HomeMy WebLinkAboutEngineer's Proof Roll ReportsSoil SubgradeCourse Observed: SkylineEarthwork Contractor:Performed by:John Riley Proof Roll Equipment:Front End Loader Location:North Sidewalk/ Pavement/ Apron Subgrade (See attachment) Proof Roll Equipment: Compaction Testing: Subgrade Grading: Deflection: Elapsed Time/Weather: *Subgrade Grading conformance indicates that work to shape the subgrade to the planned cross-section was completed. No surveying or elevation validation of was performed by GROUND Engineering Consultants, Inc. Name Company On-Site Notifications Dwayne Felker Tectonic Management Group, Inc. Kelly Skyline Conforms Does Not Conform Not Applicable Not Observed Proof Roll Conformance Conformance Comments Noticeable deflection occurring along North side of building. Deflection extends approximately 20’ out from the entire length of building (see attachment). Material needs to pass a proof roll prior to any additional placements. Photos Highlighted equals area proof rolled. Blue area equals approximate 20’ section from building with observed deflection. Area observed with severe deflection. Tectonic Management Group, Inc. 6695 W. 48th Avenue Wheat Ridge, CO 80033 Nicholas Marquez Atlantic Aviation Hangar 6 Client: Report Date:Work Order No.: Proof Roll 23-6522.ProofRoll.0002; ver: 1Mar 21, 2024 Reviewed by:Chris HuttoWork Order Date:Mar 21, 2024 Results apply only to the specific items and locations referenced and at the time of testing, observations or special inspections. This report should not be reproduced, except in full, without the written permission of GROUND Engineering Consultants, Inc. 41 Inverness Drive East, Englewood, Colorado www.groundeng.com 303-289-1989 Englewood | Commerce City | Loveland | Granby | Gypsum | Colorado Springs Page 1 of 1 Soil SubgradeCourse Observed: Tectonic Management GroupEarthwork Contractor:Performed by:John Riley Proof Roll Equipment:Front End Loader Location: Comments: North sidewalk apron subgrade(See attached map) Skyline contracting previously excavated 2’ of soft subgrade materials at designated location(see attached map). The removed material was replaced with approximately 2’ of Class 6 ABC. Conducted proof roll over designated location and area is now within conformance. Proof Roll Equipment: Compaction Testing: Subgrade Grading: Deflection: Elapsed Time/Weather: *Subgrade Grading conformance indicates that work to shape the subgrade to the planned cross-section was completed. No surveying or elevation validation of was performed by GROUND Engineering Consultants, Inc. Name Company On-Site Notifications Dwayne Felker Tectonic Management Group, Inc. Kelly Skyline Contracting Inc Conforms Does Not Conform Not Applicable Not Observed Proof Roll Conformance Photos Highlighted equals area represented. Tectonic Management Group, Inc. 6695 W. 48th Avenue Wheat Ridge, CO 80033 Nicholas Marquez Atlantic Aviation Hangar 6 Client: Report Date:Work Order No.: Proof Roll 23-6522.ProofRoll.0003; ver: 1Mar 28, 2024 Reviewed by:Chris HuttoWork Order Date:Mar 27, 2024 Results apply only to the specific items and locations referenced and at the time of testing, observations or special inspections. This report should not be reproduced, except in full, without the written permission of GROUND Engineering Consultants, Inc. 41 Inverness Drive East, Englewood, Colorado www.groundeng.com 303-289-1989 Englewood | Commerce City | Loveland | Granby | Gypsum | Colorado Springs Page 1 of 1