HomeMy WebLinkAboutOWTS Permit Card
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 0 County Road 236, Silt, CO 81652 Parcel No.: 217904300412
Owner Name: Pizarro Owner Phone: Not Provided
Designed By: CBO Inc. Designer Phone: (970) 309-5259
Contractor: Bernie Colonna Contractor Phone: (970) 319-8706
Employees: 6 Minimum Tank Capacity: 1,000-gallon Minimum Absorption: 420 ft2
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT-8711_______________________________
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date _07/03/2024____________________ Expiration Date_07/11/2025_________________
Permit Conditions:
Permit Conditions: This OWTS Permit is approved on the condition of compliance with the design as
submitted by CBO, Inc. dated April 30, 2024. Changes must be approved by Garfield County Public
Health and the designer prior to construction.
The new OWTS will serve a new commercial office with a toilet and a sink serving six employees. The
system will consist of a new, two-compartment 1,000-gallon septic tank set level with access to
grade and an effluent filter in the outlet tee of the tank. Effluent will gravity flow to a distribution
box set level with access to grade that will distribute effluent to 432 ft2 of STA. The new STA will
consist of 3 gravelless trenches consisting of 12 Quick4 chambers, for a total of 36 Quick4 chambers.
Inspection ports are to be installed at each end of each trench. Maintain all setbacks and elevations
as designed.
To assist in scheduling, please contact Garfield County Public Health (970-945-6614 ext. 8150) to
notify the start of OWTS construction. Contact the designer and Garfield County Public Health at
least 48 hours prior to requesting final inspection of the installed system prior to backfill. NO OWTS
COMPONENT SHALL BE BACKFILLED WITHOUT PRIOR APPROVAL FROM GARFIELD COUNTY PUBLIC
HEALTH AND THE DESIGNER.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction, and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection,
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as-built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
07/03/2024
Issued By: Garfield County Environmental Health
Department
Date