Horseshoe Lane Confirmed Builder Arch: Ax s Name Library Type Wall Foundation Wall Is Operable Overhang Overhang Ft To Overhang FtTo Orientation Surface Area Assignment Assignment Depth Top Bottom South - 3 .231.23 Wall Yes 1 19 23 Southwest 8.0 ft South - 5 .231.23 Wall Yes 1 1 5 Southwest 10.0 ft South - 6 .231.23 Wall Yes 1 1 5 Southwest 8.0 ft South - E .231.23 Wall Yes 1 2.5 9 Southwest 15.0 ft West-10 .231.23 Wall Yes 1 1.5 8.8 Northwest 19.Oft West - 21 .231.23 Wall Yes 1 4.5 10 Northwest 11.0 ft West - 22 .23423 Wall Yes 1 4,5 10 Northwest 28.0 ft West-7 .231.23 Wall Yes 1 13.5 18.3 Northwest 11.0ft West-8 .231.23 Wall Yes 1 1 6.5 Northwest 41.Oft West - 9 .231.23 Wall Yes 1 1.5 8.8 Northwest 66.0 ft West -F .231.23 Wall Yes 16 6 15 Northwest 112.0ft Glazing Library List Name C.23 0,230 Skylight None Present Skylight Library List None Present 4 Building Summary Property Organization 55 Horseshoe Lane ConfluenceArchitecture Glenwood 5prings, CO 81623 Mark McLain 970-963-9720 55 Horseshoe Lane Confirmed Builder Arch: Axis paque Door Name LihraryType Wall Assignment Foundation Wall Assign ment Entry Door 2-1/4 Woad solid Wall core Garage 2-1/4 Woad solid Garage Wall Opaque Door Library List Name Effect! 2-1/4 Wood solid core Roof Insulation Name LihraryType Attic ExtericrArea M Clay or Concrete Roof Tiles Roof - Sloped Attic vented ceiling R60 3 3,000 No Inspection Status 2024-03-00 Rater ID (RTIN):9920829 RESNET Registered [Confirmed] nce Area 0.9 0.75 Medium 30.0 ftExposed Exterior 0.9 0.75 Medium 26.0ft' Unconditioned, attached garage Roof - deck Rafter unvented R41 flash &R19 Batt+ RO CI 3 Roof Insulation Library List Name J" Has Radiant Barrier Attic vented ceiling R603 No Rafter unvented 13,41 flash No &R19 haft + RO CI 3 Whale House Infiltration ' Infiltration Measurement Type 2.97 ACH at 50 Pa Blower -door tested 2,80 Color Surface Area Location Dark 2,460.0 ft Attic 237 No Dark 237.0 ft Vaulted Roof 58A49 32.24 Shelter Class 4 5 Building Summary Property Organization 55 Horseshoe Lane ConfluenceArchitecture Glenwood 5prin9s, CO 81623 Mark McLain 970-963-9720 55 Horseshoe Lane Confirmed Builder Arch: Axis Inspection Status 2024-03-00 Rater ID (RTIN):9920829 RESNET Registered (Confirmed) Mechanical Ventilatio Ventilation Type Ventilation Rate [ft'1 Operational hours Fan Watts Runs anceevery Energy Recovery Minute] perday three hours Percent ERV 20 CFM 24 20 Watts (Default) Yes 66 I Manufacturer Lighting ?� Interior Fiuorescent %Interior LED Lighting % Exterior Fluorescent ?6 Exterior LED Lighting ?6 Garage Fluorescent %Garage LED Lighting Lighting Lighting Lighting 0 100 0 100 0 100 Onsite Generation w None Present Onsite Generation Library List i None Present Solar Generation Index Track Mode Nameplate Capacity (kWdd De rate Factor Fixed 2.9 kW 2 Fixed 2.8 kW Dehumidifier Fixed 1.6 kW None Present 0.83 191, AB. 0.83 191, Q. 0.77 191, 18° Building Summary Property 55 Horseshoe Lane Glenwood 5prings, CO 81623 55 Horseshoe Lane Confirmed ■ Dehumidifier Library List Whole House Fan Whole House Fan Library List Conditioning Equipment I Name LibraryType Cooling ASHP40.5 KBtu 5EER2 19.70 HSPF2 92 Cooling 2 ASHP40.5 KBtu SEER2 19.70 HSPF2 92 Organization Confl uence Architecture Mark McLain 970-963-9720 Builder Arch: Axis None Present one None Present Number Heatina Percent ED of III on P0 Inspection Status 2024-03-00 ' Rater ID (RTIN):9920829 RESNET Registered [Confirmed] Percent Load Hat Water Percent 0% 50% 0% Conditioned Space 0% 50% 0% Conditioned Space Heating Boiler 134, Rad,+water 100% heating Equipment Type: ASHP 40.5 KBtu SEER2 19.70 HSPF2 9.2 Equipment Type Air Source Heat Pump Fuel Type Electric Distribution Type Forced Nr Motor Type ECM [Variable Speed] Heat Pump 5ystemType Split System Cooling Efficiency 19.75EER2 Cooling Capacity [kBtufh] 40.5 0% 100% Conditioned Space 7 Building Summary Property Organization 55 Horseshoe Lane CDnfl uence Architecture Glenwood 5prin9s, CO 81623 Mark McLain 970-963-9720 55 Horseshoe Lane Confirmed Builder Arch: Axis ■ Equipment Type: Boiler 184, Rad, f water heating Equipment Type Boiler Fuel Type Natural Gas Distribution Type Radiant Heating Efficiency 95 AFUE Heating Capacity EkEtufh] 184 Use default EAE Yes EAE [kWh] 170 Hot Water Efficiency 0.85 Energy Factor Tank Capacity (gal.) 55 Hot Water Capacity [kBtulhl 160 Recovery Efficiency 0.95 ■ Distribution System Distribution Type Heating Equipment Is All Equipment In Conditioned Space Leakage Default Duct System Efficiency Distribution System Distribution Type Cooling Equipment Is All Equipment In Conditioned Space Leakage Default Duct System Efficiency Radiant Heating Yes HERS Default Leakage 1 Forced Air Ductless Cooling Yes HERS Default Leakage 1 ED of III on P0 Inspection Status 2024-03-00 ' Rater ID (RTIN):9920829 RESNET Registered [Confirmed] Distribution System Distribution Type Forced Air Ductless Cooling Equipment Cooling 2 Is All Equipment In Conditioned Space Yes Leakage Default HERS Default Leakage Duct System Efficiency 1 HVAC Grading HVAC Grading Not Conducted ■ - Ceiling Fan Has Ceiling Fan No 8 Building Summary Property 55 Horseshoe Lane Glenwood 5prings, CO 81623 55 Horseshoe Lane Confirmed Water Fixture Type Use Default Hot Water Pipe Length Hot Water Pipe Length [ft] At Least R3 Pipe Insulation? Hot Water Recirculation System? Hot Water Branch Length [ft] Recirculation System Control Recirculation Pump Power [Watts] Shared? Recirculation System Pipe Loop Length [ft] Drain Water Heat Recovery? ■ Clothes Dryer Cef Fuel Type Field Utilization Is Outside Conditioned Space Clothes Dryer Available Defaults Type rclothes Washer Label Energy Rating Annual Gas Cost Electric Rate Gas Rate Capacity Imef Defaults Type Load Type Loads Per Week Is Outside Conditioned Space Clothes Washer Available ishwasher I shwasher DefauItsType shwasher Size shwasher Efficiency nual Gas Cost ctric Rate s Rate Outside Conditioned Space shwasherAvailable ED of III P0 Organization Inspection Status Confl uence Architecture 2024-03-00 Mark McLain Rater ID (RTIN):9920829 970-963-9720 RESNET Registered [Confirmed] Builder Arch: Axis Low -flow No 75 No Yes 8 None or Timer Control 50 No 150 No 3.93 Electric Moisture 5ensing No Yes Custom 85 kWh/Year $27.00 $0.121kWh $1.091Therm 3 2.92 Custom Front -load 6 No Yes Custom Standard 240 kWh $33.12 $0.121kWh $1.091Therm No Yes 9 Building Summary Property 55 Horseshoe Lane Glenwood 5prin9s, CO 81623 55 Horseshoe Lane Confirmed Appliances and Controls Programmable thermostat? Range/Oven Fuel Convection Oven? Induction Range? Range/Oven Outside Conditioned Space? Refrigerator Consumption Refrigerator Outside Conditioned Space? Notes Organization Inspection Status Confl uence Architecture 2024-03-00 Mark McLain Rater ID (RTIN):9920829 970-963-9720 RESNET Registered [Confirmed] Builder Arch: Axis Yes Natural Gas No No No 1,071 kWh/Year No Assembly numbers correspond to numbers on SketchUp model of thermal envelope. Goal: 2021 IECC Prescriptive & 2015 ERI 55 Original model by: Amanda Poindexter 3774492 Rough inspection skipped. Final inspection completed by: Chris Taylor RFIIN #CY5MPL Rater of record: Mark McLain 9920829 10