HomeMy WebLinkAboutSoil and Foundation Investigation 05.31.22 Revised 08.08.22j$$ Engineering Inc. CTvlUCCOTECIIHICAI, SOIL AND FOUNDATTON IT{YtrSTIGATION r.ORA MAIN RESIDENCE AI\[D BARN/AI}U 4C RAIYCH GARFTELD CREEK ROAD, CR #312 NEW CASTLE PrN 218334300058 GARFIELD COIINTY, COLORADO PROJECT NO. 22-3661 MAY 31,2022 REVISED AUGUST 8,2022 PREPARED T'OR: BRENT SCOTT P.O. BOX 5559 EAGLE, CO 81637 B rent. S cott@mountainbeveB&q. Fgn P.O. Box 724,Eagle, CO 81631 Tel. (970) 390-0307 $flvw.LKPEggipeerins.com TABLE OF CONTENTS EXECTJTTVE SU\{I\{ARY SCOPE OF STUDY SITE DESCRIPTION.. PROPOSED CONSTRUCTION ...... FIELD I}.I\{ESTIGATION SUBSURFACE SOIL AND GROUNDWATER CONDITION FOIJ}IDATION RECOMMENDATIONS . SLAB CONSTRUCTION CRAWL SPACE RETAINING WAI.LS I.JNDERDRAIN SYSTEM.. SITE GRADING AND DRAINAGE...-........... I.AWN IRRIGATION 2 2 2 3 3 3 4 5 6 6 6 ? 7 8LIMITATION AREAMAP. ......DRAWINGNO.2 FIGTJRES LOCATION SKETCH SUBSTIRFACE ffGLORATION LOGS.., GRAIN.SIZE DISTRIBUTION. . . PERIMETER DRAIN DETAIL... STRUCTURAL FILL WTTFI GEOGRID .. OVBREXCAVATION AND COMPACTTON. .. ..DITAWINGNO. 1 ....FIGURE NO's l-3 .FIGURE NO.4 .FICURE NO. 5 .FIGURE NO. 6 FI(.lIIRtr NN ? P.O. Box 724,Eagle, CO 81631 Tel (970) 390-0307 ww."'il.lkpengineerine.com E)(ECUTIVE SI'MMARY The proposed banr/residence should be supported with conventional tirye spread footings, designed for an allowable soil bearing pressure of 1500 psf. They should construct the footings on the undisturbed silty to sandy clay to silty-clayey sand with cobbles and boulders or on geogrid improved strucfiral fill. Sce Foundation Recommendations. SCOPE OF'STUDY This report presents the resuits of a subsurface Soil and Foundation Investigation for a proposed single-family residence and a barn with atr apartnent at 4C Ranch, New Castle, County Road 3 12, PIN 2 I 83 34300058, Garfield County, Colorado. The purposc of the subsurface soil and foundation investigation was to determine thc engineering characteristics of the foundation soil and to provide recommendations for the foundation design, grading, and drainage. Geologic hazard studies are otttside of our scope of sewices. SITE DESCRIPTION The 4C Ranch is 1163.959 acres property, south ofNew Castle, Garlield County, Colorado. The proposed building sites are located in tbe northwest portion of Section 3, as shown on the area map, drawing 2 and on the Location Sketch, Drawing 1. The building sites for the proposed barn/residence are on meadows. Vegetation within the proposed building site LKP Engineering, [nc, 3 consiEted of grass. The topography within the selected building areas (where the test pits were excavated) is relatively flat. Drainage is to the north and northwest. Garfield Creek and Garfield Creek Road are to the north of the proposed building site for the main residence. The area was surrounded by mountains. PROPOSED CONSTRUCTION We understand that the proposed main residence will be two story, wood frame consbuction without a basement, on a concrete foundation, and the barn building will also be two story wood frame constmction with an aparbent above on one side, and a large barn on the other. We anticipate loads to be light, typical of residential consbruction. If the finalized plans differ significantly from the above understanding, they should notify us to reevaluate the recommendations of this report. EIELD II{VESTIGATION The field investigation, conducted on May 25,2A22, consisted of logging xad sarnFling tbree test pits. Approximate locations of the test pits are shown on Drawing No. I, We show the soil profile of the test pits on the Subsurface Exploration Logs, Figurc No's I through 3. Soil samples for laboratory soil analysis and observation were taken at selected intervals. We understand that your excavator dug the test pits prior to our site visit. STIBST]RFACE SOIL AND GROTJNDWATER CONDTTION Thc soil profiles encountered in the three test pits were fairly uniform, consisting of 2 to 5 feet of topsoil over brown to light brown, silty-sandy clay to silty-clayey sand, gravelly with cobbles and varying amounts of boulders. Moisture content was high (15 to 177o) but free P.O. Box 724,Eagle,CO 81631 Tel. {970) 390-0307 www.LKPEnqineqring.cor4 4 grouud water or bedrock were not encountered in any of the test pits. We sampled the soil in the test pits at random intervals. The samples were tested for natural moisture content and grain-size disribution. The test results are shown on Figure number 4. FOTJIYDATION REC OMMENDATIONS The proposed main residence and the barn with an additional dwelling uniq should be supported witb conventional t5pe spread footings, designed for an allowable soil bearing pressure of 1500 psf. They should construct the footings on the undisturbed silty to sandy clay to silty-clayey sand, gtavelly with cobbles and some boulders- Ifunsuitable soils (thick layers of topsoil) are encountered within the foundation excavation, the proposed residence and the additional dwelling unit sbould be supported with conventional type spread footings consbucted on a structqfa!fr!1. designed for a maximum allowable soil bearing pressure of 2000 psf. TlE.fg-atings Will be nlaced on ouerscavsled 4d- compacted. strug4rql,.{ill inprovedwith thfee (3) la.vers of Tensar. Triacial Geaghl. as shown on the attached detail, Sftrcnural Fill with Geogrid, Figure No. 7. Minus 3-inch road base or other approved, imported stnrchrral material, free from topsoil, organics and volcanic ash, can be used as a structural fill. A minimum of four feet of the unsuitable subgrade materiai (topsoil or other soft or wet soils) should be overexcavated under the entire foundation. The width of the overexcavation should be according to the attached overexcavation aud compaction detail with a minimum of five feet on the outside perimeterof Ole excavation. The completedfoundatian excavation should be observed and/or tested by the undersigned engineer to verifu that the soil canditions encountered during cowttaction are as anticipated in this report. We recornmend a minimum width of 16 inches for the continuous footings and 2 feet for the isolated footing pads. Continuous foundation walls should be reinforced top and bottom to span an unsupported length ofat least I0 feet' The proposed foundation should be set at a minimum depth of four feet below the finished grade or at the minimum depth required by tlre local building code. The foundation P.O. Box 7Z4,Etgle,CO 81631 Tel. (970) 390-0307 www.LKlEngineering'Sgm 5 excavation should be free from excavation spoils, frost, organics and stasding water. We recommend proof-rolling of the foundation excavation. Soft spots detected during the proof- rolling, should be removcd by overexcavation. Any overexcavation witbin the proposed foundation should be bacldilled, in 8 inches loose level lifu and compacted to 100% ofthe maximum dry density and within 2 percent of the optimum moisfure content ss determined in a laboratory from a Standard Proctor test (ASTM n-698). A stnlchrral fill, placed nnder footings should be tested by a qualified professional. SLAB CONSTRUCTION The nahrral on-site soils, exclusive of topsoil and organics, are suitable to support lightly loaded slab-on-grade consbuction. In the event that the thick topsoil layer is also encountered under the proposed slab on grade areas, the unsuitable soil should be overexcavated and replaced with a non-swelling, structuralrtll,.fejlrbreed w,ith layers of Tensar Gegwid, as described above in the foundation recommcndations section. Tte subgrade for tbe slab-on-grade construction should be proof compacted to detect and remove soft spots. They should backfitl overexcavated soft spots and other underslab fill with the on-site soil, free from topsoil and organics, or other suitabls material compacted to a minimum of 95 percent of the maximum standardProctor density (ASTM D-698). Suitable material should be free from topsoil, organics and rock fragments greater than 3 inches. The concrete slab should be consfircted over a 4-inch layer of clean gravel consisting of -3l4-inch gravel with at least 50% retained on the No. 4 sieve and less than 3 percent passing the No.200 sieve. They should reinforce the concrete slab-on-grade and score control joints according to the American Concrete Institute requirements and per ttre recommendations of the desiguer to reduce damage due to shrinkage. The concrete slab should be separated from the foundation walls and columns with expansion joints to allow for independent movement without causing damage. P.O. Box 724,Eagle, CO 81631 Tel. (970) 390-030? www.LKPEnsineering.com 6 CRAWL SPACE If topsoil is encountered in the crawl space areas, it should be overexcavated and replaced with non-organic soil. The organic matter contained in the topsoil will decompose with time releasing odors (like row sewage) that might notbe acceptable by the homeowner. Crawl spaces should be vented according to the building code. RETAINING WALLS Foundation walls retaining earth and retaining stnrctures that are laterally supported should be designed to resist an equivalent fluid density of 60 pcf for an "at-restn condition. Lateralty unrestrained stmcturss, fetaining the on-site earth, should be designed to resist an equivalent fluid density of 40 pcf for tle "active" case. The above design recommendations assume drained baclcfill conditions and a horizontal bacldill surface. Surcharge loading due to adjacent structwes, weight of temporary stored construction materials aod equipment, inclined bacldll and hydrostatic pressure due to undrained backfill should be incorporated in the design. They should ty to prevent the buildup of hydrostatic preszure behind tbe retaining wall. Passive earth pressure of360 psfcan be used for the lateral pressure against the sides of the footings. Resistance to sliding at the bottom of the footings can be calculated based on a coefficient of frictiou of 0.5. Undisturbed soil or a stuctural fill compacted to 100 percent of the murimum dry densiff and within 2 percent of the optimum moisture content will be used to resist lateral loads at the sides of the footings. UNDERI}RAIN SYSTEM To reduce the risk of surface water infiltrating the foundation subsoil, we recommeud installation of a foundation perimeter drain (see Figure No. 5). The foundation perimeter drain should consist of a 4-inch diameter, perforated pipe, sloped to a suitable gavtty outlet, atall4 I P.O. Box 7Z4,Eagle,CO 81631 Tel. (970) 390-0307 www.LKPEneineering.com 7 inch per foot for flexible or at a 1/8 of an inch for rigid pipe. The bottom of the trench adjacent to the footing should be lined with a polyethylene moisture barrier glued to the foundation wall. The drain pipe should bo oovored with a minimum of 6 inches of -3/zt-inch frce-draining granular material. Geotextile (Mirafi l40N or equivalent) should be used to coverthe free- draining gravel to prevent siltation and clogging ofthe drain. The bacldll above the drain should be granular material to within 2 feet of the ground surface to prevent a huildup of hydrostatic pressuTe. SITE CRADING AI{D DRAINAGE The following recommendations are general. Exterior backfill should be compacted at or nEar the optimum moisture cont€nt to at least 95% of the manimum standard Proctor density under pavement, sidewalk and patio areas and to at least 90% of the maximum standard Proctor density underlandscaped areas. They should use mechanical methods of compaction. Do not puddle the foundation excavation. The site surrounding the building stnrcture should slope away from the buildiug in alt directious. A minimum of 12 inches in the first l0 feet is recommsrrded in unpaved areas, and tbree inches in the first 10 feet in paved areas. The top of the granular fouadation bacHill should be covered with a minimum of I foot of relatively impervious fi[ to reduce the potential of surface water infiltating the foundation subsoils. Surface water naturally draining toward,the proposed building site should be diverted around and away from it by rneans of drainage swales or other approved methods. The roof drains and downspouts should extend and discharge beyond the limits of the backfill. LAWN IRRIGATION It is not recommended to introduce excess water to the foundation soils by installing sprinkJer systems next to tbe building. The installation sf thc sprinkler heads should ensurc that the spray from the heads will not fall within l0 feet of foundation walls, porches or patio slabs. P.O. Box 7}4,Eagle,CO 81631 Tel. (970) 390-0307 www.LKPEngineeriqg.com I Lawn irrigation must be controlled. LIMITATION This report has been prepared according to locally accepted Professional Geotechnical Engineering standards for similar methods of testing and soil conditions at this time. The type of soil testing was selected by the owner as the prefered method for the soil and foundation investigation over a soil and foundation investigation with a drill rig. There is no otherwarcanty either expressed or implied. The findings and recommendations of this report are based on field exploration, laboratory testing of samples obtained at the specific locations shown on the Location Sketch, Drawing No.l and on assumptions stated in the report. Soil conditions at qlher-lg.catiofu m?Y. vary. rl|hich mav notbe,cgrqe evident until the fou.qd+tion,expavatio.,n iS completed. If soil or water conditiom seem different fromthose described in this reporq we should be contacted immediately to reevaluate the recommendations of this report. We are not responsible for technical interpretation by others of the data presented in this reporl This reportbas been prepared for the exclusive use ofBrent Ssott, for the specific application to the proposed Main Residence and Barn with an ADU at 4C Ranch, New Castle, County Road 312, PIN 218334300058' Garfield Coun$t, Colorado. Sincerely, LKP ENGINEERING,INC. $hw fi nt" rr?1, illr Luiza Petrovska, PE J:\_W? X4-LKP!2022U2J 606CLAY-PITS.DOC( P.O. Box ',l24,Eagle,CO 81631 Tel. (970) 390-0307 www.LKPEngineerine.com NoTE: tHE LoCATK)N oF THE TEST PnS ls APPRSX{VATE. lr 1S NOT BAS€D ON A SURVEY. LOCATION SKETCH ta aar o 6c'ar'E - 1'! g0'LKP Engineering, Inc. cIV!L,/CS66CfiN1CAL Tcl P.O. Box 7?{, Eogle, C€ 81631 5SO-0307 4C RANCH CR 312, NEW CASTLE PIN: 216 334 3{nO 58 GARFIEI.D COUNTY, COLORAOO Coanty fi.d' a/ I t t i 1 6!,,_d!attt' T65 -i R90W .' ,; i'* 1 I I t ,, I I lffi*1.' ; 1. { B{I,D 'lt(JlJNIArIl' , '.:)..',t"',' ,','Y T5F 889W ,i, +'t 'rEc R9OW I It ' r ;l t {t ,j )t ,1 rr ,i.r 'I !lr}Js I 1 I , T65 R9rW .crq'q ^);' l {I I I .i tl f--' allI u.s. R!91,r I ,1, , ..^.t , o"u -:- t.t, I l, ;1, l:@ls-g*r-r )';: T85 R91W T8S R90W T8S R89W { t-E:-G 01lfl| NOTE THE LOCATKIN OF THE TEST FrI6 ls APPROXIMATE. lT IS NOT SASED ON A SUR\€Y, AREA MAP 22-3619 - 1'= 80' 2 4C RANCH cR 3ra NEvv CASTLE PIN:218 334 3000 58 GARFIELg COUNTY. COLORADO LKP Engineering, Inc. clvlL/CE(rTECSMCAL Tel P.O, Sox 724, Eogla, CO gt63t 390-0307 GsrJiuld Counly Colctcdo Lond Explorer - OATE OBSER\ED; Moy 25,2022 ETTVATION: Test Pit-l/Protile Eole-l Maln Eouse DEPIH FEFT s Y *l B o L s A M P L E DESCRIPTIOII tr NATrr('AL AT,ID SATIPIE LOCANOiI I.ABRAIORY TESr fESUtTs REIIARKS 5 t0 -tt m d Topsail, thic*ness varies from 2 to 5 feet &rown, clasnygrovelly sond wlth cobbles and bouldars fikt5-lr Light brown, sqndy clay motrix with cobbles ond boulderc -zgaaJa.6x Eottom of Test Plt @ 7.5 feet No Ground Woter Encountered I,EGEND: tr: DI) HC -2ACu PI cw * 2-frrctt O.D. Calltomla Unar Sampls - Bulk Somplc - Natuml Dry Dawlty (pcf) - Noturzl lloleturc Contqnt (t) - Percant Passlng Na, Zoa S/cw - Llquld Umlt- Plogtlcity ladex - Oround tater IfiP ENCINEERINC, INC.SI'BSUNFACE H(PIORATION IOG t'lrrcgf tg..22-J6rs IfiEmi DAIE OBSER\ED: ilsy 25,20,22 ELEIJAIION; Test Plt-? Tf;g.in frolnee DEPTH FEET .: YuI o L s A u P L E DE5CRf,NON OF UATERIAL AND SA'IPLE LOCANU,I I.ABORArcRY TESTRTSULI5 RE IARKS : t_ t_ t_ t- l- 5 t0 tg m A EpEoif-fnichness varies from 2 to 4 feet Light brown, sllty'sandy claY motrix with cobbles and large boulders Eottom of Test Plt @ 6.5 feet Na Ground Woter Encountered I,,EGEND: tra DD HC -200u PI etv * 2-lnch OO. Callfomla Llnar Somple - Bulk Samplo - Notwal Dry Doasky (pcf) - Natural Molstura Contcnt (X) - Parcut Paselng No. 200 Slcve - Uquld Umlt - Plostlclty lndcx - Oround vator I,ffP SNGINEERINC, INC.STIBSIIFFACE EXPLORATION I,OG I;AGE rni 22-3619 tnEm..2 DAIE OBSER\IEDI Moy 25, ?:022 EI.EVAIION: Test Pit-9 Barn-AJ/A DPfHffir 5r nI o L s A u P L E Df5tt?lPno{ oF IIATERIAL AND SA'IPIE L(NAWN L/Eof,A?aRY tEsr REst lTs Rgrmrs 5 -10 -16 -n I fopsoil, thlckness variee from 2to 4 feet Llght brawn, matrix with boulders slltSrsandy clay cobbles and large Eottom of Test Pit @ 7 feat No Ground Woter Encauntered I,EGEM: tr - 2-lnch OD. Collfonlo L[nar SamplaI - Eulk SamplcDD - Natural Dry Danslty (pcf)HC - Natunl Molgtura Contmt (t) -200 - Pxaant Passlng Na. 2OA SbwU - UEtld lJntltPl - Plostlclty lndcxGW - Ground natcr I.XP DNEINEERING, INC.SUSSUNFACE EXPIORAfiON LOG fllqagTE 22-J6r9 FTSETil.:J $ =Ia N U U, x Ue{g t t $ B $I s f) FRdl: Tsst PIt I ot 5 fitt tts. glAtOAtu sEr€ frtrf{o N I{crE, E 1 3 21a I s lls gt{tAlUD SEI€ AflfinS t a 6 tlo 14'/, m &an7otQr&m Hrga(retg| rr*0 90 w 70 b $aooT $-o €lo * S .ro 20 to ,o 2A JO !*il soP aq 60 .s\ F709 o EO 90 too 5A)t00 50 ,o5 I 0,5 0.t 0,06 '.005 0,00t Sand: 35.6I Flnrc: 35.6t \ \ I \- t \ Sllt or Clay Sand fupmedlhmco(mtt govC llnocoortC&Hae Holsturp ContmF l51I @vvC: 2&7X Dcscdptlort: Envn, sf,tydapy gravclly amd 3dtd oelu uoj tlnnlNln HSNrstr oNV:t1s1x3-u uoJ 100J utd l{cNt*,l w No[voNnoJ 3Hl WOUJ AVMV NOtw3o] lHgllAVO V -NVM NO|IVqNNOJ or o3dols Sdld oSlwoluad u3J,lnvl6 or c3n'19'u3Nn 3ltsv"td 'ss3Nv3Hl nnwtNll^l'lll\t 08 ytou Hsnuc hn€]o 'aswog'uat-anvtc HcNtt E Urlg]v^lnosuo Nort uwtnlctuwr llos snonu3dlll A'I3Nl\n3U JO 1001 3NO JO nnWlNl$l V Hl,fvl ]'llJXgvs avTnNVa977A r{ I -' t :' eyuopt sr\r\ { <l4t a .rl fa .<t 't B, B''\, E ''. .4. , {J 9MOTnE v'lQul AVMV toco-06g pt tcgrg 03 'eFo3 't?e roE 'O'd 'aul 'FtrttaaEfiSu[ rvctNHtilogc,/TtJtla dlIT NIWQ ATT,IgfiIA&d ogwolo3'atNno9 (r-r3rJUVg 89 0008 'ee gtz:Ntd t-ttsvc MlN'ztg H9 H3NVH 3'6t9g-zz ,aN 13?r1J}') 'sIN mws I :M M'J I rToSrDtrIH COTIPACTMnuFOOTTNC I 2 FAR QWTNuets Fo4frNg d = oEPfH To AOEO|IATE BEARilNO ttAfZRlALd-2xb ,ltltcHEWR /S lf,S',S SOUARE EOONNE d - DEP\H 7V ADEWAIE EEARINO MATERIALd:l-l/2xb '+HIaHEWR 1s trSS' NOTE: Source af informdtion from Faundaffons and Earth Strueturea 0esfgn Monuol Z2 Dcpartment of the Nauy, Nowl Facllitles Engineering Commond LKP gvrt /cBo[EcE{tc& Engineering, lnc. P.O. Box 724, TGa (97o) 3sq-os07 co 81531 OVEREXCAVATION & RECOMPACTION 4C RAT{CH CR312, NEWCASTLE PIN:218 334 3UX) 58 GARFIELD COUNTY. COLORADO mi6cra[: ?2-3619 stE /vrs FEtr,U: 6 FOOTING I I I.,tb. : lYr' j., o-l!o Foo tr lrJooo C)oJ 5'mln 6'max. 6'mln, SOFT (or Unsullabte) BEARTNG TENSAR TRIN(IAL GEOGRID MINUS 3.'NCH ROAD FOR S'TRUCTUML FILL PLACEMENT OVEREXCAVATE4 FEET BELOWTHE FOONNGS AND- 3 FEET BELOW THE SI.AB ON GRADE CEOGRM REINFONCED STEACTARAT FILL 22-3619 N.T.S. cw&/aBorttscEYrerl Engineering, fnc.LKP ? Tol {s70) 4C RANCH CR312. NEWCASTLE PIN:218 3A4 3000 Sg GARFIELD COUNTY, COLORADO 7