BLRE-0 6-24-8735
JAMES MARTINEZ
New Single-family dwelling w/ attached garage
52 Hogan Dr, Parachute
Fairways Subdivision, Ph 1, Block 2, Lot 6
1) ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE (I.R.C.)
AND 201B INTERNATIONAL ENERGY CONSERVATION CODE (I.E.C.C.)
2) PROPOSED TMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED lN THE
ATTACH ED "GARFIELD COU NTY BU I LDING REOUIREMENTS". NUM BER REFERENCES
NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) ELECTRTCAL pERMtTTtNG AND TNSpECTTONS BY COLORADO STATE ELECTRIC BOARD.
ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL
FINALAPPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.
4) ALL EXTERIOR LIGHTING TO BE DOWNCAST AND SHIELDED.
S) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLY WITH WILDFIRE
MITIGATION AND DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE
FOREST SERVICE AND LOCAL FIRE DISTRICT. PLEASE REFER TO THE GARFIELD COUNTY
COM M U NITY DEVELOPM ENT WEBS ITE FOR ADDITI ONAL I N FORMATIO N.
6) OPEN HOLE SOTLS REPORT tS REOUTRED AT FOOTING TNSPECTION AND PRIOR TO ANY
CONCRETE POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE
BUILDING INSPECTOR. 1,500 PSF soil bearing.
7) PRE-ENGTNEERED ROOF TRUSSES. HAVE ENGTNEERTNG FOR BUILDING INSPECTOR AT
TIME OF FRAME INSPECTION.
g) SHEET 41, U34B FIRE WALL SECTTON DETAIL SEE RED LINES AND. MINERAL WOOL
REOUIRED WHEN USING LP FLAMEBLOCK. INTERTEK REPORT ATTACHED FOR FURTHER
ASSEMBLY.
9) ROOF EAVE PROJECTTNG OVER THE PROPERTY LINE (NORTH SIDE LOT LINE) SHALL BE
CONSTRUCTED WITH FULL ONE-HOUR ASSEMBLY (lN NEIGHBORING LOT 3 FT
MAINTENANCE EASEMENT). REFERENCE SITE PLAN "CLOUDING" AND SHEET 43.
10) ROOF DRATNS AND DOWNSPOUTS TO DRAIN WATER ONTO LOT 6. OWNER BUILDER
SHALL NOT DIRECT DRAINAGE ONTO ADJACENT LOTS.
1 1) A LOT TMPROVEMENT CERT|F|CATE, SEALED BY A COLORADO LICENSED SURVEYOR, lS
REOUIRED AT FOUNDATION INSPECTION TO VERIFY STRUCTURE IS IN COMPLIANCE WITH
MINIMUM SETBACK REOUIREMENTS / BUILDING ENVELOPE.
12) BLOWER DOOR TEST tS REOUTRED. MUST SUBMIT BLOWER DOOR TEST REPORT TO
GARFIELD COUNTY COMMUNIry DEVELOPMENT DEPT. OFFICE PRIOR TO SCHEDULING
FINAL BUILDING INSPECTION / C.O. FINAL.
13) pRESCRtpTtVE PATH USTNG 2018 |ECC R402.1.2 HAS BEEN CHOSEN FOR ENERGY
COMPLIANCE OF THIS HOME DESIGN. MANUAL J REPORT ALSO ATTACHED FOR
REFERENCE. ALL NEW HOMES TO HAVE WHOLE-HOUSE MECHANICAL VENTILATION
SYSTEM INSTALLED (2015 IRC TABLE m1507.3.3(1)AND (2)SHOWN ON COVER SHEET.
$
N
.{,tt
.s
hr/ptnail
Division 6 Wood, Plastics and Composites
0616 00 Sheathing
06 16 36 Wood Panel Product Sheathing Page I of3
Design No. LPBMPPS 60-01
Loadbearing Wall AssemblY
LP Building Products
LP@ FlameBlock@ Fire-Rated OSB Sheathing
ASTM E.l19
Restricted
Assembly Rating-1 hour
Load - maximum q.aW of desiqn loadr
1 Design Load calculated per sections 3.6 and 3.7 of ANSI/AF&PA NDS-05
Date Revised: August 31 ,2012
Project No: 1 0071 1 1 675AT-0068 lntertek
@lntertek
Division 6 Wood, Plastics and Composites
06 16 00 Sheathing
06 16 36 Wood Panel Product Sheathing
1. WALL ASSEMBLY: Construct a t hour
rated gypsum wall assembly using the
following elements:
A. WOOD STUDS: lnstall nominal
2 in. x 6 in., Number 2 Douglas Fir
wood studs spaced 16 in. on center.
Attach each wood stud to top and
bottom wood plates using three (3)
16d framing nails at each location.
Construct top plate of two (2) wood
studs installed horizontally at the top
of the gypsum wall assembly and
the bottom plate of a single wood
stud. lnstall nominal 2 in. x 6 in.
wood studs horizontally as cross-
bracing positioned at mid-height of
the wall.
B. GYPSUM BOARD: lnstall one layer
ot nomrnal 5/8 in. thick Type X
gypsum board, oriented vertically.
Secure gypsum board using
nominal 1-718 in. long cup-head
drywall nails spaced nominally 8 in.
on center
C. Joint Tape and compound (Not
snown); lnstali vinyi or casein, dry or
premixed joint compound applied to
exterior face of gypsum board in two
coats to all exposed fastener heads
and gypsum board joints. lnstall
minimum 2 in. wide paper, plastic or
fiberglass tape embedded in the first
layer of compound over joints in
gypsum board.
D. INSULATION: lnstall nominal
5'-1 l2 in thick naminal ) E nnfrvl
density unfaced mineral fiber batt
insulation friction fit between the
wood studs (ltem 1A).
E. CERTIFIED MANUFACTURER: LP
Building Products
CERTIFIED PRODUCT: Wood
Sheathing, Fire Retardant Coated
Sheathing
Date Revised: Auoust 31 ,2012
Pro,lect No: 1 0071 '1 167S4T-0068
Page 2 of 3
MODEL: LP@ FlamcBlock@ Fire-
Rated OSB Sheathing
lnstall nominal 48 in. wide x 96 in.
tall, nominal 7116 in. minimum thick
sheathing with the white side facing
out. lnstall sheathing staggered at
gypsum seams. Secure sheathing to
wood studs (ltem 1A) using 1-7l8 in.
long 6d nails spaced 6 in. on center
around the perimeter and 12 in. on
center in the field. Alternatively, use
8d or 10d nails and the same
spacing noted previously.
F. VAPOR BARRIER: lnstall Tyvek @
HomeWrap @ vapor barrier fastened
over the sheathing (ltem 1E) using
sufficient fasteners to prevent air
pockets in the wrap,
2. EXTERIOR WALL COVERING: lnstall
one of the following items on the
exterior side of the wall assembly (ltem
'1 ):
A. STEEL SIDING: lnstall nominal
38-112 in. wide x 10 ft long, 26 GA
steel siding with minimum 36 in.
coverage. Attached siding to wood
studs (ltem 1A) over the vapor
barrier (ltem 1E), using 1-718 in.
long self tapping drywall screws,
two per panel per stud.
B. T1-11 SIDING: lnstall minimum
5/16 in. thick plywood or OSB siding
per the manufacturer's published
installation instructions.
C. FIBER CEMENT BOARD: lnstall
minimum 5/16 in. thick cellulose
fiber-reinforced cement board per
the manufacturer's published
installation instructions.
D. WOOD FIBER PANEL: lnstall
minimum 5/16 in. thick zinc borate
coated wood strand or wood fiberpanel per the manufacturer's
published installation instructions.
@8 @lntertek
Division 6 Wood, Plastics and Composites
06 16 00 Sheathing
06 16 36 Wood Panel Product Sheathing
E. CEMENT PLASTER (STUCCO):
lnstall three-coat cement plaster
(stucco) over metal lath or wire
fabric lath and water resistive barrier
as required by the lnternational
Building Code (lBC). Alternatively,
install Omega Products
lnternational, lnc. Omega Diamond
Wall or Diamond Wall PM lnsulating
Exterior Stucco Systems in
accordance with manufacturer's
installation instructions and with the
following requirements:
1. lnstall a water resistive barrier
as required by the IBC for
installation over wood based
sheathing.2. lnstall metal lath or wire fabric
lath as required for compliance
with the lBC. Fasten lath
through the sheathing to the
studs with 1-114 in. long, 0.125
in. diameter nails having
minimum head diameters of
0.355 in. or No. 16 GA,
corrosion resistant staples
having 15116 in. crowns.
Fasteners spaced 6 in. on
center on the studs and
perimeter framing.
3. Apply Diamond Wall coating a
minimum of 3/8 in. thick in
accordance with the
manufactu rer's instructions.
Date Revised: August 31, 2012
Prolect No: 10071 1 1675,4T-0068
Page 3 of 3
@lntertek