HomeMy WebLinkAboutConditions of PermitCONDITION S OF PERMIT
BLRE-0 6-24-87 46
JOAOUIN BIANCO
New 1,824 SO FT Single-family dwelling w/ attached garage
897 CR 231, Silt
Willb Sub Exemption, Lot 3 - 217904100184
1 ) ALL WORK SHALL COMpLy W|TH THE 201s INTERNATTONAL RESIDENTIAL CODE (l.R.C.) AND 2018
INTERNATIONAL ENERGY CONSERVATION CODE (I.E.C.C.)
2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE
ATTACHED "GARFIELD COUNTY BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON
PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) ELECTRTCAL pERMtTTtNG AND tNSpECTIONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL
ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS
REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.
4) ALL EXTERIOR LIGHTING TO BE DOWNCAST AND SHIELDED.
5) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLYWITH WILDFIRE MITIGATION AND
DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE
DISTRICT. PLEASE REFER TO THE GARFIELD COUNTY COMMUNITY DEVELOPMENT WEBSITE FOR
ADDITIONAL I NFORMATION.
6) OPEN HOLE SOTLS REPORT tS REOUTRED AT FOOTING TNSPECTTON AND PRIOR TO ANY CONCRETE
POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE BUILDING INSPECTOR.
1,500 PSF soil bearing. (SEE ATTACHED OBSERVATION OF EXCAVATION REPORT DATED JUNE 14,
2024 PREPARED BY KUMAR & ASSOCIATES.)
7) PRE-ENGTNEERED ROOF TRUSSES. HAVE ENGINEERING FOR BUILDING INSPECTOR AT TIME OF
FRAME INSPECTION.
8) BLOWER DOOR TEST tS REOU|RED. MUST SUBMTT BLOWER DOOR TEST REPORT TO GARFIELD
COUNTY COMMUNIry DEVELOPI\4ENT DEPT. OFFICE PRIOR TO SCHEDULING FINAL BUILDING
INSPECTION / C.O. FINAL.
9) SEPTIC SYSTEM REVIEW / APPROVALS: PRIOR TO BUILDING INSPECTION & CERTIFICATE OF
OCCUPANCY PROVIDE FINAL APPROVAUSIGN.OFF FROM GARFIELD COUNry'S PUBLIC HEALTH
DEPT.
10) PRESCR|PTIVE PATH USTNG 2018 rECC TABLE R402.1.2 HAS BEEN CHOSEN FOR ENERGY
COMPLIANCE OF THIS HOME DESIGN. MANUAL J REPORT ALSO ATTACHED FOR REFERENCE.
ALL NEW HOMES TO HAVE WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM INSTALLED (2015
IRC TABLE m1507.3.3(1) AND (2) SHOWN ON COVER SHEET.
1 1) PROPOSED DWELLTNG W|TH 1,824 SO FT FTNTSHED LTVTNG SPACE AND ATTACHED GARAGE SHALL
SERVE AS THE PRIMARY DWELLING UNDER THE CURRENT BUILDING PERMIT BLRE-06-24-8746.
LAWFULLY ISSUED i INSPECTED ACCESSORY DWELLING UNITWITH 1,153 SO FT LIVING AND
GARAGE PREVIOUSLY RECEIVED A CERTIFTCATE OF OCCUPANCY ON 12l1 8/2023 UNDER PERMIT
NUMBER BLRE-02-23-7992. (NO NEW WORK SCOPE WITHTN THE ADU PROPOSED UNDER THIS
CURRENT APPLICATION.)
\
$