HomeMy WebLinkAboutFire Protected Floor Paint Spec SheetNS,EUIrN' ,){r**Fire Protection of Floors
lntumescent cooting
Estimotlng
DESCRIPTION
ln residentiol new home construction, the first floor
ossembly when fromed with l-joists requires o fire
protective or fire-resistont borrier. No-Burn Plus creotes o
fire borrier on the substrote, enhoncing fire sofety ond
dromoticolly extending the time ovoiloble for residents to
exit sofely ond fire responders to extinguish ony flomes.
ABOUT US
No-Burn intumescent cootings provide the high-
performonce, code-compliont fire protection needed in
new ond existing residentiol ond commerciol construction
ln the presence of extreme heot or fire, intumescent
coctings chor ond swell up to multiple times their originol
thickness, which shields the substrote ond significontly
reduces its rote of combustion.
Designed with the professionol in mind, our simple one-
coot sproy opplicotion ochieves the code complionce you
need with o woter-bosed, low VOC emission formulo,
ovoiloble in white ond tinted coloring.
Evoluotion Report
ER-305
SALES QUOTTNG PROCESS
Step #I: Review plons, moke site visit os opplicoble. Determine sq. ft. oreo using exposed froming: l-joists ond subfloor (first
floor footprint), determine l-joist height qnd determine l-joist OC spocing.
Step #2: Utilize the No-Burn Plus Product Usoge Toble on the next poge. Bosed on l-joist height ond l-joist OC spocing, find
the gollons per I sq. ft foctor.
Step #3: Determine gollons required by multiplying the totol sq. ft. oreo by the gollons per I sq. ft. foctor, ond figure in o 5% of
totol gollons for possible yield vorionce.
Exomple#l:
. 1,575 sq. ft.
. l-joist height 111l8'
. l-joist spocing I9.2" oc
r Gollons per I sq. ft. foctor.0229
. 1,575 x .0229 = 36.07 Gollons x 1.05 = 37.9 (38) Gollons
Exomple#2:
. 1,725 sq. ft.
. l-joist height 16"
. l-joist spocing 16" oc
. Gollons per I sq. ft. foctor.0313
t 1,725 x.0313 = 53.99 Gollons x 1.05 = 56.7 (57) Gollons
Step #4: Consider 2-person crew productivity os sq. ft. per hour per person. Consider ony odditionol intumescent cooting job
proposol foctors.
Step #5: Contoct No-Burn, lnc.'s Soles ond/or lnstolled Product Monogement for ossistonce ond morket pricing insights.
obtoin No-Burn, lnc. certificotion by completing Instoller Troining.
Itlade ln tho USA BEST PRACTICES
NS-BuRN.Fire Protection of Floors
lntumescent Cooting
Estimqting
No-Burn Plus Product Usoge Tqble
l-joist
heiqht
t-joist oc
spocinq
No-Burn Plus
wet mils
gollons per
I sq. ft.
gollons per
1250 sq. ft.
footprint
bosement
gollons per
1500 sq. ft.
footprint
bosement
gollons per
1750 sq. ft.
footprint
bosement
gollons per
2000 sq. ft.
footprint
bosement
s112"t6'I5 0.0225 28.r 33.7 39.3 44.9
Loo
_o
=a
!
Co
.oo
I
o
o
Oo
L
=a
oLF
Co
s112"19.2'I5 0.0203 25.4 30.4 35.5 40.6
et12'24"l5 0.018t 22,6 27.1 31.7 36.2
|718'l6'l5 0.0256 32.0 38.4 44.8 51.2
117lB"19.2"t5 0.0229 28.6 34.4 40.1 45.8
1r7lS"24"l5 o.0202 25.2 30_3 35.3 44.4
14"l6'I5 4.0284 35.4 42.5 49.6 56.7
14"rs.2'I5 0,0252 31.5 37.8 44.1 50.4
14'24"I5 o.0220 27.5 33.0 38.5 44.0
I6.l6'l5 0.0313 39.r 46.9 54.8 62.6
16"r9.2"I5 0.0276 34.6 4i.5 48.4 55.3
16"24"l5 o.0240 30.0 36.0 42.O 48.0
'r8"16"I5 0.0342 42.8 51.4 5S.9 68.5
lB"19.2"l5 o.030r 37.6 45.1 52.7 60.2
lg"2{t5 0.025s 32.4 38.9 45.4 5r.9
Gode-complidnt solutions. life-soving protection.
No-Burn, lnc.
SATES INFORMATION AND ORDER PIACEMENT
r-800-989-8577
TECHNICAL INFORMATION
t-800-989-8577
www.noburn,com
TRADEMARKS No-Burn, No-Burn logo ond Fire Wise ore trqdemorks owned by or licensed to No-Burn, Inc.
UMITED WARRANTY No-Burn, lnc. worronts thot the No-Burn@ formulo wlll be monufoctured to the some specificotions ond quolity,
ond will petform equotly to the tests performed by the independent ldborotories when properly opplied. Worronty coveroge is
limited solely to the cost of product purchosed hereunder ond specificolly excludes incidentol expenses ond consequentiol
domoges. The opplicotor warronts thot the product, in its originol lorm from the monutocturer, will be stored, mixed ond/or o pplied
os directed in the guidelines published by No-Burn, Inc., to every reosonobly occessible qreo thot hos been specified for protection.
On occosion, No-Burn Plus moy be opplied to substrotes thot need protected from the environment in tronsit or on o iobsite. The
No-Burn Worronty may be void if the No-Burn Plus cooted substrotes, while in transit or during construction, ore not protected from
prolonged exposure to odverse weother conditions os specified by monufqcturer recommendotions. All implied worronties, from
No-Burn, lnc. or the opplicotor ore excluded. There moy be situotions ond moteriols for which No-Burn will not prevent o fire from
igniting or retord the progress of o fire.
pOilCy & PROCEDURES AII soles of this product by No-Burn, lnc. ore subiected to our Policy & Procedures ovoiloble ot
htto://noburn.com/oolices-orocedures
UpDATES AND CURRENT INFORMATION Revised ll-Nov-2021. The informotion in this document moy chonge without notice.O 2021 No-Burn, lnc.
ilfade in the USA BEST PRACTICES*tt*t*****
***i*l
NS-BU;tN'Plus
lntumescent Cooting
Wood, Spray Polyurethqne Foom lnsulotion & Drywoll
PRODUCT DESCRIPTION
No-Burn Plus is on lnternotionol Building, lnternotionol
Residentiol, ond Notionol Fire Protection Associotion Life
Sofety l0l thin film intumescent cooting. When exposed to
high temperotures ond flome, Plus intumesces creoting o
chor-borrier protecting treoted substrotes from fire.
Monufoctured in complionce with ISO 9001, cs o certified
intumescent cooting, Plus is opplied to o voriety of
combustible substrotes ochieving the fire performonce
prescribed.
ABOUT US
No-Burn intumescent cootings provide the high-
performonce, code-compliont fire protection needed in
new ond existing residentiol ond commerciol construction
In the presence of extreme heot or fire, intumescent
cootings chor ond swell up to multiple times their originol
thickness, which shields the substrote ond significontly
reduces its rote of combustion.
Designed with the professionol in mind, our simple one-
coot sproy opplicotion ochieves the code complionce you
need with o woter-bosed, low VOC emission formulo,
ovoiloble in white ond tinted coloring.
PRODUCT SPECI FICATIONS
Color: White/Tinted
Finish: Flot
pH: 7-8
Applicotion: Best Proctices for Applicotion
Film Thickness: Reference Code ond Complionce Report
Dry Time: 60-90 minutes
sofety: Plus sofety Doto sheet (sDs)
Overcoot: Woter-bosed with pH of 7-8
VOc content: lB g/L
VoC Emissions: CDpH (CR Spec 01350) compliont
PACKAGTNO/STOnnes
Poils: 5 gollons 0s D, ss tos.
Drums: 55 gollon drum (zo8 r), oos tOs.
Shelf Life: 24 months in unopened seoled contoiners,
properly stored
storoge: 4o.F (4"c) - 9oo F (sz.c)
Best Proctices for Sofe Hondlino & Storooe
PLUS
Code-compliqnt solutions. Life-soving protection.
White
Code Requirement Complionce
lnterior Finish FS 0-5 SD 0-35, Closs A: ER-305
surfoce Burning
Chorocteristics FRTw Alternotive: TER 20]0-0]
Fire Resistonce/
Fire Protection of Floors
2" x1O" Dimension Lumber
Equivolent: ER-305
Thermol Borrier Assembly l5 minutes: ER-305
lgnition Borrier Assembly 5* Minutes: ER-305, TER I905-03
Vopor Retorder 5 perms, Closs lll
USDA lncidentolFood
Contoct
ANSI/NSF 5l Food Zone
Moteriols
No-Buln, lnc.
SATES INFORMATION AND ORDER PTACEMENT
I-800-989-8577
TECHNICAT INFORMATION
t-800-989-8577
www.noburn.com
TRADEMARKS No-Burn, No-Burn logo ond Fire Wise ore trodemorks owned by or licensed to No-Burn, lnc.
llM|TED WARRANry No-Burn, lnc. wcrronts thot the No-Burno formulo will be monufoctured to the some specificotions ond quolity, ond will
perform equolly to the tests performed by the independent loborotories when properly opplied. Worronty coveroge is limited solely to the cost
of product purchosed hereunder ond specificolly excludes incidentol expenses ond consequential domoges. The opplicotor worrdnts thot the
product, in its originol form from the monufocturer, will be stored, mixed ond/or opplied os directed in the guidelines published by No-Burn,
lnc., to every reosonobly occessible oreo thot hos been specified for protection. on occosion, No-Burn Plus moy be opplied to substrotes thot
need protected from the environment in tronsit or on o jobsite. The No-Burn Worronty moy be void if the No-Burn Plus cooted substrotes, while
in tronsit or during construction, ore not protected from prolonged exposure to odverse weother conditions os specified by monufactursr
recommendotions. All implied woronties, from No-Burn, lnc. or the opplicotor ore excluded. There moy be situotions ond moteriols for which
No-Burn will not prevent o fire from igniting or retord the progless of o fire.
POLICY & PROCEDURES All soles of this product by No-Burn, lnc. ore subjected to our Policy & Procedures ovoiloble ot
https://lm.noburn.com/policies-procedures/
UPDATES AND CUnRENT INFORMATION Revised l0-Nov-2021. The informotion in this document moy chonge without notice.@ 2021 No-Burn, lnc.
lllade ln tha U$A SUBMITTAL SHEET
ffirurc
NS-BURN"Plus
lntumescent Cooting
Wood, sproy Polyurethone Foom lnsulotion & Drywqll
Find us in
Powered by Deltek Specpoint@
SEC'TION 099646 . IN]UMESCENT PAINTING
PART I _ GENERAL
l.l SUt\,1MARY
A. section lncludes:
L lntumescent point for Iinterior] Iond] [exterior] items
ond surfoces.
B. RelotedRequirements:
L section 078123 'lntumescent Fire Protection" for fire-
resistonce-roted intumescent mostic mqteriols,
2, sectlon 0ggl13 "Exterior Pointing'for primers qnd finish
coots thot moy be used with intumescent point
tinishes.
3. Section 099123 'lnterior Pointing" for primers ond finish
coots thot moy bo used with intumescent point
finishes.
4. Section 099300 'Stoining ond Tronsporent Finishing' for
primers, finish coots, ond wood stoins thot moy be
used with intumescent point finishes.
5. section 099633 "Hi9h-Temperoture-Resistont cootings"
for speciol cootings designed for use on steel subject
to extremely high temperotures.
I.2 PREINSIAI.LATION NNEETINGS
A. Preinstollotion conterence: conduct conference ot IPrcject
sitel <lnsert locotion>.
].3 ACTION SUBI,,IITTALS
A. Product Dqtq: For eqch type of product.
l. Firepropogotionchqrqcteristics.
2. lndicdteVOCcontent.
B, sustoinoble Design Submittolsl
l. Product Dotq: For points ond cootlngs, indlcoting Voc
content.
2. Evoluqtion Reports or cedificqtes: For points ond
cootings, indicoting complionce wlth rsquirements for
low-emitting moteriols.
c. Sqmples: For eoch type of product.
D, Somples for lnitiol selection: For eqch type of product.
E. Somples for verificotion: For eoch type of cooting system
ond eoch colorond gloss of intumescent point finish
lndicoted,
l. submit sqmples on Irigid bocking] lqctuolsubstrote],
not less thon I inches (z0o mm) squore.
2. Apply coqts on Sqmples in steps to show eqch coot
requlred for system.
3. Lobel eoch coot of €och SomPle.
4, Lobel eoch somple for locotion ond opplicotion qreo,
F. Product Finish Scheduler Use some designotions indicoted
on Drowings ond in Port 3 intumescent pointing schedules
to cross-reference pqint systems specified in this Section.
lnclude color designotions.
I.4 INFORMATIONAL SUBMITTATS
A. Evoluotion Reports or Listings: For eoch intumescent point
qnd cooting, indicoting complionce with fire-propogotion
requirements.
].5 MOCKUPS
A. Mockups: Apply mockups of eoch point system indicoted
to verify preliminqry s€lections mode under somple
submittols, to demonstrote oesthetic eftects, ond to set
quqlity stondords for moteriqls ond execution.
L Architect will select one surfoce to represent surfoces
ond conditions toropplicotion of eoch point or cooting
system.
q. Woll ond ceiling Surtoces; Provide somples of ot
leqst lo0 sq, ft. (s sq. m).
b. Other ltems; Architect willdesignqte items or qreos
required.
2. Flnol opprovol of color selections will be bosod on
mockups,
o. lf preliminory color selections ore not opproved,
qpply qdditionol mockups of qdditionol colors
selected by Architect ot no odded cost to Owner.
3. Approvol of mockups does not constitute opprovol of
deviotions from the controct Documents contoined in
mockups unless Architect specificqlly opproves such
deviotions in writing.
4. Subject to complionce with requirementg opproved
mockups mqy become port of the completed Work it
undisturbed ot time of substontiol complstion.
].6 DEIIVERY, STORAGE, AND HANDLING
A. Complywith intumescent point or cooting monufocturer's
written instructions for products ond opplicotions os
indicqted on product lobels, product doto sheets, qnd
opplicotion guidelines.
I.7 FIETD CONDITIONS
A. Apply woterborne intumescent points only when
temperotures of surfoces to be pointed ond ombient oir
temperotures ore between 40 ond 90 deg F (4.4 ond 32
deg c).
B. Surfoce temperotures of substrotes to not exceed 100 deg
r (sr.r oeg c).
c. ldeql instqllotion temperoture is 65 deg F (18.3 deg C) qnd
less thon 60 percant relotive humidity.
D. For continuous high-humidity conditions ot 70 percent or
higher, provide exterior woter-bosed lotex top coqt,
E. Allow wet surfoces to dry thoroughly ond to ottoin
temperoture ond conditions specified belore storting or
continuing intumescent pqint opplicotion.
PART 2 - PRODUCTS
2.1 MANUFACTURERS
A. Bosis-of-Design Product subject to complionce with
requirements, provide No-Burn, lnc.; Plus intumescent
point.
B. PerformonceCriterlo:
l. Finish: Flot.
2. color: White.
3. Low-VoC Contenl l8 g/L or less of woter in occordonce
with EPA Method 24.
4. solids byVolume: 60-70 percent.
2.2 INTUMESCENT PAINT PRODUCTS, GENERAL
A. Comply with requirements for fire-protective intumescent
cootlng clossificotion ond surfoce-burning chorocteristics
indicoted.
B. Surfoce-Burning Chorocteristics - l0-Minute Tunnel Test:
As tested in occordonce with ASTN,I E84; testing by o
quolified testing ogency, ldentify products with
oppropriote morkings of opplicoble testing qgency.
l. Flome-Spreod lndex25orless.
2. smoke-Developed lndex 450 or less.
c. surfoce-Burning chorocteristics for Wood - 30-Minute
Tunnel Test: As tested in occordonce with ASTM E84 or
ASTM E2768; testing by o quollfled testlng og€ncy. ldentily
products with oppropriote morkings of opplicoble testing
ogency.
l. Flome Front Moximum Reoch: lo ft. (3.048 m).
2. Evldence of Continued Combustion: None, when test
continued for 30 minutes.
3. Clossificotion: Fire Retordont Treoted Wood (FRTw)
equivolent ond complies with definition of on ignition-
resistont moteriol-
D. Fire Resistqnce:Complies with ASTM Ellg lqs qn equivqlent
to 2-by-tO-inch (ooo-oy-sooo mm) dimension lumberl;
testing by o quolified testing ogency. ldentity products
with oppropriote morkings of opplicoble opprovql ogency.
E. Thermol Borrier Cooting: Complies with NFPA 286, FM 4880,
ut 1040, or UL 1715. ldentily products with qppropriote
morkings ot opplicoble qpprovol ogency.
F. lgnition Boilier Cooting: Complies wlth ICC-ES AC37Z
Appendix x. ldentify products with oppropriote morkings of
opplicoble opprovol ogency.
G. Moteriql Compqtibilit\I
l. For eoch moteriol or opplicotion, provide products
recommended in writing by intumescent point
monufocturer for use on substrote indicoted.
H. voc content: For field opplicotions Ithot ore inside the
weotherproofing systeml, points ond cootings to comply
with Voc content limits of outhorities hqving jurisdiction
qnd the followlng VoC content Iimits:
l. Flot Points ond cootings:50 g/1,.
J. tow-Emitting Moteriols: lnt€rior pqints ond cootlngs to
comply with the testing ond product requirements of the
colifornio Deportment of Public H€olth's'stqndord Method
for th€ Testing ond Evoluotion of Volotile orgonlc Chemicql
Emissions from Indoor sources Using Environmentol
chombers."
K. Moteriql Emissions ond Pollutont Control: Field-qpplied
points ond coqtings thot ore inside the weotherprooling
system to comply with either of the following:
L tow-Emitting Moteriqls: VOC emissions to comply with
the requirements of the Coliforniq Deportment of Public
Heolth's "Stondord Method for the Testing ond
Evoluotion of Volotile orgonic ch€micol Emissions from
Indoor Sources Using Environmentol Chqmbers."
Formqldehyde emissions to not excesd 9 mcg/cu. m or
7 ppb, whichever is less.
2. vOC content to not exc€ed limits ot outhorities hqving
jurisdiction ond the following;
o. Flotcootings: 50 g/t.
L. EmissionsRequirements:Field-oppliedpqintsond
cootlngs thot ore inside the weotherproofing system to
comply with either of the following:
l. Low-Emitting Moteriols: Voc emissions to comply with
th€ requir€m€nts of the Colitornio Deportment of Public
Heolth's'stondord Method for the Testing ond
Evoluotion of Volotile orgonic chemicol Emissions from
lndoor Sources Using Environmentol Chqmbers."
2. Voc content to not exceed llmits ot outhorities hoving
jurisdiction ond the following:
q. FlqtCootings: 50 g/1.
M. VOC Content: For field opplicotlons inslde the building, woll
points to complywith voc content limits of outhorities
hoving jurisdiction ond the following VOc content limits:
l. lnterior Flot Lotex Woll Pointr 50 g/1.
N, Voc Emissions:Forfield opplicotions inside the building,
woll points to contoin no more thon holf of the chronic REL
, of VOCS when tested in occordonce with the Colifornio
Deportment of Publlc Heqlth's'stondord Method for the
Testing ond lvoluotion of Volotlle orgqnic chemicol
Emissions from lndoor Sources Using Environmentol
chombers.'The building concentrotion of formqldehyde to
not exceed holf of the indoor recommend€d exposure limit
or 33 mcg/cu. m ond thot of ocetqldehyde to not exceed I
mcg/cu. m.
o. Colors ond sheen; white, flot IAs selected by Architect
from monufocturer's lull ronge] [as indicoted in o color
schedule].
2.3 MISCETLANEOUS N'ATERIATS
A. Topcoot 6- to 8-mil- (0.15- to 0.20-mm) thick lwoter
bosed lotex-bosed point] Iexterior topcootl
recommended in writing by intumesc€nt point
monufocturer qs compotlble wlth substrqte moterlols.
l. Bqsis-of-Design Exterior Topcoot: subject to
complionce with requirements, provide Behr Premium
Plus Exterior Pqint or comporoble product,
2. Decorotive Topcoot Woter-bosed lotex-bosed point
for interior conditioned spoces recommended in
writing by intumescent point mqnufocturer os
compotible with substrote moteriols.
3. Protective Topcoot, lnterior or Exterior: VOC-compliont
topcoot, for interior or exterior unconditioned spoces
subject to constont high humidity, condensotion, or
direct contoct with moisture.
PARI 3 . EXECUTION
3-] EXAMINATION
A. Exqmine substrqtes ond conditions, tor complionce with
monufocturer's requirements for surtoce treotments,
shop-primed surfoc6s, moximum moisture contont, ond
other conditions otfecting performonce of the Work.
3,2 PREPARATION
A. Comply with mqnufocturer's written instructions
opplicoble to substrotes ond coqting systems indicoted,
B. Remove hordwore ond hordwore occessories, plotes,
mochined surfoc€s,light fixtures, ond similor items olreody
instolled thot ore not to be cooted. lf removql is
improcticqlor impossible becouse of size or weight of
item, provide surfoce-opplied protection before surfoce
preporotlon ond cooting.
MasterSpec'
lllade ln the U$A rere
-
SUBMITTAL SHEET
NS'BUR,N"Plus
lntumescent Cooting
Wood, sproy Polyurethone Foom lnsulotion & Drywoll
l. After completlng cooting qppllcotion, uso workers
skilled in the trodes involved to reinstoll items thot were
removed. Remove surfoce-opplied protection if ony.
C. Cleon substrotes of substonces thot could impqir bond of
cootings, including dust, dirt, oil, greqse, ond incompotible
points ond encqpsulqnts- Do not coot surfoces if surfqce
moisture content or olkolinity exceeds thot permitted in
monufoctureis written instructions.
l. Remove incompotible primers, ond reprime substrote
with compotible prlmers os required to produce
cooting systems indicoted.
2. Pertorm cleqning ond cooting opplicotion so dust ond
other contominonts from cleoning process do not foll
on wet newly cooted surtoces.
3.3 INSTATLATION
A. Apply intumescent points in occordonce with
monufocturer's written instructions ond to comply with
requirements for evoluotions, listings, ond lobels.
L Use equlpment ond techniques best suited for
substrote ond type of moteriol being opplled.
B. Apply cootings to prepored surfoces os soon os procticol
qfter preporotion.
c. Apply cootings to produce surfoce films without holidoys,
lops. sogs, or other surfoce impertections. Produce shorp
lines.
3.4CtEANING AND PROTECTION
A. Protect work ot other trodes from cooting oPplicotion.
corrsct domoge to work of other trodes by cleoning,
repoiring, replocing, ond refinishing, os qpproved by
Architect, ond leove in on undqmoged condition.
B. At completion of construction octivities of other trodes,
touch up ond restore dqmoged or defqced cooted
surtoces.
3.5 EXTERIOR INTUI,IESCENT PAINTING SCHEDULE
A. Wood substrotes, solid Sqwn Lumber ond Sheothing:
l. Surfoce-Burning chorocteristics:
o. lntumescent Point As recommended in writing by
monufqcturer.
l) No-Burn,lnc.:No-BurnPlus.
b. Topcoot (optionol): Exterior, select sheen.
l) Behr: Behr Premium Plus Exterior Point.
B. Wood substrqtes, Engineered wood Lumber ond
sheothing:
L surfoce-Burning Choroct€ristics:
o. lntumescent Poinl As recommended ln writing by
monufocturer.
l) No-Burn,lnc.:No-BurnPlus.
b. Topcoot (optionql): Exterlor, select sheen.
I) Behr: Behr Premium Plus Ext€rior Point,
3.6 INTERIOR INTUMESCENT PAINTING SCHEDULE
A. Wood substrotes, Solld Sown Lumber ond sheothing:
l. Surfoce-Burning chorocteristics:
o, lntumescent Pqlnt; As recommend€d in writing by
monufqcturer,
l) No-Burn,lnc.:No-BurnPlus.
B. Wood Substrotes, Enginsered Wood tumb€r ond
Sheothing:
l. surtoce-Burning chorocteristics:
q. lntumescent PointlAs recomm€nded in writing by
monufocturer.
l) No-Burn,lnc.:No-BurnPlus.
c. wood Substrotes, l-Joist:
l. Fire Resistonce Assembly As on equivqlent to 2-by-10-
inch (6oo-by-3ooo mm) dimension lumber:
o. lntumescent Point: As recommended in writing by
monufqcturel.
l) No-Burn,lnc.:No-BurnPlus.
D. Structurol hsuloted Ponels:
l. Thermol Borrier Assembly, lnterior Finish:
q. Intumescent Point: As recommend€d in writing by
monufocturer.
l) No-Burn, lnc.: No-Burn Plus.
E, Sproy Polyurethone Foom, closed-Cell Sproy Polyurethone
Foqm:
L lgnition Borrier Assembly,lnterior Finish:
o. lntumescent Point: As r€commended in writing by
monufocturer,
l) No-Burn,lnc.:No-BurnPIus.
F. sproy Polyurethone Foqm, Open-cell sproy Polyurethone
Foom:
l. lgnitlon Borrier Assembly, lnterior Finish:
o. lntumescent Point As recommended in writing by
monufocturer.
1) No-Burn,lnc.: No-Burn Plus.
END OF SECTTON 099646
Yrelllade ln thc U$A SUBMITTAL SHEET