Loading...
HomeMy WebLinkAboutConditions of PermitcoNDrTro NS OF PERMIT BLRE-06-24-87 54 Miguel Rojo & Miguel Salvidrez New Single-family dwelling w/ attached garage 129 Sage Meadow Rd Pinyon Mesa PUD, Flg 1 , Lot 14 1) ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE (I.R.C.)AND 2018 I NTERNATIONAL ENERGY CONSERVATION CODE (I,E.C.C.) 2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE ATTACHED "GARFIELD COUNTY BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST. 3) ELECTRTCAL PERMtTTtNG AND TNSPECTTONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY. 4) ALL EXTERTOR LIGHTING TO BE DOWNCAST AND SHIELDED. 5) WILDFIRE MITIGATION REOUIRED PER SUBDIVISION PLAT NOTE #10: SHALL COMPLY WITH WILDFIRE MITIGATION AND DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE DISTRICT. PLEASE REFER TO THE GARFIELD COUNTY COMMUNIry DEVELOPMENT WEBSITE FOR ADDITIONAL INFORMATION. 6) OPEN HOLE SOTLS REPORT rS REOUTRED AT FOOTING TNSPECTTON AND PRIOR TO ANY CONCRETE POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE BUILDING INSPECTOR. 1,200 PSF soil bearing. SHALL INCLUDE COMPACTION REPORT FOR ANY STRUCTURAL FILL 7) PRE-ENGTNEERED ROOF TRUSSES. HAVE ENGTNEERING FOR BUILDING INSPECTOR AT TIME OF FRAME INSPECTION. 8) BLOWER DOOR TEST lS REOUtRED. MUST SUBMIT BLOWER DOOR TEST REPORT TO GARFIELD COUNTY COMMUNIry DEVELOPMENT DEPT. OFFICE PRIOR TO SCHEDULING FINAL BUILDING INSPECTION / C.O. FINAL. 9) A LOT IMPROVEMENT CERTIFICATE, SEALED BYA COLORADO LICENSED SURVEYOR, IS REOUIRED AT FOUNDATION INSPECTION TO VERIFY STRUCTURE IS IN COMPLIANCE WITH THE PLATTED BUILDING ENVELOPE. 10) AN ELEVATTON SURVEY, SEALED BY A COLORADO PROFESSTONAL LTCENSED SURVEYOR, lS REQUIRED AT FRAME INSPECTION TO VERIFY THAT AS.BUILT ROOFS COMPLY WITH GARFIELD COUNTY'S 25-FOOT BUILDING HEIGHT LIMIT AS DEFINED IN THE LAND USE DEVELOPMENT CODE. 1 1) GARAGE ATTTC SPACE tS FOR NON-HABTTABLE GARAGE STORAGE ONLY. SA|D SPACE lS NOT APPROVED FOR FUTURE USE AS RESIDENTIAL LIVING SPACE. 12) CURRENT AND FUTURE OWNER'S ADVISED THE ORIGINAL BUILDING DESIGN HAS NEARLY MAXIMIZED THE ALLOWABLE RESIDENTIAL LIVING SPACE PER PUD GUIDE REGULATIONS. 13) PRESCR|pTtVE PATH USTNG 2018 tECC TABLE R402j.2 HAS BEEN CHOSEN FOR ENERGY COMPLIANCE OF THIS HOME DESIGN. MANUAL J REPORT AISO ATTACHED FOR REFERENCE, ALL NEW HOMES TO HAVE WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM INSTALLED (2015 IRC TABLE m1507.3.3(1)AND (2) SHOWN ON COVER SHEET. "*$ N