Loading...
HomeMy WebLinkAboutConditions of PermitCONDITION OF PERMIT BLRE-06.24-87 48 JOHN MATUSZESKI Residential Remo del / Addition 131 Buck Point Rd, Carbondale Panorama Ranches, Lot 7 1) ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE (I.R.C.) AND 2O1B INTERNATIONAL ENERGY CONSERVATION CODE (I.E.C.C.) 2) PROPOSED TMPROVEMENTS ARE SUBJECT TO ALL APPLTCABLE |TEMS CONTAINED lN THE ATTACH ED "GARFIELD COUNTY BUI LDING REOU I REM ENTS'. NU MBER REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST. 3) ELECTRTCAL pERMTTTTNG AND TNSPECTTONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY. 4) ALL EXTERIOR LIGHTING TO BE DOWNCAST AND SHIELDED. S) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLYWITH WILDFIRE MITIGATION AND DEFENSIBLE SPACE REOUIREMENTS OF THE COLORADO STATE FOREST SERVICE AND LOCAL FIRE DISTRICT. SEE GARFIELD COUNTY COMMUNITY DEVELOPMENT DEPARTMENT WEBSITE FOR FURTHER INFORMATION. 6) STORAGE LOFTS OVER MAIN LEVEL LIVING HAVE BEEN REVIEWED FOR NON-HABITABLE STORAGE USE ONLY; STORAGE LOFTS ARE NOT APPROVED FOR HABITABLE LIVING. 7) OPEN HOLE SOTLS REPORT REOUTRED AT FTRST FOOTTNG |NSPECTION, 1,500 PSF SOIL BEARING CAPACITY. B) VER|Fy NO CONSTRUCTTON PARKTNG / STAGTNG AREA OVER THE EXTSTTNG SEPTIC TANK AND LEACH FIELD AREA. 9) GENERAL CONTRACTOR MUST ENSURE SEPTIC TANK / CLEAN OUT ACCESS IS NOT DISRUPTED OR IMPEDED BY THE NEW DECK / HOT TUB OUTDOOR STRUCTURE(S). CONTACT GARFIELD COUNTY ENVIRONMENTAL HEALTH DEPARTMENT SHOULD YOU HAVE OUESTIONS OR CONCERNS ABOUT THE ATTACHED TABLE 7-1 (REFERENCE MATERIAL FOR ON-SITE WASTEWATER TREATMENT SYSTEMS). ,IO) GENERAL CONTRACTOR SHALL MAINTAIN MINIMUM REOUIRED SETBACK AS DESCRIBED (ATTACHED RECORDED) FINAL PLAT FOR PANORAMA RANCHES. $ stt $ N tuailD 43.7Minimum Dlsfances Between Components of an On-site Wastewater Treatment System and Features Table 7-1 Minimum Horizontal Distances in Feet Between Gomponents of an On-Site Wastewater Treatment System lnstalled After November 15 1973 and Water and Health Features $ N s 'N Lined Evapo- transpiration Field or Outside of Berm of Lined Wastewater Pond Lined Sand Filter STATrench, STA Bed, Unlined Sand Filter, Sub-surface Dispersal System, Seeoaoe Pit Building Sewer or Effluent Lines Septic Tank, Higher Level Treatment Unit, Dosing Tank, Vault or Vault Privy Unlined Sand Filter in SoilWith a 60 100 3 502 502 Spring, Well,l Suction Line, Potable Water Supply Cistern4 100 60 rc2 252 56 fi2 Potable Water Supply Line 2 252 rc2 15 20 0 5 Structure w/basement, crawl space or footing drains 15 15 10 0 5 Structure without basement, crawl space or footing drains 15 15 10 fi2 10 Property Lines, Piped or Lined lrrigation Ditch, upslope curtain drain 10 10 10 10 fi2 10 Subsurface Drain, lntermittent lrrigation Lateral, Drywell, Stormwater Structure 25 10 10 25 Lake, Water Course, lrrigation Ditch, Stream, Wetland 25 25 25 503 502 50 10 Dry Gulch, Cut Bank, FillArea (from Crest) 15 10 10 25 rc2 5 5 Septic Tank, Higher level treatment Unit, Dosing Tank, Vault or Privy 10 5 42 43.7Minimum Disfances Between Components of an On-site WastewaterTreatment Sysfem and PhysicalFeatures 4 All horizontal setbacks to a potable urater supply cistem must be met unless a variance by the Board of Examiners of Waterwell Construction and Pump lnstallation '11 .4 of the Water Well Construction Rules, as applicable. The minimum horizontal setback that may be granted through a variance is to 25 feet. 5 If the structure is not used as a habitable unit, the isolation may be reduced by the local board of health to no less than 50 feet. 6. Building sewer installations shall meet the design requirements of the Colorado Plumbing Code. 44