Loading...
HomeMy WebLinkAboutResCheck CertificateGenerated by RESche ck-Web Software Compliance Ceftificate Project 9023 County RD 312_REScheck-O6I924 Energy Code: Location: Construction Type: Project Type: Orientation: Conditioned Floor Area Glazing Area Climate Zone: Permit Date: Permit Number: All Electric ls Renewable Has Charger Has Battery: Has Heat Pump: 2018 IECC Garfield County, Colorado Single-family New Construction Bldg. faces O deg. from North 1,488 ft2 LOo/o 5 (8499 HDD) false false false false false Construction Site: 9023 County RD 312 Newcastle, CO 81647 Envelope Assemblies Ceiling: Flat Ceiling or Scissor Truss Wall, Paftition: Wood Frame, 16" o.c. Orientation: Back Wall, Front: Wood Frame, 16" o.c. Orientation: Front Door, Entry SGD: Glass Door (over 5oo/o glazing) Orientation: Front Door, Upper SGD: Glass Door (over 50% glazing) Orientation: Front Windows: Vinyl Frame Orientation: Front 864 580 580 56 67 60 0.026 0.060 0.060 0.300 0.300 0.300 22 35 24 t7 20 18 Owner/Agent: Patrick Hoeft Hoeft Builders West lnc 970-904-1959 patrick@hoeftbuilderswest.com Designer/Contractor: Compliance: 6,170 BetterThan Code Maximum UA: 214 Your UA: 2ol The o/o Better or Worse Than Code lndex reflects how close to compliance the house is based on code trade-off rules' It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck, Each slab-on-grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements, 49.0 27.O 27.O 0.0 0.0 0.0 0.026 0.051 0.051 0.270 0.270 0.270 22 30 20 15 18 16 Compliance: Passes using UA trade-off Gross Area or Perimeter Cavity R-Value Cont. R-Value Prop. Req. U-Factor U-Factor Req' UAAssemblyProp UA Project Title: 9023 County RD 3L2-REScheck-061924 Data filename; Report date: 061L9124 Page 1- of1"0 Gross Area or Pet ilrreter Cavity R-Value Cont. R-Value Prop. Req, U-Factor U-Factor Prop UAAssembly Req, UA Wall, Left: Wood Frame, 16" o.c. Orientation: Left side Door, OH: Solid Door (under 50% glazing) Orientation: Left side Wall, Right: Wood Frame, 16" o.c. Orientation: Right side Door, OH: Solid Door (under 50% glazing) Orientation: Right side Wall, Left knee wall: Wood Frame, 16" o.c. Orientation: Left side Wall, Right Knee Wall: Wood Frame, 16" o.c. Orientation: Right side Floor, Slab on Grade: Slab-On-Grade (Unheated) lnsulation depth: 2.0' lnsulation position: Fully lnsulated (uniform R-value across perimeter and under slab) 240 72 240 72 120 120 120 0.060 0.300 0.060 0.300 0.060 0.060 0.360 27.O 0.0 27.O 0.0 27.O 27.O 0.0 0.0 10.0 0.051 0.350 0.051 0.350 0.051 0.051 0.360 9 25 9 25 10 22 10 22 6 Compliance StatemenL The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2018 IECC requirements in REScheckVersion : REScheck-Web and to comply with the mandatory requirements listed in the REScheck lnspection Checklist. Mark Scott, Scott Home Services, LLC Vl/arr6 Sut June 19,2024 Name - Title Signature Date 7 7 0 6 0 Project Title: 9023 County RD 312_REscheck_061924 Data filename: Report date: 06119124 Page 2 ofL0 REScheck Software Version : REScheck-Web lnspection Checklist Energy Code: 2OLS IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen, For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Additional Comments/Assumptions: Section # & Req.lD Pre-lnspection/Plan Review Plans Verified Value Field Verified Value Complies?Comments/Assumptions 103.1, 103.2 lPR1ll e Construction drawings and documentation demonstrate energy code compliance for the building envelope. Thermal envelope represented on construction documents. nComplies nDoes Not !Not Observable ENot Applicable 1 03.1, 103.2, 403.7 lPR3l1 .9, Construction drawings and documentation demonstrate energy code compliance for lighting and mechanical systems. Systems servin g multiple dwelling units must demonstrate compliance with the IECC Commercial Provisions. !Complies nDoes Not nNot Observable nNot Applicable 302.1, 403.7 lPR2l2s Heating and cooling equipment is sized per ACCA Manual S based on loads calculated per ACCA Manual J or other methods approved by the code official. Heating: Btu/hr_ Cooling: Btu/hr Heating: Btuihr_ Cooling: Btu/hr !Complies !Does Not nNot Observable nNot Applicable I (Tier 1)Hi hlm 2 Medium lmpact (Tier 2)3 Low lmpact (Tier 3) Project Title: 9023 County RD 312_REScheck_O61924 Data filename: Repoft date: 06119124 Page 3 ofL0 Comments/Assumptions Section # & R€q.lD Foundatlon lnspection Flanr Verlfied Value Field Verlfled Value Complles? 402.L.2 lFoll1 @ R-_ I Unheated ! Heated tlComplies inDoes trtot inNot observable lnNot Applicable Slab edge insulation R-value R-See the Envelope Assemblies table for values.! Unheated ! Heated 402.1,.2 lFo3ll ,& ncomplies EDoes Not nNot Observable nNot Applicable ft ft See the Envelope Assemb/ies .table for values. Slab edge insulation depth/length. 303,2.1 lFOLLl2 s A protective covering is installed to protect exposed exterior insulation and extends a minimum of 6 in. below grade, ncomplies nDoes Not nNot Observable flNot Applicable 403,9 IFO1212 g Snow- and ice-melting system controls installed. nComplies nDoes Not !Not Observable nNot Applicable Additional Comments/Assumptions: 1 Hi hlm act (Tier 1)2 Medium lm (Tier 2)3 Low lmpact (Tier 3) Project Title: 9023 County RD 31.2_REScheck_061924 Data filename: Report date: O6lL9l24 Page 4 ofL0 Complies?Comments/AssumptionsFraming / Rough-ln Inspection Plans Verified Value Field Verified Value Section # & Req.lD 402.L.L, 402.3.4 lFR1l1 .9/ nComplies !Does Not nNot Observable llNot Applicable See the Envelope AssembliesDoor U-factor table for values. U-U- 402.r.r, 402.3.r, 402.3,3, 402.5 lFR2l1 ,'sr nComplies nDoes Not nNot Observable nNot Applicable U-U-See the Envelope Assemblies table for values. Glazing U-factor (area-weighted average). 303.1.3 lFR4l1 'S,' U-factors of fenestration products : are determined in accordance with the NFRC test procedure or taken from the default table. !Complies lDoes Not nNot Observable nNot npplicable 402.4.r.L lFR23lr u Air barrier and thermal barrier installed per manufacturer's i nstructions. nComplies nDoes Not !Not Observable nruot nppl icable 402.4.3 lFR20l1 .w, Fenestration that is not site built is listed and labeled as meeting AAMA /WDMA/CSA 1 O 1/I,S, 2/A440 or has infiltration rates per NFRC 400 that do not exceed code limits, EDoes Not !Not Observable nNot Applicable plies lC-rated recessed lighting fixtures sealed at housing/interior finish and labeled to indicate <2.0 cfm : leakage at 75 Pa. [JComplies nDoes Not nNot Observable !Not Applicable 402.4.5 lFR1,6l2 Supply and return ducts in attics ' insulated >= R-8 where duct is >= 3 inches in diameter and >: R-6 where < 3 inches. Supply and return ducts in other portions of the building insulated >: R-6 for , diameter >= 3 inches and R-4.2 Ducts, air handlers and filter boxes are sealed with joints/seams compliant with lnternational Mechanical Code or lnternational Residential Code, as a pplicable. for < 3 inches in diameter 403.3.1 lFR12l1 9r !Complies nDoes Not nNot Observable !Not Applicable 403.3.2 lFR13l1 Sr nComplies !Does Not nNot observable !Not Applicable 403.3.5 lFR1513 'gr !Complies nDoes Not nNot Observable !Not Applicable Building cavities are not used as ducts or plenums. R-R- cablenruot mplies 403,4 lFR17l2 ,g HVAC piping conveying fluids above 105 sF or chilled fluids below 55 sF are insulated to >R- 2 Protection of insulation on HVAC piping. 403.4.1 lFR24l1 'vj nComplies nDoes Not !Not Observable lDoes Not !Not Observable nNot Applicable 403,5.3 lFRl8l' .9 nComplies nDoes Not nNot Observable nNot Applicable R-R.Hot water pipes are insulated to >R-3. 3 Low lm (Tier 3)1 High lmpact (Tier 1)2 Medium I (Tier 2) Project Title: 9023 County RD 312_REscheck_061924 Data filename: Report date: 06119l24 Page 5 of1"0 intakes and exhausts. are Additional Comments/Assu m ptions : 1 (Tier 1)(Tier 2)lm Low I (Tier 3) Project Title: 9023 County RD 3lz_REscheck_o61.924 Data filename: Report dater 06lLgl24 Page 6 of10 303.1 lrN13l,s All installed insulation is labeled or the installed R-values provided, nComplies lDoes Not nNot Observable !Not Applicable 402.1,.L, 402.2.5, 402.2.6 ltN3lls Wall insulation R-value. lf this is a mass wall with at least % of the wall insulation on the wall exterior, the exterior insulation requirement applies (FR10). R-_ I I Wood I Mass ! Steel !Complies nDoes Not nNot Observable I nNot Applicable l! Steel See the Envelope Assemblies table for values. I R-_ 1l I Wood ifl Mass !complies nDoes Not !Not Observable nNot Applicable 303.2 ltN4l1 Wall insulation is installed per manufacturer's instructions. Additional Comments/Assumptions: 3 Low lm ct (Tier 3)1 h lmpact (Tier 1)2 Medium (Tier 2) Project Title: 9023 County RD 312_REscheck_061924 Data filename: Report date: 06119124 Page 7 of10 Section I# | final lnspection Provisions & Rco.lD I Plans,Verlfled Value. Field Verlfled Value eomplieo?Common E/Assurnptlons 402.1.1, CeilinginsulationR-value. 402.2.1, 402.2.2, 402.2.6 lFt 111 incomplies nDoes Not inruot observable iENot Applicable R-_ I Wood n Steel See the Envelope Assemb/ies table for values. iR- :ll Wood I ! Steel 303,1.1.1, Ceiling insulation installed per303.2 imanufacturer'sinstructions. [Fl2]r :Blown insulation marked every 300 fr,. EComplies lDoes Not nNot Observable !Not Applicable Vented attics with air permeable insulation include baffle adjacent to soffit and eave vents that extends over insulation. 402.2.3 tFt2212 ncomplies nDoes Not nNot Observable flNot Applicable Attic access hatch and door insulation >R-value of the adjacent assembly. tnComplies tnDoes Not lnNot observable rlNot Applicable R-R-402.2.4 lFt3ll Blower door test @ 50 Pa. <=5 ach in Climate Zones 1-2, and <=3 ach in Climate Zones 3-8. incomplies t!Does trtot :flNot Observable 1[JNot Applicable ACH 50 =ACH 50 =402.4.1.2 lFt 17 11 Ducts are pressure tested to determine air leakage with either: Rough-in test: Total leakage measured with a pressure differential of 0.1 inch w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test: Total leakage measured with a :pressure differential of 0.1 inch w.g. across the entire system , including the manutacturer's air handler enclosure. cfm/100 cfm/100 ft2 ft2 403.3.3 lFt27l1 tlcomplies nDoes Not ENot Observable rnNot Applicable Duct tightness test result of <=4 cfm/100 ft2 across the system or <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in 'tests, verification may need to occur during Framing lnspection. cfm/100 ft2 ft2 IDoes Not 403.3,4 lFt4lr tnNot Observable lnNot Applicable cfm/100 t[JComplies Air handler leakage designated by manufacturer at <=2Yo of design air flow. nComplies nDoes Not nNot Observable flNot Applicable 403.3.2.1 lFt24l1 Programmable thermostats installed for control of primary heating and cooling systems and initially set by manufacturer to code cations. 403.1.1 lFtel2 Ecomplies nDoes Not !Not Observable []Not Applicable Heat pump thermostat installed on heat pumps. 403,1,2 lFt1012 EComplies nDoes Not flNot Observable nNot Applicable Circulating service hot water systems have automatic or accessible manual controls, 403.5.1 lFt1112 nComplies lDoes Not INot Observable nNot Applicable 1 lm ct (Tier 1)H 2 3 Low I (Tier 3)Medium (Tier 2) Project Title: 9023 County RD 3l-2_REscheck_061924 Data filename: Report date: OGIL9/24 Page 8 of10 Section # & Req,lD Final Inspection Provisions Plans Verified Value Field Verified Value Complies?Comments/Assumptions 403.6.1 lFt25l2 All mechanical ventilation system fans not part of tested and listed HVAC equipment meet efficacy and air flow limits per Table R403.6.1. nComplies EDoes Not !Not Observable nNot Applicable 403.2 lFt2612 Hot water boilers supplying heat through one- or two-pipe heating systems have outdoor setback control to lower boiler water temperature based on outdoor tem perature. nComplies nDoes Not nNot Observable ENot Applicable 403.5.1.1 lFl28l2 Heated water circulation systems have a circulation pump. The system return pipe is a dedicated return pipe or a cold water supply pipe. Gravity and thermos- syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. !Complies nDoes Not ENot Observable nruot Applicable 403.5.r.2 I Ft29]2 Electric heat trace systems comply with IEEE 515.1 or UL 515. Controls automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping. lComplies nDoes Not nNot Observable lNot Applicable 403.5.2 lFt3ol2 Demand recirculation water systems have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to <= 1044F. lComplies EDoes Not !Not Observable nNot Applicable 403.5.4 Drain water heat recovery units tested in accordance with CSA 855.1. Potable water-side pressure loss of drain water heat recovery units < 3 psi for individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. nComplies EDoes Not nNot Observable nNot Applicable I F r31], 404.t lFt6li 90Yo or more of permanent fixtures have high efficacy lamps. nComplies nDoes Not !Not Observable ENot Applicable 404.r.1 I Ft23]3 '? Fuel gas lighting systems have no continuous pilot light. nComplies nDoes Not nNot Observable nNot Applicable 401.3 [Ft712 Compliance certificate posted lComplies EDoes Not ENot Observable nNot Applicable 3 (Tier 3)Low1lmpact (Tier 1)H 2 Medium (Tier 2) Project Title: 9023 County RD 312_REScheck_061924 Data filename: Report date: 06119124 Page 9 of10 Manufacturer manuals for mechanical and water heating systems have been provided, Additional Com ments/Acsu m ptionsr 1 Low Project Title: 9023 County RD 312_REscheck-06L924 Data filename; Report date: A-AILgl?4 Page 1.0 of1.0 fr 2018 IECC Energy Efficiency Certificate Above-Grade Wall Below-Grade Wall Floor Ceiling / Roof Ductwork (unconditioned spaces): Window Door Heating System Cooling System Water Heate Name: Comments 27.OO o.oo 10.o0 49.OO o.27 o.35 Date: lnsulation Rating R-Value Glass & Door Rating U-Factor SHGC Heating & Cooling Equipment Efficiency