HomeMy WebLinkAboutResCheck CertificateGenerated by RESche ck-Web Software
Compliance Ceftificate
Project 9023 County RD 312_REScheck-O6I924
Energy Code:
Location:
Construction Type:
Project Type:
Orientation:
Conditioned Floor Area
Glazing Area
Climate Zone:
Permit Date:
Permit Number:
All Electric
ls Renewable
Has Charger
Has Battery:
Has Heat Pump:
2018 IECC
Garfield County, Colorado
Single-family
New Construction
Bldg. faces O deg. from North
1,488 ft2
LOo/o
5 (8499 HDD)
false
false
false
false
false
Construction Site:
9023 County RD 312
Newcastle, CO 81647
Envelope Assemblies
Ceiling: Flat Ceiling or Scissor Truss
Wall, Paftition: Wood Frame, 16" o.c.
Orientation: Back
Wall, Front: Wood Frame, 16" o.c.
Orientation: Front
Door, Entry SGD: Glass Door (over 5oo/o glazing)
Orientation: Front
Door, Upper SGD: Glass Door (over 50% glazing)
Orientation: Front
Windows: Vinyl Frame
Orientation: Front
864
580
580
56
67
60
0.026
0.060
0.060
0.300
0.300
0.300
22
35
24
t7
20
18
Owner/Agent:
Patrick Hoeft
Hoeft Builders West lnc
970-904-1959
patrick@hoeftbuilderswest.com
Designer/Contractor:
Compliance: 6,170 BetterThan Code Maximum UA: 214 Your UA: 2ol
The o/o Better or Worse Than Code lndex reflects how close to compliance the house is based on code trade-off rules'
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck, Each slab-on-grade
assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements,
49.0
27.O
27.O
0.0
0.0
0.0
0.026
0.051
0.051
0.270
0.270
0.270
22
30
20
15
18
16
Compliance: Passes using UA trade-off
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-Value
Prop. Req.
U-Factor U-Factor
Req'
UAAssemblyProp
UA
Project Title: 9023 County RD 3L2-REScheck-061924
Data filename;
Report date: 061L9124
Page 1- of1"0
Gross Area
or
Pet ilrreter
Cavity
R-Value
Cont.
R-Value
Prop. Req,
U-Factor U-Factor
Prop
UAAssembly Req,
UA
Wall, Left: Wood Frame, 16" o.c.
Orientation: Left side
Door, OH: Solid Door (under 50% glazing)
Orientation: Left side
Wall, Right: Wood Frame, 16" o.c.
Orientation: Right side
Door, OH: Solid Door (under 50% glazing)
Orientation: Right side
Wall, Left knee wall: Wood Frame, 16" o.c.
Orientation: Left side
Wall, Right Knee Wall: Wood Frame, 16" o.c.
Orientation: Right side
Floor, Slab on Grade: Slab-On-Grade (Unheated)
lnsulation depth: 2.0'
lnsulation position: Fully lnsulated (uniform R-value
across perimeter and under slab)
240
72
240
72
120
120
120
0.060
0.300
0.060
0.300
0.060
0.060
0.360
27.O 0.0
27.O 0.0
27.O
27.O
0.0
0.0
10.0
0.051
0.350
0.051
0.350
0.051
0.051
0.360
9
25
9
25
10
22
10
22
6
Compliance StatemenL The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2018 IECC requirements in
REScheckVersion : REScheck-Web and to comply with the mandatory requirements listed in the REScheck lnspection Checklist.
Mark Scott, Scott Home Services, LLC Vl/arr6 Sut June 19,2024
Name - Title Signature Date
7
7
0
6
0
Project Title: 9023 County RD 312_REscheck_061924
Data filename:
Report date: 06119124
Page 2 ofL0
REScheck Software Version : REScheck-Web
lnspection Checklist
Energy Code: 2OLS IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen, For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Additional Comments/Assumptions:
Section
#
& Req.lD
Pre-lnspection/Plan Review Plans Verified
Value
Field Verified
Value Complies?Comments/Assumptions
103.1,
103.2
lPR1ll
e
Construction drawings and
documentation demonstrate
energy code compliance for the
building envelope. Thermal
envelope represented on
construction documents.
nComplies
nDoes Not
!Not Observable
ENot Applicable
1 03.1,
103.2,
403.7
lPR3l1
.9,
Construction drawings and
documentation demonstrate
energy code compliance for
lighting and mechanical systems.
Systems servin g multiple
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
!Complies
nDoes Not
nNot Observable
nNot Applicable
302.1,
403.7
lPR2l2s
Heating and cooling equipment is
sized per ACCA Manual S based
on loads calculated per ACCA
Manual J or other methods
approved by the code official.
Heating:
Btu/hr_
Cooling:
Btu/hr
Heating:
Btuihr_
Cooling:
Btu/hr
!Complies
!Does Not
nNot Observable
nNot Applicable
I (Tier 1)Hi hlm 2 Medium lmpact (Tier 2)3 Low lmpact (Tier 3)
Project Title: 9023 County RD 312_REScheck_O61924
Data filename:
Repoft date: 06119124
Page 3 ofL0
Comments/Assumptions
Section
#
& R€q.lD
Foundatlon lnspection Flanr Verlfied
Value
Field Verlfled
Value Complles?
402.L.2
lFoll1
@
R-_
I Unheated
! Heated
tlComplies
inDoes trtot
inNot observable
lnNot Applicable
Slab edge insulation R-value R-See the Envelope Assemblies
table for values.! Unheated
! Heated
402.1,.2
lFo3ll
,&
ncomplies
EDoes Not
nNot Observable
nNot Applicable
ft ft See the Envelope Assemb/ies
.table for values.
Slab edge insulation
depth/length.
303,2.1
lFOLLl2
s
A protective covering is installed
to protect exposed exterior
insulation and extends a
minimum of 6 in. below grade,
ncomplies
nDoes Not
nNot Observable
flNot Applicable
403,9
IFO1212
g
Snow- and ice-melting system
controls installed.
nComplies
nDoes Not
!Not Observable
nNot Applicable
Additional Comments/Assumptions:
1 Hi hlm act (Tier 1)2 Medium lm (Tier 2)3 Low lmpact (Tier 3)
Project Title: 9023 County RD 31.2_REScheck_061924
Data filename:
Report date: O6lL9l24
Page 4 ofL0
Complies?Comments/AssumptionsFraming / Rough-ln Inspection Plans Verified
Value
Field Verified
Value
Section
#
& Req.lD
402.L.L,
402.3.4
lFR1l1
.9/
nComplies
!Does Not
nNot Observable
llNot Applicable
See the Envelope AssembliesDoor U-factor
table for values.
U-U-
402.r.r,
402.3.r,
402.3,3,
402.5
lFR2l1
,'sr
nComplies
nDoes Not
nNot Observable
nNot Applicable
U-U-See the Envelope Assemblies
table for values.
Glazing U-factor (area-weighted
average).
303.1.3
lFR4l1
'S,'
U-factors of fenestration products :
are determined in accordance
with the NFRC test procedure or
taken from the default table.
!Complies
lDoes Not
nNot Observable
nNot npplicable
402.4.r.L
lFR23lr
u
Air barrier and thermal barrier
installed per manufacturer's
i nstructions.
nComplies
nDoes Not
!Not Observable
nruot nppl icable
402.4.3
lFR20l1
.w,
Fenestration that is not site built
is listed and labeled as meeting
AAMA /WDMA/CSA 1 O 1/I,S, 2/A440
or has infiltration rates per NFRC
400 that do not exceed code
limits,
EDoes Not
!Not Observable
nNot Applicable
plies
lC-rated recessed lighting fixtures
sealed at housing/interior finish
and labeled to indicate <2.0 cfm :
leakage at 75 Pa.
[JComplies
nDoes Not
nNot Observable
!Not Applicable
402.4.5
lFR1,6l2
Supply and return ducts in attics '
insulated >= R-8 where duct is
>= 3 inches in diameter and >:
R-6 where < 3 inches. Supply and
return ducts in other portions of
the building insulated >: R-6 for ,
diameter >= 3 inches and R-4.2
Ducts, air handlers and filter
boxes are sealed with
joints/seams compliant with
lnternational Mechanical Code or
lnternational Residential Code, as
a pplicable.
for < 3 inches in diameter
403.3.1
lFR12l1
9r
!Complies
nDoes Not
nNot Observable
!Not Applicable
403.3.2
lFR13l1
Sr
nComplies
!Does Not
nNot observable
!Not Applicable
403.3.5
lFR1513
'gr
!Complies
nDoes Not
nNot Observable
!Not Applicable
Building cavities are not used as
ducts or plenums.
R-R-
cablenruot
mplies
403,4
lFR17l2
,g
HVAC piping conveying fluids
above 105 sF or chilled fluids
below 55 sF are insulated to >R-
2
Protection of insulation on HVAC
piping.
403.4.1
lFR24l1
'vj
nComplies
nDoes Not
!Not Observable
lDoes Not
!Not Observable
nNot Applicable
403,5.3
lFRl8l'
.9
nComplies
nDoes Not
nNot Observable
nNot Applicable
R-R.Hot water pipes are insulated to
>R-3.
3 Low lm (Tier 3)1 High lmpact (Tier 1)2 Medium I (Tier 2)
Project Title: 9023 County RD 312_REscheck_061924
Data filename:
Report date: 06119l24
Page 5 of1"0
intakes and exhausts.
are
Additional Comments/Assu m ptions :
1 (Tier 1)(Tier 2)lm Low I (Tier 3)
Project Title: 9023 County RD 3lz_REscheck_o61.924
Data filename:
Report dater 06lLgl24
Page 6 of10
303.1
lrN13l,s
All installed insulation is labeled
or the installed R-values
provided,
nComplies
lDoes Not
nNot Observable
!Not Applicable
402.1,.L,
402.2.5,
402.2.6
ltN3lls
Wall insulation R-value. lf this is a
mass wall with at least % of the
wall insulation on the wall
exterior, the exterior insulation
requirement applies (FR10).
R-_
I I Wood
I Mass
! Steel
!Complies
nDoes Not
nNot Observable I
nNot Applicable l! Steel
See the Envelope Assemblies
table for values.
I R-_
1l I Wood
ifl Mass
!complies
nDoes Not
!Not Observable
nNot Applicable
303.2
ltN4l1
Wall insulation is installed per
manufacturer's instructions.
Additional Comments/Assumptions:
3 Low lm ct (Tier 3)1 h lmpact (Tier 1)2 Medium (Tier 2)
Project Title: 9023 County RD 312_REscheck_061924
Data filename:
Report date: 06119124
Page 7 of10
Section I# | final lnspection Provisions
& Rco.lD I
Plans,Verlfled
Value.
Field Verlfled
Value eomplieo?Common E/Assurnptlons
402.1.1, CeilinginsulationR-value.
402.2.1,
402.2.2,
402.2.6
lFt 111
incomplies
nDoes Not
inruot observable
iENot Applicable
R-_
I Wood
n Steel
See the Envelope Assemb/ies
table for values.
iR-
:ll Wood
I ! Steel
303,1.1.1, Ceiling insulation installed per303.2 imanufacturer'sinstructions.
[Fl2]r :Blown insulation marked every
300 fr,.
EComplies
lDoes Not
nNot Observable
!Not Applicable
Vented attics with air permeable
insulation include baffle adjacent
to soffit and eave vents that
extends over insulation.
402.2.3
tFt2212
ncomplies
nDoes Not
nNot Observable
flNot Applicable
Attic access hatch and door
insulation >R-value of the
adjacent assembly.
tnComplies
tnDoes Not
lnNot observable
rlNot Applicable
R-R-402.2.4
lFt3ll
Blower door test @ 50 Pa. <=5
ach in Climate Zones 1-2, and
<=3 ach in Climate Zones 3-8.
incomplies
t!Does trtot
:flNot Observable
1[JNot Applicable
ACH 50 =ACH 50 =402.4.1.2
lFt 17 11
Ducts are pressure tested to
determine air leakage with
either: Rough-in test: Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test: Total
leakage measured with a
:pressure differential of 0.1 inch
w.g. across the entire system
, including the manutacturer's air
handler enclosure.
cfm/100 cfm/100
ft2 ft2
403.3.3
lFt27l1
tlcomplies
nDoes Not
ENot Observable
rnNot Applicable
Duct tightness test result of <=4
cfm/100 ft2 across the system or
<=3 cfm/100 ft2 without air
handler @ 25 Pa. For rough-in
'tests, verification may need to
occur during Framing lnspection.
cfm/100
ft2 ft2 IDoes Not
403.3,4
lFt4lr
tnNot Observable
lnNot Applicable
cfm/100 t[JComplies
Air handler leakage designated
by manufacturer at <=2Yo of
design air flow.
nComplies
nDoes Not
nNot Observable
flNot Applicable
403.3.2.1
lFt24l1
Programmable thermostats
installed for control of primary
heating and cooling systems and
initially set by manufacturer to
code cations.
403.1.1
lFtel2
Ecomplies
nDoes Not
!Not Observable
[]Not Applicable
Heat pump thermostat installed
on heat pumps.
403,1,2
lFt1012
EComplies
nDoes Not
flNot Observable
nNot Applicable
Circulating service hot water
systems have automatic or
accessible manual controls,
403.5.1
lFt1112
nComplies
lDoes Not
INot Observable
nNot Applicable
1 lm ct (Tier 1)H 2 3 Low I (Tier 3)Medium (Tier 2)
Project Title: 9023 County RD 3l-2_REscheck_061924
Data filename:
Report date: OGIL9/24
Page 8 of10
Section
#
& Req,lD
Final Inspection Provisions Plans Verified
Value
Field Verified
Value Complies?Comments/Assumptions
403.6.1
lFt25l2
All mechanical ventilation system
fans not part of tested and listed
HVAC equipment meet efficacy
and air flow limits per Table
R403.6.1.
nComplies
EDoes Not
!Not Observable
nNot Applicable
403.2
lFt2612
Hot water boilers supplying heat
through one- or two-pipe heating
systems have outdoor setback
control to lower boiler water
temperature based on outdoor
tem perature.
nComplies
nDoes Not
nNot Observable
ENot Applicable
403.5.1.1
lFl28l2
Heated water circulation systems
have a circulation pump. The
system return pipe is a dedicated
return pipe or a cold water supply
pipe. Gravity and thermos-
syphon circulation systems are
not present. Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy. Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
!Complies
nDoes Not
ENot Observable
nruot Applicable
403.5.r.2
I Ft29]2
Electric heat trace systems
comply with IEEE 515.1 or UL
515. Controls automatically
adjust the energy input to the
heat tracing to maintain the
desired water temperature in the
piping.
lComplies
nDoes Not
nNot Observable
lNot Applicable
403.5.2
lFt3ol2
Demand recirculation water
systems have controls that
manage operation of the pump
and limit the temperature of the
water entering the cold water
piping to <= 1044F.
lComplies
EDoes Not
!Not Observable
nNot Applicable
403.5.4 Drain water heat recovery units
tested in accordance with CSA
855.1. Potable water-side
pressure loss of drain water heat
recovery units < 3 psi for
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units < 2 psi for
individual units connected to
three or more showers.
nComplies
EDoes Not
nNot Observable
nNot Applicable
I F r31],
404.t
lFt6li
90Yo or more of permanent
fixtures have high efficacy lamps.
nComplies
nDoes Not
!Not Observable
ENot Applicable
404.r.1
I Ft23]3
'?
Fuel gas lighting systems have
no continuous pilot light.
nComplies
nDoes Not
nNot Observable
nNot Applicable
401.3
[Ft712
Compliance certificate posted lComplies
EDoes Not
ENot Observable
nNot Applicable
3 (Tier 3)Low1lmpact (Tier 1)H 2 Medium (Tier 2)
Project Title: 9023 County RD 312_REScheck_061924
Data filename:
Report date: 06119124
Page 9 of10
Manufacturer manuals for
mechanical and water heating
systems have been provided,
Additional Com ments/Acsu m ptionsr
1 Low
Project Title: 9023 County RD 312_REscheck-06L924
Data filename;
Report date: A-AILgl?4
Page 1.0 of1.0
fr 2018 IECC Energy
Efficiency Certificate
Above-Grade Wall
Below-Grade Wall
Floor
Ceiling / Roof
Ductwork (unconditioned spaces):
Window
Door
Heating System
Cooling System
Water Heate
Name:
Comments
27.OO
o.oo
10.o0
49.OO
o.27
o.35
Date:
lnsulation Rating R-Value
Glass & Door Rating U-Factor SHGC
Heating & Cooling Equipment Efficiency