Loading...
HomeMy WebLinkAboutEngineer's Foundation Letter-Rebar STRUCTURAL CLARIFICATION ITEM #1 Date: July 1, 2024 Project: Smith Prairie Custom 9999 County Rd 115 Carbondale, CO 81623 Project Number: 23-12-163 To: Mike Huitt MHCI – Mike Huitt Construction Inc. PO Box 1456 Sisters, OR 97759 From: J. Jacob Baglien, P.E. C: Re: GFRP Rebar Switch Reference signed and sealed construction documents dated June 3, 20204: 1) Provide MST-BAR Grade III GFRP rebar as an alternative to horizontal steel reinforcement in the footing and wall steels. All vertical, dowel, and tie reinforcement shall remain steel for this project. See the specification sheet provided. Please call with any specific questions. Attachment: MST-BAR Spec sheet END OF STRUCTURAL CLARIFICATION ITEM #1 IMPERIAL #2 #3 #4 #5 #6 #7 #8 #9 #10 #11 METRIC 6 10 13 16 20 22 25 29 32 36 Minimum Tensile Load kN 33 74 132 202 285 390 507 650 819 1000 lbf 7419 16636 29675 45411 64070 87675 112180 146126 184118 224810 Cross Sectional Area mm2 32 71 132 201 285 387 491 645 819 1007 Weight kg/m 0.12 0.22 0.35 0.5 0.7 0.9 1.22 1.4 1.72 2.15 Guaranteed Tensile Strength >1000 MPa >145 Ksi Strength of Bend (Straight Portion) >900 MPa Young's Modulus , E >60GPa >8702KSI Strength of Bend (Bend Portion with Minimum Radius Bend : 4x Diameter of Bar) >600 MPa Ultimate Strain , εfu >1.7% Transverse Shear Strength , τ >220 MPa 31.9 ksi Young's Modulus , E (Bend Bar) 50 GPa Bond Strength to Concrete 20 MPa Minimum 2900 Psi Minimum Glass Transition Temperature, Tg°125C° MST-BAR® Grade III GFRP sales@mstbar.com www.mstbar.com 416-740-0344 MST-BAR® Manufactured by MST Rebar Inc. The #1 Solution to Concrete Reinforcement