HomeMy WebLinkAboutEngineer's OWTS Design PlanS S S S EX. 1500 GALLON SEPTIC TANK TO REMAIN. INSTALL AN EFFLUENT FILTER IN THE VERTICAL OUTLET TEE. EX. SEWER PIPE TO REMAIN PR O P E R T Y L I N E ( S H O W N P E R C O U N T Y G I S . C O N T R A C T O R T O F I E L D V E R I F Y ) 10 0 ( 4 x 2 5 ) Q U I C K 4 I N F I L T R A T O R OR 8 0 ( 4 x 2 0 ) A D S A R C 3 6 U N I T S (B O T T O M A R E A T O B E L E V E L ) 10' MIN FROM PROPERTY LINE INSPECTION PORT AT EACH END OF EACH LATERAL, BOTH ENDS OF EACH BED, TYP. 4"Ø SDR35 PVC DISTRIBUTION LATERAL, BOTH END OF EACH BED, TYP. 10 ' APPROXIMA T E L O C A T I O N O F E X . G R A V E L ABSORPTIO N F I E L D ( R E T I R E I N P L A C E ) EX. PRIMARY RESIDENCE (4-BEDROOMS) EX. GARAGE/ADU (2-BEDROOMS) 4' ' Ø 4' ' Ø 4' ' Ø 4' ' Ø 4' ' Ø 4' ' Ø 4' ' Ø TWO-WAY DISTRIBUTION BOX 4"Ø SDR35 PVC SEWER @ 2%. MIN. C/ O INSTALL A TWO-WAY CLEANOUT NEAR THE BEND C / O EX. CLEANOUT TO REMAIN SALVAGE AND REUSE THE ORIGINAL 1000 GALLON SEPTIC TANK (ALSO REMOVE THE INTERIOR BAFFLE) OR INSTALL A NEW 1000 GALLON ONE-COMPARTMENT SEPTIC TANK UPSTREAM OF THE EX. TANK EX. WELLS ARE MORE THAN 100' AWAY FROM THE PROPOSED ABSORPTION FIELD(S) EX. SOLAR ARRAY EX. SOLAR ARRAY EX. GARDEN 4"Ø SDR35 PVC SEWER @ 2%. MIN. 10 0 ( 4 x 2 5 ) Q U I C K 4 I N F I L T R A T O R OR 8 0 ( 4 x 2 0 ) A D S A R C 3 6 U N I T S (B O T T O M A R E A T O B E L E V E L ) 1098 CR#214 County of Garfield, State of Colorado Parcel No: 2179-031-00-006 Silt 37110DERIC J O N WA L T E R COL O R A D O LICE N S E D P R O F E SSIONA L E N G INEER 06/06/24 NORTH By Re v i s i o n No . Da t e 923 Cooper Avenue Suite 201 Glenwood Springs, CO 81601 tele: 970.945.5252 fax: 970.384.2833 Engineer or Surveyor Seal Sheet Client Information: PROJECT NO. FILE NAME: Designer: Drafter: Date: N: \ P R O J E C T S \ 2 0 2 4 \ 2 4 0 1 0 - S e l f O W T S \ d w g \ 2 4 0 1 0 - V - T o p o . d w g 7/ 2 / 2 0 2 4 1 2 : 5 9 P M 9.8.7.6.5.4.3.2. 06/06/24 DJW DJW 24010-v-topo.dwg 24010 970.274.0064 Silt, CO 81652 1098 CR#214 Stephen Self GA R F I E L D C O U N T Y , C O L O R A D O 1. On s i t e W a s t e w a t e r T r e a t m e n t S y s t e m ( O W T S ) 10 9 8 C o u n t y R o a d # 2 1 4 C.1 00 30'60' Scale: 1" = 30' SITE EVALUATION 1.SITE AND SOIL EVALUATIONS WERE PERFORMED BY: DERIC J. WALTER, PE KEVIN DYE, PE BOUNDARIES UNLIMITED INC.GEO QUEST 923 COOPER AVE., STE. 201 PO BOX 1372 GLENWOOD SPRINGS, CO 81601 RIFLE, COLORADO 81650 970.945.5252 970.318.6784 2.EVALUATION DATE(S): MAY 27, 2024. 3.SETBACK REQUIREMENTS FOR A TREATMENT LEVEL 1 STA TRENCH/BED, UNLINED SAND FILTER OR SEEPAGE PIT (PER TABLE 7-1) AND AN ADWF=825 GPD: 3.A.SPRING, WELL OR POTABLE CISTERN=100' 3.B.POTABLE WATER SUPPLY LINE=25' 3.C.STRUCTURE W/ BASEMENT/CRAWL SPACE=20' 3.D.STRUCTURE W/O BASEMENT/CRAWL SPACE=10' 3.E.PROPERTY LINE, PIPE OR LINED IRRIGATION DITCH=10' 3.F.INTERMITTENT IRRIGATION LATERAL, INFILTRATION STRUCTURE=25' 3.G.LAKE, WATER COURSE, IRRIGATION DITCH, STREAM OR WETLAND=50' 3.H.DRY GULCH, CUT BANK OR FILL AREA=25' 3.I.SEPTIC TANK=5' 3.J.RESTRICTIVE LAYER OR GROUNDWATER (VERTICAL): 4' (TREATMENT LEVEL 1, GRAVITY FEED) 3.SETBACK REQUIREMENTS FOR THE SEPTIC TANK SHALL BE (PER TABLE 7-1): 3.A.SPRING, WELL OR POTABLE CISTERN=50' 3.B.POTABLE WATER SUPPLY LINE=10' 3.C.STRUCTURE W/ BASEMENT/CRAWL SPACE=5' 3.D.STRUCTURE W/O BASEMENT/CRAWL SPACE=5' 3.E.PROPERTY LINE, PIPE OR LINED IRRIGATION DITCH=10' 3.F.INTERMITTENT IRRIGATION LATERAL, INFILTRATION STRUCTURE=10' 3.G.LAKE WATER COURSE, IRRIGATION DITCH, STREAM OR WETLAND=50' 3.H.DRY GULCH, CUT BANK OR FILL AREA=10' 3.I.STA TRENCH/BED, UNLINED SAND FILTER OR SEEPAGE PIT=5' SURFACE 12" Scale: N.T.S. Site & Soils Evaluation SOIL EVALUATION 1.SOIL WAS CLASSIFIED BY THE GEOTECHNICAL ENGINEER (GEO QUEST (PROJECT #24-157, MAY 27, 2024) AS USDA CLAY LOAM; TYPE 3A; WITH AN LTAR OF 0.30 GPD/SF. 9' ± SYSTEM DESIGN & CONSTRUCTION NOTES: 1.THIS DESIGN IS FOR A REPLACEMENT ABSORPTION FIELD. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH CDPHE REGULATION 43 ONSITE WASTEWATER TREATMENT SYSTEM (OWTS) REGULATION, MOST CURRENT EDITION AND LOCAL AGENCY REQUIREMENTS WHICH MAY OR MAY NOT SPECIFICALLY BE NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR KNOWING AND CONFORMING TO SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS. THIS DRAWING DOES NOT CONSTITUTE AN OWTS PERMIT. A PERMIT MUST BE OBTAINED FROM APPROPRIATE LOCAL AGENCY. THE CONTRACTOR MUST CONTACT THE LOCAL AGENCY HEALTH DEPARTMENT AND THE PROJECT ENGINEER FOR INSPECTIONS OF THE CONSTRUCTED SYSTEM BEFORE BACKFILL. A REQUEST FOR INSPECTION BY THE PROJECT ENGINEER AND THE COUNTY ENVIRONMENTAL HEALTH OFFICER MUST BE MADE AT LEAST 72-HOURS PRIOR TO THE DESIRED TIME OF BACKFILLING. 2.DEMAND CALCULATIONS (SEC.43.6.A.2.h) 2.A.FOUR (4) BEDROOM PRIMARY RESIDENCE AND A TWO (2) BEDROOM ADU USING TREATMENT LEVEL 1 (TL1). 2.B.AVERAGE DAILY WASTEWATER FLOW (ADWF) AND ORGANIC LOAD RATE (BOD5): 2.B.1.SINGLE FAMILY DWELLING: 75 gpdc & 0.20 BOD5 lbs/day 2.B.2.ADWF: 2.B.2.1.PRIMARY RESIDENCE = 75 gpd * (3 BEDROOMS * 2 PERSONS/BEDROOM + 1 BEDROOM * 1 PERSONS/BEDROOM) = 525 gpd 2.B.2.2.ADU = 75 gpd * (2 BEDROOMS * 2 PERSONS/BEDROOM ) = 300 gpd 2.B.2.3.TOTAL= 825 gpd 2.B.3.BOD5 = 0.20 lbs/day * 11 PERSONS = 2.20 lbs/day BOD5 mg/L = BOD5*1,000,000 = 2.20 lbs/day*1,000,000 = 319.74 mg/L ADWF*8.34 825 gpd*8.34 2.B.4.CBOD5 = BOD5 * 0.85 = 272 mg/L 3.SEPTIC TANK (SEC.43.9.B.2.a): 3.A.48-HOURS OF MINIMUM DETENTION TIME: ADWF * 48 hrs/24 hrs = 825 * 48 hrs/ 24 hrs = 1650 GALLONS. 3.B.EXISTING TANK IS 1,500-GALLON TWO COMPARTMENT TANK (SEPT-12-77-5046). INSTALL A 1,000 GALLON ONE-COMPARTMENT TANK UPSTREAM OF THE EXISTING TANK. 3.C.THE TANK IS NOT SUBJECT TO BUOYANCY. 4.ABSORPTION AREA CALCULATIONS: 4.A.THE ABSORPTION AREA SLOPES GENTLY. 4.B.LONG TERM ACCEPTANCE RATE (LTAR) FOR TREATMENT LEVEL 1 (TL1) OF 0.30 gpd/SF (SEE SITE & SOILS EVALUATION NOTES/DETAIL). 4.C.MINIMUM SOIL TREATMENT AREA, A: A = ADWF = 825 = 2,750 S.F. LTAR 0.30 gpd/S.F. 4.D.SIZE ADJUSTMENT FACTORS: GRAVITY BED = 1.2; CHAMBERS = 0.7 (TABLE 10-1A). 4.D.1.A,adj = 2,750 SF * 1.2* 0.7 = 2,310 SF 4.E.GRAVELLESS CHAMBER BED SYSTEM: 4.E.1.INFILTRATOR QUICK4: 2,310 SF / 12 SF/UNIT = 193 UNITS. INSTALL 200 UNITS IN TWO (2) 4 x 25 UNIT BEDS. 4.E.2.ADS ARC 36: 2,310 SF / 15 SF/UNIT = 154 UNITS. INSTALL 160 UNITS IN TWO (2) 4 x 20 UNIT BEDS. 5.THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS (EXCLUDING SMALL UNDER-SINK) OR WATER SOFTENERS AND/OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM. 6.CLEAN OUTS ARE REQUIRED AT THE HOUSE AND AT ALL BENDS AND AT LEAST EVERY 100-FEET BETWEEN THE HOUSE AND THE SEPTIC TANK. 7.THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL WATER TIGHT COMPONENTS THROUGHOUT THE SYSTEM TO PREVENT INFILTRATION. 8.INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS PORTS TO FINAL GRADE. PORTS SHALL BE MARKED IF CAPS ARE TO BE BURIED. 9.INSTALL 3-INCHES OF BLUEBOARD INSULATION, 3-FEET WIDE, OVER SEWER AND EFFLUENT PIPE WHEREVER DEPTH IS LESS THAN 3-FEET. UNDER NO CIRCUMSTANCES SHALL COVER BE LESS THAN 2-FEET. 10.SITE PLAN INFORMATION FROM OTHERS. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED. NO R T H To New Castle I-70 SITE Vicinity Map 10 ' ± MAINTENANCE NOTES 1.TO ENCOURAGE THE HEALTH AND LONGEVITY OF THE OWTS SYSTEM, THE OWNER SHALL CONSIDER THE FOLLOWING: 1.A.MINIMIZE THE AMOUNT OF WATER THAT GOES DOWN THE DRAIN, THE BETTER YOUR SYSTEM WILL WORK. 1.B.MINIMIZE SOLIDS GOING DOWN THE DRAIN. 1.C.ELIMINATE GARBAGE DISPOSALS OR KEEP THE USE OF GARBAGE DISPOSALS TO A MINIMUM. 1.D.MINIMIZE GREASE AND OILS THAT GO DOWN THE DRAIN. 1.E.USE LINT FILTERS ON LAUNDRY MACHINE DRAINS. 1.F.KEEP SAND AND DIRT OUT OF THE BUILDING DRAIN. 1.G.AVOID FLUSHING SANITARY NAPKINS OR PAPER PRODUCTS OTHER THAN TOILET PAPER. 1.H.DO NOT USE LYE-BASED DRAIN UNCLOGGER CHEMICALS SUCH AS DRAINO, OVEN-OFF, OR OTHER STRONG CLEANING AGENTS. 1.I.DO NOT PUT ANY “ROOT DETERRENTS” DOWN THE DRAIN. 1.J.DO NOT POUR PAINT THINNER, PESTICIDES, PAINTS OR PHOTO LAB CHEMICALS DOWN THE DRAIN 1.K.MINIMIZE USE OF CHLORINE BLEACH AND TOILET ADDITIVES. 2.THE OWNER SHALL CONTRACT WITH A SEPTIC TANK INSPECTOR TO INSPECT THE TANK ANNUALLY FOR GREASE AND SEDIMENT ACCUMULATION. THE INSPECTOR SHALL REMOVED AND PROPERLY DISPOSED OF ACCUMULATED GREASE AND SEDIMENT AS NEEDED TO ENSURE PROPER FUNCTION OF THE SYSTEM. To Rifle TOPSOIL SC/CL SAND, CLAY, SILT, TAN, DRY TO MOIST, CALCAREOUS, ORGANICS FLOW ATTACH REMOVABLE CAP OR THREADED CLEANOUT ASSEMBLY. INSTALL MARKER IF CAP IS TO BE BURIED. FINISH GRADE 4"Ø PVC RISER 4"Ø PVC TWO-WAY CLEANOUT TEE 4"Ø SEWER LINE Scale: N.T.S. Two-Way Cleanout BOTTOM TO BE LEVEL AND FLAT OVER ENTIRE AREA TO WITHIN 0.1'±. (TYP.). IF NECESSARY TO ACHIEVE THIS SURFACE, IMPORT CONCRETE SAND TO USE AS LEVELING MATERIAL. REMOVE ANY ENCOUNTERED BOULDERS AND BACKFILL WITH LOAMY SAND OR SANDY GRAVELS. DO NOT USE COMPACTED MATERIALS. GENERAL ABSORPTION AREA NOTES 1.INSTALL CHAMBER UNITS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 2.ABSORPTION BEDS SHALL NOT EXCEED 12' WIDE BY 100-FEET IN LENGTH, SHALL PARALLEL THE TOPOGRAPHY AND SHALL BE INSTALLED IN A RECTANGULAR PATTERN WHENEVER POSSIBLE. 3.THE BOTTOM OF THE ABSORPTION BED SHALL BE LEVEL AND THE BOTTOM AND SIDEWALLS MUST BE RAKED TO REMOVE ANY SOIL SMEARS INCURRED DURING THE EXCAVATION. FAILURE TO DO SO MAY REQUIRE THE CONTRACTOR TO REPLACE THE ABSORPTION FIELD AT HIS/HER OWN EXPENSE. 4.DRAINAGE SWALES ARE TO BE PROVIDED ABOVE AND AROUND THE FIELD, AS NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING ABSORPTION AREA. 5.NO EXCAVATION OF THE ABSORPTION FIELD IS TO BE DONE DURING WET WEATHER AND USE OF RUBBER TIRE VEHICLES OVER THE ABSORPTION AREA IS STRICTLY PROHIBITED. 6.UNSUITABLE MATERIAL EXISTING WITHIN THE FIELD SHALL BE EXCAVATED AND BACKFILL SHALL CONSIST OF IMPORTED LOAMY SAND OR SANDY GRAVEL. THE ENGINEER SHALL BE CONTACTED IF BEDROCK OR GROUNDWATER IS ENCOUNTERED IN THE EXCAVATION. 7.TOPSOIL COVER MAY BE VARIED (1-FOOT MINIMUM, 2-FOOT MAXIMUM) TO ALLOW FOR LANDSCAPING. 8.WHEN MULTIPLE BEDS ARE USED, BEDS SHALL BE SEPARATED BY 6-FEET MIN. OF UNDISTURBED SOILS. 4"Ø PERFORATED PVC PIPE. EXTEND PIPE TO REST ON BOTTOM OF THE BED COVER WITH 6" OF TOPSOIL AND REVEGETATE 12 " M I N . , 24 " M A X . GRAVELLESS CHAMBER SYSTEM: INFILTRATOR QUICK 4, ADVANCED DRAINAGE SYSTEMS BIODIFFUSER (STANDARD), OR ENGINEER APPROVED EQUAL. FILL OVER THE CHAMBERS WITH UNCOMPACTED WELL GRADED LOCAL SOILS. 4"Ø COUPLING (UNION). USE A HOLE SAW TO CUT OUT CIRCLE OFF THE CENTER OF THE UNIT STANDARD INSPECTION PORT, TYP. (4"Ø PVC SOLID PIPE CUT TO FIT. LOCATE PER PLAN VIEW. ATTACH REMOVABLE CAP OR THREADED CLEANOUT ASSEMBLY. CIRCULAR IRRIGATION-STYLE VALVE BOX & COVER - LID COLOR PURPLE OR GREEN - LABEL "SEWER" Scale: N.T.S. Gravelless Chamber Absorption Bed NOTE: A 1000-GALLON LOW PROFILE SINGLE COMPARTMENT NORWESCO POLYETHYLENE RESIN TANK IS ALSO ACCEPTABLE.