HomeMy WebLinkAboutHers Rating Score 1Property
2015 IECC R-406 RESNET Registered
Energy Rating Index Report
Organization
Builder:Arch: Axis Company:Confluence Architecture
Address: Phone:970-963-9720
55 Horseshoe Lane, Glenwood Springs, CO Rater:Mark McLain
81623
_-_
More Energy
150
Existing
i40
Homes
130
120
uo
Reference
Home
100
90
80
70
60
S0
40
30
20
Zero Energy
Home
to This Home
o
Less Energy
RESXEi
Energy Rating Index Information
RESNET Registered Rating
Rating No:699952056
Date Rated:2024-03-08
Rater ID (RTIN):9920829
Estimated Annual Energy■
• •
Rated Home Calculated
Energy Use (MBtu)
Rated Home Cost ($lyr)
Heating
75.2
$ 762
Cooling
0.2
$7
Water Heating
39.7
$438
Lights &Appliances
27.3
$876
Photovoltai cs
-40.5
-$906
Service charge
-
$642
Total
I 101.8
I $1,819
'Eased on standard operating conditions
ERI with PV:25
ERI without PV:58
Electric (kWh):7,550.3 CO2 Emissions (Tons):2.6
Natural Gas (Therms):1,166.0 Energy Savings ($)**:NIA
"Eased on the 2015 1 ECC R-406 Reference design home
PASS
This home MEETS the Energy Rating Index Score requirement of 2015 IECC R-406 for Climate Zone 5. It MEETS all of the
requirements verified by Ekotrope. Mandatory requirements are summarized on the 2nd page of this report, some of
which are not verified by Ekotrope.
Name: Mark McLain Signature: �r
Organization: Confluence Architecture
Company:Deeper Green Consulting
Address:101 W. Main Street, Frisco, CO 80443
Phone #:970-471-4298
Fax #:
Digitally signed: 5/20/24 at 10:44 AM
?��JyvRTGAG� IM1,Q_
x 202
. •.. cR Or7ATrQN
To determine if a provider is properly accredited go to: www.resnet.us/professional/programs/search_directory
(Confirmed and tested)
Provision Number
Topic
Compliance Decision
Pass
2009 IECC Table 402.1.1 or
Building thermal envelope minimum insulation levels and maximum
402.1.3
fenestration U-factor and SHGC
R401.3
Post a permanent certificate listing the level of efficiencies installed in
Certificate required for CO
the house
R402.4.1.2
Envelope air leakage maximum leakage rate
Pass
R402.4.1 /Table R402.4.1.1
Complywith air sealing and insulation requirements in Table
Checklist required for CO
R402.4.1.1
R402.4.4
Rooms containing fuel -burning appliances
Pass*
R402.5
Maximum fenestration U-factorand SHGC
{U-Factor} Pass
{SHGC} Pass
R403.1.2
Heat pump controls
Pass*
R406.2
Ducts outside of conditioned space to be insulated to a minimum of
Pass*
R-6.
R403.3.2
Duct sealing on all ducts
Pass*
R403.3.3
Duct testing for ducts in unconditioned space
PASS
R403.3.5
Building cavities not used as ducts.
Pass*
R403.5.1
Heated water circulation and temperature maintenance systems
Pass*
comply
R403.5.3
Hot water pipe insulated to R-3
Fail
R403.6
Mechanical ventilation meeting the requirements of the IRC or IMC.
Pass*
Outdoor air and exhaust dampers installed
R403.7
ACCA Manual J and S Conducted for all heating and cooling systems.
ACCA forms required for permit
R403.8
Systems serving multiple dwelling units to meetthe mechanical
Pass*
requirements of IECC commercial code
R403.9
Snow melt and ice system controls installed where applicable
Pass*
R403.10
Pools and permanent spa energy consumption meet requirements
Pass*
far heaters, time clocks and covers
R403.11
Portable spas meet the requirements of APSP-14.
Pass*
R404.1
High efficacy lights installed in 75°/0 of permanently installed fixtures.
Pass
*These items have been field -verified by the Rater, Field Inspector, Code Inspector, or Builder
Ekotrope RATER - Version 4.1.0.3403
IECC 2015 ERI compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RES NET Accredited HERS Rating Tool. All resu Its are based on data entered by Ekotrope users.
Ekotrope disclaims all I iab i l ity for the information shown on this report.
IECC 2015 Building UA Compliance
Property
55 Horseshoe Lane
Glenwood Springs, CO 81623
55 Horseshoe Lane
Confirmed
organization
Confluence Architecture
Mark McLain
970-963-9720
Builder
Arch: Axis
Elements
Ceilings
Above -Grade Walls
Windows, Doors and Skylights
Slab Floor:
Framed Floors
Foundation Walls
Rim Joists
Overall UA (Design must be equal or lower):
Building UA
Inspection Status
2024-03-08
Rater ID (RTIN): 9920829
RESNET Registered
(Confirmed)
Requirements
IECC Reference
70.1
165.3
221.1
43.6
20.7
65.9
11.0
597.7
® R402.15 Total UA alternative compliance passes by 27.2%. The proposed home meets the UA requirement by27.2%
® R402.3.2 Glazed Fenestration SHGC
4 R402A.1.2 Air LeakageTesting Airsealing is 2.97 ACH at 5fl Pa. It must not exceed 3.00 ACH at 50 Pa.
As Designed
49.1
115.3
166.1
41.9
23.9
31.2
7.7
435.0
®
R402.5
Area weighted average fenestration SHGC
Area -weighted average fenestration SHGC is 0.23.The maximum allowed value is [No
Limit].
R4025
Area -weighted average fenestration U-Factor
®
R404.1
Lighting Equipment
At least 75.0% offixtures shall be high -efficacy lamps, currently 100.0%are high -efficacy.
11403.6.1
Mechanical Ventilation Efficacy
Mandatory Checklist
Mandatory code requirements that are not checked
2015 IECC Mandatory Checklist must be checked as complete.
by Ekotrope must be met.
R403.3.4
Duct Leakage Testing
R403.5.3
Hot water pipe insulation
Hot water pipes at least 314 in diameter must be insulated to R-3 at minimum.
Design exceeds requirements for IECC
2015 Prescriptive compliance by 27.2%.
Name:
Mark McLain
Signature: /� r
Organization:
Confluence Architecture
Digitally signed: 5/20/24 at 10:44 AM
Ekotrope RATER - Version 4.1.0.3403
IECC2015 Prescriptive compliance results calculated using Ekotrope RATE Ts energy and code compliance algorithm.
Ekotrope RATER is a RES MET Accredited HERS Rating Tool. All resultsare based on data entered by Ekotrope users.
Ekotrope disclaims all I iab i l ity for the information shown on this report.
Building Specification Summary
Property
55 Horseshoe Lane
Glenwood Springs, CO 81623
55 Horseshoe Lane
Confirmed
Building Information
Conditioned Area [ft2]
Conditioned Volume [ft3]
Thermal Boundary Area [ftz]
Number Of Bedrooms
Housing Type
organization
Confluence Architecture
Mark McLain
970-963-9720
Builder
Arch: Axis
3,471.00
42,779.00
10,090.00
4
Single family detached
Building Shell
Ceiling w/Attic I Attic vented ceiling R60 3; U-0.017
Vaulted Ceiling
Rafter unvented R41 flash & R19 batt + RO Cl 3; U-0.031
Above Grade Walls I R23 cavity + R6 CI 3; U-0.04
Found. Walls I RI + RI drape; R-34
Framed Floors I R38 between living &garage batt 3; R-38
Slabs I RI edge + RO under, R-15
Mechanical Systems
Heating
Cooling
Water Heating
Programmable Thermostat
Ventilation System
Whole House Fan
Lights and Appliances
Percent Interior LED
Percent Exterior LED
Refrigerator (kWh/yr)
Dishwasher Efficiency
Ceiling Fan
Inspection Status
2024-03-08
Rater ID (RTIN): 9920829
RESNET Registered
(Confirmed)
Rating
HERS ERI
HERS ERI w/o PV
25
58
Windows (largest) I U-Value: 0.23, SHGC: 0.23
Window / Wall Ratio 10.18
Window/ Floor Ratio 10.18
Infiltration 12.97 ACH50
Duct Lkg to Outside I Radiant
Total Duct Leakage I Untested
Boiler • Natural Gas • 95 AFUE
Air Source Heat Pump • Electric • 19.7 SEER2
Boiler • Natural Gas • 0.85 Energy Factor
Yes
20 CFM • 20 Watts (Default) • ERV
NIA
100%
Clothes Dryer Fuel
Electric
100%
Clothes Dryer CEF
3.9
1,071.0
Clothes Washer LER (kWh/yr)
85.0
240 kWh
Clothes Washer Capacity
3.0
None
Range/Oven Fuel
Natural Gas
Ekotrope RATER - Version 4.1.0.3403
All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report.
Building Summary
Property
55 Horseshoe Lane
Glenwood 5prin9s, CO 81623
55 Horseshoe Lane
Confirmed
■
General Building Information
N umbe r Of Bedrooms
Number Of Floors
Conditioned Floor Area [sq. ft.]
Has Electric Vehicle Ready Space
Unconditioned, attached garage?
Conditioned Volume [cu. ft.]
Total Units in Building
Residence Type
Number of Floors in Building
Floor Number
Model
Community
RESNETIIECC 2006-2018 Climate Zone
IECC2021 CIimate Zone
Organization
Inspection Status
Confl uence Architecture
2024-03-00
Mark McLain
Rater ID (RTIN):9920829
970-963-9720
RESNET Registered [Confirmed]
Builder
Arch: Axis
4
2
3,471
No
Yes
42,779
1
Single family detached
5B
5B
■
Foundation Wall
Name LibraryType
Height Above Grade
Depth Below Grade Perimeter
Location Enclosing
Basement Wall R15+RI9drape
3.7 80
0.5
Exposed Exterior Conditioned Space
CrawlspaceWall R15+R19drape
Exposed Exterior ConditionedCrawlspace
0.5
2.5 181
Foundation Wall Library List
Name Feet From Wall Top To
Feet From Wall Top To
Is Fully Insulated Continuous R-value
Cavity R-value Effective Insulation R-
Continuous Insulation
Continuous Insulation
value
Top
Bottom
R 15 + RI 9d ra pe NIA
N/A
Yes 34.00
NIA N/A
Name LibraryType
Perimeter Floor Grade
Carpet R Exposed Masonry
Area
Surface Area Location Enclosing
Basement S I a a R15 edge+ R10
8o Below Grade
0 0
369.0 ft' Exposed Exterior Conditioned Space
under
Crawlspace S I a a R15 edge +RO
191 Below Grade
0 0
1A31.0 ft' Exposed Exterior Conditioned
under
Crawlspace
1
Building Summary
Property Organization
Inspection Status
V V 11 1 1 V V Ill V V
55 Horseshoe Lane ConfluenceArchitecture
2024-03-00
Glenwood 5prings,CO 81623 Mark McLain
Rater ID (RTIN):9920829
970-963-9720
RESNET Registered [Confirmed]
55 Horseshoe Lane
Confirmed Builder
Arch: Axis
Slab Library List
Name Wall Construction Slab Completely
Underslab
Perimeter Perimeter
Perimeter Thermal Break Effective R-value
Type Insulated' Insulation Width Insulation
Depth Insulation R Value Insulation Is
/t]
/t]
Exterior
R15 edge+ RO under Wood Frarnel No
20
4 15
Yes No 0,00
Other
R1 5 edge + RI O under Wood Frame I No
20
4 15
Yes Yes 10,00
other
Framed Floor
Name LibraryType Carpet R
Floor Over Garage R38 between livin g & g a ra g e
Batt 3
Framed Floor Library List
Name Effective R•value
R38 between living & garage batt3 26,276
Rim Joist
Name
Rim
Ri rn - Garage
Rim Joist Library List
Name
R 21.0
R 27.0
ry'rype
Above Grade
Area
626,0 ft Unconditioned, attached
garage
R 27.0 204,O ft Exposed Exterior
R 21.0
Effective Insulation R-value
21.00
27.00
34,Oft Unconditioned, attached garage
2
Building Summary
Property
Organization
Inspection Status
V V 11 1 1 V
V I] V V
55 Horseshoe Lane
ConfluenceArchitecture
2024-03-00
Glenwood 5prings,CO 81623
Mark McLain
Rater ID (RTIN):9920829
970-963-9720
RESNET Registered [Confirmed]
55 Horseshoe Lane
Confirmed
Builder
Arch: Axis
Name
LibraryType
Surface Color
Surface Area
Location
Garage Wall
R21 cavity garage 3
Medium
152.0 ft
Unconditioned, attached garage
Knee Wall
RI cavity knee 3
Medium
11.0 ft,
Attic
Wall
R23 cavity +R6 Cl 3
Mediurn
3,283.0 ft'
Exposed Exterior
Wall Library List
Name
Effective R-value
RI cavity knee 3
11.185
R21 cavity garage 3
14.429
IR23 cavity + R6 Cl 3
24,802
1
Glazing
Name Library Type
Wall Foundation Wall
Is Operable
Overhang Overhang
Ft To
Overhang FtTo
Orientation
Surface Area
Assignment Assignment
Depth
Top
Bottom
East-1 .231.23
Wall
Yes
1
1
6.2
Southeast
32.0ft
East -13 .231.23
Wall
Yes
1
1.5
9
Southeast
18.0ft'
East -17 .231.23
Wall
Yes
1
7
12.8
Southeast
28.0ft
East-2 .231.23
Wall
Yes
1
17
22
Southeast
28.0ft
East-4 .231.23
Wall
Yes
1
2.0
6.8
Southeast
9.0ft
East - Entry Sidelight .231.23
Wall
Yes
9
2.5
9.5
Southeast
8.0ft
North - 11 .231.23
Wall
Yes
1
4.75
12.3
Northeast
36.0ft
North -12 .23423
Wall
Yes
1
4.75
12.3
Northeast
36.0ft
North -16 .231.23
Wall
Yes
1
1.5
6.8
Northeast
2TOft
South - IS .231.23
Wall
Yes
1
1
6.5
Southwest
28.0 ft'
South - 19 .231.23
Wall
Yes
1
6.5
12
Southwest
28.0ft'
South - 20 .231.23
Wall
Yes
1
4.8
10
Southwest
28.0 ft'
3
Building Summary
Property
Organization
Inspection Status
V
V 11 1 1 V
V 11 V V
55 Horseshoe Lane
ConfluenceArch itectuire
2024-03-00
Glenwood 5prin9s,CO 81623
Mark McLain
Rater ID (RTIN):9920829
970-963-9720
RESNET Registered [Confirmed]
55 Horseshoe Lane
Confirmed
Builder
Arch: Ax s
Name
Library Type
Wall Foundation Wall
Is Operable
Overhang Overhang Ft To
Overhang FtTo
Orientation
Surface Area
Assignment Assignment
Depth Top
Bottom
South - 3
.231.23
Wall
Yes
1 19
23
Southwest
8.0 ft
South - 5
.231.23
Wall
Yes
1 1
5
Southwest
10.0 ft
South - 6
.231.23
Wall
Yes
1 1
5
Southwest
8.0 ft
South - E
.231.23
Wall
Yes
1 2.5
9
Southwest
15.0 ft
West-10
.231.23
Wall
Yes
1 1.5
8.8
Northwest
19.Oft
West - 21
.231.23
Wall
Yes
1 4.5
10
Northwest
11.0 ft
West - 22
.23423
Wall
Yes
1 4,5
10
Northwest
28.0 ft
West-7
.231.23
Wall
Yes
1 13.5
18.3
Northwest
11.0ft
West-8
.231.23
Wall
Yes
1 1
6.5
Northwest
41.Oft
West - 9
.231.23
Wall
Yes
1 1.5
8.8
Northwest
66.0 ft
West -F
.231.23
Wall
Yes
16 6
15
Northwest
112.0ft
Glazing Library List
Name
C.23 0,230
Skylight
None Present
Skylight Library List
None Present
4
Building Summary
Property
Organization
55 Horseshoe Lane
ConfluenceArchitecture
Glenwood 5prings, CO 81623
Mark McLain
970-963-9720
55 Horseshoe Lane
Confirmed
Builder
Arch: Axis
paque Door
Name LihraryType Wall Assignment Foundation Wall
Assign ment
Entry Door 2-1/4 Woad solid Wall
core
Garage 2-1/4 Woad solid Garage Wall
Opaque Door Library List
Name Effect!
2-1/4 Wood solid core
Roof Insulation
Name LihraryType Attic ExtericrArea M Clay or Concrete Roof
Tiles
Roof - Sloped Attic vented ceiling R60 3 3,000 No
Inspection Status
2024-03-00
Rater ID (RTIN):9920829
RESNET Registered [Confirmed]
nce
Area
0.9 0.75 Medium 30.0 ftExposed Exterior
0.9 0.75 Medium 26.0ft' Unconditioned,
attached garage
Roof - deck Rafter unvented R41 flash
&R19 Batt+ RO CI 3
Roof Insulation Library List
Name
J"
Has Radiant Barrier
Attic vented ceiling R603
No
Rafter unvented 13,41 flash
No
&R19 haft + RO CI 3
Whale House Infiltration
'
Infiltration
Measurement Type
2.97 ACH at 50 Pa
Blower -door tested
2,80
Color Surface Area Location
Dark 2,460.0 ft Attic
237 No Dark 237.0 ft Vaulted Roof
58A49
32.24
Shelter Class
4
5
Building Summary
Property
Organization
55 Horseshoe Lane
ConfluenceArchitecture
Glenwood 5prin9s, CO 81623
Mark McLain
970-963-9720
55 Horseshoe Lane
Confirmed
Builder
Arch: Axis
Inspection Status
2024-03-00
Rater ID (RTIN):9920829
RESNET Registered (Confirmed)
Mechanical Ventilatio
Ventilation Type Ventilation Rate [ft'1 Operational hours Fan Watts Runs anceevery Energy Recovery
Minute] perday three hours Percent
ERV 20 CFM 24 20 Watts (Default) Yes 66
I
Manufacturer
Lighting
?� Interior Fiuorescent %Interior LED Lighting % Exterior Fluorescent ?6 Exterior LED Lighting ?6 Garage Fluorescent %Garage LED Lighting
Lighting Lighting Lighting
0 100 0 100 0 100
Onsite Generation w
None Present
Onsite Generation Library List
i
None Present
Solar Generation
Index Track Mode Nameplate Capacity (kWdd De rate Factor
Fixed 2.9 kW
2 Fixed 2.8 kW
Dehumidifier
Fixed 1.6 kW
None Present
0.83 191, AB.
0.83 191, Q.
0.77 191, 18°
Building Summary
Property
55 Horseshoe Lane
Glenwood 5prings, CO 81623
55 Horseshoe Lane
Confirmed
■
Dehumidifier Library List
Whole House Fan
Whole House Fan Library List
Conditioning Equipment
I
Name LibraryType
Cooling ASHP40.5 KBtu 5EER2
19.70 HSPF2 92
Cooling 2 ASHP40.5 KBtu SEER2
19.70 HSPF2 92
Organization
Confl uence Architecture
Mark McLain
970-963-9720
Builder
Arch: Axis
None Present
one
None Present
Number Heatina Percent
ED of III on P0
Inspection Status
2024-03-00 '
Rater ID (RTIN):9920829
RESNET Registered [Confirmed]
Percent Load Hat Water Percent
0% 50%
0% Conditioned Space
0% 50% 0% Conditioned Space
Heating Boiler 134, Rad,+water
100%
heating
Equipment Type: ASHP 40.5 KBtu SEER2 19.70 HSPF2 9.2
Equipment Type
Air Source Heat Pump
Fuel Type
Electric
Distribution Type
Forced Nr
Motor Type
ECM [Variable Speed]
Heat Pump 5ystemType
Split System
Cooling Efficiency
19.75EER2
Cooling Capacity [kBtufh]
40.5
0% 100% Conditioned Space
7
Building Summary
Property Organization
55 Horseshoe Lane CDnfl uence Architecture
Glenwood 5prin9s, CO 81623 Mark McLain
970-963-9720
55 Horseshoe Lane
Confirmed Builder
Arch: Axis
■
Equipment Type: Boiler 184,
Rad, f water heating
Equipment Type
Boiler
Fuel Type
Natural Gas
Distribution Type
Radiant
Heating Efficiency
95 AFUE
Heating Capacity EkEtufh]
184
Use default EAE
Yes
EAE [kWh]
170
Hot Water Efficiency
0.85 Energy Factor
Tank Capacity (gal.)
55
Hot Water Capacity [kBtulhl
160
Recovery Efficiency
0.95
■
Distribution System
Distribution Type
Heating Equipment
Is All Equipment In Conditioned Space
Leakage Default
Duct System Efficiency
Distribution System
Distribution Type
Cooling Equipment
Is All Equipment In Conditioned Space
Leakage Default
Duct System Efficiency
Radiant
Heating
Yes
HERS Default Leakage
1
Forced Air Ductless
Cooling
Yes
HERS Default Leakage
1
ED of III on P0
Inspection Status
2024-03-00 '
Rater ID (RTIN):9920829
RESNET Registered [Confirmed]
Distribution System
Distribution Type
Forced Air Ductless
Cooling Equipment
Cooling 2
Is All Equipment In Conditioned Space
Yes
Leakage Default
HERS Default Leakage
Duct System Efficiency
1
HVAC Grading
HVAC Grading Not Conducted
■ -
Ceiling Fan
Has Ceiling Fan No
8
Building Summary
Property
55 Horseshoe Lane
Glenwood 5prings, CO 81623
55 Horseshoe Lane
Confirmed
Water Fixture Type
Use Default Hot Water Pipe Length
Hot Water Pipe Length [ft]
At Least R3 Pipe Insulation?
Hot Water Recirculation System?
Hot Water Branch Length [ft]
Recirculation System Control
Recirculation Pump Power [Watts]
Shared?
Recirculation System Pipe Loop Length [ft]
Drain Water Heat Recovery?
■
Clothes Dryer
Cef
Fuel Type
Field Utilization
Is Outside Conditioned Space
Clothes Dryer Available
Defaults Type
rclothes Washer
Label Energy Rating
Annual Gas Cost
Electric Rate
Gas Rate
Capacity
Imef
Defaults Type
Load Type
Loads Per Week
Is Outside Conditioned Space
Clothes Washer Available
ishwasher
I
shwasher DefauItsType
shwasher Size
shwasher Efficiency
nual Gas Cost
ctric Rate
s Rate
Outside Conditioned Space
shwasherAvailable
ED of III P0
Organization Inspection Status
Confl uence Architecture 2024-03-00
Mark McLain Rater ID (RTIN):9920829
970-963-9720 RESNET Registered [Confirmed]
Builder
Arch: Axis
Low -flow
No
75
No
Yes
8
None or Timer Control
50
No
150
No
3.93
Electric
Moisture 5ensing
No
Yes
Custom
85 kWh/Year
$27.00
$0.121kWh
$1.091Therm
3
2.92
Custom
Front -load
6
No
Yes
Custom
Standard
240 kWh
$33.12
$0.121kWh
$1.091Therm
No
Yes
9
Building Summary
Property
55 Horseshoe Lane
Glenwood 5prin9s, CO 81623
55 Horseshoe Lane
Confirmed
Appliances and Controls
Programmable thermostat?
Range/Oven Fuel
Convection Oven?
Induction Range?
Range/Oven Outside Conditioned Space?
Refrigerator Consumption
Refrigerator Outside Conditioned Space?
Notes
Organization
Inspection Status
Confl uence Architecture
2024-03-00
Mark McLain
Rater ID (RTIN):9920829
970-963-9720
RESNET Registered [Confirmed]
Builder
Arch: Axis
Yes
Natural Gas
No
No
No
1,071 kWh/Year
No
Assembly
numbers correspond to numbers on SketchUp model of thermal envelope.
Goal: 2021
IECC Prescriptive & 2015 ERI 55
Original model by:
Amanda Poindexter 3774492
Rough inspection skipped.
Final inspection completed by:
Chris Taylor RFIIN #CY5MPL
Rater of record:
Mark McLain 9920829
10