BLRE-06-24-87 62
KELLY CON LEY
GARAGE / MASTER SUITE ADDITION
3200 H*y 325, Rifle
2127 18200027
1 ) ALL WORK SHALL COMply WITH THE 2015 TNTERNATTONAL RESTDENTIAL CODE (r.R.C.) AND 2018
INTERNATIONAL ENERGY CONSERVATION CODE (I.E.C.C.)
2) PROPOSED TMPROVEMENTS ARE SUBJECT TO ALL APPLTCABLE ITEMS CONTATNED lN THE
ATTACHED "GARFIELD COUNry BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON
PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) ELECTRTCAL pERMITTTNG AND TNSPECTTONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL
ROUGH.IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS
REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.
4) ALL DOWNCAST LIGHTING TO BE DOWNCAST AND SHIELDED.
5) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLY WITH WILDFIRE MITIGATION AND
DEFENSIBLE SPACE REOUIREMENTS OF THE COLORADO STATE FOREST SERVICE AND LOCAL FIRE
DISTRICT, SEE GARFIELD COUNTY COMMUNITY DEVELOPMENT DEPARTMENT WEBSITE FOR
FURTHER INFORMATION.
6) OPEN HOLE SOTLS REPORT REOUTRED AT FTRST FOOTING INSPECTTON ,2,s00 PSF SOIL BEARING
CAPACITY.
7) PRE-ENGTNEERED ROOF TRUSSES. HAVE ENGTNEERING FOR BUTLDTNG INSPECTOR AT TIME OF
FRAME INSPECTION.
8) VER|Fy NO CONSTRUCTTON PARKTNG / STAGTNG AREA OVER THE EXTSTTNG SEPTIC TANK AND
LEACH FIELD AREA.
9) COLORADO RTVER ENGTNEERTNG STAMpED LETTER DATED 0s/28/2024 DESCRTBES EXISTING SEPTIC
SYSTEM (SCANNED INTO LASEFICHE FOR PUBLIC RECORD).
10) tSSUEDARCH|TECTURALPLANSFORT44SOFTMASTERSUTTELTVTNGADDITIONABOVETHE
GARAGE - DOES NOT INCLUDE A SECOND KITCHEN NOR FIRE SEPARATION ASSEMBLY FROM THE
MAIN RESIDENCE. NO FUTURE'WET BAR'SHOWN UNDER NEW WORK SCOPE. THIS ADDITION HAS
NOT BEEN REVIEWED AS A FUTURE ADU (ACCESSORY DWELLING UNIT).
1 1) CURRENT ADD|T|ON SCOPE REVTEWED AS A ONE-FAMILY DWELLTNG lN RURAL ZONE DISTRICT.
FUTURE CHANGE TO BUILDING USE OR OCCUPANCY, SHALL BE SUBJECT TO A NEW BUILDING
PERMIT AND LAND USE CHANGE PERMIT IN ACCORDANCE WITH ADOPTED CODES AND LAND USE
REGULATIONS IN EFFECT AT TIME OF FUTURE WORK.
12) CAREFUL: MUST NOT REMOVE VEGETATION FROM 35 FT RIPARIAN ZONE - MEASURES FROM HIGH
WATER MARK.
13) CONDITION OF PERMIT: NO WORK MAY OCCUR lN THE REOUIRED 35-FT MINIMUM SETBACK FROM
THE ryPICAL AND ORDINARY HIGH WATER MARK PER GARFIELD COUNTY'S LAND USE &
DEVELOPMENT CODE, SECTION 7-203. MAPPING & FIELD STAKING OF HIGH WATER MARK SHALL BE
PROVIDED BYA LICENSED SURVEYOR, PROFESSIONAL ENGINEER OR OTHER OUALIFIED
CONSULTANT BEFORE ANY WORK IN THIS AREA IS ALLOWED.
14) GARFIELD COUNry LUDC ARTICLE 7: STANDARDS, DIVISION 2, GENERAL RESOURCE PROTECTION
STANDARDS, E. DITCHES #1 - 9 STAPLED TO PLAN SET FOR PROPERTY OWNER AND GENERAL
CONTRACTOR AWARENESS AND UNDERSTANDING. USE CAUTION WHEN PERFORMING ANY WORK
ADJACENT TO OR NEAR AN IRRIGATION DITCH.
$