HomeMy WebLinkAboutFire Protected Floor Paint Spec SheetNS,EUIrN' ,){r**Fire Protection of Floors lntumescent cooting Estimotlng DESCRIPTION ln residentiol new home construction, the first floor ossembly when fromed with l-joists requires o fire protective or fire-resistont borrier. No-Burn Plus creotes o fire borrier on the substrote, enhoncing fire sofety ond dromoticolly extending the time ovoiloble for residents to exit sofely ond fire responders to extinguish ony flomes. ABOUT US No-Burn intumescent cootings provide the high- performonce, code-compliont fire protection needed in new ond existing residentiol ond commerciol construction ln the presence of extreme heot or fire, intumescent coctings chor ond swell up to multiple times their originol thickness, which shields the substrote ond significontly reduces its rote of combustion. Designed with the professionol in mind, our simple one- coot sproy opplicotion ochieves the code complionce you need with o woter-bosed, low VOC emission formulo, ovoiloble in white ond tinted coloring. Evoluotion Report ER-305 SALES QUOTTNG PROCESS Step #I: Review plons, moke site visit os opplicoble. Determine sq. ft. oreo using exposed froming: l-joists ond subfloor (first floor footprint), determine l-joist height qnd determine l-joist OC spocing. Step #2: Utilize the No-Burn Plus Product Usoge Toble on the next poge. Bosed on l-joist height ond l-joist OC spocing, find the gollons per I sq. ft foctor. Step #3: Determine gollons required by multiplying the totol sq. ft. oreo by the gollons per I sq. ft. foctor, ond figure in o 5% of totol gollons for possible yield vorionce. Exomple#l: . 1,575 sq. ft. . l-joist height 111l8' . l-joist spocing I9.2" oc r Gollons per I sq. ft. foctor.0229 . 1,575 x .0229 = 36.07 Gollons x 1.05 = 37.9 (38) Gollons Exomple#2: . 1,725 sq. ft. . l-joist height 16" . l-joist spocing 16" oc . Gollons per I sq. ft. foctor.0313 t 1,725 x.0313 = 53.99 Gollons x 1.05 = 56.7 (57) Gollons Step #4: Consider 2-person crew productivity os sq. ft. per hour per person. Consider ony odditionol intumescent cooting job proposol foctors. Step #5: Contoct No-Burn, lnc.'s Soles ond/or lnstolled Product Monogement for ossistonce ond morket pricing insights. obtoin No-Burn, lnc. certificotion by completing Instoller Troining. Itlade ln tho USA BEST PRACTICES NS-BuRN.Fire Protection of Floors lntumescent Cooting Estimqting No-Burn Plus Product Usoge Tqble l-joist heiqht t-joist oc spocinq No-Burn Plus wet mils gollons per I sq. ft. gollons per 1250 sq. ft. footprint bosement gollons per 1500 sq. ft. footprint bosement gollons per 1750 sq. ft. footprint bosement gollons per 2000 sq. ft. footprint bosement s112"t6'I5 0.0225 28.r 33.7 39.3 44.9 Loo _o =a ! Co .oo I o o Oo L =a oLF Co s112"19.2'I5 0.0203 25.4 30.4 35.5 40.6 et12'24"l5 0.018t 22,6 27.1 31.7 36.2 |718'l6'l5 0.0256 32.0 38.4 44.8 51.2 117lB"19.2"t5 0.0229 28.6 34.4 40.1 45.8 1r7lS"24"l5 o.0202 25.2 30_3 35.3 44.4 14"l6'I5 4.0284 35.4 42.5 49.6 56.7 14"rs.2'I5 0,0252 31.5 37.8 44.1 50.4 14'24"I5 o.0220 27.5 33.0 38.5 44.0 I6.l6'l5 0.0313 39.r 46.9 54.8 62.6 16"r9.2"I5 0.0276 34.6 4i.5 48.4 55.3 16"24"l5 o.0240 30.0 36.0 42.O 48.0 'r8"16"I5 0.0342 42.8 51.4 5S.9 68.5 lB"19.2"l5 o.030r 37.6 45.1 52.7 60.2 lg"2{t5 0.025s 32.4 38.9 45.4 5r.9 Gode-complidnt solutions. life-soving protection. No-Burn, lnc. SATES INFORMATION AND ORDER PIACEMENT r-800-989-8577 TECHNICAL INFORMATION t-800-989-8577 www.noburn,com TRADEMARKS No-Burn, No-Burn logo ond Fire Wise ore trqdemorks owned by or licensed to No-Burn, Inc. UMITED WARRANTY No-Burn, lnc. worronts thot the No-Burn@ formulo wlll be monufoctured to the some specificotions ond quolity, ond will petform equotly to the tests performed by the independent ldborotories when properly opplied. Worronty coveroge is limited solely to the cost of product purchosed hereunder ond specificolly excludes incidentol expenses ond consequentiol domoges. The opplicotor warronts thot the product, in its originol lorm from the monutocturer, will be stored, mixed ond/or o pplied os directed in the guidelines published by No-Burn, Inc., to every reosonobly occessible qreo thot hos been specified for protection. On occosion, No-Burn Plus moy be opplied to substrotes thot need protected from the environment in tronsit or on o iobsite. The No-Burn Worronty may be void if the No-Burn Plus cooted substrotes, while in transit or during construction, ore not protected from prolonged exposure to odverse weother conditions os specified by monufqcturer recommendotions. All implied worronties, from No-Burn, lnc. or the opplicotor ore excluded. There moy be situotions ond moteriols for which No-Burn will not prevent o fire from igniting or retord the progress of o fire. pOilCy & PROCEDURES AII soles of this product by No-Burn, lnc. ore subiected to our Policy & Procedures ovoiloble ot htto://noburn.com/oolices-orocedures UpDATES AND CURRENT INFORMATION Revised ll-Nov-2021. The informotion in this document moy chonge without notice.O 2021 No-Burn, lnc. ilfade in the USA BEST PRACTICES*tt*t***** ***i*l NS-BU;tN'Plus lntumescent Cooting Wood, Spray Polyurethqne Foom lnsulotion & Drywoll PRODUCT DESCRIPTION No-Burn Plus is on lnternotionol Building, lnternotionol Residentiol, ond Notionol Fire Protection Associotion Life Sofety l0l thin film intumescent cooting. When exposed to high temperotures ond flome, Plus intumesces creoting o chor-borrier protecting treoted substrotes from fire. Monufoctured in complionce with ISO 9001, cs o certified intumescent cooting, Plus is opplied to o voriety of combustible substrotes ochieving the fire performonce prescribed. ABOUT US No-Burn intumescent cootings provide the high- performonce, code-compliont fire protection needed in new ond existing residentiol ond commerciol construction In the presence of extreme heot or fire, intumescent cootings chor ond swell up to multiple times their originol thickness, which shields the substrote ond significontly reduces its rote of combustion. Designed with the professionol in mind, our simple one- coot sproy opplicotion ochieves the code complionce you need with o woter-bosed, low VOC emission formulo, ovoiloble in white ond tinted coloring. PRODUCT SPECI FICATIONS Color: White/Tinted Finish: Flot pH: 7-8 Applicotion: Best Proctices for Applicotion Film Thickness: Reference Code ond Complionce Report Dry Time: 60-90 minutes sofety: Plus sofety Doto sheet (sDs) Overcoot: Woter-bosed with pH of 7-8 VOc content: lB g/L VoC Emissions: CDpH (CR Spec 01350) compliont PACKAGTNO/STOnnes Poils: 5 gollons 0s D, ss tos. Drums: 55 gollon drum (zo8 r), oos tOs. Shelf Life: 24 months in unopened seoled contoiners, properly stored storoge: 4o.F (4"c) - 9oo F (sz.c) Best Proctices for Sofe Hondlino & Storooe PLUS Code-compliqnt solutions. Life-soving protection. White Code Requirement Complionce lnterior Finish FS 0-5 SD 0-35, Closs A: ER-305 surfoce Burning Chorocteristics FRTw Alternotive: TER 20]0-0] Fire Resistonce/ Fire Protection of Floors 2" x1O" Dimension Lumber Equivolent: ER-305 Thermol Borrier Assembly l5 minutes: ER-305 lgnition Borrier Assembly 5* Minutes: ER-305, TER I905-03 Vopor Retorder 5 perms, Closs lll USDA lncidentolFood Contoct ANSI/NSF 5l Food Zone Moteriols No-Buln, lnc. SATES INFORMATION AND ORDER PTACEMENT I-800-989-8577 TECHNICAT INFORMATION t-800-989-8577 www.noburn.com TRADEMARKS No-Burn, No-Burn logo ond Fire Wise ore trodemorks owned by or licensed to No-Burn, lnc. llM|TED WARRANry No-Burn, lnc. wcrronts thot the No-Burno formulo will be monufoctured to the some specificotions ond quolity, ond will perform equolly to the tests performed by the independent loborotories when properly opplied. Worronty coveroge is limited solely to the cost of product purchosed hereunder ond specificolly excludes incidentol expenses ond consequential domoges. The opplicotor worrdnts thot the product, in its originol form from the monufocturer, will be stored, mixed ond/or opplied os directed in the guidelines published by No-Burn, lnc., to every reosonobly occessible oreo thot hos been specified for protection. on occosion, No-Burn Plus moy be opplied to substrotes thot need protected from the environment in tronsit or on o jobsite. The No-Burn Worronty moy be void if the No-Burn Plus cooted substrotes, while in tronsit or during construction, ore not protected from prolonged exposure to odverse weother conditions os specified by monufactursr recommendotions. All implied woronties, from No-Burn, lnc. or the opplicotor ore excluded. There moy be situotions ond moteriols for which No-Burn will not prevent o fire from igniting or retord the progless of o fire. POLICY & PROCEDURES All soles of this product by No-Burn, lnc. ore subjected to our Policy & Procedures ovoiloble ot https://lm.noburn.com/policies-procedures/ UPDATES AND CUnRENT INFORMATION Revised l0-Nov-2021. The informotion in this document moy chonge without notice.@ 2021 No-Burn, lnc. lllade ln tha U$A SUBMITTAL SHEET ffirurc NS-BURN"Plus lntumescent Cooting Wood, sproy Polyurethone Foom lnsulotion & Drywqll Find us in Powered by Deltek Specpoint@ SEC'TION 099646 . IN]UMESCENT PAINTING PART I _ GENERAL l.l SUt\,1MARY A. section lncludes: L lntumescent point for Iinterior] Iond] [exterior] items ond surfoces. B. RelotedRequirements: L section 078123 'lntumescent Fire Protection" for fire- resistonce-roted intumescent mostic mqteriols, 2, sectlon 0ggl13 "Exterior Pointing'for primers qnd finish coots thot moy be used with intumescent point tinishes. 3. Section 099123 'lnterior Pointing" for primers ond finish coots thot moy bo used with intumescent point finishes. 4. Section 099300 'Stoining ond Tronsporent Finishing' for primers, finish coots, ond wood stoins thot moy be used with intumescent point finishes. 5. section 099633 "Hi9h-Temperoture-Resistont cootings" for speciol cootings designed for use on steel subject to extremely high temperotures. I.2 PREINSIAI.LATION NNEETINGS A. Preinstollotion conterence: conduct conference ot IPrcject sitel <lnsert locotion>. ].3 ACTION SUBI,,IITTALS A. Product Dqtq: For eqch type of product. l. Firepropogotionchqrqcteristics. 2. lndicdteVOCcontent. B, sustoinoble Design Submittolsl l. Product Dotq: For points ond cootlngs, indlcoting Voc content. 2. Evoluqtion Reports or cedificqtes: For points ond cootings, indicoting complionce wlth rsquirements for low-emitting moteriols. c. Sqmples: For eoch type of product. D, Somples for lnitiol selection: For eqch type of product. E. Somples for verificotion: For eoch type of cooting system ond eoch colorond gloss of intumescent point finish lndicoted, l. submit sqmples on Irigid bocking] lqctuolsubstrote], not less thon I inches (z0o mm) squore. 2. Apply coqts on Sqmples in steps to show eqch coot requlred for system. 3. Lobel eoch coot of €och SomPle. 4, Lobel eoch somple for locotion ond opplicotion qreo, F. Product Finish Scheduler Use some designotions indicoted on Drowings ond in Port 3 intumescent pointing schedules to cross-reference pqint systems specified in this Section. lnclude color designotions. I.4 INFORMATIONAL SUBMITTATS A. Evoluotion Reports or Listings: For eoch intumescent point qnd cooting, indicoting complionce with fire-propogotion requirements. ].5 MOCKUPS A. Mockups: Apply mockups of eoch point system indicoted to verify preliminqry s€lections mode under somple submittols, to demonstrote oesthetic eftects, ond to set quqlity stondords for moteriqls ond execution. L Architect will select one surfoce to represent surfoces ond conditions toropplicotion of eoch point or cooting system. q. Woll ond ceiling Surtoces; Provide somples of ot leqst lo0 sq, ft. (s sq. m). b. Other ltems; Architect willdesignqte items or qreos required. 2. Flnol opprovol of color selections will be bosod on mockups, o. lf preliminory color selections ore not opproved, qpply qdditionol mockups of qdditionol colors selected by Architect ot no odded cost to Owner. 3. Approvol of mockups does not constitute opprovol of deviotions from the controct Documents contoined in mockups unless Architect specificqlly opproves such deviotions in writing. 4. Subject to complionce with requirementg opproved mockups mqy become port of the completed Work it undisturbed ot time of substontiol complstion. ].6 DEIIVERY, STORAGE, AND HANDLING A. Complywith intumescent point or cooting monufocturer's written instructions for products ond opplicotions os indicqted on product lobels, product doto sheets, qnd opplicotion guidelines. I.7 FIETD CONDITIONS A. Apply woterborne intumescent points only when temperotures of surfoces to be pointed ond ombient oir temperotures ore between 40 ond 90 deg F (4.4 ond 32 deg c). B. Surfoce temperotures of substrotes to not exceed 100 deg r (sr.r oeg c). c. ldeql instqllotion temperoture is 65 deg F (18.3 deg C) qnd less thon 60 percant relotive humidity. D. For continuous high-humidity conditions ot 70 percent or higher, provide exterior woter-bosed lotex top coqt, E. Allow wet surfoces to dry thoroughly ond to ottoin temperoture ond conditions specified belore storting or continuing intumescent pqint opplicotion. PART 2 - PRODUCTS 2.1 MANUFACTURERS A. Bosis-of-Design Product subject to complionce with requirements, provide No-Burn, lnc.; Plus intumescent point. B. PerformonceCriterlo: l. Finish: Flot. 2. color: White. 3. Low-VoC Contenl l8 g/L or less of woter in occordonce with EPA Method 24. 4. solids byVolume: 60-70 percent. 2.2 INTUMESCENT PAINT PRODUCTS, GENERAL A. Comply with requirements for fire-protective intumescent cootlng clossificotion ond surfoce-burning chorocteristics indicoted. B. Surfoce-Burning Chorocteristics - l0-Minute Tunnel Test: As tested in occordonce with ASTN,I E84; testing by o quolified testing ogency, ldentify products with oppropriote morkings of opplicoble testing qgency. l. Flome-Spreod lndex25orless. 2. smoke-Developed lndex 450 or less. c. surfoce-Burning chorocteristics for Wood - 30-Minute Tunnel Test: As tested in occordonce with ASTM E84 or ASTM E2768; testing by o quollfled testlng og€ncy. ldentily products with oppropriote morkings of opplicoble testing ogency. l. Flome Front Moximum Reoch: lo ft. (3.048 m). 2. Evldence of Continued Combustion: None, when test continued for 30 minutes. 3. Clossificotion: Fire Retordont Treoted Wood (FRTw) equivolent ond complies with definition of on ignition- resistont moteriol- D. Fire Resistqnce:Complies with ASTM Ellg lqs qn equivqlent to 2-by-tO-inch (ooo-oy-sooo mm) dimension lumberl; testing by o quolified testing ogency. ldentity products with oppropriote morkings of opplicoble opprovql ogency. E. Thermol Borrier Cooting: Complies with NFPA 286, FM 4880, ut 1040, or UL 1715. ldentily products with qppropriote morkings ot opplicoble qpprovol ogency. F. lgnition Boilier Cooting: Complies wlth ICC-ES AC37Z Appendix x. ldentify products with oppropriote morkings of opplicoble opprovol ogency. G. Moteriql Compqtibilit\I l. For eoch moteriol or opplicotion, provide products recommended in writing by intumescent point monufocturer for use on substrote indicoted. H. voc content: For field opplicotions Ithot ore inside the weotherproofing systeml, points ond cootings to comply with Voc content limits of outhorities hqving jurisdiction qnd the followlng VoC content Iimits: l. Flot Points ond cootings:50 g/1,. J. tow-Emitting Moteriols: lnt€rior pqints ond cootlngs to comply with the testing ond product requirements of the colifornio Deportment of Public H€olth's'stqndord Method for th€ Testing ond Evoluotion of Volotile orgonlc Chemicql Emissions from Indoor sources Using Environmentol chombers." K. Moteriql Emissions ond Pollutont Control: Field-qpplied points ond coqtings thot ore inside the weotherprooling system to comply with either of the following: L tow-Emitting Moteriqls: VOC emissions to comply with the requirements of the Coliforniq Deportment of Public Heolth's "Stondord Method for the Testing ond Evoluotion of Volotile orgonic ch€micol Emissions from Indoor Sources Using Environmentol Chqmbers." Formqldehyde emissions to not excesd 9 mcg/cu. m or 7 ppb, whichever is less. 2. vOC content to not exc€ed limits ot outhorities hqving jurisdiction ond the following; o. Flotcootings: 50 g/t. L. EmissionsRequirements:Field-oppliedpqintsond cootlngs thot ore inside the weotherproofing system to comply with either of the following: l. Low-Emitting Moteriols: Voc emissions to comply with th€ requir€m€nts of the Colitornio Deportment of Public Heolth's'stondord Method for the Testing ond Evoluotion of Volotile orgonic chemicol Emissions from lndoor Sources Using Environmentol Chqmbers." 2. Voc content to not exceed llmits ot outhorities hoving jurisdiction ond the following: q. FlqtCootings: 50 g/1. M. VOC Content: For field opplicotlons inslde the building, woll points to complywith voc content limits of outhorities hoving jurisdiction ond the following VOc content limits: l. lnterior Flot Lotex Woll Pointr 50 g/1. N, Voc Emissions:Forfield opplicotions inside the building, woll points to contoin no more thon holf of the chronic REL , of VOCS when tested in occordonce with the Colifornio Deportment of Publlc Heqlth's'stondord Method for the Testing ond lvoluotion of Volotlle orgqnic chemicol Emissions from lndoor Sources Using Environmentol chombers.'The building concentrotion of formqldehyde to not exceed holf of the indoor recommend€d exposure limit or 33 mcg/cu. m ond thot of ocetqldehyde to not exceed I mcg/cu. m. o. Colors ond sheen; white, flot IAs selected by Architect from monufocturer's lull ronge] [as indicoted in o color schedule]. 2.3 MISCETLANEOUS N'ATERIATS A. Topcoot 6- to 8-mil- (0.15- to 0.20-mm) thick lwoter bosed lotex-bosed point] Iexterior topcootl recommended in writing by intumesc€nt point monufocturer qs compotlble wlth substrqte moterlols. l. Bqsis-of-Design Exterior Topcoot: subject to complionce with requirements, provide Behr Premium Plus Exterior Pqint or comporoble product, 2. Decorotive Topcoot Woter-bosed lotex-bosed point for interior conditioned spoces recommended in writing by intumescent point mqnufocturer os compotible with substrote moteriols. 3. Protective Topcoot, lnterior or Exterior: VOC-compliont topcoot, for interior or exterior unconditioned spoces subject to constont high humidity, condensotion, or direct contoct with moisture. PARI 3 . EXECUTION 3-] EXAMINATION A. Exqmine substrqtes ond conditions, tor complionce with monufocturer's requirements for surtoce treotments, shop-primed surfoc6s, moximum moisture contont, ond other conditions otfecting performonce of the Work. 3,2 PREPARATION A. Comply with mqnufocturer's written instructions opplicoble to substrotes ond coqting systems indicoted, B. Remove hordwore ond hordwore occessories, plotes, mochined surfoc€s,light fixtures, ond similor items olreody instolled thot ore not to be cooted. lf removql is improcticqlor impossible becouse of size or weight of item, provide surfoce-opplied protection before surfoce preporotlon ond cooting. MasterSpec' lllade ln the U$A rere - SUBMITTAL SHEET NS'BUR,N"Plus lntumescent Cooting Wood, sproy Polyurethone Foom lnsulotion & Drywoll l. After completlng cooting qppllcotion, uso workers skilled in the trodes involved to reinstoll items thot were removed. Remove surfoce-opplied protection if ony. C. Cleon substrotes of substonces thot could impqir bond of cootings, including dust, dirt, oil, greqse, ond incompotible points ond encqpsulqnts- Do not coot surfoces if surfqce moisture content or olkolinity exceeds thot permitted in monufoctureis written instructions. l. Remove incompotible primers, ond reprime substrote with compotible prlmers os required to produce cooting systems indicoted. 2. Pertorm cleqning ond cooting opplicotion so dust ond other contominonts from cleoning process do not foll on wet newly cooted surtoces. 3.3 INSTATLATION A. Apply intumescent points in occordonce with monufocturer's written instructions ond to comply with requirements for evoluotions, listings, ond lobels. L Use equlpment ond techniques best suited for substrote ond type of moteriol being opplled. B. Apply cootings to prepored surfoces os soon os procticol qfter preporotion. c. Apply cootings to produce surfoce films without holidoys, lops. sogs, or other surfoce impertections. Produce shorp lines. 3.4CtEANING AND PROTECTION A. Protect work ot other trodes from cooting oPplicotion. corrsct domoge to work of other trodes by cleoning, repoiring, replocing, ond refinishing, os qpproved by Architect, ond leove in on undqmoged condition. B. At completion of construction octivities of other trodes, touch up ond restore dqmoged or defqced cooted surtoces. 3.5 EXTERIOR INTUI,IESCENT PAINTING SCHEDULE A. Wood substrotes, solid Sqwn Lumber ond Sheothing: l. Surfoce-Burning chorocteristics: o. lntumescent Point As recommended in writing by monufqcturer. l) No-Burn,lnc.:No-BurnPlus. b. Topcoot (optionol): Exterior, select sheen. l) Behr: Behr Premium Plus Exterior Point. B. Wood substrqtes, Engineered wood Lumber ond sheothing: L surfoce-Burning Choroct€ristics: o. lntumescent Poinl As recommended ln writing by monufocturer. l) No-Burn,lnc.:No-BurnPlus. b. Topcoot (optionql): Exterlor, select sheen. I) Behr: Behr Premium Plus Ext€rior Point, 3.6 INTERIOR INTUMESCENT PAINTING SCHEDULE A. Wood substrotes, Solld Sown Lumber ond sheothing: l. Surfoce-Burning chorocteristics: o, lntumescent Pqlnt; As recommend€d in writing by monufqcturer, l) No-Burn,lnc.:No-BurnPlus. B. Wood Substrotes, Enginsered Wood tumb€r ond Sheothing: l. surtoce-Burning chorocteristics: q. lntumescent PointlAs recomm€nded in writing by monufocturer. l) No-Burn,lnc.:No-BurnPlus. c. wood Substrotes, l-Joist: l. Fire Resistonce Assembly As on equivqlent to 2-by-10- inch (6oo-by-3ooo mm) dimension lumber: o. lntumescent Point: As recommended in writing by monufqcturel. l) No-Burn,lnc.:No-BurnPlus. D. Structurol hsuloted Ponels: l. Thermol Borrier Assembly, lnterior Finish: q. Intumescent Point: As recommend€d in writing by monufocturer. l) No-Burn, lnc.: No-Burn Plus. E, Sproy Polyurethone Foom, closed-Cell Sproy Polyurethone Foqm: L lgnition Borrier Assembly,lnterior Finish: o. lntumescent Point: As r€commended in writing by monufocturer, l) No-Burn,lnc.:No-BurnPIus. F. sproy Polyurethone Foqm, Open-cell sproy Polyurethone Foom: l. lgnitlon Borrier Assembly, lnterior Finish: o. lntumescent Point As recommended in writing by monufocturer. 1) No-Burn,lnc.: No-Burn Plus. END OF SECTTON 099646 Yrelllade ln thc U$A SUBMITTAL SHEET