HomeMy WebLinkAboutCondition AttachmentsKerry Brent Scott
PO BOX 5559
Eagle, Co 81631
brent. scott@mountainbeverage. com
303-8 1 8-8667
OuntrG Le/*.r
cotlPtTl oN
Abtahnul
Cotteen Wirth
Buitding Plans Examiner
Ga rf ietd County Comm unity Devetopment
108 Bth Street, Suite 401
(970) 945-1 377 ext 1 61 0
e-wi rl-h @garf ie"[d :"eo-un ty.-aam
Dear Colleen Wirth,
Subject: Confirmation of Intended Use for Private Accessory Structure
I am writing to confirm the intended use of the accessory structure located at9023 County Road
312 New Castle, Co 81647, which is incidental to the main residence. Please be advised that this
structure is intended strictly for private use and will not be utilized for any commercial business
operations, occupancy by members of the general public, nor as aplace of future employment.
The structure will serve as an agricultural building, studio and workshop, and will be used
exclusively by the residents of the main property. We understand the importance of adhering to
zoning regulations and local ordinances, and we assure you that the use of this structure will
comply with all relevant guidelines.
Thank you for your attention to this matter.
Sincerely,
Kerry Brent Sc
Gufield Coanty
QAIDtzloN
frttracltnat
BUILDING DEPARTMENT
108 Eighth Srreet, Sune 401, Glem)ood Springs, CO 81601
Tel: (970 945-8212
Property Ownerts Certificate of Compliance
Accessory Dwelling Unit (ADU)
The undersigned property owner certifies that the attoched Building Permit Applicotion
lor Accessory Dwelling llnit (ADU) is in compliance with the following list ol stondards,
regulations ond requirements lor ADlls per Gorfield County's Lond Use & Development
Code.
1. Elqol-lllea - Maximum floor area of ADU shall not exceed 1,200 square feet.
r Measurement is from the inside of exterior walls andlor demising walls from the main
residence.
r Garages, exterior decks, patios, and stairs are not to be included.
r Laundry rooms and mechanical rooms accessed from spaces outside the ADU are not to
be included.
o Unfinished spaces are not allowed unless counted in the 1200 square foot limit.
2. Ownershio Reltriction - ADU is restricted to leasehold interest (cannot be sold or subdivided).
3. ADU oer Lot - A maximum of one ADU is allowed with a primary single-family home.
Properties with primary business structures and the Uses are allowed, a
number of ADU's explained in Section 7-7OL.A.4 of the LUDC.
4. Lepal Access - Property Owner confirms legal access to proposed ADU as illustrated on site plan.
5. Watcr- Property Owner represents that they have notified either: (a) theirwatersupplierto
address additional tap fees (if applicable) or (b) State of Colorado's Division of Water Resources
to secure any necessary water rights to supply legal water to the ADU.
6. Sewer - Property Owner represents that they have notified either: (a) their sewer & wastewater
provider to address additional tap fees (if applicable) or (b) alternately, if an on-site wastewater
treatment system (OWTS) is employed, limitations on the number of occupants using the ADU
shall not exceed maximum recommendations of existing/proposed septic system per State of
Colorado's OWTS sta ndards.
7. A deed restriction must be in place to waive Permit Fees and Transportation lmpact Fees.
*PLEASE NOIE: This form will be digitolly sconned into the Community Development Department's office records
and will be ovailable for public view ond reference in ony future title seorches for the subiect property.
I hereby acknowledge
requi
the preceding checklist and agree to abide by these
Builders West Inc.
utlDtTloN
flwachnut
Property Address:
4C Ranch Investments LLC. 9023 Ck3I2
BLRE-O5-24-8664
Colleen Please see the responses below in CAPS.
QUESTIONS / COMMENTS:
t. ls there a separate OWTS onsite wastewater treatment system ALTERATION PERMIT or
NEW SYSTEM PERMIT remitted in connection with this Ag Barn /ADU? lf so, do you
have an assigned OWTS- permit application number? The property shows a finaled
SEPT-08-22-7776 for the manufactured home installation, l'm not seeing anything
submitted since. lf you are connecting to the house septic / leach field, you'll likely
need a submit an ALTERATION PERMIT. Please advise.
HBW-WE HAVE THE ORIGINAL PERMIT CARD FOR THE MODULAR HOME SYSTEM AND A TANK
FOR THE BARN/ADU. THEy WERE TNSPECTED TOGETHER rN 2022 BEFORE MY TNVOLVMENT
WITH THIS PROJECT. I WILL ALSO SEND THAT OWTS PERMIT IN A SEPARATE EMAIL.
2. Building Application form includes checkbox by DRIVEWAY EXEMPTION. Are you
altering or revising any segment of the existing driveway system and connections out to
a public way? Please advise.
HBW-NO, THE EXISTING DRIVEWAY AND ROAD CONNECTION TO COUNTY ROADS ARE NOT
BEING EFFECTED
3. Are you planning the building structure to be fire-sprinklered? Or non-sprinklered?
HBW-NON SPRINKLER,
4. The remitted ELEVATION SHEETS do not include a scale? Can you confirm the scale on
A-4 and A-5. Rural zoned property ag building with finished living space contained
CONSTRUCTION MANAGEMENT DESIGN BUILD GENEML CONTRACTING REAL ESTATE DEVELOPMENT
281 Metcalf Road, Suite 202 / / Avon, C0 8t620 / / 970-90+-L959 / / www.hoeftbuilderswest.com
Builders West Inc.
9. Sheet A-3 enclosed room across the hallfrom the living space stairwell graphically
depicts, a lavatory sink, toilet. Washer / Dryer and unknown feature.... Which may be a
corner shower? Or perhaps a linen closet? Cannot confirm if the upper floor will have
a tub / shower stall? l'm also unclear where the door access will be to this
room? Please clarify.
HBW- UPPER LEVEL HAS A CORNER "SHOWER/DOG WASH" I HAVE NOTED ON A SEPARATE
HEATING AND INSULATION DETAILED SHEET. SEE ATTACHED.
L0. Sheet A-3 "attic" label over the barn has been crossed out. Will the agricultural barn
floor space become 'vaulted', non-habitable attic or other use or storage? Please
clarify.
HBW-VAULTED WITHOUT ANY STORAGE OR HABITABLE USE
11-. What spaces and rooms on main and upper story will become heated conditioned
space?
HBW-LOWER LEVEL TACKROOM, UPPER LEVEL ART STUDIO AND HUNTING EQUIPMENT ROOM-
SEE ATTACHED WITH HIGHLIGHTED AREAS
12. What portions of structure will remain unconditioned, unheated?
HBW- BARN SECTION WILL REMAIN UNHEATED-SEE ATTACHED AS INDICATED ON THE PLAN
13. Need to submit a MANUAL J REPORT, with Wrightsoft or other mechanical software
calculations for us to verify compliance with the 20L8 lnternational Energy Conservation
Code. Please alert your mechanical supplier, that job sites up to 7,000 ft in elevation
must meet minus 2 winter design temperature. Buildings over 7,000 ft must meet
minus l-6 winter design temperature. lt is mission critical for the report preparing to list
the correct owner name, correct site address location AND correct elevation for the site.
HBW -SEE ATTACHED
14. What is the chosen energy compliance path for the residential living portion of this
building? Are you designing in accordance to Garfield County's Climate Zone 5B using
the 2018 IECC PRESCRIPTIVE PATH and Table R4O2.L2? Or are you submitting a
separate RESCHECK REPORT? Or collaborating with a HERS rater? Please advise on the
intended energy path, so building inspectors are abreast and aware during future
inspections.
CONSTRUCTION MANAGEMENT DESIGN BUILD GENEML CONTRACTING REAL ESTATE DEVELOPMENT
281 Metcalf Road, Suite 202 / / Avon, C0 8L620 / / 970-904-L959 / / www.hoeftbuilderswest.com
M
SOUND
STRUCTURALffiffitrry
CaNDlTcU,
a#a(g,gYP'
45705 Highway 6
91o.47L.9912
Date:O6127/24
To Whom it May Concern
This letter is in regard to the new barn located at 9023 County Road 312. Sound Structural was called to
observe the built structure for conformance to the structural PERM lT drawings dated O7 /03/23.
Sound Structural performed a site visit on6/24/24 along with Patrick Hoeft of Hoeft Builders West. At
the time of the site visit, the building was erected with windows, siding, and insulation in place. The
framing was mostly visible from the interior.
FRAMING
There were three items that need to be addressed in regard to the framing.
1) At the time of the visit, grout had not yet been installed under the steel column base plates,
Grout is to be installed under baseplates similar to detail 7/56., typical'
2l The front post bases shown in detail 3/S5 were substituted for a SIMPSON ABU style post base
This substitution is acceptable. Client was informed that if excessive movement is observed due
to lateral forces, diagonal wood braces may be added at the post-beam interface at client's
discretion.
3) The roof framing members shown on the upper half of sheet 54 were called out tobe II-7/8"
TJI 360 @ 16" O.C. These rafters were installed at24" O.C.
This revision is acceptable.
FOUNDATION
The foundation was not able to be observed at the time of the visit. Patrick Hoeft provided photos from
the foundation build.
1) The photos show the reinforcing placement and quantity meet the plan requirements.
2l The width and heights of the footer and foundation wall appear to match drawing dimensions.
Assuming the corrections noted above are made, this structure conforms to the structural drawings.
Feel free to reach out with questions or concerns.
Regards,
JJ\
s
\
N
.s\
.N\s
$0
/'7
Ir.j'':
I
0
Joe O'Malley, P.E
'Tg