HomeMy WebLinkAboutPermit Card
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 5970 County Road 109, Carbondale_ Parcel No.: 239328318001
Owner Name: Todd Christman Owner Phone: (415) 260-4165
Designed By: CBO, Inc. Designer Phone: (970) 309-5259
Contractor: The Home Group Inc. Contractor Phone: (970) 319-7378
Number of Bedrooms: _4_ Minimum Tank Capacity: 1,250-gallon Minimum Absorption: 656.25 ft2
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT-8817_______________________________
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date _08/01/2024____________________ Expiration Date_08/01/2025_________________
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the report and design as
submitted by CBO, Inc. dated July 20, 2024. Changes to the design and permit must be approved by
Garfield County Public Health and the designer prior to construction.
The new OWTS will serve a new four-bedroom residence. The system will consist of a new, two-
compartment 1,500-gallon septic tank set level with access to grade followed by a 500-gallon pump
chamber set level with access to grade and a high-head pump in the pump chamber. Effluent will be
pumped to an automatic distributing valve set at the high point of the system that will distribute
effluent to 656.5 ft2 of STA. The new STA will consist of a 13 feet wide by 50.5 feet long unlined sand
filter bed consisting of 3-feet of secondary sand media. The sand filter will have two zones of two
laterals per zone. Distribution laterals are to be 1 ½ inch Schedule 40 PVC, with 5/32-inch orifices 3-
feet on center and the laterals ending in flushing valves at the distal end of the laterals. The
distribution laterals shall be placed in GeoMat distribution material with the orifices facing
downward. Inspection ports are to be installed at each corner of the bed. Maintain all setbacks and
elevations as designed.
To assist in scheduling, please contact Garfield County Public Health (970-945-6614 ext. 8150) to notify
the start of OWTS construction. Contact the designer and Garfield County Public Health at least 48 hours
prior to requesting final inspection of the installed system prior to backfill. NO OWTS COMPONENT SHALL
BE BACKFILLED WITHOUT PRIOR APPROVAL FROM GARFIELD COUNTY PUBLIC HEALTH AND THE
DESIGNER.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction, and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection,
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as-built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
08/01/2024
Issued By: Garfield County Environmental Health
Department
Date