Loading...
HomeMy WebLinkAboutPlans,4' WESTERN SLOPE ROOFING (/,zo F UxIlI o ITJt-oz o Fr F{Ucl ca o rT(J2 ts{ |.JA EoU rgooU &orr CI rq 3rflH FIfr * I d ^d\}/ J 7 rt Ld v T ,1 t-l d d Ho2o caz FJ& EIorrlhaAIt{ Fr -lohi:r. FrE F2oht FrUr{A C',zFIo2 !n rl:Nt !t'\ €b trllr ci Fzt{: }|F Ftao(J aFllrltlhil I qzo F.U U rg o GRAND VALTEYFIRE PROTECTION DISCTRICT WESTERN SLOPE ROOFING INC 10287 HIGHWAY 65 MESA CO 81643 PO BOX 290 MESA CO 81643 WESTERNSLOPEROOFI NG@GMAI L.COM 974-697-7s42 We are removing the exisiting rubber EPDM, and old insulation and reinstalling Fully adhered TPO Membrane. We are doing decks D,E,G,|,J,K, and L EFEtrtI NIFEIIEI!t Eig!EI !tI TFEL -tEti Fil trll !t lfi EE SF ES EE EILa-Ll- trt --TE> -t-E TELEI Heat lffelded TPO MernbranE Fasteners Fully Adlured Steel RoofDeck Bonding Adhesive lnsulatipn GTHERMOPLASTIC MEMBRANES NOTES: RhinoBond METHOD 0F MEMBRANE ATTACHMENT IS NOT FOR USE WTH NON_FACED EPS (EXPANDED POLYSTYRENE) OR XPS (EXTRUDED POLYSTYRENE) INSULATIONS. 2. PERIMETER ENHANCEMENTS REQUIRED FOR V/IND SPEED COVERAGE GREATER THAN 72MPH. CONTACT VIRSICO FOR REQUIREMENTS. 3. ENHANCEMENT SHOWN ARE FOR THE PURPOSE OF THE VTRSICO WARRANTY. FOR FM PROJECTS CONSULT FM GLOBAL FOR REQUIRED ENHANCEMENTS. 8'-0" RhinoBondl RAISED ROOF EDGE OR PARAPET WALL SEE B DIMENSI SEE A FOR IMENSIONS 4'-0"4'-0"4'-0"8'-0" MlN. MEMBRANE FASTENED MINIMUM 12" O.C. AT CHANGES. FOR ADDITIONAL INFORMATION SEE DETAIL B&_2 Ldz.oZN>E - l-rj?h @e td o_ Ld E. oJ LrJtr l!oo E. +N .F:l 12" 24" 24" 24"2" PERIMETER ZONE 8 FASTENERS PER 4'X8' BOARD g'-0" 4 +N 18"30"50" v- FIELD 6 FASTENERS PER 4'X8' BOARD L-- l PERTMETER AREA FIELD AREA 4 DETAIL RB_2 FEET TO CEN1IMETERS FEET 1 4 8' cm 30 122 244 :l 4'-0" @ VERSICO FASTENER &o RhinoBond FASTTNER PLATE INCHES TO CENTIMETERS inch 2"5.5"4"12"18"24"30" cm 5 9 10 30 46 61 76 DECK TYPE DECK THICKNESS FASTENER THERMOPLASTIC COATED PLATE STEEL 22 GAUGI (0.8mm)VERSICO HPVX FAS]ENER 3-1l8" (8cm) DIAMETER PLYWOOD 15/32" (12mm) NOTE: AT IN-FILL MINOR PIECES, USE MlN. 2 FASTENERS. VERSICO RhinoBond RB-1 vVE O2o2J rrERslco ROOFING S RhinoBond ATTACHMENT METHOD-NUMBER OF FASTENERS AND LOCATION MATERIAL LIST TPO MATERIALS ' VERSICO TPO PS 6OML ' VERSICO HPV FASTENER . Applicable to steel, 22-gauge and heavier, CDX plywood and wood plank deck types' Can be used to secure VersiGard reinforced membranes, RTS and for insulation securement. Longer fastener sizes available as special order. Not applicable for securing TPO and PVC membranes. ' INSULATION FASTENING PLATE . Applicable with lnsultite, HPV and CD-10 fasteners. Used for insulation securement only on steel, wood and concrete decks. Available in steel or plastic. t TERMINATION BAR (ALUMINUM) r Extruded aluminum bar that is designed for securing and sealing compression type flashing terminations. The bar features a top edge for ease of applying Versico's Lap Sealant for EPDM installations or Universal Single Ply Sealant for TPO and PVC installations. The bar can be easily cut to any desired length' ' TERM BAR NAIL-IN . Used with Versico's Termination Bar or Seam Fastening Plates to secure membrane to concrete block, brick, or structural concrete walls. A zinc-plated steel pin provides excellent corrosion resistance while the zinc alloy body provides excellent holding power. + HPVXPLATE . Along with the appropriate fastener, used to secure VersiWeld and VersiFlex membranes to steel, concrete and wood decks. ' VERSIWELD TPO BONDING ADHESIVE . A high-strength, solvent-based contact adhesive that allows bonding of VersiWeld membrane to various porous and non-porous substrates. .> VERSICORE POLYISO r A rigid roof insulation panel composed of a closed-cell polyisocyanurate foam core bonded to glass-reinforced felt (GRF) facers. UL and FM approved for direct applications over steel decks, polyiso provides the highest R-value per inch of any commercially available insulation Product. ' NON REINFORCED FLASHING . 12" x 50' - Product Number: 300479 - Gray ' TPO PRIMER . Designed for one-step priming of EPDM and TPO surfaces prior to the application of pressure-sensitive products. lt is a Low-VOC product that is ideal for use where environmental issues are a concern. . Coverage Rate: As high as 700 square feet per gallon with TPO or Clean (No Dust) EPDM membrane. Approx. 250 square feet per gallon with dusted EPDM membrane. ' TPO PIPE BOOTS r lnjection-molded, pre-formed pipe flashings for pipes "/o" to 8" diameter. Molded Pipe Seals provide a reliable method of waterproofing round pipe penetrations, as well as a substantial labor savings compared to field fabrication' ' COATED METAL 4'X1O'PRODUCT NUMBER 309273 \ i-fr/{, \-* Fqsteners & Plotes rV, VETS|GOTd EPDM av, versiweld TPo evt VerstFlex PVC Applicoble for insulotion ollochmenl in both mechonicolly foslened ond lully odhered opplicotions Sizes Avoiloble: 2- - B" ('I" lncrements) 1%,2',3'- 8" (1" lncrements) Size & Quonlity Per Box: 2"- B": ,I,000 Applicoble for concrele decks. Used 1o secure VersiGord, VersiWeld 0nd VersiFlex membrqnes ond {or insulolion securement, Sizes Avoiloble: 2' - 5Yz' (/2" lncremenls) 6" - l2' ('l" lnctemenis) Size & Quontiiy Pet Box: 2" - B": 500; 9"- 12": 250 A #14 diomeler fostener used for VersiGord reinforced, VersiWeld ond VersiFlex membrone securemenl inlo slructurol concrele decks (minimum 3,000psi) Also opplicoble to insulotion securemeni inlo sleel, wood ond concrete decks. Sizes Avoilqble: lYa', 13/a',2' - '14" (1" lncremenls) Size & ouonfity Pet Box:'l7+" - 4": 'l,000; 5" - I l": 500; 12" 14":250 A pre-ossembled #.l2 diomeler fostener ond ploslic insulolion plole opplicoble lo steel ond wood decks. Used lo secure insuloiion only. Longer fostener sizes ovoiloble 0s speciol order. Sizes Avoiloble: 2Vt',3'- B" (1" lncremenls) Size & Quontily Per Box: 21/+" - B", 250 iv, HPVX Fqslener & HPV-XL Foslener HPV Fostener ev,iv,rvt Retrodriller iv,rv,rv, Purlin Fqslener iv,.v, Applicoble to steel, 22-g0uge ond heovier, CDX plywood ond wood plonk deck lypes. Con be used to secure VersiGord reinforced membronet RTS ond for insulolion securemeni. Longer foslener sizes ovoiloble 0s speciol order, Nol opplicoble for securing TPO ond PVC membrones. Sizes Avoiloble: 1Y4',2'- 15" ('l" lncrements) Size & Quontity Per Box: lVa',2'- 6": 1,000; 500; -l3" - 'l5": 250; l7a";1000 A #15 diomeler foslener opplicoble lo sleel, wood ond CDX plywood, Con be used lo secure VersiGord, VersiWeld ond VersiFlex membrones Sizes Avoiloble: 2' - 12' (1' lncremenls) l4'- 16" (2" lncrements) Size & Quonlity Per Box: 2" - 4": 1,000; 5" - 'l2" 500; .l4"- 16": 250 A #21 diometer fostener opplicoble lo sleel, wood ond CDX plywood decks, Sizes Avoiloble: 2" - B" (l' increments) Size & Suontity Per Box; 500 (2'- 6"), 250 (7" - B") A speciolly designed foslener with o t/2" drill poinl used for otloching VersiGord, VersiWeld ond VersiFlex membrones 1o slructurol sleel purlins (up to %0") in slonding seum metol r00f retrofit opplicolions. Sizes Avoiloble: 4: 5: 6',, B" & 10" Size & Suonlily Per Box; 500 Used wiih Versico's Meiol Retrofil Roofing System l0 secure membrone ond RTS 1o slluclur0l steel purlins Compolible with 2" Polymer Ploles. Provides superior bock-out resislonce in stondord 16-gouge Purlins Siz€s Avoildble: 3s/a,, 43/a" 53/q',7" B" Suonfity Per Box:],000 lnsuliite rv,.v,.v, cD-to rv, ev, MP I4.IO rvtrv,rv, iv,ev,rvt rvt lnsultile ASAP wilh Polymer Plqle 8 Fosteners & Plqtes fV, Versicord EPDM av, Versiweld TPo ivt VersiFlex PVC HPVX ASAP HPV ASAP rV, A pre-ossembled HPVX Foslenel ond HPVX Plole opplicoble lo steel, wood ond CDX plywood decks. Used lo secure VersiWeld ond VersiFlex membrones. Sizes Avoiloble; 2'- B" (l' lncremenls) 'l0" - 14" (2" lncremenls) Size & Ouonlify PeI Box: 2"- B":250; 10" - 'I2": 200; 14": ]50 Pre-ossembled HPV Foslener ond Polymer seom plote opplicoble to sleel, wood ond CDX plywood decks. Used lo secure VersiGord reinforced membrones. sizes Avoiloble: 2' - 12' (1' lncrements) Size & ouontity Per Box: 2":5OA;3":450; 4', 5": 400; 6": 350; 7', 8": 300; 9": 250; 10" - 12": 200 .v, Gyptec Fqslener & Plole ev, rv, Polymer Seqm Plote .vt lnduclion Welding Plqte .Vr rV, Seqm Foslening Plqle rv, rv,rV, lnsulolion Foslening PIqte rfU, Applicoble to cemenlilious wood fiber, lighlweight concrele ond gypsum decks. Con be used to secure VersiGord reinforced, Versiweld ond VersiFlex membrones ond insulotion, Sizes Avoiloble: 2Y2'- l0' (t/2" lncremenis) Size & Quontity Per Box: 2t/2" -7"..500; 71/t" - 10":250 r'::y g,r'f ;r": i tltl ltr Sizes Avoiloble: 2" Melol membrone Plote 3" Melol insulotion plole ouontity Per Box: ],000 3"-round, speciolly co0ted ploies used with HPVX Fosleners ond the RhinoBond induction welding system. Avoiloble in TPo ond PVC versions. Sizes Avoiloble: 3" dio, Producl Number: 325630 - TPO Producl Numberi 325640 - PVC Product Number: 325910 - TPO isoweld@ Product Number: 32946\ - PVC isoweld Quoniily Per Box: 500 rv, -{ Duql Prong Bqse Sheet Foslener .Vr.Vtiv, Used in conjunciion wiih HPV Fosteners. Required for EPDM membr0ne ond RTS ottochment for mechonicolly otl0ched roOfing systems over steel decks Sizes Avoiloble: 2" dio. Suqntity Pet Box: 1,000 :li.Y. i ; ,,i'.'t:r;i:1,: .rr,iiir rll J* Also Availoble (Nol shown) For use wilh HPV-XL Fosiener to secure VersiGord reinforced membrone lo steel decks, sizes Avoiloble: 2%" dio. Ouontity PeI Box: 1,000 A 2" diometer melol plole, opplicoble wilh HPV MP l4-]0 ond CD-]0 fosleners, used for insulolion otlochmenl on MF Sysiems or membrone securemeni ot ongle chonges on Adhered Syslems in conjunclion wilh the oppropriote Versico fostener. sizes Avqiloble: 2" dio, ouonlity Pet Box: 1,000 ii:" I' ,:t#s Designed lo secure bose sheets over gypsum, fibrous cemenl ond lighiweighl concrele decks Fosleners ore inslolled using Versico's stond-up Duol Prong Applicotor, which holds ond drives lhe lube inio the deck ond sels lhe wires, Sizes Avoiloble: 1.8" ouontity Per Box: 500 Applicoble wilh lnsultite, HPV ond CD-]0 fosleners. Used for insulolion securemenl only on sieel, wood ond concrete decks. Avoiloble in steel or plostic Sizes Avoiloble: 3" dio, 0uontity Per Box: ,l,000 9 tor Wices rcfer to lhe ptice tisl. Fot a complele inventory of Versico's Fastenerc & Ptates, rcfer to lhe Fasteners ond Ploles Brcchurc' Fqsteners & Plqtes Terminqtion Bqr (Aluminum) IV, VeTsicord EPDM tVt Versiwelo TPO rlvl VersiFiex PVc Extruded oluminum bor thol is designed for securing 0nd seoling compression type floshing terminotions. The bor feolures 0 top edge for eose of opplying Versico's Lop Seolonl for EPDM inslollolions or Universol Single Ply Seolonl for TPO ond PVC inslollolions, The bor con be e0sily cut lo ony desired lenglh. Sizes Avsiloble: l" wide x l0' long ouontity Per Box: 50 pcs; 500 Lineor Feel Used wiih Versico's Terminotion Bor or Seom Fostening Ploles lo secure membrone lo concrele block, brick, or slructurol concrele wolls. A zinc-ploied sieel pin provides excellent corrosion resistonce while lhe zinc olloy body provides excellent holding power. Sizes Avoiloble: lVq' Quonlily Per Box r,000 Golv0lume'.-cooled metol b0r used lo mechonicolly olioch EPDM membrones, The bor con be eosily cui to desired lenglh, lnslolled using HPV Fosleners. Sizes Avoiloble: I " wide x l0' long ouontily Per Box: 50 pcs; 500 Lineor Feel An engineered polymer bor lhol is used to mechonicolly oltoch EPDM membrones, The b0r hos pre-punched holes every 3" on cenler. The strip con be eosily cut lo ony desired length. lnsioll the skip using HPV or HPVX Fosleners Sizes Avoiloble: l" x 250' coil Suontity Per Box: 250' per corlon Ovsl Bqrbed Plqle tla Use with oll VersiFlex PVC polyester- reinforced membrones. These ploles ore designed lo mechonicolly oltoch VersiFlex PVC membrQne to metoL wood ond concrete decks, Sizes Avoiloble llz' X 23/q' ouontily Per Box 500 iv,.vt.v, Term Bqr Noil-ln iv,rv,.v, Metql Foslening Bor pl aalrv, Polymer Bqlten Strip 'r.{Ft rv, t t Sizes Avoiloble: .l Suontily Per Box 1,000rv, rI7,rv, SecurFqsl'" lnsuloiion Fqsiening Plote AccuTr<rc Plqte (lnsulolion) av,iv,rv, HPVX Plole .v,rvt AccuTroc Ploies ore 3" squore flot 0r recessed- boltom ploles mode of Golvolume-cooted steel, Used io foslen insulotion wilh lhe AccuTroc Tool Designed for SECUROCK@ securemenl under VersiGord, VersiWeld, or VersiFlex roofing sysiems. Ploles ore slomped from Golvolume-cooted sleel for long. lerm prolection ogoinsl corrosion. Sizes Avoiloble: ,)1/"il Suqntity Per Box: r,000 Along with lhe oppropriole fostener, used lo secure Versiweld ond VersiFlex membrones to sleel, concrete ond wood decks, Sizes Avoiloble: 2%" dio. ouontity Per Box: .|,000 Also Availoble (Not shown) For use wilh HPV-XL Foslener 1o secure VersiWeld ond VersiFlex membrones to sleel ond wood decks. Sizes Avoiloble: 2%" dio. ouontity Per Box: ],000 iv, l0 Adhesives & Seolsnts VersiWeld TPO Bonding Adhesive tVt VersiGord EPDM alz, versiFleece fV, versiWeld TPO iV, versiFleece Ac rV, versiFlex PVc aV, Low-VoC Producl A high-slrength, solvenl-b0sed conloct odhesive thol ollows bonding of VersiWeld membrone lo vorious porous ond non-porous substrotes. Coveroge Rote: 60 squore feet per g0llon o{ finished surfoce. Pockoging: 5-gol poil Product Numbel:3O2323 Shelt Life: l2 months G2OOSA Subslrole Adhesive rV, EPDM x-23 Low-VOC Bonding Adhesive* A high-slrength, solvenl-bosed conlocl 0dhesive thol ollows quick bonding of cured EPDM membrones io vorious subslroies. Designed for bonding VersiGord (block ond white) non- reinforced ond VersiGord reinforced membrones lo opproved subslroJe, Coverqge Rote: 60 squore feet per gollon of finished surfoce. Pockoging: 5-gol poil Product NumbsI: 302'141 Shelf Life; l2 monlhs A high-slrenglh, solveni-bosed contocl odh0sive thot bonds EPDM membrones 1o vorious porous ond non-porous subslroles, This produci meets lhe <250 gpl VOC content requiremenls of ihe OTC Model Rule for Single-Ply Roo{ing Adhesives, Coveroge Roie: 60 squore feel per gollon of finished surfoce. Pockoging: 5-gol poil Product Number:324002 Shelf Life: l2 monihs A high-strenglh, solveni-bosed conlocl odhesive thot ollows bonding of oll EPDM ond TPO membrone to vorious porous ond non-porous subslroles. Low-VOC Bonding Adhesive meets lhe <250 gpl VOC contenl requiremenls oflhe OTC Model Rule for Single-Ply Roofing Adhesives. Low-VOC Bonding Adhesive l l68 meets ihe requiremenls for SCAOMD regulotions, Coveroge Rote: 60 squore feef per gollon of finished sur{oce. Pockoging: 5-gol poil Produci Number: 303090 - Low-VOC Bonding Product Number:318847 - Low-VOC Bonding ll68 Shell Life: l2 monihs rv, Low-VOC PVC Bonding Adhesive t't 1-\ Low-VOC PVC Slep I Aclivolor A high-strength, solvenf-bosed conlocl odhesive lhot ollows bonding of PVC ond KEE HP membrone to vorious porous ond non-porous substroles. Meels the <250 gpl VOC conlenl requiremenls of the OTC Model Rule for Single-Ply roofing odhesives. Coveroge Rote: 60 squ0re feet per gollon finished surfoce. Pockoging: 5-gol poil Product Numbel: 309'l26 Shelf Life: l2 monlhs A high-slrenglh, solventb0sled oclivolor thol 0llows PVC Pressure-Sensitive Cover Slrip to be bonded to PVC or KEE HP membrones. Meels lhe <250 gpl VOC contenl requiremenis of the OTC Model Rule, Coveroge Rote: As high os 250 - 300 squore feel per gollon. Pockoging: (2) l-gollon cons Product Numhel: 33265.l Shelf Life: l2 months --r8T"tott lfi.w t6la lEaroa rv, ev, .fzt . Nol Compliont in oll CA counties rv, rvt tvt* rv, Low-VOC Bonding Adhesive & Low-VOC Bonding Adhesive lI68 rv, Low-VOC PVC Slep 2 Primer A high-solids-conienL cleor Polymer-bosed primer used to prepore KEE HP ond PVC membrone lo be bonded lo PVC Pressure Sensilive Cover Strip. Meels the <250 gpl VOC contenl requiremenls of the OTC Model Rule. Coverqge Rote: As high os 700 squore feei per gollon. Pockoging: (2) l-gollon cons Product Number:332652 Shelf l-ife: 6 monlhs n lnsulotion VersiOore@ Polyiso A rigid roof insulolion ponel composed of o closed-cell polyisocyonurole fo0m core bonded to gloss-reinforced felt (GRF) focers, UL ond FM opproved for direcl opplicolions over steel decks, polyiso provides the highesl R-volue per inch of ony commerciolly ovoiloble insulolion producl, Sizes:4'x 4'ond 4'x B' Thickness: t/r" lo 4Y2" Compressive Sltength: 20 ond 25psi A rigid roof insulotion ponel composed of o 1l'' high- densily, closed-cell polyisocyonur0le fo0m c0re bonded to o premium performonce cooted gloss focer (CGF), ReodyFlosh Technology is o slondord feolure of SecurShield HD Polyiso, ReodyFlosh feolures o dork focer on one side of lhe insulolion boord ond c lighl focer on the olher. Utilizing the sun's energy, the dork focer occeleroles odhesive flosh-off while the light focer slows il down. Specificolly designed for use 0s 0 cover boord. Provides 5 times lhe R-volue 0l 5 times less weighl lhon lrodiiionol gypsum cover boords. /z" ochieves UL Clqss A Fire Roling over combustible decks, Sizes: 4' x 4' ond 4'x B' Thickness: Y2" Compressive Strenglh: 20psi (SecurShield b0se lcyer) ond l09psi mox (SecurShield HD cover boord) Securshield HD ncauvi"'";7"! SecurShield HD Plus VersiOore HD A rigid-roof insulolion cover b00rd composed of o high-density closed-cell polyisocyonurole foom core bonded to gloss-reinforced felt (GRF) focers, Versi0ore HD is speci{icolly designed for use 0s 0 cover boord in mechonicolly-ottoched systems only. Sizes:4'x 4'ond 4'x 8' Thickness: /2" Compressive Slrength: B0psi A rigid roof insulolion ponel composed of o t/2" high-densily, closed-cell polyisocyonurole foom core bonded lo o premium-performonce cooled gl0ss focer (CGF). Specificolly designed for use os o cover boord. Provides on FM l-90 wind uplifi roting wilh only B fosleners per 4' x B' boord. Sizes:4'x 4'ond 4'x B' Thickness: Y2" Compressive Stlength: 109psi mox SecurShield@ E'^.L A rigid roof insulotion ponel composed of o closed cell polyisocyonurote foom core bonded to high performonce cooled gloss focers (CGF). ReodyFlosh Technology is 0 siondord feolure of SecurShield Polyiso, ReodyFlosh feotures o d0rk focer on one side of lhe insulolion boord ond o light focer on lhe olher. Ulilizing the sun's energy, the d0rk focer 0cceleroles odhesive flosh-off while the light focer slows il down, l" boord ochieves UL Closs A Fire Roling over combustible decks, lde0l for use in odhered membrone systems, Sizes: 4'x 4'ond 4'x B' Thickness: 1/t" lo 4lz" Compressive Sftenglh: 20 ond 25psi SecurShield HD ComPosite A unique composite insulolion p0nel comprised of o r/2" high-densily polyiso cover boord bonded during ihe monufocluring process to SecurShield rigid polyiso roof insulolion, Eliminoles the need ior 0 seporote cover bor:rd, reduces lhe inler-ply odhesives ond soves lobor on the roof. Sizes:4' x 4'ond 4'x B' Thickness: lt/2" lo 4r/2" Compressive Strength: 20psi (SecurShield b0se loyer) ond 109psi mox (SecurShield HD cover boord) 2t rV, VERSIvVELE) TPo iV, vERsFLEx P\tc Non-Reinlorced Floshing G \J Non-reinforced thermoplostic membrone used lo Jield{obricote pipe floshings, ond scuppers when the use of o pre-molded occessory is not feosible. PVC Sizes Avqiloble: 60-mil.l2" x 50' - Pfoduct Number: 327840 - White/Groy 'l2" x 50' - Product Number: 327842 - WhilelTon 24" x 50'- Producl Number: 327841 - WhiteiGroy 24" x 50' - Producl Numberr 327843 - While/Ton 24" x 50'- Product Number: 334437 - Ll Groy 24" x 50' - Producl Number: 335821 - Slote Groy Quontity PeI Box: I roll TPO Sizes Avoilohle: 60-mil 12" x 50'- Producl Numberi 300473 - Whiie 'l2" x 50'- Producf Number: 300479 - Groy 'l2" x 50'- Producl Numberr 300476 - Ton 24" x 50' - Product Number: 300474 - While 24" x 50' - Product Number: 300480 - Groy 24" x50'- Product Number: 300477 -Ton 24" x 50'- Producl Number: 332963 - Medium Bronze 24" x 50' - Produci Numberi 328050 - Polino Green 24" x 50' - Producl Number: 328056 - Rock Brown 24" x 5O' - Producl Number: 328053 - Slote Groy 24" x 50'- Product Numberi 328047 -Terro Cotlo 0uontily Per Box: I roll TPO Pressure-Sensilive Cover strip Reinforced Floshing Non-reinforced TPO lominoled to pressure-sensilive lope used for stripping in flol metol flonges such os shop-benl drip edge, Sizes Avoiloble: 6" x ]00' - Producl Number: 303102 - White 6" x 100' - Produci Number: 303103 - Groy 6" x ]00' - Producl Number: 303]04 - Ton ouontity Per Box: 2 rolls Pre-slil reinforced membrone used to overloy fosleners, plotes, ond end lops on VersiFleece ond VersiWeld@ QA membrones. Sizes Avoiloble: 45-mil 6" x 100' - Product Number: 300485 - While 6" x 'l00'- Producl Number: 300480 - Groy 6" x ]00' * Producl Number: 302Bll - Ton 60-mil 6" x ,l00' - Producl Number: 325005 - While 6" x 100' - Product Numberr 325003 - Groy 6" x ]00'- Producl Number: 325004 *Tqn 9" x 50' - Producl Number: 3]0419 - White 9" x 50' - Producl Number: 310417 - Groy 9" x 50' - Producl Number: 3]04]8 - Ton 80-mil 9" x 50'- Product Number; 318404 - While Quontity Per Box: 3 rolls (6"), 2 rolls (9") PVC Pressule-Sensitive Gover Slrip l Yellow PS Worning StriP Non-reinforced KEE HP floshing lominoled to 0 nominol 35-mil, fully cured, pressure-sensilive, synthetic rubber for use on PVC/KEE HP utilizing Step I Activotor ond Slep 2 Primer for instollqlion, Sizes Avoiloble: 6" x ]00' - Producl Number: 332616 - White 6" x 'l00' - Producl Number: 332617 - Groy 6" x '100' - Producl Numberr 332618 - Ton Ouonliiy Per Box: 2 rolls TPO Pressure-Sensitive RUSS l0' RUSS (shown) is used in pl0ce of norrow-widlh sheels 1o secure membrone in lhe perimeter of the roof on mechonicolly ottoched syslems, 6" RUSS is olso ovqiloble ond is used lo secure membrone 0t lhe bqse ol verticol wolls for odditionol membrone securement wilhoui penelloling the sheel. Sizes Avoiloble: 6" x ,l00'- Producl Number: 303373 l0" x 100'- Product Number: 305442 Qugntity Per Box: I roll (10"), 2 rolls (6") Non-reinforced yellow TPO coverslrip con be used on TPO EPDM, or PVC wilh the corresponding membrone primer (ond ocfivotor for PVC) to indicole roof edges ond olher hozords, Sizes Avqiloble: 6" x '100'- Producl Number: 325721 ouqntily Per Box: 2 rolls 3 Adhesives & Seslonts tl7, versiGord EPDM rvt VersiFleece fV, Versiweld TPo ilZ VersiFleece Ac flz, VersiFlex PVC aV, Low-VoC Product Designed for one-slep priming of EPDM ond TPO surfoces prior to lhe 0pplicolion of pressure- sensitive products. ll is o Low-VOC product thot is ideol for use where environmenlol issuss ore o concern, Coveroge Rofe; As high os 700 squore feel per gollon with TPO or Cleon (No Dust) FPDM membrone. Approx, 250 squore feel per gollon wilh dusled EPDM membrqne. Pockoging: (6) l-gol cons Product Number: 329'l6'l Shelf Life: l2 monlhs This cleoner is speciolly formuloled to cleon bolh new ond in-service VersiFlex PVC ond VersiFlex KEE HP membrones. Pqckoging: 5-gol closed-lop poil Product Number:329729 V-I50 EPDM Primer rv, TPO Primer . Not Compliont in oll CA counlies Low-VOC EPDM ond TPO Primer A solvenl-bosed producl designed for cleoning 0nd priming EPDM membrones prior to the opplicolion of QA products. Coveroge Role: As high os 450 squore feel per gollon with cleon EPDM membrone. Approx. 250 squore feet per gollon with stondord membrone. Pockoging: (6) l-gol cons Producl Number: 30208.l Pockoging: 3-gollon poils Product Number: 332684 Shelf Life: l2 monlhs A high-solids, cleor polymer-bosed primer used lo prepore TPO membrone prior io lhe opplicotion of TP0 pressure-sensilive producls. Coversge Rote: 200 - 250 squore feet (one surfoce) per gollon. Pockoging: (6) 1-gol cons Product Numher: 3,l0471 Shelf life: l2 monlhs unopened con Used to cleon bolh new ond in-service VersiGord EPDM membrone ond VersiWeld TPO membrqne prior to lhe welding process. lt helps lo loosen ond remove diri ond other coniominonls from the surf0ce of lhe membrones ond leoves o suiioble surfoce for opplicoiion of odhesive or primer. Pleose refer lo the Techniccl Doto Bullelins for specilic inslruclions for EPDM ond TPO opplicolions. Membrone cleoner is cleor in color. Cover0ge Role: 400 squore feel (one surfoce) per gollon, Pockoging: (2) 1-gol closedJop cons, 5-gol closedjop poil l-gql cqns Product Number: 304066 5-gol poil Producl Number:302074 iir T qr ivt rl7,rv, PVC AND KEE HP MEMBRANE CTEANER rvt Weolhered Membrqne Cleoner .v,rv, Low-VOC Membrone Cleqnel GOR ASE ON ALL MEMBRANES) rv,rv, avt* Use to cleon both new ond in-service, PVC, KEE HP, TPO, ond EPDM membrones prior lo the seoming process. Low-VOC Membrone Cle0ner conloins 100% EPA-exempled solvents ond con be used in o wide voriely of lemperotures, Pockoging; (2) l-gol cons & s-gollon closed-top poil l-gol cons Product Numbel:326160 5-gol poil Product Number:326860 .V, ilz, iV, rvt tq t5 rV, VERSIv\IELED Tpo iV, VERSIFLE)< Pvc Molded Pipe Seols lnjection-m0lded, pre-formed pipe floshings for pipes 3/" to B" diomeier. Molded Pipe Seols provide o relioble method of woierproofing round pipe peneirglions, os well os 0 subslonliol lobor sovings compored t0 field fobricotion. TpO PVC Sizes Avoiloble: Sizes Avoiloble: s/+"- B" dio. - Product Number: 316534 - While 3/a" - B" dio, - Product Number: 316537 - While 3/a"- B" dio. - Producl Number: 316535 - Groy 3/a" - B" dio. - Produci Number: 322959 - Groy 3/+'- 8" dio. - Produci Number: 316536 - Ton 3/a" - B" dio. - Produci Number: 323823 Ton guontiry per B'x: B t/0" - B" dio. producr Number; 348093 - Light Groy Suontity Per Box: B Curb Wrop Corners Molded Seolqnl Pockels l-l F0bricoted floshings m0de of Versiweld detoil membrone ond VersiFlex membrone designed to reduce curb floshing lime. Eoch corner hos o 6"-wide bose ilonge ond 0 .12" over0ll height. One curb will require 4 corners. Olher sizes ond colors ovoiloble lhrough speciol orders. C0n 0lso be ordered in l- or 2-piece wrops, PVC Sizes Avoiloble: 7" Wrop for l2" Curb - Producl Number: 322973 - White Product Number'. 322970 - GroY Produci Number: 322977 - Ton I3" Wrop lor 24" Curb - Producl Number: 322975 - Whife Producl Number: 322971 - Groy Producl Number, 322978 -Ion l9" Wrop for 36" Curb - Producl Number: 322976 - White Producl Number: 322972 - Gtoy Producl Number: 322979 - Ion Suontily Per Box: 12 pieces or 3 complele curbs lnlerlocking, lwo-piece injection-molded ond weldoble pockeis used io wolerproof pipe cluslers or olher oddly shoped penekotions. TPO Sizes Avoiloble: 7" Wrop for 12" curb - Product Number: 305062 - White Producl Number; 307674 - Groy Producl Number: 307668 - Ton l3" Wrop for 24" CuIb - Producl Number: 305063 - White Producl Number: 307675 - Groy Product Number: 307669 - Ton 19" Wrop for 36" Curb - Producl Number: 305064 - White Produci Number: 307676 - Groy Producl Number: 307670 - Ton Quontity Per Box: 12 pieces or 3 complele curbs Rib Profile TPO Sizes Avoiloble: 6" wide x 2" high Con be odjusted IromTYz" Io 11Y2" in lenglh Product Number: 3]6539 - While Producl Number: 316540 - Groy Producl Number; 31654] - Ton Quontity Per Box: 5 complete pockels PVC Sizes Avoiloble: 6"wide x 2" high Con be odjusted IromTVz" Io 111/2" in lengih Product Number: 3]6542 * While Ouontity Per Box: 5 complete pockets 1 This profile is exlruded from the some weolher-resistontTPO or PVC compound os the membrone. The Rib Profile is secured to lhe TPO or PVC roofing membrone to simulote o stonding seom metol roofing system. The physicol dimension0l stobility o{ the profile is enh0nced with fibergloss 0nd the reclongulor profile provides exceptionol shodow lines for oeslhelic oppeol, TpO PVC Sizes Avoiloble: l0'- Producf Number: 324574 .whiIe l0' - Producl Number: 324572 - Groy l0'- Producl Number: 324573 - Ton l0'- Product Number: 333064 - Medium Bronze 10'- Producl Number: 330830 - Rock Brown l0'- Producl Number: 330797 Terro Collo l0' - Producl Number: 330799 - Slote Groy l0' - Producl Number: 330798 - Potino Green Quontify Pet Box: 20 Sizes Avoilable: l0'- Producl Number: 32.l909 - White l0'- Producl Number; 321911 - Groy l0' - Product Number: 32]9]0 - Ton l0'- Product Number: 334439 - Lt Groy l0'- Producl Number: 335823 - Slole Groy ouonlity PeI Box: 20 5 rvr vERStvtTELED Tpo rVt vERsFLE)< pvc Cooted Metol 24-g0uge (0.6 mm) golvonized sleel sheel lhol is cooled wilh o loyer of .035" non-reinforced floshing, Membrone moy be welded direclly lo the cooted meiol, The sheei is cut to the oppropriote width ond used 1o fobricote met0l drip edges or olher roof perimeter sdging profiles. TPO PVC sizes Avoiloble: Sizes Avoiloble: I 0 Pcs/Pollet - 4' x l0' - Producl Number: 307708 - White 4' x 10'- Producl Number: 307709 - Groy 4' x l0'- Product Number: 307710 - Ton 4' x l0'- Producl Number: 334438 - Lt. Groy 4' x l0'- Product Number: 335822 - Slole Groy l0 Pcs/Pollet - 4' x l0'- Produci Number: 309272 - While 4' x l0' - Producl Number: 309273 - Groy 4' x l0' - Producl Number: 309274 - Ton 5 Pcs/Pollel - 4' x 10'- Product Number:332912 - Poiino Green 4'x l0'- Producl Number: 332913 - Rock Brown 4' x l0'- Producl Number: 332914 - Slole Groy 4' x l0'- Producl Number: 332915 - Terrq Cotto 4'x l0'- Producl Number: 332916 - Medium Bronze 25 Pcs/Pollst - 4' x l0'- Producl Number: 303lBl -White@ 4'x l0'- Producl Number: 303182 - Ton- One- ond Two-Wqy Pressure Relief Vents APEET Proteclive Film APEEL Cover Tqpe w -- f ) IF- Engineered to reduce moislure within lhe roofing syslem ond releose tropped oir pressure wilhin the building. One-Woy Vents ollow lropped oir pressure to escope; Two-Woy Vents (combined with One-Woy Vents) help lo reduce moislure. Sizes Avoiloble: 8" x 1 .l " - Product Number: 327975 - One-Woy Pressure Relief Vent B" x I l " - Product Number: 327976 - Two-Wcy Pressure Relief Vent 0uontity Per Box:25 Pcs TPO Sizes Avqiluhle: 9" x 'l2"- Product Number: 334849 - TPO One-Woy Veni 9" x .l2" - Producl Number: 334480 - TPO Two-Woy Venl ouonlity Per Box: 4 Pcs PVC Sizes Avoiloble: 9" x -12" - Producl Number: 335592 - PVC One-Woy Venl 9" x -l2" - Product Number: 335593 - PVC Two-Woy Vent Quontiiy Per Box:4 Pcs Avoiloble in TPO ond PVC versions, T-Top Venls ore designed lo ollow 0ir lo flow freely through ihe vent while preveniing woler {rom infiltroiing the ro0fing sysfem. TPO Sizes Avoiluble: 2 Pcs/Box - 4" - Producl Number: 326896 - TPO T-Top Vent 2 Pcs/Box - 6" - Producl Number: 326882 * TPO T-Top Vent 3 Pcs/Box - B" - Product Number: 326883 - TPO T-Top Veni PVC Sizes Avoiloble: 2 Pcs/Box - 4" - Producl Number: 326868 - PVC T-Top Vent 2 Pcs/Box - 6" - Producl Number: 326880 - PVC T-Top Veni 3 Pcs/Box - B" - Producl Number; 32688l - PVC T-Top Vent Avoiloble on Versiweld 60-mil ond 80-mil TPO ond VersiFlex 60-mil PVC ond KEE HP membrones, APEEL Protective Film guords the membrone's surfoce from scu{fs ond dirl occumulolion during instollotion, eliminoling lhe need to cleon the roo{ upon roof completion. Duroble ond eosy to remove, APEEL Proteclive Film helps lo sove time ond lobor, improves oeslhetics 0nd longJerm reflectivily. E{m T-Top Vents APEEL Cover Tope is o 6"-wide. 1,640'-long roll of APEEL Proleclive Film used to protecl oreos of membrone where APEEL Proleclive Film hos been removed (oround deloils) or wos nol foclory opplied (seoms), APEEL Cover Tope ollows opplicotors lo keep 100 percent of lhe membrone surfoce cleon during instollolion ond is opplied using the APEEL Cover Tope Applicolor, Sizes Avoiloble: 6" x .l,640'- Product Number: 333093 Suontity Per Box: 2 rollsictn APEET Cover Tope Applicotor The APEEL Cover Tope Applicolor is mode of heovy-duly powder- cooled oluminum wilh sloinless sleel fosteners. ll holds one roll of APEEL Cover Tope ond uses size segmenled pressure wheels lo ensure proper odhesion. Product Code: 333095 7 TECHNICAL DATA BULLETIN '-,-,....' .:;i.'.t,i i-.. li::,... ;:1,:j:i:+..rjt.ji ;ri.i il I . .- .:..1'.j j: ; 'if,tilii;;i;,':i.r:..i1r j.!:;j:rrri :r,.,.,' , :.i:: Versi0ore@ Polyiso Overview Versi0ore is o rigid-roof insulotion ponel composed of o closed-cell polyisocyonurole foom core bonded on esch side to gloss-reinforced felt (GRF). Feolures <rnd Benefils ' Versi0ore polyiso insulotion provides ihe highesi R-volue per inch of commerciolly ovoiloble insulotion products " Zero ozone-depleting components, HFC- qnd HCFCJTee formulqfion . Approved for direct opplicoiion lo steel decks Ponel Ghoroclerislics Avoilqble in 4'x 4' (1220 mm x 1220 mm) qnd 4' x 8' (1220 mm x 2440 mm) ponels in thickness of 7/' (i3 mm) to 4.5"(115 mm) Applicolions ' Single-Ply Roof Systems (Bollosted, Mechonicolly Atioched, Fully Adhered) lnslollotion Bollosied Single-Ply Syslems Eoch VersiCore ponel is loosely loid on the roo{ deck. Butt edges ond stogger joinls of odjocent ponels. lnstoll the roof membrone occording to Versico's specificotions. VERSICO Mechonic0lly Al?0ched Single-Ply Syslems Versi0ore ponels must be secured io the roof deck with fosteners qnd plotes (oppropriote to the deck lype), Butl edges ond stoggerjoints of odjocent p0nels. lnstoll the roof membrone occording to Versico's specificotions. Fully Adhered Single-Ply Syslems VersiCore p0nels musi be secured to the roof deck wilh fosteners ond plctes (oppropriote to deck type). Butl edges ond sioggerjoinis of odjocent ponels. lnstoll the roof membrone occording io Versico's specificotions. Versi0ore 4' x B' ponels con be secured io the roof deck with Versico's Flexible DASH@ Adhesive, either full coveroge or beod spocing. Versi0ore 4' x 4' ponels moy be odhered to prepored concrele deck with o full mopping of Type lll or lV ospholt. REVIEW CURRENT VERSICO SPECIFICATIONS AND DETAILS FOR SPECIFIC INSTALLATION RESUIREMENTS, Godes qnd Complionces , ASTM Cl2B9, Type ll, Clqss l, Grode 2 (20 psi), Grode 3 (25 psi) " lnternqtionol Building Code (lBC) Section 2603 ' ULStondqrdT9O, 263ond 1256: Componentof ClossA Roof Systems (refer to UL Roof Mqteriols'system direciory) . FM@ Siondords 445014470: Closs 1 opprovol for steel roof-deck consiruciions (refer to FM RoofNovsM) ', Cqlifornio Code of Regulotions, IiIle 24, lnsulotion Quolity Stondord License #Tl-l4lB ' Third-porly certificotion with the PIMA Quolily Mqrk for Long-Term Thermsl Resistonce (LTTR) volues ', CAN/ULC 5704, Type 2, Clqss 3 (20 psi), Type 3, Closs 3 (25 psi) " Floridq Building Code Approvol ' CDPH compliont for moximum ollowoble concentrotions of torget VOCs Precoutions lnsulotion must be protecled from open flome ond kept dry ol qll times. lnsloll only os much insulslion os con be covered the some doy by compleied roof-covering moteriol. Proieci inslqlled product from excessive foot troftic. Vetsico will not be responsible for specific building qnd roof design by olhers, for deficiencies in construction or workmonship, for dcngerous condilions on the job siie or for improper storoge ond hondling. Technic0l specificotions shown in lhis literoture ore inlended l0 be used os generol guidelines only ond ore subject to chonge without notice. Coll Versico for more specific detoils, or refer to PIMA Technicol Bullelin No. 109: Storoge & Hondling Recommendqtions for Polyiso Roof lnsulation. ROOFING SYSTEMS TECHNICAL DATA BULLETIN Versi0ore Polyiso Typicql Properlies ond Chqrqclerislics VersiCore Polyiso Thermql Vqlues Physicol Propeily Iest Melhod Volue Thlcl(ness (lnches) Compressive Slrenglh ASTM D]62I 20 psi* minimum (138 kPo, Grode 2) A SINGIE SOURCE FOR SINGLE.PI.Y ROOFING 8OO.992.7 663 . www,versico.com tTTR R-volue r5.9 16.2 r6.B 17.4 IB 18.6 r8.9 r9.2 r9.9 20.5 21.1 21,7 22 22.3 0.5 Dimensionol Slobility 2olo lineor chonge (7 doys) Moisture Vopor Permeonce ASTM E96 <l perm (57.5 ng/(Po.srmz)) Woler Absorption cr763 <lolo volume Typicol properties ond ch0rocleristics oie b0sed on somples tesled ond ore not guoronteed for 0ll somples of lhis product. This doto ond informoiion is inlended os 0 guide 0nd does nol reflecl the specificolion ronge for 0ny p0rliculor property of ihis producl, *Also ovoiloble in 25 psi minimum, Grode 3 ASTM D2I26 0.75 t,r 1.2 1.25 1.3 1.4 1.5 r.6 1.7 1.75 1.8 1,9 ,ff,Foamed plastic as roof deck c0nstruction material with resistance to an intemal fire exposure only for use in c0nstruction no.(s) 120 and 123. See UL Directory of Products Certified for Canada and UL Rooling Materials and Systems Directory. 99D1. 23 @ptsf,;g;v,yi:::" 2.1 23.6 2.2 24.2 2.25 24.9 25.2 25.5 26.1 2.6 26.8 2.7 Flute Sp0nobilily is 2%" Ior 'l.4" or lhickness or smoiler. Flute Sponobility is 4%" for I 5' lhickness or greoier. 2.3 2,4 2.5 ffi VERSICO ROOFING SYSTEMS Thlckness (lnches) tITR R-Yqlue 2.8 2.75 2.84,2 5.7 2.9 6.3 a 6.8 3..l 3.27.1 7.4 3.25 3.3I 8.6 3.4 2RLl 9.7 3.6 3.7t0 r0.3 3.75 10,8 3.8 3.9I1,4 12 4 r2.6 4.1 12.9 4,2 4.13r3,2 t3.B 4.3 14.4 4.4 t5 4.5 15.6 O 2022 Versico. Printed in U.S.A. VE-8756 - 'Versioore Polyiso Technicol Doio Bullolin" - 08.29.22 Versico V6rsicore. DASH, ond the Versico Iogo ors l.odemorks o[versico. Quiclr Reference Guide \v,45-m[, 60-mtl 80-mfi 4" 6" 8" 10" 12" ond 16'x 100' rollVorsiweld TPo* t a r?;g. I 0' x 25'to 100' roll.V,60-mil ond 80-milVersiweld 8A TP0*v,100-mil, lls'mil, I35-mil 6'x 75', 6 x 100', 12'x 50''12'x75', l2'xl@'rV;iV,\v,VersiFleece TPo* rg .V,120-mll, 135-mil, 155-mil 6' x 75', l2' x 75'VersiFleeco AC TPO rV,rV, rV-I ls-mll 60 sq. f. per gollon t0' x 50', l0' x 100' 5 gollon pollVersiweld Bonding Adhosive VersiFleece RL TPO I .V,I .V, 560 T€chnicol Doto Bullslin #40 osrosol cylindel #85 oorosol cylindstiV-eV,iV, Wqll Afiochmsl only rV-CAV-GRIP 3V Adhesive/Primer 100 - 120 sq. tl. p€r gollon 5 gollon polliV,rV,Aquo Bose 120 Bonding Adhesive rvt S66 TDB MulliplsFlexlble DASH Adheslve 60 sq. lt. psr gollon 5 gollon poilLow-VoC Bonding Adhesive rV, 400 sq. tl. per gollon 'I gallon or 5 gollon poil.V,\v,.V,rI?,Weolhered Membrone Cleoner .V,50-67 sq. tl. per gollon 5 gollon pollCold Appli€d Adhesive (4) /, gollon pouchss/buckol\?.V,.17,I 22 cubic lnches por !, gollonWhite 0ne-Pon Seolqnl .V, rV,Approximotsly 1,320 sq. fl. per cylhder 27 lbs cylind€r.V,rV,.17,CAV-PRIME TPO Primel (6) 'l gollon cdns/coflonrV,rV,200 to 250 sq. lt. por gollonTPo Pdmer (Slondord ond Low-V0C)rV,rV, i.760 sq. lt./cylindsr 32 lbs. cyllnderrV,\:7t .V,CAV-PRIME LoW VOC EPDM Ond TPO PIimeI rV- .V,\v,225 llneor li. psr bottlo 6 botllos por corlonrl7,iV,TPo Cleor Cul Edge Seolonl 24 lub6t I 0.1 fl. oz. €och I p€r corlon .V,I rV, rV,I rlf, 25 fi. per lube ('/r" bood) qa" b8 Universol Single-Ply Seolonl TPO Molded Pipe Seols (Whle/Groy/ton) \v-I iV, .fgt v, 6" x 100'2 rolls psr corloniV,rVt .V,i9TPO PS Covorsrrlp 6" x 1 00' (Whlteicroyfi0n) \v,.9 I 2. x 50' ond 24" x 50'I por corlon.V,t?zTPO N0n-Reinlorced Flqshing (While/Grcy/I0n) I psr boxv,rg 1" lo 6"TPo Split Pipe Seols (Whlte/Groy/tqn).V,.V, rV,3'.4'. 5".6',I per boxrV,rvt rV,TPo Squore Tubing Wrops (While/Groy/ton) rV,v,'12 p€r bogrV,rl7,TPo lnslde/outslde Corner (White/Gr0y/T0n) 12 per bogv,.V,.V,il?,TPO lnside Cornels (While/Groyfion) rV,12 por bog.V,rvu .\v,TPO oulside Corners (White/6royfon) .V.\v-20 per boxrvtrS7,TP0 Univ€Isol C0rners (While/Gr0y/I0n) I 2 psr box.Vt iV,.V,TPo Cub Wrop Corners (White).17, .V.\v, 7", 13". 19' 7r,'to Il"x6"ovol 5 p6r corlonr?;.V,TPo Molded Se0l0nl Pockels (While/Gr0y/fon) I 0 per conontV;.V-.V,l4" overoll longli; 10" Inslolled lsngh.9TPo Seolonl Pockel Extsnsions (While) 6" x 100'2 rollsrl7-6" TPO PS RUSS l0'x 100''I roll tv, .l?,I O' TPO PS RUSS '100 por box Per roll .V- .\v, .V, .Vt TPO T-Joinl Covers (While/Gr0y/I0n) TPo Wolkwoy Rolls Ovhite, Groy & Ton) t?,I \v, 4/r" diomslor 34'x 50' roll .V, rV, I 0 or 25 p€r skid I 000 per pdckoggaV, \v-I \v, 4'x l0' 'l%'lo 8" - rV,I .17, rl7-I iV,lnsullile lnsulolion Fostene$ TPO Cooted Metal 4' x I 0' 1000 por pockogoil!l,\v,.S7,3" in diomol€r.V,3" Steel lnsulollon Plote 1%" lo '15"250 - 1000 psr pockogs.V,ivtHPV Fosleners (lnsulolion) 2" 1022"250 - 1000 por pockogerV,HPVX Fqslenorc (Membrone) 23h"1 000 por pockqgorV,HPVX PIOIOS MECHANICALLY ATTACHED FULLY ADHERED VERSIFLEECE VERSIFLEECEAC COVERAGE RATE OR AVAILABLE SIZES PACKAGING TPO Membrones TPO Adhesives ond Seolonls TPO Floshings Accessories TPO or PVC Fosteners . 4' - I 2' ovdiloble wilhVersico's APEEL Proleclive Film 29 250 - 500 p8r buckol.v,2 to 12'HPV-XL Foslensls (Slesl Dsck only) o 500 psr pockogs.Vt 3" dlomolsrTPo RhinoBond Plotes rv, .9 3' dlom€t€r l " wlds x .050 lhick x l0' longTeminolion Bor (AIuminum) PVC RhinoBond Ploles 500 psr pockoge 500 lF.v, 1000 psr pockogorv,-v,rvt lVa"I Y4' Term Bor Noil ln PACKAGING TPO or PVC fosleners VERSIFLEECE AC I Miscelloneous Accessories FULLY ADHERED COVERAGE RATE OR AVAITABLE SIZES MECHANICALLY ANACHED Quiclt Reference Guide iV, 50-mil, 60-mil,80-mil 40.5", 5" 81" ond I0'x 100'40.5", 5', 8l ", ond 10'x 75'VersiFlex PVC*rV, 50-mil, 60-mil, 80-mil 40.5", 5" 81", ond l0'x 100' 40.5" 5" 81 ", ond l 0' x 75'VersiF|ex KEE HP*\? rV, v, TV,rV-'I l5-mil.l35-mil t0'x 75" l0'x 100'VersiFleece PVC \v, 105-mil, I l5,mil 135-mir 10'x75', l0'x100'.V,rV,rDVersiFloece KEE HP eV,I .17, .V, .9 11s-mil 6" x 100' I 0' x 50', l0' x I 00' 2 rolls pgr boxPVC Pressure-Sensillve (PS) C,over Slrip (While/Groy/fon) VersiFleece RL PVC - rltt rV,.9 \v,I'x 75'I roll per corlonPVC & KEE HP Coverstrlp (Whlle/Groy/ton) 12".24" x50'I per corlon.V,rV,\?, 100 psr box\v'.17,41/2" dlomelat PVC Floshing (While/Groy/fon) PVC T-Joinl Covers (White/Groy/I0n)t?t 12 per bog.V,\vt \v,PVC lnside Corners (While/Gr0y/f0n) .V,12 p€r bogPVC 0ulside Corners (While/Gr0y/I0n)rV-{7- rVr rl9t 20 per boxPVC Universol Corners (While/Groy/fon).V, iV,7'.13".19"12 per boxrg.V,PVc Curb Wrop Cornorc (White/Gr0y/t0n) \v,1Yz" x6"5 psr corlonPVC Molded Seol0nt Pockets (While)rV,rV, I por boxv,%" lo 8" diom€tsr pipePVC Molded Pipe So0ls (Whileicroy/fon)iV, t?,l " lo 6" dlomolsr pipe I per boxrvt .17, r?;PVC Split Pipe Se0ls (Whito/Grqy/f0n) rvt 3", 4", 6'I p8r boxPVC Squore Tublng Wrops (While/Groyfi0n)\v,\v, I per cortonrV,.V,l"lo6"PVC Molded Pipe Floshings (While) .9T.V, PVC Splil Squore Tubing Wrops (While) Low-VoC PVC Bonding Adhosive 3" lo 6" 60 sq. lt. por gollon I psr corton 5 gollon poil Stondord - 4l# 90# tv- rV,WollAltochmenl only Stondord - 750 sq. tl. Lorge - 1,500 sq. fl.0AV-GRIP PVC Adhesive rl7,100-200 sq. fl. psr gollon 5 gollon poilrV,HydroBond Bonding Adhesive .17,Sso TDB MullipleFlexible DASH Adhesive (4) 'l gollon pouches/bucketil7,.V,.V,One Pon Pouroble Seoler (while) {?, I22 cubic inches por |, gollon 225' lo 275' (Ys" bead)(12) l6 oz. bolllevcoflon.Vt .V,PVC Cul-Edge Seol0nl (nol required) tv;.V-400 sq. fl. psr gollon 5 gollon poilPVC qnd KEE HP Membrone Cleoner iVt 2- ono gollon constV,.V,.V,250 - 300 sq. tl. pel gollonLow-VOC PVC Slep I Aclivotot .!4,700 sq. tt. p€r gollon 2- Ons gollon consrVtrV-Low-VOC PVC Slep 2 Pflmer rV,200 - 250 sq. lt. por gollon 4'xl0"sho€l PVc Slep 2 Primer PVC Cooled Melol el?, .V, 36" x 60' (91.4 cm x I 8.3 m) 2- ono gollon cons 10 sh€oilpdllsl Per rollPVC Wolkwoy Rolls (Groy) rV, aV, il7, .ftt rV, rV,rV,3' x 33' (91.4 cm x 18.3 m)PVC Crossgrip Wolkwoy White/Groy/ysllow) PVC Sysiems I\4ECHANICALLY ATTACHED FULLY ADHERED VERSIFLE ECE COVERAGE RATE OR AVAILABLE SIZES PACKAGING PVC Membrones PVC Floshings Pvc Adhesives dnd Seolonls PVC Coqled Melol & Wolkwoy PVC Fosteners - See Above * Avliloble wilh Versico's APEEL Prctective Film 30 Heat Welded TFO [rlembrane Fasteners FullyAdhered Steel Roof$eck Bonding Adhesive lnsulation I THERMOPLASTIC MEMBRANE 3" (z.scm) CLAMPING RING BY OTHERS WATER CUT_OFF MASTIC rPo/Pvc - HOT AIR WELD, 1-1/2" (+cm) vtN. NOTES: ROOF DRAIN SIZE AND NUMBER OF DRAINS SHALL BE IN ACCORDANCE WTH THE LOCAL CODES. 2. THE HOLE IN THE MEMBRANE SHALL EXCEED THE DIAMETER OF THE DRAIN PIPE, BUT SHALL BE NO LESS THAN 1/2" (1.5cm) FROM THE ATTACHMENT POINTS OF THE DRAIN CLAMPING RING. J. ALL BOLTS OR CLAMPS MUST BE IN PLACE TO PROVIDE CONSTANT COMPRESSION ON WATER CUT_OFF MASTIC. 4, REMOVE EXISTING LEAD, FLASHING MATERIAL & ENSURE THE DRAIN RING IS COMPLETELY CLEAN DOWN TO BARE METAL. 5. APPROXIMATELY 1rl8" (0.5cm) DIAMETER BEAD OF CUT_EDGE SEALANT IS REQUIRED ON CUT EDGES OF REINFORCED TPO MEMBRANE. 12" (30cm) 3 !l ICUT_EDGE TPO ONLY SEALANT a /:V/Z GREATER IHAN DIMENSION "X" MtN. 1/2" (t.scm) 2 DIMENSION "X" DRAIN PIPE4- PLAN k)1r4 TRIANGULAR ENTIRE SPLICE OVERLAP AT DRAIN BASE MUST BE HOT AIR WELDED DECK (FIELD) MEMBRANE HOT AIR WELD, 1-1/2" (+cm) tvtttl SECTIONS OF MEMBRANE THERMOPLASTIC ROOFING SYSTEM THERMOPLASlIC REINFORCED MEMBRANE - APPROVED SUBSTRATE o - sEE NoTE(s)TPC_6,2 ROOF DRATN (DRAIN SUMP GREATER THAN 3'' TO 1 HORTZONTAL FOOT) OPTION 1 v o 2023 VERSTCO ITHERMOPLASTIC MEMBRANE CLAMPING RING BY OTHERS \N NOTES: ROOF DRAIN SIZE AND NUMBER OF DRAINS SHALL BE IN ACCORDANCE WITH THE LOCAL CODES. 2. THE HOLE IN THE MEMBRANE SHALL EXCEED THE DIAMETER OF THE DRAIN PIPE, BUT SHALL BE NO LESS THAN 1/2" (1.5cm) rRoM THE ATTACHMENT POINTS OF THE DRAIN CLAMPING RING 3. ALL BOLTS OR CLAMPS MUST BE IN PLACE TO PROVIDE CONSTANT COMPRESSION ON WATER CUT_OFF MASTIC. 4. REMOVE EXIS]ING LEAD, FLASHING MATERIAL & ENSURE THE DRAIN RING IS COMPLETELY CLEAN DOWN TO BARE METAL. rPo/Pvc - 'tz" (30cm) J" (7.5cm) WATER CUT_OFF MASTIC 1 GREATER THAN DIMENSION "X" _:_€F_ MrN. 1/2" (t.Scm) DIMENSION "X" 2 DRAIN PIPE THERMOPLASTIC ROOFING SYSTEM TPC_6.1 THERMOPLASIC REINFORCED MEMBRANE - APPROVED SUBSTRATE o _ SEE NOTE(S) vVERSICO ROOFING SYSTEMS @ 2O2J \ERSICO ROOF DRAIN (DRAIN SUM UP TO 3 INCHES TO 1 HORTZONTAL FOOT) -THERMoPLASTIC MEMBRANE NOTES: WHEN USING TPO MEMBRANE, BONDING ADHESIVE IS NOT REQUIRED WHEN THE FLASHING HEIGHT lS 12" (3Ocm) OR LESS AND THE MEMBRANE IS FASTENED ''AS SHOWN'' ON TOP OF THE CURB. WHEN VERSICO TERMINATION BAR IS USED BENEATH THE COUNTER_FLASHING, BONDING ADHESIVE CAN BE ELIMINATED WHEN THE MEMBRANE HEIGHT IS 18" (+6cm) oR LESS. 2. APPLICABLE BONDING ADHESIVE FOR PVC OR TPO. IN CASE OF TPO, CAV_GRIP 3V ADHESIVE MAY ALSO BE USED ON VERTICAL PORTION. 3. WHEN MECHANICAL FASTENERS ARE USED TO PENETRATE THE METAL COUNTER_FLASHING, USE EPDM WASHERS, APPLY WATER CUT_OFF MASTIC UNDER THE COUNTER-FLASHING OR CAULK THE FASTENER HEADS. 4. APPROXTMATELY 1 /a" (O.Scm) DIAMETER BEAD OF CUT_EDGE SEALANT IS REQUIRED ON CUT EDGES OF REINFORCED TPO MEMBRANE. 5. REFER TO VERSICO SPECIFICATIONS FOR ACCEPTABLE VERSICO FASTENER AND PLATE. 6. MECHANICAL SECUREMENT MAY BE INSTALLED INTO THE VERTICAL SUBSTRATE 7. WHEN USING 60 MIL (t.smm) OR 80 MIL (z.o:mm) THICK cuRB FLASHING, THE INTERSECTIONS BETWEEN SPLICES MUST BE OVERLAID WTH A THERMOPLASTIC,'T-JOINT'' COVER. rPolPVC -MAXIMUM '12" (30cm) O.C. FASTENER SPACING METAL CAP OR COUNTER_FLASHING (BY oTHERS) APPLICABLE BONDING ADHESIVE- - THERMOPLASTIC REINFORCED MEMBRANE HOT AIR WELD, 1-1/2" (+cm) tr,ttN CUT EDGE SEALANT FOR TPO ONLY VERSICO FASTENER & SEAM FASTENING PLATE, MAX. 12" (30cm 5 3 4 7 INS T_JOINT COVER OUTSIDE CORNERS PER DETAIL TPC-15.4. TPC-15.5 OR TPC-15.7 THERMOPLASTIC MEMBRANE TO WRAP AROUND CURB USE ONE CONTINUOUS SHEET OF REINFORCED THERMOPLASTIC ROOFING SYSTEM TP C _ 5.1 _ APPROVED SUBSTRATE THERMOPLASTIC REINFORCED MEMBRANE o - sEE NoTE(S)-v il CURB FLASHING WITH TPO OR PVC MEMBRANEVE @ 2023 \ERSTCO FIN G SYS I TH ERM OPLASTIC M EM BRAN E HOT AIR WELD, i-1/2" (+cm) uttrt NOTES: WHEN USING 6O_MIL TPO OR 8O-MIL TPO OR PVC MEMBRANE, APPLY A 4-1 /2" (llcm) DIAMETER "T_JOINT" COVER AT ALL FIELD SPLICE INTERSECTIONS. 2. APPROXIMATELY 1/8" (0.5cm) DIAMETER BEAD OF CUT-EDGE SEALANT IS REQUIRED ON CUT EDGES OF REINFORCED TPO MEMBRANE. 3. WHEN USING 6O_MIL TPO, MAXIMUM WARRANTY IS 20 YEARS T_JOINT REQUIREMENTS CUT_EDGE SEALANT FOR TPO ONLY rPo/Pvc - DIMENSIONS cm (D 2-1 /4"6 MIN. 2 @ 1 ).. THERMOPLASTIC T-JOINT COVER MEMBRANE THICKNESS 45/5o 60 80 PVC N/A N/A YES KEE HP N,/A N/A YES TPO N/A YES YES THERMOPLASTIC ROOFING SYSTEM TPC_2,0 THERMOPLASIIC REINFORCED MEMBRANE 0 - APPROVED SUBSTRATE - sEE NOTE(S) MEMBRANE SPLICE vVERSICO -ROoFiNG SYSTEMS @202J VERSICO r THERMOPLASTIC MEMBRANE TPOIPVC I WOOD NAILER MUST EXTEND PAST TOTAL WDTH OF METAL FASCIA DECK FLANGE. APPROXIMATELY 1rl8" (0.5cm) DIAMETER BEAD OF CUT_EDGE SEALANT IS REQUIRED ON CUT EDGES OF REINFORCED TPO MEMBRANE. HOT AIR WELD,1-1/2" (4cm) MlN. NOTES:CUT_EDGE SEALANT FOR TPO ONLY VERSITRIM HEAT WELDABLE DRIP EDGE FASCIA MINIMUM 22-GAUGE CONTINUOUS CLEAT 2. 1-1/2" (:Smm) RING SHANK NAILS @ 6" (15cm) o.c. 2 WOOD NAILER (BY OTHERS) 1 1 INSTALL CONTINUOUS CLEAT AND COATED METAL WTH 1/8"-1/4" (o.5-1cm) ..lotttts BETWEEN ADJOINING SECTIONS. 2 WIDE PIECE OF MOPLASTIC HEAT WELD 3" (7.5cm) NON_REINFORCED THER MEMBRANE OVER JOINT 3 HEAT WELD 6" (1Scm) WIDE PIECE OF NON_REINFORCED MEMBRANE OVER JOINT + 2 POSITION FIELD MEMBRANE AND HEAT WELD COATED METAL A MINIMUM 0F 1-1 /2" (4cm) AS SHOWN. SEALAN CUT-EDGE HOT AIR WELD 1-1/2" (+cm) MIN. THERMOPLASTIC ROOFING SYSTEM TPC_1,2 _ APPROVED SUBSTRATE --HFHR:$'il8u,^o,,0 - sEE NoTE(s) VERSITRIM HEAT WELDABLE DRIP EDGE FASCIA r9 RO o 202J VERSTCO TTHERMOPLASTIC MEMBRANE VERSICO FASTENER VERSICO HPVX FASTENING PLATE ENCAPSULATED SHEET EDGE (NON-RETNFORCED) rPo/Pvc - MEMBRANE EDGE '7,PRE-PRINTED LINE FOR MEMBRANE OVERLAP --l \r \ NOTES: FASTENER SPACING GUIDE PRE-PRINTED 6" (tscm) o.c. ON MECHANICALLY ATTACHED SYSTEMS, HPVX FASTENERS AND PLATES OR HPV_XL FASTENERS AND PLATES ARE REQUIRED OVER STEEL AND WOOD DECKS. ON CONCRETE DECKS, CD-10 OR MP 14-10 FASTENERS ARE USED WTH HPVX PLATES. POSITION SEAM FASTENING PLATES BEYOND NON_REINFORCED ENCAPSULATED EDGE. 2. 1 2 DIMENSIONS cm @ s-1 /2"14 APPROX. G)1 /2"1.5 APPROX. THERMOPLASTIC ROOFING SYSTEM lHERMOPLASTIC REINFORCED MEMBRANE 0 * APPROVED SUBSIRAIE - sEE NorE(s)TPM A_2.2 FASTENER AND PLATE PLACEMENT vVERSICO ROOFING SYSTEMS o 2023 VERSTCO ITHERM OPLASTIC MEMBRAN E 5-1 1 4cm HOT AIR WELD, 1-1/2" (4cm) MlN. T_JOINT REQUIREMENTS NOTES: ON MECHANICALLY ATTACHED SYSTEMS, HPVX FASTENERS AND PLATES OR HPV-XL FASTENERS AND PLATES ARE REQUIRED OVER STEEL AND WOOD DECKS. ON CONCRETE DECKS, CD_10 OR MP 14_10 FASTENERS ARE USED WTH HPVX PLATES. POSITION SEAM FASTENING PLATES BEYOND NON_REINFORCED ENCAPSULATED EDGE. APPROXTMATELY 1/8" (0.5cm) DIAMETER BEAD OF CUT_EDGE SEALANT IS REQUIRED ON CUT EDGES OF REINFORCED TPO MEMBRANE. rPo/Pvc - 1/2" (1.5cm) APPROX. 2. 3. VERSICO FASTENER & SEAM FASTENING PLATE, MAX. 12" (socm) o.c. 't MEMBRANE THICKNESS +s/so 60 80 PVC N/A N/A YES KEE HP N/A N/A YES TPO N/A YES YES MEMBRANE -_-\/\\t.tl\ MEMBRANE >.,./2.// CENTERED./ MEMBRANE JOTNT THERMOPLASTIC T_JOINT COVER THERMOPLASTIC ROOFING SYSTEM TP M A- 2.1- - HF^HR'.S'ilEur*or. l-11++l-+#+l-l-l - APPRoVED suBSrRAlE 0 - sEE NorE(s) MECHANICALLY ATTACHED MEMBRANE SPLICE vVERSICO ROOFING SYSTEMS o202J \ERS|CO ITHERMOPLASTIC MEMBRANES ANY TPC-g TERMTNATToN (ABOVE ANTICIPATED WATER LEVEL) VERSICO FASTENERS AND RhinoBOND FASTENING PLA VERSICO FASTENERS AND RhinoBOND FASTENING PLATES RhinoBondl NOTES FASTENERS MUST PENETRATE INTO WOOD OR METAL STUDS, WHERE WALL IS BUILT WTH STUDS. 2. HPVX FASTENERS AND RhINOBOND PLATES ARE REQUIRED OVER STEEL AND WOOD DECKS. 1 2 VERSICO RhinoBond RB_3 RhinoBOND - WALL ATTACHMENT vVERSICO R OOFIN G SYSTEM S @202J rrERgco ITHERMOPLASTIC MEMBRANES ROOF ZONES FOR IMTNTMUM ONE FASTENER PER 4 SQUARE FEET (0.372 SQUARE METER)I SPLIT LEVEL ROOFS GREATER THAN 10 FT (3m) g'-0" (2.am) PERIMETER WDTH \ \ WDTH SPLIT LEVEL ROOFS LESS THAN 10 FEET (3m) 8'-0" (z++cm) PERIMETER MAIN ROOF EXTENDING ON THE SAME LEVEL ..-o9 -- CANOPY ROOF \N \ DOCKS 20'-0" (6.1m) LARGE OPENINGS OR LOADING NOTES: PLATE, 12''30cm) O.C. MEMBRANE MAX. INDUCTION WELDED 3-1 "To4" (s-t ocm) q ANGLE CHANGE SECUREMENT VersiWELD MEMBRANE REQUIRES VersiWELD BONDING ADHESIVE AND VeTSIFLEX MEMBRANE REQUIRES VersiFLEX BONDING ADHESIVE. 2. HPVX FASTENERS AND RhiNOBOND PLATES ARE REQUIRED OVER STEEL AND WOOD DECKS. FOR WARRANTY WND SPEEDS GREATER THAN 72 MPH PLEASE CONTACT VERSICO FOR REQUIRED FASTENING ENHANCEMENTS *16CM/ONE METER FASTENERS REQUIRED @ 12" (50cm) 0.c., WHEN MEMBRANE ANGLES GREATER THAN SHOWN SLOPE 3-1/2" rO 4" (s-tocm) RhinoBondl THERMOPLASTIC REINFORCED *2": I 2"1 TPC_9 TERMINATION (ABovE ANTTcTPATED WATER LEVEL) VERSICO BONDING ADHESIVE VERSICO FASTENER AND RhinoBOND FASTENING 1 SEE SKETCH ABOVE VERSICO RhinoBond RB_2 ANGLE CHANGE SECUREMENT METHOD WITH RhinoBond PLATES vVERSICO ROOFING SYSTEMS @2o2J vERgco ITHERMOPLASTIC MEMBRANE NOTES: RhinoBond METHOD 0F MEMBRANE ATTACHMENT IS NOT FOR USE WTH NON-FACED EPS (EXPANDED POLYSTYRENE) OR XPS (EXTRUDED POLYSTYRENE) INSULA]IONS. 2. PERIMETER ENHANCEMENTS REQUIRED FOR V/IND SPEED COVERAGE GREATER THAN 72\APH. CONTACT VERSICO FOR REQUIREMENTS. 3. ENHANCEMENT SHOWN ARE FOR THE PURPOSE OF THE VERSICO WARRANTY. FOR FM PROJECTS CONSULT FM GLOBAL FOR REQUIRED ENHANCEMENTS. 8'-0" RhinoBondl RAISED ROOF EDGE OR PARAPET WALL SEE B SEE A FOR DIM MENSIONS 4'-0"4'-0"4'-0"4'-0"8'-0" MtN. AREA MEMBRANE FASTENED MINIMUM 12" 0.C. AT ANGLE(S) CHANGES. FOR ADDITIONAL INFORMATION SEE DETAIL RB_2 Llz..oZN>E -tdb !-:,U-r >co oatd(L Ld E. oJtrltr L!oo E. il +N +N:I 12" 24" 24" 24" 12" PERIMETER ZONE 8 FASTENERS PER 4'X8' BOARD 8'-0" 4 4 30" q- FIELD OF ROOF 6 FASTENERS PER 4'X8' BOARD PERIMETER AREA [_:--_] flELD AREA VERSICO FASIENER &@ @ RhinoBond FASTENER PLATE DETAIL RB_2 FEET TO CENTIMETERS FEET 1 4 I cm 30 122 244 18"30"8 INCHES TO CENTIMETERS inch 2"5.5"4"12"18"24 30" cm 5 I 10 30 46 61 76 a a DECK TYPE DECK THICKNESS FASITNER THERMOPLASTIC COATED PLATE STEEL 22 GAUGE (0.8mm)VERSICO HPVX FASIENER J-1rl8" (8cm) DIAMETER PLYWOOD 15/32" (12mm) NOTE: AT IN-FILL MINOR PIECES, USE MlN. 2 FASTENERS. VERSICO RhinoBond RB-1 RhinoBond ATTACHMENT METHOD-NUMBER OF FASTENERS AND LOCATION v @202J \€Rsrco TPO AND PVC ROOFING SYSTEMS VersiWeld@ TPO/ VersiFlex" PVC/VersiFlex" FRS PVC/ VersiFlex" KEE HP Mechanically Attached and Fully Adhered Roofing Systems January 2023 The information contained in this generic specification represenfs a part of Versico's requirements for obtaining a roofing sysfem warranty. Construction materialsbnd practices, buitding siting and operation, climatic conditions, and other site-specific factors will haie an impact on the performance of the roofing system. Versico recommends that the building owner retain a design professiona! to determine appropriate design rneasures to be taken in order to address these factors. This section ls fo serye as criteria for Specifiers and Authorized Contractors regarding the design and installation of Versico's Fuily Adhered and Mechanically Attached Thermoptastic Membrane Roofing Sysfems. Additional information essential for the aeiign and installation of the roof system mentioned herein are also inctuded in the Design Reference Section and also listed in the iorm of a Specification Supptement at the end of the Technical Manual. Spec/ters and Authorized Contractors are advised to reference all applicable sec/lons. Various Warranty Tables have been included in Paragraph 1.05 citing various requirements by which specific warranty coverage can be obtained. Appropriate Warranty Table should be referenced to ensure proper warranty coverage. PART I _ GENERAL 1.01 Description Mechanically Attached Systems (VersiWeld / VersiFlex) j. The VersiWeld Mechanically Attached Roofing System incorporates 12',10'or 8'wide, white, tan or gray 45, 60, or 80-mil thick scrim-reinforced, VersiWeld Thermoplastic Polyolefin (TPO) membrane field sheets (also available in special colors in 60-mil thick, maximum 10'wide sheets). lnsulation is mechanically attached to an acceptable roof deck. VersiWeld perimeter sheets (6' used with 10' and 12'wide field sheets; 4' used with 8' wide field sheets) are installed along building edges and field membrane sheets are Mechanically Attached to the roof deck with the appropriate Versico fasteners and fastening plates. Adjoining sheets of VersiWeld membrane are overlapped and joined together with a minimum 1-112" wide heat weld. Membrane fastening requirements are outlined in Warranty Tables in Paragraph 1.05 of this Specification. 2. The VersiFlex Mechanically Attached Roofing System incorporates 50, 60 or 80-mil thick Polyester Reinforced VersiFlex Polyvinyl Chloride (PVC) membrane (white, gray, light gray, slate gray and tan) OR 50' 60 or 80-mil thick Polyester Reinforced VersiFlex KEE HP (High Performance) Membrane (white, gray, light gray or tan). Either membrane is available in 10' wide (white, gray, light gray, sla!" .gt?y.9n9 tan) field sheets Snci S' perimeter sheets. Standard Polyester Reinforced membrane is also available in 8''l" wide (white, gray or tan) fieid sheets and 40.5" perimeter sheets. VersiFlex sheets are available in 75' or 100' rolls. All sheets are mechanically attached over an approved insulation/underlayment to an acceptable roof deck with the appropriate Versico Fasteners and Fastening Plates. Adjoining sheets of VersiFlex membrane are overlapped ahb ;oineO together with a minimum 1-112" wide heat weld. Membrane fastening requirements are outlined in Warranty Tables in Paragraph 1.05 of this Specification NOTE: Either Roofing System may be specified utilizing the RhinoBond attachment method, refer to Attachment l, at the end of this specification for additional information. NOTE: Either Roofing System may be specified over an existing standing seam, flat seam or corrugated metal roof (mechanicaity attacn6d systems incorporate membrane securement into the structural purlins). Refer to the Meial Retrofit Roofing System Specification, published separately, for applicable requirements. Fully Adhered Roofing systems (Versiweld / versiweld QA TPO / VersiFlex) The VersiWeld Fully Adhered Roofing System incorporates maximum '12' wide white, gray or tan 45, 60 or 80-mil thick sc1m-reinforced VersiWeld Thermoplastic Polyolefin (TPO) membrane (also available in '16'wide white 4b, 60 or 80-mil and special colors in 60-mil thick, maximum 10' wide sheets). Versico lnsulation is mechanically attached to the ioof deck or secured with Flexible DASH Adhesive, OlyBond 500 BA, or OlyBond Spot Shot Adhesive and the membrane is fully adhered to the insulation with the appropriate VersiWeld Bonding Adhesive. Adjoining sheets of membrane are overlapped approximately 2" and joined together with a minimum A B I 3Thermoplastics 1/2023 1-112" wide heat weld. 2. The VersiWeld OA TPO (Quick-Applied TPO) membrane is a heat-weldable single-ply thermoplastic polyolefin (TPO) sheet available in 10' wide, (white, tan or gray) 60 or 80-mil thick reinforced TPO membrane laminated to an elastomeric pressure-sensitive adhesive. 3. The VersiFlex Fully Adhered Roofing System incorporates maximum 10' wide, 50-mil, 60-mil or 80-mil thick Fiberglass reinforced VersiFlex FRS Polyvinyl Chloride (PVC) membrane (white, gray, light gray, slate gray and tan). Versico lnsulation is mechanically attached to the roof deck or secured with an approved adhesive and the membrane is fully adhered to the substrate with VersiFlex PVC Low-VOC Bonding Adhesive, CAV-GRIP PVC or Hydrobond Water-Based Adhesive. Adjoining sheets of membrane are overlapped and joined together with a minimum 1-112" wide heat weld. A KEE HP enhanced (white, gray, light gray and tan) VersiFlex KEE HP membrane with Polyester Reinforcement and is available in 5' and 10'width. Polyester Reinforced membrane is available in widths of 40.5", 5', 81" and 10'wide (white, gray, light gray, slate gray and tan). Fiberglass Reinforced membrane is available in widths of '10' (white, gray, light gray or tan). 1.02 General Design Gonsiderations Various Warrang Tables have been included in Paragraph 1.05 citing various requirements by which specific warranty coverage can be obtained. Appropriate Warranty Table should be referenced to ensure proper warranty coverage. A. The maximum roof slope for Mechanically Attached Roofing Systems is 18" in one horizontal foot. There are no maximum slope restrictions for the application of the Fully Adhered Roofing System. B. The mechanically attached roofing system is not acceptable for installations on steel decks lighter than 22 gauge unless the steel deck is used in conjunction with lightweight concrete and a minimum of 360 pounds pullout per fastener is achieved with HPVX Fasteners into the steel deck below. A Fully Adhered Roofing System may be specified or refer to the Metal Retrofit Roofing System Specification, published separately for other roofing options. C. Certain petroleum based products, chemicals, and waste products may not be compatible with these roofing membranes. Contact Versico for verification of compatibility and recommendations concerning an acceptable roofing membranes. D. Metal-Edge Systems and Copings should be designed in compliance with Section 1504.5 of the lnternational Building Code and shall be tested in accordance with ANSI/SPRI ES-1 . E. Concentrated loads from rooftop equipment may cause deformation of insulation/underlayment and possible damage to the membrane if proper protection is not provided. A protection course or sleepers must be specified. F. lt is the responsibility of the specifier to review local, state and regional codes to determine their impact on the specified Versico Roofing System. G. lt is the responsibility of the building owner or his/her designated representative to verifi structural load limitation. ln addition, a core cut may be taken to verify weight of existing components when the roofing system is to be specified on an existing facilitY. H. Construction Generated Moisture / Vapor Drive 1. On new construction projects, especially in cold climate regions, moisture generated due to the construction process could adversely impact various components within the roofing assembly if not addressed. Refer to besign Reference DR-01-21 "Construction Generated Moisture" included in the Versico Technical Manual. 2. On structural concrete decks, when a vapor retarder is not used, gaps in the deck along the perimeter and around penetrations must be sealed along with vertical joints between tillup panels, if present, to prevent infiltration of hot humid air and possible moisture contamination resulting from condensation. This is specifically important when adhesive is used to attach the roof insulation. NOTE: lf left unaddressed, collected moisture could weaken insulation boards and facers resulting in a blow-off or increase the probability of mold growth. L Drainage 1. Drainage must be evaluated by the specifier in accordance with all applicable codes. Slopes may be provided by tapering the structure or through the use of tapered insulation; a sufficient number of roof drains should also Thermoplastics 1/2023 4 J. be specified and properly located to allow for positive drainage. Significant ponding that could remain after 48 hours should be eliminated with the addition of auxiliary drains in low areas where ponding is anticipated. Versico specifically disclaims responsibility for the design and selection of an adequate drainage system and drain accessories. Selection must be made by the building owner or the owner's design professional 2. Small incidental areas of ponded water will not impact the performance of this roofing system, however, in accordance with industry standards, the roofing assembly should be designed to prevent ponding of water on the roof for prolonged periods (longer than 48 hours). Good roofing practice dictates proper drainage to prevent possible excessive live load and, in the event of a roof leak, to minimize potential interior damage to the roofing assembly and to the interior of the building. 3. Ta'pered edge strips, crickets or saddles are recommended where periodic ponding of water may occur. When the slope of the taper exceeds 2 inches to one horizontal foot, additional membrane securement at the base of the tapered edge strip will be required. 4. Subject to code requirement, it is recommended that a minimum roof slope of 1/8" per horizontal foot be provided to serve long-term aesthetics. On new construction projects, roof drains should be positioned in areas where minimum deflection is anticipated. Slopes greater than 1/8" per foot should be considered due to possible roof deflection. Retrofit - Recover Projects (when the existing roofing material is left in place) 1. The removal of existing wet insulation and membrane must be specified. The specifier shall select an appropriate and compatible material as filler for voids created by removal of old insulation or membrane. 2. Entrapment of water between old and new membrane can damage and deteriorate new insulation/underlayment between the two membranes. lf a vapor retarder or air barrier is not specified, Versico recommends existing membrane be perforated to avoid potential moisture accumulation to allow for detection of moisture to enable the building owner to take corrective action. This can be accomplished by drilling approximately 3/4" diamele_r holes every 100 square feet in the existing built-up roof or single-ply membrane (excluding non-reinforced PVC membrane). 3. lf total removal of existing non-reinforced PVC membrane is not specified, existing membrane may be cut into maximum 10'x 10'sections, when the new insulation or membrane underlayment is to be mechanically attached. 4. Regardless of the type of membrane or assembly selected, any loose flashings at the perimeter, roof drains and roof penetrations must be removed. 1.03 Quality Assurance Building codes are above and beyond the intended purpose of this specification. The building owner, owner's repres6ntative or Specifier should verify local codes for applicable requirements and limitations. lt is the responsibility of the specifier to review local, state and regional codes to determine their impact on the specified Versico Roofing System. NOTE: For code approvals achieved with the Versico Roofing Systems, refer to the Versico Code Approval Guide, DORA (Direciory of Roof Assemblies), Factory Mutual (FM) Approval Guide or Underwriters Laboratories (UL) Fire Resistance or Roofing Materials and Systems Directories' A. When recovering or retrofitting an existing roof system, the addition of new insulation (type and thickness) may alter the fire performance characteristics of the assembly. Building owners or their designated representatives shall consult the local code enforcement agency to avoid potential code violation. B. Versico recommends the use of Versico supplied products for use with VersiWeldA,/ersiFlex Roofing Systems. The performance or integrity of products by others, when selected by the specifier and accepted as compatible by Versico, is not the responsibility of Versico and is expressly disclaimed by the Versico warranty. C. This roofing system must be installed by a Versico Authorized Roofing Contractor in compliance with drawings and specifications as approved by Versico. D. There must be no deviations made from Versico's specifications or Versico's approved shop drawings without the PRIOR WRITTEN APPROVAL of Versico. E. After completion of the installation, upon request, an inspection shall be conducted by a Technical Representative of Versico to ascertain that the membrane roofing system has been installed according to Versico's published specifications and details applicable at the time of bid. This inspection is to determine whether a warranty shall be Thermoplastics 1/2023 5 issued. lt is not intended as a final inspection for the benefit of the owner. F. Coordination between various trades is essential to avoid unnecessary rooftop traffic over completed sections of the roof and to prevent subsequent damage to the membrane roofing system. G. The solar reflectance of this roofing product may decrease over time due to environmental defacement such as dirt, biological growth, ponded water, eti. The roof should be monitored at regular intervals and maintained or cleaned when necessary to assure the maximum solar reflectance. H. Refer to the Design Reference DR-07-20 'CRRC/LEED lnformation" for information. (i.e. solar emittance, solar reflectance and recycled content) 1.04 Submittals A. To ensure compliance with Versico's minimum warranty requirements, the following projects should be foruvarded to Versico for review prior to installation, preferably prior to bid: 1. Air pressurized buildings, canopies and buildings with large openings where the total wall openings exceed 10% of the total wall area on which the openings are located (such as airport hangars, warehouses and large maintenance facilities). 2. Cold storage buildings and freezer facilities. 3. Fully Adhered Roofing System projects over 250' in height (maximum 15 year warranties) and 100' in height (warranties greater than 15 years). 4. Mechanically Attached Roofing System projects over 100' in height regardless of warranty duration. S. projects where the VersiWeld or VersiFlex membrane is expected to come in direct contact with petroleum- based products or other chemicals. 6. Mechanically Attached systems specified with a fastener length exceeding 12 inches. Along with the project submittals (shop drawings and Request for Warranty), the roofing contractor must include pullout tests when results are below the requirements identified in this specification. B. c.Shop drawings must be submitted to Versico by the Versico Authorized Rooftng Contractor along exeiuted Co-py-A Job Approval Request for approval. Approved shop drawings are required for roof and on projects where on-site technical assistance is requested. Shop drawings must include: with a completely inspection of the D. 1. Outline of roof and size 2. Deck type (for multiple deck types) 3. Location and type of all penetrations 4. Perimeter and penetration details 5. Key plan (for multiple roof areas) with roof heights indicated 6. Sheet width and number of perimeter sheets for Mechanically Attached systems 7. Fastener type, length and maximum spacing (for membrane securement) for Reinforced Mechanically Attached systems. Along w1h the project submittals (shop drawing and Request for Warranty), the roofing contractor must include pulloirt test results when the results are below the requirements identified in, Table included in Design Reference DR-06-1 9 "Wthdrawal Resistance Criteria". When field conditions necessitate modifications to originally approved shop drawings, a copy of the shop drawing ouflining all modifications must be submitted to Versico for revision and approval prior to inspection and warranty issuance. As-Built Projects (roofing systems installed prior to project approval by Versico) The Versico Authorized Contractor may supply Versico with an As-Built drawing for a pro.lect completed prior to Versico's approval. The As-Built drawings: 1. Must conform to Versico's most current published specifications and details applicable at the time of bid. 2. Must be submitted along with a completely executed copy-B Job Completion. 3. Must include the items identified in Paragraph 1.O4.C. bThermoplastics 1/2023 NOTE: As-Built projects are not recommended for those projects referenced in Paragraph 1.04A in order to ensure Versico warranty requirements have been met. E. Gopy-B Job Gompletion After project completion, a Copy-B - Job Completion Date must be submitted to Versico to schedule the necessary inspection of the project prior to issuance of the Versico Warranty. 1.05 Warranty A. B. A Total System Warranty is available for roofing systems on commercial buildings within the United States and applies onty to products marketed by Versico. The total system is defined as membrane, flashings, adhesives, sealants anO otner Versico brand products utilized in the installation. For a complete description of these products, refer to the Part ll "Products" Section in this Specification and Spec Supplement "Related Products" P-01-21. See Tables Below for information regarding Warranted Systems and Design Criteria: j. TABLE I - Minimum Membrane Thickness for Various Warranty Options ldentifies minimum membrane thickness for Reinforced membranes used in fully adhered or mechanically attached roofing systems' 2. TABLE ll - Mechanically Attached Roofing systems - TPO Membrane Fastening Griteria - steel/concrete Decks ldentifies fastening density, field membrane width and number perimeter sheets required for the various wind zones. The assembiies are categorized based on various building height and specific wind speed warranty coverage. 3. TABLE lll - Mechanically Attached Roofing Systems - PVC / KEE HP PVG Membrane Fastening Criteria - Steel/Concrete Decks ldentifies fastening density, field membrane width and number perimeter sheets required for the various wind zones. The aJsemblies are categorized based on various building height and specific wind speed warranty coverage. 4. TABLE lV - Mechanically Attached Roofing Systems - TPO Membrane Fastening Criteria - Wood Decks ldentifies fastening densiiy, field membrane wiOin and number perimeter sheets required for the various wind zones. The asseriblies aie categorized based on various building height and specific wind speed warranty coverage. 5. TABLE V - Mechanically Attached Roofing Systems - PVC / KEE HP PVC Membrane Fastening Griteria - Wood Decks ldentifies fastening density, fietO memorane width and number perimeter sheets reQuired for the various wind zones. The assemdlies are categorized based on various building height and specific wind speed warranty coverage. 6. TABLE Vl - Mechanically Attached Roofing Systems - TPO Membrane Fastening Griteria - Up to 20 Yrs - Lightweight lnsulating-Concrete over SteeyGypsum/Cementitious Wood Fiber Decks ldentifies fastening ceniity, fieid membrane-wiotn and number perimeieir sheets required forthe various wind zones. The assemblies are caiegorized based on various building height and specific wind speed warranty coverage. 7. TABLE Vll - Mechanically Attached Roofing Systems - PVC / KEE HP PVG Membrane Fastening Criteria - Up to 20 yrs - Lighhfl;rignt lnsulating Conirete over Steel/GypsumlGementitious Wood Fiber Decks toentities fastening d-ensity,-field membrane width and number perimeter sheets required for the various wind zones. The assemblies are categorized based on various building height and specific wind speed warranty coverage. 8. TABLE Vlll-Fuily Adhered Roofing Systems - Underlayment and Fastening Density forTPO Assemblies with Warranties Up to 20 Yrs tieniiRes required underlayments for fully adhered rqofjng systems with Warranties up to 20 years based on the various wind speed coverages available. The Table also identifies fastening density or adhesive bead spacing and required edge terminations' 9. TABLE lX - Fully Adhered Roofing Systems - Underlayment.and Fastening Density for VersiWeld QA Assemblies with Warranties Up to ZO Vrs ldentifies required underlayments fol fully q!he1ed roofing systems w1h Warranties up to 20 years based on the various wind speed coverages available. The Table also identifies fastening density or adhesive bead spacing and required edge terminations. 10. TABLE X - Fully Adhered Roofing Systems - Underlayment and Fastening Density forTPO Assemblies with Warranties - 25 to 30 yR iOe-ntities required underlayments for fully adhered roofing systems with Warranties from 25 to 30 years based on the various wind speed coverages available. The Table also identifies fastening density or adhesive bead spacing and required edge terminations. 11. TABLE Xl- Fully Adhered Roofing Systems - Underlayment and Fastening Density for VersiWeld QA 7Thermoplastics 1/2023 Assemblies with Warranties - 25 to 30 YR ldentifies required underlayments for fully adhered roofing systems with Warranties from 25 to 30 year based on the various wind speed coverages available. The Table also identifies fastening density or adhesive bead spacing and required edge terminations. 12. TABLE Xll -Fully Adhered Roofing Systems - Underlayment and Fastening Density for PVC / KEE HP PVC Assemblies with Warranties Up to 20 Yrs ldentifies required underlayments for fully adhered roofing systems with warranties up to 20 years based on the various wind speed coverages available. The Table also identifies fastening density or adhesive bead spacing and required edge terminations. 13. TABLE Xlll - Fully Adhered Roofing Systems - Underlayment and Fastening Density for PVG / KEE HP PVC Assemblies with Warranties - 25 to 30 YR ldentifies required underlayments for fully adhered roofing systems with warranties from 25-30 year based on the various wind speed coverage available. The Table also identifies fastening density or adhesive bead spacing and required edge terminations. 8Thermoplastics 1/2023 Table I Mechanically Attached or Fully Adhered Membrane Systems Warranty Options Notes: N/A = Not Acceptable {= Acceptable (1) Contact Versico for specific requirements. (Z; ntt "t-loints" must be overlaid with appropriate flashing material when using 60- or B0-mil TPO or B0-mil PVC/KEE HP membrane. (a; nqua -Base 120 adhesive may be used for projects with 20 year maximum warranty and wind speed coverage up to 72 mph. Hydrobond Adhesive may be used for projects with 20 year maximum warranty and wind speed coverage up to 90 mph. (4) VersiWeld QA TPO 60-mil membranes may be used. VersiWeld B0-mil TPO in Special Colors are limited to Warranties Up to 20 Year. (5) VersiWeld QA TPO 80-mil membrane can be used in lieu of VersiWeld BO-mil membrane. (Oi Versif tex FRS membrane can be used in lieu of VersiFlex Polyester reinforced membrane for Fully Adhered Roofing Systems Only. (7) VersiFlex KEE HP PVC 50-mil membrane can be used in lieu of VersiFlex 60-mil membrane for Warranties Up to 20 Year. (8) VersiFlex KEE HP PVC 60-mil membrane can be used in lieu of VersiFlex B0-mil membrane for Warranties Up to 25 Year. (g) Enhancements may be required for certain flashing details. Publish details must be referenced for applicable requirements. (10) VersiFlex PVC 60- or 80-mil membranes in Slate Gray are limited to Warranties Up to 20 Year. (1 1) Low-VOC PVC Bonding Adhesive or CAV-GRIP PVC must be utilized. I Thermoplastic Membranes (VersiWeld TPO / VersiFlex PVC / VersiFlex KEE HP) 55,72,80 or 90 mph 100 mph 110to120mph Additional Hail/Puncture CoverageFully Adhered Mech. Attached Fully Adhered Mech. Attached Minimum Membrane Thickness (2) Years Fully Adhered Mech. Attached VersiWeld 45-mil OR VersiFlex 50-mil (6) See BelowN/A(1)N/A5,1 0, or '15 year See BelowN/A N/A VersiWeld 60-mil (4) OR VersiFlex 60 mil (6) OR VersiFlex KEE HP 50-mil 20 year {(sl N/A N/A VersiWeld 80-mil (5) OR VersiFlex 80-mil (6XBX1 0) See BelowN/A25 year (e) See BelowN/A N/A N/A VersiWeld B0-mil (5) OR VersiFlex 80-mil (1 1) OR VersiFlex KEE HP 80-mil (10) 30 year (e)J VersiWeld TPO Membrane Hail - 1" Dia. Hail Coverage requires a minimum of 60-mil TPO Adhered to cover board. - 2" Dia. Hail Coverage requires 80-mil TPO Adhered to cover board. Additional Design Requirement: - Cover board (SecurShield HD, SecurShield HD Plus, Securshield HD or DuraFaceR Composite, DensDeck Prime, DensDeck StormX Prime, or Securock - Adhered Only). Puncture- Minimum B0-mil TPO Adhered or Mechanically Fastened. VersiFlex PVC and KEE HP Membrane Hail - 1" Dia. Hail Coverage requires a minimum of 60-mil PVC or KEE HP PVC Adhered to cover board. - 2" Dia. Hail Coverage requires BO-mil PVC or KEE HP PVC Adhered to cover board. Additional Design Requirement: - Cover board (SecurShield HD, SecurShield HD Plus, SecurShield HD or DuraFaceR Composite, DensDeck Prime, DensDeck StormX Prime, or Securock - Adhered Only). Puncture - Minimum 60-mil PVC with Polyester Reinforcement Thermoplastics 1/2023 UndertaymenUlnsulation & Required Attachment Assemblies Tabte lX Up to 20 YR Warranty for VersiWeld QA TPO Fulty Adhered Roofing Systems Other Requirements are Listed in Additional Design Considerations following this Table All Versico Products listed for higher wind speed coverage can also be used for Warranties with lower wind speed coverage. (i.e.72 MPH underlayment may be used for 55 MPH underlayment) = Full Spray or Ribbons o.c (1) For Building heights between 51'-100', enhance 12'-wide perimeter with 50% more fasteners and plates' (2) Cover boards must be installed over a min. 1" thick approved Versico lnsulation. (3) 1/2" SecurShield (4) Gravel Surface B Thermoplastics 1/2023 HD limited to 90 mph. 112" SecurShield HD Plus limited to 120 mph. UR - Field @ 6" O.C. i Perimeter @ 4" O.C. lnsulation Attachment Adhesive Ribbon Spacing for 4' x 4'size board Metal Edging #of Fasteners per 4' x 8' board size (1)Field Perimeter Minimum Membrane UnderlaYment Peak Gust Wind Speed Warranty 16 (e)1" (20 psi) Polyisocyanurate 101-112" (20 psi) Polyisocyanurate o2"(20 psi) Polyisocyanurate 1/2" SecurShield HD (3) 1/4" DensDeck Prime or 1/4" Securock 6', (4) VersiTrim Drip Edge or VersiTrim 200 12 12" (4)(5)55 or 72 MPH 2" (1.25lbldensity) lnsulfoam SP* 81/2" DensDeck Prime or 1/2" Securock (2) '161/2" SecurShield HD (3) o1/2" SecurShield HD Plus (3) 62" SecurShield HD Composite 111 -1 1 2" (25-psi) Polyisocyan urate 12" (4X5X6)6" (4X6) 82" (25 -psi) Polyisocyanurate 6" (4X5X6)6" (4X6)162" (1.25 lb/density) lnsulfoam SP** VersiTrim Drip Edge or VersiTrim 200 (1 0) 12" (8)6" (6X7)12 80 MPH 1-112" lnsulfoam HD ComPosite* 121/2" DensDeck Prime or 1/2" Securock (2) 161/2" SecurShield HD (3) or 1-112" (20-psi) SecurShield Polyiso 121/2" SecurShield HD Plus (3) or 112" DuraStorm VSH B1 -1 12" DuraF aceR (OSB/Polyiso) Composite 82" (20-psi) SecurShield Polyiso or 2" SecurShield HD ComPosite 6" (6X7) VersiTrim Drip Edge (1 1 ), VersiTrim 200 (11)(12) or VersiTrim 2000 or 3000. 't6 6" (B)90 MPH 1-112" lnsulfoam HD Composite 5/8" DensDeck Prime or 5/8" DensDeck StormX Prime or 5/8" Securock (2) 1/2" SecurShield HD Plus (3) 1-'l tZ' DuraFaceR (OSB/Polyiso Composite) or 1/2' DuraStorm VSH 2" (2s-psi) SecurShield Polyiso (1) FS VersiTrimDrip Edge (11), VersiTrim 200 (11X12) or VersiTrim 2000 or 3000 16 FSIOO MPH 2" SecurShield HD Composite 16 (5) Steel Decks - Field & Perimeter @ 6" O.C. (6) Cementitious Wood Fiber - Field @ 6" O.C. / Perimeter @ 4" O.C. (7) Smooth BUR - Field @ 6" O.C. / Perimeter @ 4" O.C. (8) Gravel Surface BUR - 4" O.C. (91 Reduced Fastening (1 1 fasteners per 4 x 8 board) is acceptable on Reroof / No Tear off projects with a maximum roof height of 40'. (10) may be fastened with ring shank nails staggered 4" on center. Versico HPV or HPVX Fasteners may also be used fastened 12" on center. (1 1)Versico HPV or HPVX Fasteners must be used to secure VersiTrim Drip Edge or VersiTrim 200 Metal Fascia to perimeter wood nailers. (12) Membrane securement is required at the base of the VersiTrim 200 waterdam. *Maximum warranty available 20 y ear. ** Maximum warranty available 15 year. Additional Design Considerations 1 - Minimum membrane thickness 60-mil VersiWeld QA TPO 2 - Building height shall not exceed 100'* 3 - Local Wind Zone perASCE 7 shall not exceed 130 mph* 4 - Acceptable decking: 224auge or heavier steel, structural concrete, 1-112" wood plank, or 15/32" plywood. 5 - All "T-joints" must be overlaid with appropriate flashing material or Versico "T-Joint" covers. * Projects wirere building height exceeds 100' or wananty wind speed exceeds 100 mph, shall be submitted to Versico for review Thermoplastics 1/2023 17 UnderlaymenUlnsulation & Required Attachment Assemblies Tabte Xl 25 YR OR 30 YR Warranty for VersiWeld QA TPO Fully Adhered Roofing Systems Other Requirements are Listed in Additional Design Considerations following this Table All Versico Products listed for higher wind speed coverage can also be used for Warranties with lower wind speed coverage. (i.e. 72 MPH underlayment may be used for 55 MPH underlayment) FS = Full Spray or Ribbons @ 4" (1) For Building heights between 5'l'-100', enhance coverage offered with this substrate. 12'-wide perimeter with 50% more fasteners and plates. (2) Hail (3) Structural Concrete - Field@ 12" O.C. / Perimeter @ 6" O.C. (4) B0-mph over structural concrete - Field & Perimeter @ 6'O.C. (5) Cementitious Wood Fiber & Wood - FS (6) Bg-mph warranty wind speed coverage over Gypsum Decks- Adhesive Ribbon Spacing shall be @ 4' O.C. (7) Versico HPV or HPVX Fasteners must be used to secure Versico VersiTrim 200 Metal Fascia to perimeter wood nailers (B) Membrane securement is required at the base of the VersiTrim 200 waterdam Additional Design Considerations (25 YR or 30 YR Warranty) 1 - Minimum membrane thickness B0-mil Versiweld QA TPO 2 - Building height shall not exceed 100'* 3 - Local Wind Zone per ASCE 7 shall not exceed 130 mph* 4 - Acceptable decking: 22-gauge or heavier steel, structural concrete, 1-112" wood plank, or 15/32" plywood. 5 - All "T-joints" must be overlaid with appropriate flashing material or Versico "T-Joint" covers. 6- New construction or complete tear-off of existing roofing material' * Projects where building height exceeds 100' or warranty wind speed exceeds 100 mph, shall be submitted to Versico for review lnsulation Attachment Adhesive Ribbon Spacing for 4' x 4' size board #of Fasteners per 4' x 8' board size (1)Field Perimeter Metal Edging Peak Gust Wind Speed Warranty Minimum Membrane Underlayment 1" lo 2" (25 psi) Polyisocyanurate 1/4" DensDeck Prime or 1/4" Securock 6" (3X5)6" (5) VersiTrim Drip Edge or VersiTrim 200 1655 or 72 MPH 1/2" SecurShield HD (2) 201-112" to 2" (25-psi) SecurShield Polyisocyanurate 1/2" DensDeck Prime or 1/2" Securock (2) 16 1/2" SecurShield HD Plus (2) 20 6" (4X5)(6)6" (5)(6) VersiTrim Drip Edse (7), VersiTrim 200 (7XB) or VersiTrim 2000 or 3000 80 MPH 1i2" SecurShield HD (2) 241/2" SecurShield HD (2) 1/2" Securshield HD Plus (2)FS FS VersiTrim Drip Edge (7), VersiTrim 200 (7X8) or VersiTrim 2000 or 3000 20 90 MPH 1/2" DensDeck Prime or1l2" Securock (2) 5/8" DensDeck Prime or 5/8" DensDeck StormX Prime or 5/8" Securock (2) 1-112" DuraFaceR (OSB/Polyiso Composite) or 1/2" DuraStorm VSH (2) 't6 2" SecurShield HD Composite (2) 24 FS FS VersiTrim 2000 or 30001OO MPH 1/2" SecurShield HD Plus (2) Thermoplastics 1/2023 19 Part ll- PRODUCTS 2.01 General The components of this roofing system are to be products of Versico or accepted by Versico as compatible. The installation, performance or integrity of products by others, when selected by the specifier and accepted by Versico, is not the responsibility of Versico and is expressly disclaimed by the Versico warranty. 2.02 Membranes A. VersiWeld Membranes 1. General a. VersiWeld TPO Membrane meets or exceeds the requirements of ASTM D6878-17, standard specification for Thermoplastic Polyolefin Based Sheet Roofing. ln addition to the physical properties listed below, refer to the VersiWeld Membrane Technical Data Bulletin for Cool Roof Rating Council (CRRC) and LEEDTM radiative properties as well as U.S.E.P.A. Toxic Leachate Testing and dynamic puncture resistance. b. When tested in accordance with ASTM C1549, the VersiWeld TPO membrane (white and tan) has an initial reflectance of 0.79 (white) and 0.71(tan) and a 3-year aged reflectance of 0.70 (white) and 0.64 (tan). The material has also been tested for emittance in accordance with ASTM C1371. An initial emittance of 0.90 (wh1e) and 0.86 (tan)and a 3-year aged emittance of 0.86 (white) and 0.87 (tan) were achieved. c. The VersiWeld TPO membrane (white) meets the emittance requirements set forth by the USGBC (US Green Building Council) for their LEED (Leadership in Energy and Environmental Designs) Program. \Men tested in accordance with ASTM E408, an emittance of 0.90 was achieved and an SRI (solar reflectance index) of 99 was calculated using ASTM E1980. 2. VersiWeld 45- or 60-mil thick Reinforced Thermoplastic Polyolefin (TPO) membrane, VersiWeld QA TPO (Quick Applied) 60 or 80-mil thick Reinforced Thermoplastic Polyolefin (TPO) membrane and VersiWeld Plus 80-mil ttriif n6intorced Thermoplastic Polyolefin (TPO) conforms to the following physical properties. VersiWeld QAT TPO (white, tan or gray) membrane is available in 10' wide by 50' or 100' long rolls and VersiWeld Standard / HS membrane available in field sheets in rolls 16', 12' , 10' or 8' wide by 1 00' long. Perimeter membrane sheets are available in widths of 6' (used with 12' and I 0' wide field sheets) or 4' (used with 8' wide field sheets) by 100' long. VersiWeld Membrane is available in white, gray or tan (16' wide VersiWeld Membrane only available in white). Special Color TPO membrane is available in 5 colors (Medium Bronze, Rock Brown, Terra Cotta, Slate Gray and Patina Green) in 60-milfield sheets in rolls 5'or 10'wide by 100'long and 80-milfield sheets in'10' wid6 by 100' long. Special Color TPO is a special order product and may require a lead time. OpTION: 60- or 80-mil, white, VersiWeld TPO (white, tan or gray) reinforced membrane is available with an optional APEEL Protective Film. APEEL Protective Film can be left in place for up to 90 days without affecting the integrity of the film, guarding the TPO membrane's surface from scuffs and dirt accumulation during installation.-Durable and e-sy to remove, APEEL Protective Film improves aesthetics and long-term reflectivity. Available 4', 6', 8', 10'and 12'widths by 100' long rolls. Some sizes and colors of VersiWeld QA TPO with APEEL require a minimum order of 200 squares and 2-3 week lead time. Also available, APEEL 6" Cover Tape, allowing 100% coverage of the TPO surface. APEEL Cover Tape rolls are 1,640 feet long. NOTE: VersiWeld High Slope (HS)(also known as Extra Slope (ES)) and Special Color TPO Membrane is specially formulated with higher fire retardancy to accommodate steep slope roof conditions. Thermoplastics 1/2023 25 PHYSICAL PROPERTY ASTM D6878 Requirement 45-milStd & HS 50-milStd & HS 60-milQA TPO 80-milPlus Tolerance on nominal thickness, % ASTM D751 test method +15. -10 r10 r10 r10 !10 Thickness over scrim, in. (mm) ASTM D6878 optical method, average of 3 areas 0.012 min (0.305) 0.018 typical (o.457) 0.024 typical (0.610) 0.024 typical (0.610) 0.034 typical (0.864) Breaking strength, lbf (kN) ASTM D751 grab method 220 (976 N) min. 225 (1.0) min 320 (1.4) typ. 250 (1.1) min. 360 (1.6) typ. 250 (1.1) min. 360 (1.6) typ. 350 (1.6) min. 425 (1.9) typ. Elongation break of reinforcement, % ASTM D751 grab method 15 min.15 min. 25 tvp.15 min. 25 Vp 15 min. 25 typ 15 min. 25 tYP. Tearing strength, lbf (N) ASTM D751 proc.B8by8in.55 (245) min.55 (245) min. 130 (578) $p. 55 (245) min. 130 (578) typ. 55 (245) min. 130 (578) typ. 55 (245) min. 130 (s78) typ. Brittleness point, "F ('C) ASTM D2137 -40 (-40) max.-40 (-40) max. -50 (-a6) typ. -40 (-40) max. -50 (-ao) typ. -40 (-40) max. - 50 (-46) typ. 40 (-40) max. -50 (- 46) typ. Linear dimensional change, % ASTM D12O4,6 hours at 158'F + 1 max.t 1 max. -0.2 tYP. + 1 max. -0.2 VP. + 0.5 max. -0.2 VP t 1 max. -0.2 tvp. Ozone resistance, no cracks 7X ASTM D1149, 100 pphm, 168 hrs Pass Pass Pass Pass Pass Water absorption resistance, mass 7o ASTM D471 top surface only 166 hours at 158 "F water + 3.0 max.3.0 max. 2.0 tYP' 3.0 max. 2.0 tvp. 4,0 max.2.0 tvp. 3.0 max.2.0 tvp. Factory seam strength, lbf /in. (kN/m) ASTM D751 grab method 66 (290) min 66 (290) min.66 (290) min.66 (290) min.66 (290) min Field seam strength, lbf /in. (kN/m) ASTM D1876 tested in peel No requirement 25 (4.4) min. 50 (8.8) typ. 25 (4.4) min. 60 (10.5) typ. 25 (4.4) min. 60 (10.5) typ. 40 (7.0) min. 70 (12.3) typ. Water vapor permeance, Perms ASTM E96 proc. B No requirement 0.10 max. 0.05 typ. 0,10 max. 0.05 typ. 0.10 max. 0.05 typ. 0.10 max. 0.05 tvp. Puncture resistance, lbf (kN) FTM 101C, method 2031 (see supplemental section) No requirement 250 (1.1) min 325 (1.a) typ 300 (1.3) min. 350 (1.6) typ. 300 ('1.3) min 350 (1.6) typ 400 (1.8) min. 450 (2.0) typ. Properties after heat aging ASTM D573,670 hrs at240"F Breaking strength, % retained Elongation reinl., o/o retained Tearing strength, % retained Weight change, % 90 min. 90 min. 60 min. t 1.0 max. 90 min. 90 min. 60 min. t 1.0 max. 90 min. 90 min. 60 min. +'l .0 max. 90 min. 90 min. 60 min. + 1.0 max. 90 min. 90 min. 60 min. t 1.0 max. Thermoplastics 1/2023 26 2.03 lnsulations/Underlayments A. General 1. Roof insulation thickness must be determined by the thermal value required for each project and may be subject to code approval limitations. On projects where a vapor retarder is used, the specifier must calculate insulation thickness to ensure the temperature at the vapor retarder will not fall below the calculated dew point. 2. Multiple layers of insulation are recommended with all joints staggered between layers. 3. For minimum recommended R-Values, previously published by American Society of Heating and Air- Conditioning Engineers (ASHRAE), consult local building code official for applicable requirements. 4. For lnsulation fastening pattern and densities refer to Versico Applicable Details and Design Reference DR-05- 1 9 "lnsulation Fastening Patterns". 5. When new insulation or cover boards are specified, the use of Versico lnsulation and Versico marketed cover board is required. Any of the Versico lnsulation/Underlayment may be specified subject to design restrictions included with each of the following tables. B. VersicoPolyisocyanurate NOTE: SecurShield HD is listed in Paragraph F below. 1. Versico VersiCore Polyiso - A foam core insulation board covered on both sides with a medium weight fiber- reinforced felt facer meeting ASTM C 1289, Type ll, Class 1, Grade 2 (20 psi) or Grade 3 (25 psi). The product is available in 4'x 8' standard size with a thickness from 1 to 4 inches. 4'x 4'tapered panels are also available. 2. Versico VersiCore NH Polyiso - A foam core insulation board covered on both sides with a glass-reinforced felt meeting ASTM C 1289, Type ll, Class 1, Grade 2 (20 psi) or Grade 3 (25 psi). The product is available in 4' x 4' and 4 x 8' standard size with a thickness from /'" to 4 inches. VersiCore NH Polyiso contains zero halogenated flame retardants. 3. SecurShield Polyisocyanurate- A foam core insulation board covered on both sides with a coasted glass fiber mat facer meeting ASTM C 1289, Type ll, Class 2, Grade 2 (20 psi) or Grade 3 (25 psi). The product is available in 4'x 8' standard size with a thickness from 1 to 4 inches. 4'x 4'tapered panels are also available. These flat board products feature a dark-colored coated-glass facer (CGF) on one side of the insulation board and a light- colored CGF on the other, labeled Ready Flash. Ready Flash Technology allows applicators to manage adhesive Table Bl Polyisocyanurate (See below for product descriptions) lnsulations / Underlayment Minimum Thickness ASTM Roofing System Acceotabilitv Fully Adhered Mechanically Fastened Versico VersiCore Polyiso -1 .5"C1289, Type ll, Class 1, Grade 2 or 3 Versico VersiCore NH Polyiso -1 .5"C1289, Type ll, Class 1. Grade 2 or 3 SecurShield Polyisocyanurate "1 .5"C1289, Type ll Class 2. Grade 2 or 3 SecurShield NH Polyisocyanurate "1 .5"C1289, Type ll Class 2. Grade 2 or 3 HD Polyiso Composite (SS HD)2"C1289, Type lV Grade 2 or 3 DuraFaceR Polyiso Composite (OSB)1.5"289, Type V, 2 -Extended Warranty, those with longer duration, higher wind speed, or puncture coverage, may require the use of a cover board over Polyiso lnsulation, refer to Warranty Tables in Paragraph 1.04 for applicable requirements. -Maximum Flute Spanability shall be limited lo 2-518" when 1" Minimum Polyiso lnsulation is to be used, -Minimum thickness of insulation board may be restricted by wind speed coverage and warranty duration, refer to Tables V and Vl in Paragraph 1.05. "1 .5 minimum toi futty adhered systems. 1" minimum for mechanically attached systems or as a base layer for fully adhered. Notes: N/A = Not Thermoplastics 1i2023 31 flash-off times by choosing between two different-colored facers on every board. SecurShield NH Polyisocyanurate - A foam core insulation board covered on both sides with a coated glass flber mat facer meeting ASTM C 1289, Type ll, Class 2, Grade 2 (20 psi) or Grade 3 (25 psi). The product is available in 4' x 4' and 4' x 8' standard size with a thickness from T' inch to 4 inches. SecurShield NH contains zero halogenated flame retardants. SecurShield HD Gomposite - Composite insulation panel comprised of 1/2-inch high-density (109 psi max) Polyiso cover board laminated during the manufacturing process to SecurShield rigid Polyiso roof insulation meeting ASTM C1289 Type lV, Grade2 (20 psi) or Grade 3 (25 psi). Available in 4'x 8'boards with thickness from 2" to 4.5".4' x 4' panels are also available. 6. DuraFaceR Polyiso Gomposite (OSB) -Polyiso insulation bonded on the bottom side with a medium weight fiber-reinforced felt face and laminated with a top surface of 7116" or 5/8" thick Oriented Strand Board (OSB) meeting ASTM C1289, Type V, Grade 2 (20 psi) or Grade 3 (25 psi). Available in 4' x 8' boards with thickness from 1-112" to 4". C. EPS : Expanded Polystyrene Table Cl EPS rene below for uct lnsulations / Underlayment Minimum Thickness ASTM Adhered Foam I 1"c578 I vilt lnsulFoam ll 75"c578 il N/A lnsulFoam lnsulFoam HD Composite 1.5"C57B Type (1, Vlll, ll, or lX) H Cover 1 c578 1"vilt N/A SP 2" -Local Codes must be consulted regarding the acceptance expanded insulation directly over steel decks. When minimum thickness shall be designated by the manufacturer' -Expanded polystyrene roof insulations cannot be installed directly over coal{ar pitch roof surfaces or existing PVC membranes. A separation layer of minimum 1/2" SecurShield HD, Versico Recovery Board or Polyiso lnsulation shall be used. (1) VersiFlex PVC and KEE HP Membrane is not acceptable for this application. (2) May be used as a substrate for VersiWeld QA TPO membrane Only. (3) Minimum 1.25 lbs/cubic ft (pcf) density required For VersiWeld TPO Membrane (\/wtite Membrane Only) Notes: N/A = Not NOTE: R-Tech Fanfold Recover Board is listed in Paragraph F below. NOTE: lnsulation boards listed in a through d may be specified beneath SecurShield HD, Versico Recovery Board, Dens-Deck Prime, DensDeck StormX Prime or Securock. 2. lnsutFoam I - A closed-cell lightweight expanded polystyrene (EPS) that meets ASTM C578, Type l. Nominal density of 1.0 lbs/cubic ft (pcf) available in 4'x4'or 4'x 8'sizes with thickness from 1/4" to 40". Custom lengths, widths and tapered boards are available. 3. lnsulFoam Vlll - A closed-cell lightweight expanded polystyrene (EPS) that meets ASTM C578, Type Vlll. Nominal density of 1.25 lbs/cubic ft (pcf) available in 4' x 4' or 4' x 8' sizes with thickness lrom Ta" to 40". Custom lengths, widths and tapered boards are available. 4. lnsutFoam ll - A closed-cell lightweight expanded polystyrene (EPS) that meets ASTM C578, Type ll. Nominal density of 1.5 lbs/cubic ft (pcD available in 4'x4' or 4'x 8'sizes with thickness from 1/4" to 40". Custom lengths, widths and tapered boards are available. 5. lnsulFoam lX - A closed-cell lightweight expanded polystyrene (EPS) that meets ASTM C578, Type lX. Nominal density of 2.0 lbs/cubic ft (pcf) available in 4' x 4' ot 4' x 8' sizes with thickness from 1/4" to 40". Custom lengths, widths and tapered boards are available. 6. lnsulFoam HD Composite - lnsulFoam expanded polystyrene (EPS) insulation laminated with a top surface of 112" thick SecurShield HD. Available in 4' x I' boards with thickness from 1-112" lo 7". 7. lnsullam - lnsulFoam expanded polystyrene (EPS) insulation laminated with a top surface of 7116" or 518" Thermoplastics l/2023 32 4. 5. plastic and cellulose fiber sourced from post-industrial and post-consumer waste streams. DuraStorm VSH is a durable, extremely moisture and mold resistant building material with a core that does not disintegrate or delaminate in the presence of water. Available in 1/2" thick and 4'x 8' size board. 7. Versico Recovery Board - A 112" or 1" thick high-density wood fiberboard with an asphalt coated facer for use as a cover boird or recover board. Available 112" or 1" thick and 4'x 4' or 4'x 8' size boards. When used in reroof i no tear-off projects, warranty is limited to 1S-year projects. 8. DensDeck StormX Prime - a reinforced gypsum cover board with an enhanced, moisture-resistant core and coated glass mat facers on the top and bottom side. The top surface is pre-primed and provides excellent bond stfungth for adhered membrane for use as a cover board. DensDeck StormX Prime is extremely durable and is appioved for use in assemblies meeting FM's Very Severe Hail (VSH) Classification. Available in 5/8" thickness and 4'x 4' or 4'x 8'size boards. 5. DensDeck Prime -gypsum core that incorporates glass-mat facings on the top and bottom side. The top surface is pre-primed and provides excellent bond strength for fully adhered membrane for use as a cover board. Available in 114" to 5/8" and 4' x 4' or 4' x 8' size boards. 6. DensDeck Cover Board -gypsum core that incorporates glass-mat facings on the top and bottom side for use as a cover board. Available in 1/4" to 5/8" and 4', x 4', or 4' x 8', size boards. 7. R-Tech FanFold Recover Board - Closed-cell lightweight expanded polystyrene (EPS) with polymeric laminated faces which meets ASTM C 578 for use as a recover board. Polymeric facer compatible with PVC and KEE HP membrane, while metallic side used with EPDM. Available in thicknesses of 3/8" to 3/4" with coverage 4'x 50' (2 squares). 4' x 8' units are also available. 8. Hp protection Mat - A nominal 6-oz per square yard UV resistant polypropylene needle punched fabric used either above the membrane as a slip-sheet for ballast or as an underlayment to the membrane. Available 15' x 300' roll (4500 square foot) weighing 0.06 lbs per square foot. 2.04 Related Materials A. VersiWeld Flashing (for use with VersiWeld Adhered, Mechanically Attached and VersiWeld QA Fully Adhered Membrane Assemblies) j. VersiWeld Flashing: VersiWeld non-reinforced flashing is available in rolls 12" and 24" wide by 50' long. Flashing is used for i-nside/outside corners and field fabricated pipe flashings when the use of pre-molded or pre- fabricated accessories is not feasible. ln addition, 45-mil by 6" wide by 100' long, 60-mil by 6" wide by 100' long, 9" wide by S0' long and 80-mil by 9" wide by 50' long. VersiWeld reinforced membrane is available for overlaying fasteners and fastening plates' Z. VersiWeld Pressure-Sensitive Cover Strip: A nominal 30-mil thick non-reinforced TPO membrane laminated to nominal 30-mil thick cured synthetic rubber pressure-sensitive adhesive used in conjunction with Tl9 Primer or Low-VOC TpO Primer to strip in flat metal fianges (i.e., drip edges). Available in rolls 6" wide by 100' long in colors of white, gray or tan. Not for use on 2S-year or 30-year Warranty projects. 3. VersiWeld TPO Reinforced Overlayment Strip: A heat-weldable, reinforced thermoplastic polyolefin membrane. lt is available in 45-mil 6" x 1 00' and 60-mil 6" x 100' and 9" x 50' rolls in colors of white, gray or tan. It can be used to cover end laps on VersiFleece and QA TPO systems and to strip in flat metal flanges on details such as TPO coated drip edges, gravel stops, and scuppers. 4. APEEL Cover Tape: A 6"-wide, 1,640' long roll of APEEL Protective Film used to protect areas of VersiWeld TpO or VersiFtex pVClXf f HP membrane where APEEL Protective Film has been removed (around details) or was not factory applied (seams). APEEL Cover Tape allows contractors to keep '100 percent of the TPO or pVC/KEE Hp iurface clean during installation and is applied using the APEEL Cover Tape Applicator. VersiWeld TPO Pressure-sensitive RUSS: A nominal 6" and 10" wide, 45-mil thick reinforced TPO membrane with nominal 3" wide 35-mil thick cured synthetic rubber pressure-sensitive adhesive laminated along one e_nd on 6" wide RUSS and along both ends on 10" wide RUSS. Used in conjunction with TPO Primer or Low-VOC TpO primer. 6" wide nUSS is used as a base membrane securement along walls, curbs, etc.; 10" wide RUSS is used to form perimeter sheets on Mechanically Attached Systems' VersiWeld TPO TJoint Covers: A 60-mil thick injection molded TPO flashing formed into a 4.5" diameter circle used to seal step-offs at splice intersections. lnstallation is mandatory on all 60-, 72-, and 80-mil TPO systems and on 45-mil systems where step-offs have not been properly sealed. Packaged in boxes of 100. Available in white, tan or gray. yellow Pressure-sensitive (PS) Warning Strip: A nominal 30-mil-thick non-reinforced TPO flashing laminated 5. 6. 7 Thermoplastics 1/2023 35 to a nominal 30-mil-thick, fully cured synthetic rubber Pressure-Sensitive adhesive and is available in 6" wide by 100' long rolls. Yellow Pressure-Sensitive Warning Strip can be applied to EPDM, TPO or Hypalon roofing systems to provide a visual warning of an impending hazard (i.e. roof edge, deep drain sump, skylight). 8. VersiWeld TPO Rib Profile: Used to obtain the appearance of standing seam metal roofing with the performance of a TPO single-ply membrane. The Rib Profile measures 1-114" tall and '1-3/4" wide, including the welding flanges, while the vertical profile is a substantial 3/8" thick. The profile has a continuous 1/8" diameter alignment hole, for use with fiberglass connecting pins, as well as a 'l18" fiberglass reinforcing cord for added strength. The Rib Profile is available in white, gray and tan, as well as Special Colors (Medium Bronze, Rock Brown, terra Cotta, Slate Gray and Patina Green) in 10' lengths and packaged 20 per carton. 9. Pre-MoldedAccessories: a) lnside Corners: A pre-molded corner flashing for inside corners. Available in white, gray or tan; 60-mil thick. b) Outside Corners: A one-piece injection molded corner flashing used for flashing outside corners. Available in white, gray or tan; 60-mil thick. c) TPO Gurb Wrap Gorners: Fabricated flashings are made of 60-mil thick reinforced VersiWeld membrane designed to reduce installation time to flash a curb when compared to conventional methods. Each corner is fabricated with a 6" wide base flange and a 12" overall height. Four sizes are available to fit curbs up to 6' by 6' in size. One curb requires 4 corners for a complete installation. TPO Curb Corners are packaged in boxes containing twelve corners. Custom sizes are available as a special order product requiring lead time. d) TPO Universal Corners: a pre-molded flashing for use in a variety of corner details, including inside and outside corners. Available in white, gray and tan and are 60-mil thick. Sipe Flashings: A pre-molded white, gray or tan pipe flashing used for pipe penetrations. Available for 3/4" -8" diameter pipes with clamping rings included. Split Pipe Seals: A prefabricated flashing consisting of 60-mil thick reinforced VersiWeld Detail Membrane for pipes 1" - 6" in diameter. A split (cut) and overlapped tab are incorporated to allow the pipe seal to be opened and wrapped around the pipe when it is not possible to pull a standard pipe flashing over a round penetration. Custom sizes are available as a special order product requiring lead time. TPO Square Tubing Wraps: Fabricated flashings made of 60-mil thick reinforced VersiWeld Detail membrane for square tubing. A split (cut) and overlap tab are incorporated into these parts to allow the seals to be opened and wrapped around a square penetration. Available for 3", 4", 5" and 6" square tubing Molded TPO Sealant Pockets: A pre-fabricated, interlocking, 2-piece, injection molded, flexible pocket with a rigid polypropylene vertical wall and pre-formed deck flanges. Pockets can be adjusted from 11.5" to 7.5" in length by 6' in width by following the cutting lines molded into the pocket. Used in conjunction with White One-Part Pourable Sealer for waterproofing pipe clusters or other odd shaped penetrations. Available in white, gray or tan. Pre-fabricated Sealant Pockets: A two-piece, pre-fabricated sealant pocket that utilizes reinforced 60-mil TPO membrane and coated metal to form a rigid, oversized sealant pocket with a weldable horizontal deck 1ange. Available in 12" (total volume oI 1.87 gallons). Packaged 2 per carton and available in white only. Refer to the applicable Technical Data Bulletin for dimensions and installation instructions. Custom sizes are available as special order products. Sealant Pocket Extension Legs: Designed for use with the TPO Molded Sealant Pocket and the Pre- Fabricated Sealant Pocket to extend the length in increments of '10". Fabricated from 45-mil thick reinforced TPO membrane and TPO coated metal. Can be used full length, cut to size for customized lengths or welded to each other for extra-long applications. Packaged 10 legs per carton and available in white only. B. VersiFlex Flashing (for use with VersiFlex PVC, VersiFlex FRS PVC and VersiFlex KEE HP Membrane Assemblies) 1. VersiFlex PVC non-reinforced Flashing (white, gray, light gray, slate gray and tan) is 60-mil thick and available in rolls 12" and 24" wide by 50' long. Flashing is used for inside/outside corners and field fabricated pipe flashings when use of pre-molded accessories is not feasible. 2. VersiFlex PVG Reinforced Cover Strip: A 8" wide, nominal 80-mil thick, polyester reinforced PVC membrane. Used for stripping in rows of fasteners and plates and covering the butt joints of VersiFlex PVC membranes. Available in rolls 8" wide by 75' long in colors of white, gray or tan' Thermoplastics 1/2023 36 J"i f) s) h) i) i) 5. 6. 7 3 4. 8. I VersiFlex KEE HP Reinforced Gover Strip: A 8" wide, nominal 80-mil thick, polyester reinforced KEE HP PVC membrane. Used for stripping in rows of fasteners and plates and covering the butt joints of VersiFlex KEE HP PVC membranes. Available in rolls 8" wide by 75' long in colors of white, gray or tan, also available in 60-mil in rolls of 8" wide by '100' long in white only. VersiFlex PVG Pressure-sensitive Gover Strip: A 6" wide, nominal 35-mil thick non-reinforced KEE HP 1ashing laminated to a nominal 35-mil, fully cured, pressure-sensr{v9, synthetic rubber adhesive. Used for strippin-g in flat metal edgings (i.e. drip edge) of VersiFlex PVC and KEE HP PVC membranes. Available in rolls O', riviOe'Oy 100' tong in c6tois ot wfrite, gray or tan. Used in conjunction with PVC Step 1 Activator and PVC Step 2 Primer. VersiFlex PVC Overlayment Strip: An 80-mil non-reinforced thermoplastic polyvinyl chloride-based membrane used for stripping in pVC Coated Metal roof edging. VersiFlex PVC Overlayment Strip is av_ailable in 6" x 100' rolls with a white top side and gray or tan bottom side to match white and gray VersiFlex PVC membranes. VersiFlex PVC "T" Joint Gover: A 4-112" diameter, 60-mil thick (white) or 40-mil (gray or tan), pre-cut non- reinforced PVC flashing used to overlay "T" joints at field splices when 60-mil or 80-mil VersiFlex PVC or VersiFlex KEE HP membrane is used. APEEL Cover Tape: A 6"-wide, 1,640' long roll of APEEL Protective Film used to protect areas of VersiWeld TpO orVersiFlex PVC/KEE HP membrane where APEEL Protective Film has been removed (around details) or was not factory applied (seams). APEEL Cover Tape allows contractors to keep 100 percent of the TPO or pVC/KEE Hp durfbbe clean during installation and is applied using the APEEL Cover Tape Applicator. VersiFlex PVC Yellow Pressure-Sensitive Warning Strip: a nominal 30-mil-thick, non-reinforced membrane flashing laminated to a nominal 30-milthick, fully cured, synthetic_rubber, pressure-sensitive adhesive and is availab]e in 6"-wide by 100'-long rolls. Pressure-Sensitive Warning Strip can be applied to VersiFlex PVC or KEE Hp systems to proviile a visual warning of an impending hazard (e.9., roof edge, deep drain sump, skylight' etc.). VersiFlex PVC Rib Profile: Used to obtain the appearance of standing seam metal roofing with the performance of a pVC single-ply membrane. The Rib Profile measures 1-114" tall and 2-118" wide, including the welding flanges, while-the v'ertical profile is a substantial 3i8" thick. The profile has a continuous '118" diameter alignment hole: for use with fiberglass connecting pins, as well as a 1/S" fiberglass reinforcing cord for added strength The Rib profile is available in white, gray, iight gray, slate gray and tan, 10' lengths and packaged 20 per carton. 10. Pre-Molded Accessories a) VersiFlex PVG lnside Gorners: A pre-molded flashing for inside corners. Available in white or gray on tan' 60-milthick. b) c) VersiFlex PVG Outside Corners: A pre-molded flashing for outside corners. Available in white, gray or tan; 60-mil thick. VersiFlex pVG Curb Wrap Corners: Fabricated flashings are made of 60-mil thick reinforced VersiFlex KEE Hp pVC Detail membrane designed to reduce installation time to flash a curb when compared to conventional methods. Each corner is fabricated with a 6" wide base flange and a 12" overall height. Three sizes are available to fit curbs up to 3' by 3' in size. One curb requires 4 corners for a complete installation. pVC Curb Wrap Corners are packaged in boxes containing twelve corners. Custom sizes are available as a special order product requiring lead time. pVC Universal Gorners: a pre-molded flashing for use in a variety of corner details, including inside and outside corners. Available in white and are 60-mil thick. VersiFlex pVG Pipe Flashings: A pre-molded pipe flashing used for pipe penetrations. Available in white, gray or tan, for 314" - 8" diameter pipes with clamping rings included. VersiFlex PVC Split Pipe Seals: A prefabricated flashing consisting of 60-mil thick reinforced VersiFlex Membrane for pipes 1" - 6" in diameter. A split (cut) and overlapped tab are incorporated to allow the pipe seal to be opened and wrapped around the pipe when it is not possible to pull a standard pipe flashing over a round penetration. Available in white, gray or tan' VersiFlex pVC Square Tubing Wraps: Fabricated flashings made of 60-mil thick reinforced VersiFlex membrane for square tubing. A split (cut) and overlap tab are incorporated into these parts to allow the seals to be opened and wrapped around a square penetration. Available for 3", 4" and 6" diameter square tubing. Available in white and gray. d) e) D s) Thermoplastics 1/2023 37 c. h) VersiFlex PVG Molded Sealant Pockets: A pre-fabricated, interlocking, 2-piece, injection molded, flexible pocket with a rigid PVC vertical wall and pre-formed deck flanges. Used in conjunction with White One-Part Fourable Sealer for waterproofing pipe clusters or other odd shaped penetrations. Pockets can be adjusted from 11.5" to 7.5" in length by 6" in width by following the cutting lines molded in the pocket. Available in white only. Primers, Adhesives, Sealants and Cleaners Refer to Technical Data Bulletins for material coverage rates and proper usage. Prior to the use of any of the products listed below, consult the Safety Data Sheets for applicable cautions and warnings 1. VersiWeld Products , a) Ve6iylbtd,€ondirggAdhesive: A high-strength, synthetic rubber adhesive used for bonding VersiWeld membrane to various surfaces. The adhesive is applied to both the membrane and the substrate at a coverage rate of approximately 60 square feet per gallon per finished surface (includes coverage on both surfaces). b) Low-VOG Bonding Adhesive for TPO: This product meets the <250 gpl VOC (volatile organic compound) content requirements of the OTC Model Rule for Single-Ply Roofing Adhesives. A high strength, solvent- based contact adhesive that allows bonding of TPO membrane to various porous and non-porous substrates. Apply at a rate of 60 ft2 per gallon finished surface. Available in 5 gallon pails. This product does not comply with certain counties in the State of California which have additional restrictions on solvents. c) Low-VOG Bonding Adhesive 1168: This product meet! the <250 gpl VOC (volatile organic compound) content requiremenls of the OTC Model Rule for Single Ply Roofing Adhesives. A high strength, solvent- based contact adhesive that allows bonding of TPO membrane to various porous and non-porous substrates. Apply at a rate of 60 ft2 per gallon finished surface. Available in S-gallon cans. This product complies wlttr all counties in the State of Galifornia which have additional restrictions on solvents. d) Aqua Base 120 Bonding Adhesive: A semi pressure-sensitive, water based adhesive used as a two- sided contact adhesive. Coverage rate is 120 square feet per gallon finished surface (applied to membrane and substrate). Refer to Spec Supplement G-09-18 "Aqua Base 120 Bonding Adhesive" for Warranty limitations and other considerations. e) CAV-GRIP 3V Low-VOG Aerosol Contact Adhesive/Primer: a low-VOC, spray;app!9d aerosol contact adhesive and primer used for a variety of applications: adhering standard VersiWeld TPO and VersiGard EpDM membranes to horizontal and vertical surfaces, adhering VersiFleece membranes to vertical surfaces, as a primer for VapAir Seal 725TR, and as an unexposed asphalt primer for Flexible DASH for insulation attachment. f) Gut-Edge Sealant: A clear colored sealant used to seal cut edges of reinforced. VersiWeld membrane. A' coverag! rate of approximately 225 - 275 linear feet per squeeze bottle can be achieved when a 1/8" diameter bead is aPPlied. S) Water Cut-Off Mastic: Used as a mastic to prevent moisture migration at drains, compression terminations and beneath conventional metal edging (at a coverage rate of approximately 10' per tube or 100' per gallon). h) Universal Single-Ply Sealant: A 100% solids, solvent free, VOCJree, one part polyether sealant that provides a wea--ther tignt seat to a variety of building materials. lt is white or gray in color and is used for general caulking such as above termination bars and metal counter flashings and at scuppers. i) White One-Part Pourable Sealer: A one-part, moisture gulng, elastomeric polyether sealant used to fill Molded pourable Sealant Pockets. Packaged in 4, 2-liter foil pouches inside a reusable plastic bucket. 1 pouch will fill 122 cubic inches of volume within a sealant pocket. j) Weathered Membrane Gleaner: Used to prepare TPO membrane for heat welding that has been exposed to the elements or to remove general construction dirt at an approximate coverage rate of 400 square feet per gallon (one surface). k) TpO Primer: A solvent-based primer used to prepare the surface of VersiWeld Membrane prior to application of Pressure-sensitive Coverstrip and TPO Pressure-Sensitive RUSS. l) TpO Low-VOG Primer: A solvent-based, low solids primer used to prepare the surface of VersiWeld Membrane prior to application of Pressure-Sensitive Coverstrip and TPO Pressure-Sensitive RUSS. This Low-VOC product is ideal for use in states where environmental issues are a concern. Thermoplastics 1/2023 3B conjunction with Seam Fastening Plates below the VersiWeld TPO deck membrane for additional membrane securement. Available in rolls 100' long, 2 per carton. b) 10" wide Quick-Applied RUSS is utilized for perimeter membrane securement along the center of field sheets to form perimeter membranes. Available in rolls 100' long, 1 per carton. Fasteners The following Table illustrates criteria for fastening of Versico Insulation with the referenced roof deck and includes minimum penetration requirements and pilot hole criteria. lnsulation Fastenin Criteria Notes: N/A = Not Applicable (1) For Fully Adhered Systems, only 3" diameter insulation fastening plates can be used for insulation attachment. (2) The pilot hole must be predrilled to a sufficient depth to prevent contact between the fastener point and any accumulated dust in the predrilled hole. This will help prevent bottoming out of the fastener during installation. (3) For wood planks only, fastener penetration shall not exceed 1-1l2". i+i fVf ost cementitious wood fiber decks do not require pre-drilling; however, Versico should be contacted prior to installation for verification of specific types that may require a pilot hole to be predrilled. (5) Pilot hole size may be varied to maximize pullout resistance. All Fasteners listed below can be used with VersiWeld or VersiFlex Roofing Systems. Refer to the applicable specification for specific requirements. 1. HpVX Fastener: A freavy duty #15 threaded fastener with a #3 Phillips drive used with Versico's HPVX .-\ Fastening Plate to secure Mechanically Attached Roofing Systems. lt is used on minimum 22 gauge steel decks performance, back-out and corrosion resistance with excellent pullout performance. 2. HpV-XL Fastener: An oversized diameter #22(.315") steel, threaded fastener used in conjunction with HPV- XL plates for membrane securement into minimum 22 gauge steel or wood decks on Mechanically Attached Roofing Systems. 3. HpV Fastener: A threaded E-coat square head fastener for insulation attachment only. Used into steel, wood plank, minimum 15i32" thick plywood or minimum 7/16" thick oriented strand board (OSB). 4. pre-Assembled lnsulTite ASAP Fastener: Versico's lnsulTite Fastener pre-assembled with a 3" diameter plastic plate used for insulation attachment only on Fully Adhered and Mechanically Attached Roofing Systems. lnstalled using Olympic Fasteners' Fastening Tool. 5. lnsulTite Fastener: A threaded Phillips drive fastener used with Versico lnsulation Plates for insulation attachment to steel or wood decks. 6. CD-10 Fastener: A hammer-driven, non-threaded E-Coat fastener for use with structural concrete decks rated 3,000 Psi or greater. 7. Mp 14-10 Concrete Fastener: A #14 threaded fastener with a #3 Phillips drive used for minimum 3,000 psi concrete decks. Thermoplastics 1i2023 40 B Pilot Hole Depth Pilot Hole Diameter Versico Fasteners (1) Min. PenetrationDeck Type N/A314N/AASAP or lnsulTiteSteel or Lightweight lnsulating Concrete over Steel 7t32"1"Note (2)CD-10 3/16"1"Note (2)MP 14-10 Structural Concrete, rated 3,000 psi or oreater N/A N/AHPV, ASAP OT lnsulTite Min. 1" (3)Wood Plank, min. 15/32" thick Plvwood or min. 7/16" OSB N/A1-1t2"Note (4)Polymer Gyptec or Lite-Deck FastenerCementitious Wood Fiber Note (2)7t16",112" or 9/16" (5)1-1t2"Polymer Gyptec or Lite-Deck FastenerGypsum 8. Polymer Gyptec Fastener: A glass-filled nylon auger fastener designed for securing insulation and/or membrane to specialty decks such as cement wood fiber or gypsum. g. Lite-Deck Fastener: A deep, coarse threaded fastener used to secure insulation to gypsum and cementitious wood fiber decks in conjunction with Lite-Deck Plates. C. Fastening Plates 1. HPVX Plate: A2-318" diameter metal barbed fastening plate used with Versico HPVX CD-'l0 or MP 14-10 Fasteners for membrane or insulation securement. This plate can be used for membrane or insulation securement on Mechanically Attached Roofing Systems. 2. HpV-XL Plate: A 2-318" diameter metal barbed fastening plate with an oversized hole for use with Versico HPV- XL Fasteners for membrane securement on Mechanically Attached Roofing Systems. 3. Seam Fastening Plate; A 2" diameter metal plate used for insulation attachment on Mechanically Attached Systems or membrane securement at angle changes on Fully Adhered Systems in conjunction with the appropriate Versico Fastener. 4. Insulation Fastening Plate: A nominal 3-inch metal plate used for insulation attachment in conjunction with the appropriate Versico Fastener. S. SecurFast Insulation Fastening Plates: A nominal 2-718" hexagon metal plate used for insulation attachment in conjunction with the appropriate Carlisle Fastener. 6. Accutrac lnsulation Plates: A nominal 3" square, recessed or flat bottomed, metal plate used for insulation attachment in conjunction with the appropriate Carlisle Fastener. Flat bottom plate is used with manufactured Philips Head fasteners onlY. 7. Oval plate: A2-3t4" x 1-112" oval metal barbed fastening plate for use with Versico HPVX fasteners for securement of 10'wide PVC and KEE HP membranes on Mechanically Attached Roofing Systems. 2.06 lnsulation Securement Adhesive 1. Flexible DASH Adhesive: A two-component (Part A and B), low-rise polyurethane adhesive designed for bonding VersiFleece membrane and/or insulation to various substrates. Coverage rates can b,e_ found in paragriph 3.0S'Membrane Placement and Securement'. Flexible DASH Adhesive is packaged in 50- and 15- galloi drums, as well as, S-gallon Jug and Dual Cartridges that can be applied in full spray or extrusion, depending on disPensing tYPe. 2. Flexible DASH Dual Tank: A two component (Part A and B), extrusion applied, low rise adhesive for bonding insula1on to various surfaces. DASH Dual Tanks utilize an HFO blowing agent. HFO (hydrofluoroolefin) blowing agents are widely recognized as the next-generation environmentally friendly blowing agent, replacing their HFC (h-ydrofluorocarbon) predecessor. When extruded al 12" on center the coverage rate is 3,500 to 3,700 sq.ft. per set of Dual Tanks. 3. Flexible DASH Dual Cartridge and S-gallon Jug Adhesive: A two component (Part A and B), extrusion applied, low rise adhesive foibonding insulation to various surfaces. When extruded at 12" on center the coverage rate is 400-600 sq.ft. per carton of Dual Cartridges or 2,000-2,500 sq.ft. per set of S-gallon Jug Adhesive. 4. OlyBond S00 Bag in a Box - A two-component, polyurethane, low-rise expanding adhesive used to bond insulation to varioul substrates. Packaged in S-gallon boxes of Part A and Part B formulations that are applied using a mechanical dispenser system. Applied in 112" lo 3/4" beads or ribbons at the rate of 1 gallon per 150- 250 iquare feet for 12" o.c. bead spacing. Perimeter bead spacing patterns and acceptable insulation and deck types are listed in the applicable Product Data Sheet. 5. OlyBond 500 BA Spot Shot - A two-component, polyurethane construction grade, low-rising.expanding adhesive designed foi bonding insulation to various substrates. Applied in 112" to 3/4" beads or ribbons using a portable 1.'1 applicator (oveisized, dual-cartridge caulking gun). Refer to the Product Data Sheet for bead spacing with reference to building height 2.07 Vapor / Air Barrier 'l . General Thermoplastics 1/2023 41 lf insulation is to be fully adhered to the vapor retarder with Flexible DASH Adhesive, the vapor retarder must be compatible and shall be fully adhered to the substrate. Available products include Versico 725 Air and Vapor Barrier and spray or roller applied butyl coatings. lnstallation requirements for Versico's VapAir Seal 725TR Air and Vapor Barrier are identified in Spec Supplement G-O7-20 "Application Procedures for 725TR Air and Vapor Barrier" and Versico's VapAir Seal MD Air and Vapor Barrier are identified in Spec Supplement G-12-19 "Application Procedures for VapAir Seal MD air and Vapor Barrie/' in the Versico Technical Manual. Versico VapAir Seal 725TR Air and Vapor Barrier - A 40-mil thick composite consisting of 35-mil self-adhering rubberized asphalt membrane laminated to an 5-mil UV resistant poly film with an anti-skid surface which is fully compatible with Flexible DASH Adhesive. 725TR can also function as a temporary roof for up to 120 days. Available in rolls 39" wide by 100' long (325 square feet). Versico VapAir Seal MD Air and Vapor Barrier - a reinforced composite aluminum foil with self-adhesive SBS backing and removable poly release film. Used for direct application over metal decks. Used for direct application over metal decks. Available in rolls 42.5" wide by 131.23" long (460 square feet). 4. CAV-GRIP 3V Low-VOC Aerosol Contact Adhesive/Primer: a low-VOC, methylene chloride-free adhesive that can be used for a variety of applications including. enhancing the bond between Versico's VapAir Seal 725TR and various substrates. Coverage rate is approximately 2,000-2,500 sq. ft. per 40 lb cylinder and 4,000- 5,000 sq. ft. per 85 lb cylinder as a primer, in a single-sided application. 5. CCW-702 Primer and 702LV Primer (Low-VOG) - A single component, solvent based, hightack primer used to provide maximum adhesion between Versico 725TR Air and Vapor Barrier and an approved substrate. Applied by spray or long nap roller with a coverage rating ranging from approximately 300 to 350 square feet per gallon on smooth finishes (i.e., concrete) to 75 square feet per gallon on porous surfaces (i.e., Dens-Deck Prim-e gypsum board). Available in S-gallon containers. CCW-702LV Primer contains less than 250gil VOCs and meets South Coast Air Quality Management District (SCAOMD) and Leadership in Energy and Environmental Design (LEED) Requirements for Volatile Organic Compounds. 6. CGW-702WE| - a hightack, water-based contact adhesive for promoting adhesion of Versico airlvapor barrier membranes and an approved substrate (i.e., concrete, Dens-Deck Prime and Securock). Applied by roller, brush or spray with an application rate of approximately 200 sq. ft. per gallon. Available in S-gallon containers. CCW-702W8 Primer contains 579/L VOCs and meets South Coast Air Quality Management District (SCAOMD) and Leadership in Energy and Environmental Design (LEED) Requirements for Volatile Organic Compounds. 2.08 Metal Accessories, Edgings, Coping and Terminations A. General Products listed below can be used with any of the available Versico Roofing Systems. Refer to the applicable Versico details and installation instruction manuals for specific installation criteria. B. Products 1. VersiWeld TPO Goated Metal: A 24 gauge, galvanized steel sheet coated with a layer of 40-mil non- reinforced VersiWeld Flashing. The sheet is cut to the appropriate width and used to fabricate metal drip edges or other roof perimeter edging profiles. VersiWeld Membrane may be heat welded directly to the coated metal. Coated metal is available in sheets 4'x 1O'and comes packaged 25 sheets per pallet (also available packaged 10 sheets per pallet on a direct ship basis). Available in white, g1ay or tan. Also available in TPO Special Colors (Medium Bronze, Rock Brown, Terra Cotta, Slate Gray and Patina Green) and comes packaged 5 sheets per pallet on a direct ship basis. 2. VersiFlex PVG Coated Metal: A 24 gauge, galvanized steel sheet coated with a layer of 40-mil non-reinforced VersiFlex Flashing. The sheet is cut to the appropriate width and used to fabricate metal drip edges or other roof perimeter edging profiles. VersiFlex Membrane may be heat welded directly to the coated metal. Coated metal is availablsin sheets 4'x 10' and comes packaged 10 sheets per pallet. Available in white, gray, light gray, slate gray and tan. 3. VersiTrim 200/300 Drip Edge: Pre-fabricated TPO or PVC-coated metal edging. Heat-weld membrane directly to edge. Available in sizes up to 8" fascia height and in colors: white, gray or tan. 4. VersiTrim 200 Fascia: A snap-on edge system consisting of a24 gauge galvanized metal water dam and 40, 50 or 63-mil thick aluminum Kynar 500, clear and colored anodized finish or 22 or 24 gauge steel, Kynar 500 finish. The fascia is available in a variety of colors and heights varying from 5" to 12-112". Custom fascias and colors are available upon request. ANSI/SPRI ES-1 certified. 2. 3. Thermoplastics'1/2023 42 5. VersiTrim 2000 Standard Fascia: An anchor bar roof edge fascia system consisting of heavy .100" thick extruded aluminum bar, corrosion resistant stainless steel fasteners and snap-on fascia cover used with Fully Adhered, Mechanically Attached assemblies. Refer to installation instructions for various sizes, colors and accessories ANSI/SPRI ES-1 certified. Also available in VersiTrim 2000 Extended Fascia (Up to 13" Face Height) and VersiTrim 2000 Canted Fascia. 6. VersiTrim 3000 Roof Edge System: A metal anchor bar fascia system consisting of a 20 gauge steel retainer bar, corrosion resistant fasteners and a 32,40, 50 or 63-mil thick aluminum or 24 gauge steel snap-on fascia cover. lt is for use in Fully Adhered and Mechanically Attached Roofing Systems. ANSI/SPRI ES-'l certified. Also available in VersiTrim 3000XT Roof Edge System (Up to 13" Face Height). 7 . Termination Bar: A '1" wide and 98-mil thick extruded aluminum bar pre-punched 6" on center which incorporates a sealant ledge to support Lap Sealant and provide increased stability for membrane terminations. 8. VersiTrim Term Bar Fascia: A 1.75' wide formed aluminum termination bar with pre-slotted fastening holes for ease of locating and installing. The decorative cover is available in 0.040" aluminum or 24-gauge galvanized steel. VersiTrim Term Bar Fascia is manufacturedin 12' lengths for fewer joints/seams, fewer sections to handle and faster installation. g. Refer to Spec Supplement P-01-20 "Related Products" for other edgings and coping materials. 2.09 Roof Walkways Walkways are to be specified at all traffic concentration points (i.e., roof hatches, access doors, rooftop ladders, etc.), and if regular maintenance, once a month or more, is necessary to service rooftop equipment. 1. Walkway Types VersiWeld Heat Weldable Walkway Rolls; Designed to protect VersiWeld membrane in those areas exposed to repetitive foot traffic or other hazards. Walkway material may be heat welded to VersiWeld membrane uslng an automated heat welder or hand held heat welder. The diamond plate tread pattern offers superior slip resistance. The walk edges are trimmed in safety yellow to better define the designated traffic flow. Walkway Rolls are 34" wide by 50' long and are nominal '180 mils thick. Available in white, tan or gray with safety yellow welding tabs along both edges. NOTE: As an option, walkway rolls may be fully adhered to the membrane surface with QA Seam TapeffPO Primer. VersiFlex PVC Heat Weldable Walkway Rolls: Manufactured from specially compounded PVC, offering superior tear, puncture and weather resistance. Designed to protect VersiFlex (PVC/KEE HP) membranes in ihose areas exposed to repetitive foot traffic or other hazards. Walkway material may be heat welded to VersiFlex (PVC/KEE HP) membranes using an automated heat welder or hand held heat welder. Walkway Rolls are 36" wide by 60' long and are nominal ''l 1O-mils thick. Available in gray only. VersiWeld TPO Crossgrip Walkway Rolls: Manufactured from TPO and may be used in lieu of standard VersiWeld TPO Walkway Rolls when a walkway is to be loose-laid and not secured to the membrane. Loose-laid Crossgrip tpd Watkway Rolls are effective for winds up to 55 mph. Rolls are 36" wide by 33' long, available in white, gray and yellow. VersiFlex PVC Grossgrip Walkway Rolls: Manufactured from PVC and may be used in lieu of standard VersiFlex PVC Walkway Rolls when a walkway is to be loose-laid and not secured to the membrane. Loose- laid Crossgrip PVC Walkway Rolls are effective for winds up to 55 mph. Rolls are 36" wide by 33' long, available in white, gray and yellow. Versico lnterlocking Rubber Pavers 24" X24" X2" thick rubber paverweighing approximately 24 pounds per unit, 6 pounds p-er square foot manufactured from recycled rubber, which provides a resilient, shock aOsorbing, weather.resistant surface. Designed primarily for use as a walkway or on terrace areas offering a uniquelenvironmentally sound advantage over concrete pavers. Features include freezelthaw stability, bi-directional drainage and no breakage concerns. Available in black and terra cotta. Hanover Ballast and Lightweight Ballast Pavers: The standard,24" x24" x 1-13116" thick, Ballast Paver comes in a natural color and a non-slip Diamond finish and weighs 22 lbs/sq. ft. The Lightweighl,23-112" x Z3-1t2" x 1-114" thick, Ballast Paver comes in a natural color and a non-slip diamond finish and weighs 15 lbs/sq. ft. Both pavers can be used as ballast or walkways. a) b) c) d) e) 0 Thermoplastics 1/2023 43 Roof Deck & Substrate Criteria Notes: (1) Local codes must be consulted regarding thermal barrier requirements. (2) Mechanically Attached Systems cannot be specified on steel decks less lhan 22 gauge or for corrugated steel decks, regardleis of gauge. Refer to the Metal Retrofit Roofing System Specification, published separately, for installation options. (3) Loose gravel must be removed to avoid entrapment of moisture- (a) Existing coal tar could drip back into the building, especially when new insulation does not provide sufficient thermal value to prevent the surface of the coal tar from softening. (5) Maximum Warranty Duration of 15 Years with 55 MPH peak gust wind speed. Versico may be contacted for other warranty options. (6) An dppioved underlayment is required over existing ballasted (ballast removed) single-ply systems and PVC roofing systems of any type. (7) Diieci applicaiion permitted over smooth surfaced modified bitumen. To reduce the probability of cold welds, membrane shall be positioned with length of sheets parallel to modified bitumen field seams. At end laps or other locations where splices intersect modified bitumen field seams, 6" wide VersiWeld or VersiFlex Flashing must be heat welded over intersections. (B) Existing Type lll or lV smooth asphalt BUR Only. (9) Possible staining/discoloration of the membrane may result when installing this system directly over existing smooth surfaced BUR or modified bitumen. lf aesthetics are critical, an approved insulation should be specified beneath the membrane. (i 0) New approved cellular lightweight insulating concrete must have a minimum compressive strength of 200 psi. Except when the lightweight concrete is poured over slotted steel decks, pressure relief vents must be installed every 2,000 square feet. Direct application is not permitted where lightweight concrete is poured over an existing roofing material. Equilibrium moisture content after hydration/curing shall not exceed 12%. (1 1) Maximum warranty available 20 YR with 55 MPH peak gust wind speed coverage. Versico may be contacted for other warranty options. TPO Membrane Acceptable Roof DecUSubstrate PVC / KEE HP Membrane Fully Adhered Mechanically Attached NEW CONSTRUCTION Mechanically Attached Fully Adhered lnsulation lnsulation Steel (min. 22 gauge)(1)(2), Wood Plank (3/4" min.), or Fibrous Cement lnsulation lnsulation Direct Application lnsulation Structural Concrete (min. 3000 osi ) or Gvpsum lnsulation Direct Application Direct Application(5) Direct Application(5) Plywood (min. 15/32" thick) or Oriented Strand Board (min. 7/16" thick) Direct Application(5) Direct Application(5) Direct Application 15)(10) Direct ADolication(5)Lightweight lnsulating Concrete lnsulation Direct Aonlication(51{10) Fully Adhered Mechanically Attached RETROFIT' NO TEAR-OFF Mechanically Attached Fully Adhered Direct Application (ex11) Direct Application (ex11) Existing Smooth Surface BUR (8) or Mineral Surface Cap Sheet lnsulation lnsulation lnsulation lnsulation Gravel Surfaced BUR (3)(a) or Coal Tar Pitch (3X4)lnsulation lnsulation Direct Application (7)(9) Direct Application (7x9)Modified Bitumen (11)lnsulation lnsulation lnsulation Direct Application (6)Existing Single-Ply (1 1) Direct Application (6) lnsulation Complete Tear-off Required Complete Tear-off Required Sprayed-in-place Urethane Complete Tear-off Required Complete Fear-otf Required Fully Adhered Mechanically Attached RETROFIT I TEAR-OFF Mechanically Attached Fully Adhered lnsulation lnsulation Existing roof material removed (reqardless of deck tvpe)lnsulation lnsulation Thermoplastics 1i2023 45 Walk the boards into the adhesive and roll using the 30" wide, 150 pound weighted segmented steel roller to ensure full embedment. Optimal set up time should be approximately 5 to 7 minutes. GAUTION: Walking on the boards immediately after placement in adhesive can cause slippage/movement until the adhesive has started to set up. On roofs with a slope greater lhan 1l2" in 12", begin adhering insulation at the low point and work upward to avoid sliPPage. A person should be designated to walk/roll-in all boards and trim/slit or apply weight as needed to ensure adequate securement. 3. Alternate attachment method, the specifier may select an alternate insulation attachment that incorporates a solid mopping of the insulation with hot asphalt (ASTM D312, Type lll or lV). lf the attachment method is to be covered by the Versico Warranty, Versico must be contacted for specific requirements. Upon review and acceptance by Versico, the maximum warranty coverage available is limited to '15 Year with maximum Peak Gust Wind Speed Coverage of 55 mph, for other warranties contact Versico. a) Extruded or Expanded Polystyrene insulation are not acceptable when this alternate attachment method is specified. b) The existing gravel surfaced built-up roof must be scraped to remove all loose gravel. Large blisters that may prevent continuous embedment of insulation must be repaired. The surface of the substrate must also be dry and clear of foreign material. c) On coal tar pitch, when deemed compatible by the specifier, minimum 1.5" Polyisocyanurate is the required membrane underlayment when using darker heat weldable membranes (tan or gray). lf VersiWeld / VersiFlex white membrane is used, minimum 1" thick Polyisocyanurate is required. d) For successful attachment, proper asphalt temperatures must be maintained and the specifier's requirements concerning the installation of a base sheet (where required) and quantity of hot asphalt must be followed. The maximum insulation board size shall notexceed 4'X4', Trim insulation boards around crickets and saddles to ensure continuous embedment. f) Caremustbeexercisedtopreventcontaminationofthetopsurfaceoftheinsulation. Asphaltoozingthro-ugh insulation joints must be wiped from the surface. Contact with fresh asphalt can result in discoloration of the VersiWeld / VersiFlex membrane. S) A grid shall be installed subdividing the roof in individual sections of 24OA square feet. Required for warranties up to 10 years with wind speed coverage up to 55mph. h) The wood nailers are installed relatively flush with the insulation surface and the membrane is to be fastened with seam fastening plates and Versico HPV or HPVX Fasteners on 12" o.c. For wood nailer installation, refer to Design Reference DR-08-11 "Wood Nailers and Securement Criteria". Mechanically Attached Roofi ng Systems 1. Versico Fasteners and Fastening Plates are required for insulation securement. Refer to lnsulation Fastening Criteria Table in Paragraph 2.05 for appropriate fastener and deck penetration. The fastener can be used with either 2-318" diameter HPVX/HPV-XL Plates OR 3" diameter lnsulation Fastening plate. 2. Any Versico approved insulation or cover board shall be mechanically attached to the roof deck at lhe miriimum rate of 1 fastener and plate per every 8 square feet (4 fasteners in a 4 x 8 board) for warranties up to 15 year. Projects with 20 yearwarranties require the use of 6 fasteners and plates in a 4'x 8' board ('1 per 5.333 square feet). CAUTION: Versico Polyisocyanurate lnsulation with a thickness less than 1.5" installed over an existing roofing membrane without a tear-off must be mechanically attached to the roof deck with a minimum of 1 fastener and plate for every 4 square feet or less of insulation. 3. Use of DensDeck, DensDeck Prime and DensDeck StormX Prime should be limited to assemblies with slopes greater than 2" per foot to ensure compliance with external fire codes e) e) C. 3.05 Membrane Placement and Securement Thermoplastics 1/2023 48 A. General 1. Ensure that water does not flow beneath any completed sections of the membrane system by completing all flashings, terminations and daily seals by the end of each workday. 2. Sweep all loose debris from the substrate. 3. lf aesthetics are of concern, protection should be specified to avoid discoloration of the white membrane surface resulting from adhesive residue or excess foot traffic. 4. ln addition to the primary membrane securement (Bonding for Fully Adhered and Fastening for Mechanically Attached Assemblies), additional membrane securement is required at the perimeter of each roof level, roof section, curb, skylight, interior wall, penthouse, etc., at any inside angle change where slope or combined slopes exceed 2" in one horizontal foot, and at other penetrations in accordance with the applicable Versico details. Refer to Paragraph F for additional membrane securement. B. Membrane Placement Maximum '12'wide VersiWeld or maximum 10'wide VersiFlex Membrane is fully adhered or mechanically attached to an approved insulation or substrate. 1. position VersiWeld or VersiFlex membrane over the acceptable substrate. For a mechanically attached assembly ensure the proper number of perimeter sheets are positioned along the perimeter of the roof as outlined in Paragraph '1 .05 "Warranty Tables". 2. Position field sheets perpendicular to the steel deck flutes in Mechanically Attached Applications. 3. place adjoining membrane sheets in the same manner, overlapping edges appropriately to provide for the minimum overlap width. lt is recommended all overlaps be shingled to avoid bucking of water. C. Membrane Securement / Bonding - Fully Adhered Roofing System 1. Adhere VersiWeld or VersiFlex membrane to an acceptable substrate with Versico Bonding Adhesive. CAV- GRlp 3V Low-VOC aerosol adhesive may be utilized with VersiWeld TPO membranes. CAV-GRIP PVC aerosol adhesive may be utilized with VersiFlex PVC membranes (cannot be used with any KEE or KEE HP bareback membranes). Comply with Labels, Safety Data Sheet (SDS) and Technical Data Bulletins for installation procedures and use. Adhesive must be applied to both the membrane and the surface to which it is being bonded. 2. On projects at high altitudes (6,000' and above), rapid flash-off (drying) of Bonding Adhesive and Primers will occur due to low atmospheric pressure. 3. Fold membrane sheet back so half the underside is exposed. Sheet fold should be smooth without wrinkles or buckles. 4. Stir Bonding Adhesive thoroughly scraping the sides and the bottom of the can (minimum 5 minutes stirring is recommended). Bonding surfaces must be dry and clean. S. Apply Bonding Adhesive to the exposed underside of the membrane and the corresponding substrate area. Do n6iafpty Bonding Adhesive along the splice edge of the membrane to be heat welded over adjoining sheet. When using VersiWeld Bonding Adhesive or VersiFlex Low-VOG Bonding Adhesive, a coverage rate of approximately '120 square feet per gallon per one surface (membrane or substrate) or approximately 60 square feet per gallon per finished surface (includes coverage on both membrane and substrate) shall be achieved. eppiy aOnesive evenly, without globs or puddles with a plastic core, medium nap paint roller to achieve continuous coating of both surfaces. A 9-inch roller will easily fit into the S-gallon containers. A mechanical roller dispenser can be used to apply Bonding Adhesive when the continuous coating and coverage rate noted above are maintained. CAUTION: Due to solvent flash-off, condensation may form on freshly applied Bonding Adhesive when the ambient temperature is near the dew point. lf condensation develops, possible surface contamination may occur and the application of Bonding Adhesive must be discontinued. Allow the surface to dry ind apply a thin freshener coat at the coverage rate which is approximately half the coverage rate stated above to the previously coated surface when conditions allow for continuing. Thermoplastics 1/2023 49 NOTE: When Aqua Base 120 is specified refer to Spec Supplement G-09-'18 "Aqua Base 120 Bonding Adhesive" for application methods and warranty requirements. 6. Allow adhesive to flash-off until it does not string but remains tacky to a dry finger touch. CAUTION: Care must be exercised to ensure proper drying. Avoid thin areas of adhesive because over drying can occur and proper adhesion may not be achieved. 7. Roll the coated membrane into the coated substrate while avoiding wrinkles. B. Brush down the bonded section of the membrane sheet immediately after rolling the membrane into the adhesive with a soft bristle push broom to achieve maximum contact. g. HydroBond Adhesive can be applied directly to the substrate using an airless spray machine or a medium nap roller. Do not apply HydroBond to splice areas to be hot-air welded. When applying HydroBond, ensure that the adhesive has not dried before the membrane is laid in place. This is a wet lay-in adhesive; drying occurs rapidly during high temperatures, and care must be taken to ensure the membrane is laid into wet adhesive. To ensure a weilay-;n, adjust the application technique according to weather conditions. Avoid heavy or thin application of adhesive. Rollthe membrane into the wet, adhesive coated substrate while avoiding wrinkles. lmmediately brush down the bonded portion of the membrane with a soft-bristle push broom or a clean, dry roller applicator to achieve maximum contact and to work out any air bubbles. lmmediately after brooming out from the center, roll the membrane in all directions with a minimum 10G-150-lb (4M8 kg) weighted roller to achieve maximum contact. NOTE: When using Hydrobond Adhesive, do not apply when the surface and/or ambient temperatures are below 40 degrees or when the temperature is expected to drop below 32 degrees within 72 hours of application. Hydrobond Adhesive is a wet lay-in, one-sided adhesive with coverage rate is 100-133 square feet per gallon finished surface. 10. Fold back the unbonded half of the sheet and repeat the bonding procedures. Apply Bonding Adhesive to the remaining exposed underside of membrane and adjacent substrate and complete this section as described above. 1 1. lnstall adjoining membrane sheets in the same manner, overlapping edges a minimum of 2 inches to provide for a minimum 1-112inch heat weld. lt is recommended that all splices be shingled to avoid bucking of water. CAUTION: lf aesthetics are of concern, protect completed sections of the roof so Bonding Adhesive will not discolor the membrane surface. Do not place Bonding Adhesive containers or their lids directly on the surface of the VersiWeldA/ersiFlex membrane. D. Membrane Securement / Fastening - Mechanically Attached Roofing Systems 1. Thermoplastic membranes shall be mechanically attached to the structural deck with specified Versico Fasteners and designated Plates, for fastening densities and numbers of perimeter sheets refer to Warranty Tables, ParagraPh 1.05. 2. Membrane Fastening Selection Table. Mem brane Fastener Selection Refer to Warranty Tables in 1.05 for fastening densities number of perimeter sheets. *Determine proper fastener length for deck penetration, refer to Table 2.05B' ""For mechanically attached PVC and KEE HP assemblies, 2-314" x 1-112" oval metal barbed fastening plates can used in conjunction with HPVX fasteners for membrane securement. (Not recommended for insulation Securement) Versico Plate Min. Penetration Versico Fasteners*Deck Type HPVX P|atesHP\D(314" HPV.XL HPV-XL PIateS Steel or Lightweight lnsulating Concrete over Steel** cD-10 HPVX Plates 1" MP 14-10 HPVX P|ates Structural Concrete, rated 3,000 psi or greater HPVX HPVX Plates Min. 1" HPV-XL HPV-XL P|ates Wood Plank, min. 15/32" thick Plvwood or min. 7/16" OSB.* 1-112"Polvmer Gvptec Gvptec Plates - 2" Dia.Cementitious Wood Fiber 1-112"Polvmer Gvptec Gvptec Plates - 2" Dia.Gvpsum Thermoplastics 1/2023 50 3. On steel decks, membrane shall be positioned with seams perpendicular to the steel deck flutes. This allows the external forces on the roof assembly to be distributed between multiple steel deck panels. Refer to Design Reference DR-06-19 "Wthdrawal Resistance Criteria" in the Versico Technical Manual. 4. Perimeter Sheets The number of perimeter sheets and fastener spacing is dependent on the building height, wind zone location and warranty duration as outlined in Warranty Tables in Paragraph 1.05. The roof perimeter is defined as all edges of each roof section (i.e., parapets, building expansion joints at adjoining walls, penthouse walls, etc.). When multi-level roofs meet at a common wall, the adjacent edge of the upper roof is treated as a roof perimeter if the difference in height is greater than '10'. Perimeter sheets are not required at the base of the wall at the lower level. NOTEI Expansion joints, control joints and fire walls in the field of the roof or roof ridges with slopes less than 3" to the horizontal foot are not considered as part of the roof perimeter. For VersiWeld membranes, perimeter sheets can be formed by using individual 4' to 6' wide sheets or by sub-dividing 8'or 10'wide field sheet using 10" wide Pressure-Sensitive RUSS strip or row of seam fastening piates as described below. For VersiFlex membranes, perimeter sheets can be formed by using individual 40.5" or 5'-0" wide sheets. a) lndividual perimeter sheets (TPO - 4', 5' or 6' wide)(PVC - 40.5" or 5' wide)(KEE HP PVC - 5' wide) Position membrane along the perimeter of the roof over the acceptable insulation/underlayment. The perimeter membrane width from line of securement to line of securement should be approximately 3'-6" to 4'-0" wide. b) RUSS - Reinforced universal securement strip (versiweld Membrane only) 1) When field sheets are positioned parallel to a roof perimeter, 10" wide VersiWeld Pressure- Sensitive RUSS (with 3" wide tape each side) shall be placed approximately down the center of the 8'- 0', 10'-0" or 12'-0" wide VersiWeld TPO field membrane sheets. When a RUSS divides a field sheet in half, two perimeter sheets are created. 2) When field membrane sheets extend perpendicular to the edge of the roof, position the 10" wide VersiWeld Pressure-Sensitive RUSS beneath the membrane along the center of each field sheet extending a distance equal to 0.4 times the building height to create perimeter sheets. GAUTION: 6" wide VersiWeld Pressure-sensitive RUSS is only available with 3" wide QA Seam Tape on one side and therefore cannot be used to form perimeter sheets. c) Fastening Plates Method ln lieu of the RUSS securement method, position a row of seam fastening plates in the locations identified in Paragraph 4.b.1 and 4.b.2, secure plates with appropriate fastener and overlay plates either 6" wide Pressure-Sensitive TPO Cover Strip (TPO Only) overlay the plates as follows: 1) VersiWeld lnstallation - Warranties Up to 20 Years - 6" wide Pressure-Sensitive TPO Cover Strip or 6" wide VersiWeld membrane centered over the plates and heat welded to the field membrane. Seal cut edges of TPO overlay with TPO Cut-Edge Sealant to seal any exposed scrim, cut edge sealant is not required for PVC or KEE HP. 2) projects with Warranties greater than 20 Years OR VersiFlex projects regardless of warranty duration' center 6" wide section of TPO/PVC/KEE HP PVC membrane (equal thickness to the deck membrane) over the plates and heat weld the field sheets. All cut edges of TPO overlay must be sealed with TPO Cut-Edge Sealant to seal any exposed scrim, cut edge sealant is not required for PVC or KEE HP. NOTE: Perimeter sheets can also be formed by positioning RhinoBond plates placed along the center of a field membrane (if heat induction welder is available on job-site). Refer to "Attachment l" for additional information. d) Building with Special Gonditions: Air pressurized buildings, canopies and buildings with large openings where the total wall openings exceed 10% of the total wall area on which the openings are located (such as airport hangars, warehouses and large maintenance facilities) will typically require additional perimeter membrane securement, an increased Thermoplastics 1/2023 51 fastening densi$ or other enhancement. e) Buildings with large openings When any wall contains major openings with a combined area which exceeds 10% of the total wall area on which the openings are located, four (4) perimeter sheets (centered over the opening) must be specified as shown. As an option to the above perimeter securement, a fully adhered membrane section may be used in lieu of the mechanically attached membrane at large openings in accordance with the Versico Specification for the VersiWeldA/ersiFlex Fully Adhered Roofing System. NOTE: Depth of perimeter area, noted above, shall not be less lhan 2.5 times the width of the opening. f) Buildings with overhangs The membrane must be specified with perimeter sheets installed over the entire overhang area extending onto the main roof deck when at the same level. As an option, a fully adhered membrane section may be used in lieu of the mechanically attached membrane at building overhangs in accordance with the Versico Specification for the VersiWeldA/ersiFlex Fully Adhered Roofing System. II.IgTALL PERIMETER 5HEETs OVER THE ENTIRE OVERHANg AREA EXTENPINE ON?O I{E llArN ROoF DEOR f,ttrEN Ar rHE 9AMELEVEL A9 9HOL{N. FOI'R PERIMETER 9}IEET9 AENTERED OVER oPENlNg A9 PERIMETER 5}IEET gEE I,IOTE 5. Field Membrane a) Position adjoining field membrane sheets to allow an approximate overlap of 5-112" al those locations where Fastening Plates are located (along the length of the membrane); at the same time overlap end roll sections (the width of the membrane) a minimum of 2". b) Secure the membrane at the approved fastening density with the required Versico Fastener and Fastening Plates. c) For installation of membrane with fullness, tighten the sheet between fasteners as follows: '1) Unroll sheets and Position. 2) Place a fastener and plate in one end of the sheet on the appropriate fastener mark. Go to the opposite end of the sheet, pull it tight and place a fastener and plate at the appropriate mark. Place the remaining fasteners into the sheet. 3) Proceed to weld the sheet in place and continue across the roof. 6. Prevention of membrane distortion during windy conditions: a) Unroll sheet approximately 5' and position edge of membrane with overlap line on adjacent sheet. b) lnstall fasteners along the 5' exposed edge. c) While the 5' of expgsed membrane is being fastened, begin welding the overlapped edge using the Automatic Heat Welder. Thermoplastics 1/2023 52 d) As sheet is being welded and fastened concurrently, unroll membrane. Unroll only enough membrane to stay a few feet ahead of welding and fastening process. This reduces amount of unsecured membrane to be distorted by wind. e) Continue this process for each adjoining sheet. VersiWeld QA (Quick-Applied TPO) - Quick-Applied Roofing System (membrane bonding) 10' wide VersiWeld QA TPO is fully adhered to an approved insulation or substrate with Factory Applied Quick- Applied Adhesive. 1. Position VersiWeld QA TPO membrane over the acceptable substrate. 2. Fold membrane sheet back so half the underside is exposed. 3. Remove the release liner on one half of the sheet starting from the split in the liner at the middle of the sheet. The liner should be removed at an angle to reduce risk of splitting or tearing. 4. Roll the membrane onto the substrate while avoiding wrinkles. To achieve the best adhesion, the membrane should be rolled onto the substrate at an angle with 30" wide 150 lb weighted segmented roller. \Men applying the VersiWeld QA TPO membrane it is recommended to maintain a large curve on the leading edge of the membrane. This will help eliminate creases and bubbles that cannot be removed after the sheet is in place. 5. Fold back the remaining half of the sheet and repeat the above process. Additional Membrane Securement 1. Securement must be provided at the perimeter of each roof level, roof section, expansion joint, curb, skylight, interior wall, penthouse, etc., at any inside angle change where slope exceeds 2 inches to one horizontal foot, and at all penetrations as identified on the Versico details. 2. Securement may be achieved as follows; On Mechanically Attached Roofing Systems, Versico's HP\D( Fastening Plates are used to secure the membrane with the appropriate Versico Fastener at the base of walls and penetrations and flashed as shown on the applicable Versico detail (excluding OSB, cementitious wood fiber and gypsum decks where the required Versico Fastener is installed with the associated 2" diameter plate). On Fully Adhered Roofing Systems, Versico standard 2" diameter Seam Fastening Plates may be used in lieu of HPVX Plates. Securement of the membrane shall be a maximum of 12 inches on center. Starting 6 inches minimum to 9 inches maximum from the inside or outside corner. c) On Mechanically Attached assemblies, additional membrane securement is required around pipes and sealant pockets as shown on the applicable detail. The plates must be positioned a maximum of 12" away from the penetration, spaced a maximum of 12" on center and flashed in accordance with the applicable Versico Detail" d) After securing the membrane, flash in accordance with the appropriate detail 3.06 Heat Welding Procedures A General 1. APEEL Protective Film should be removed from within areas that are to be heat-welded together. ln areas that do not require heat welding, the APEEL Protective Film can be left in place for up to 90 days. 2. Heat weld the VersiWeld or VersiFlex membrane sheets using the Automatic Heat Welder or Hot Air Hand Welder and silicone roller. 3. When roof slope exceeds 5" per horizontal foot, use of the Automatic Heat Welding Machine may become more difficult; use of the Handheld Hot Air Welder is recommended. 4. Gheck the surfaces of the membrane to be heat welded to ensure they are properly prepared. The surfaces to be heat welded must be clean. Membrane overlaps that become contaminated with field dirt must be cleaned with Weathered or PVG and KEE HP Membrane Cleaner (Weathered Membrane Cleaner E F a) b) Thermoplastics 1/2023 53 should not be used to clean VersiFlex PVC). Weathered or PVC and KEE HP Membrane Cleaner should be wiped dry with a clean Splice Wipe prior to welding. No residual dirt or contaminants should be evident. B. Automatic and/or Handheld Heat Welder Equipment Refer to Spec Supplement T-01-18 "Heat Welding Equipment" for:a) Temperature Settingsb) Equipment Set-upc) Additional lnformation C. Membrane Welding Prepare the Automatic Heat Welder and allow it to warm for approximately 5 to 10 minutes to reach operating temperature. 2. Position the Automatic Heat Welder properly prior to seaming with the guide handle pointing in the same direction the machine will move along the seam. 3. Lift the overlapping membrane sheet and insert the blower nozzle of the Automatic Heat Welder between the overlap. Machine will begin moving along the seam immediately. 4. Weight plates provided on Automatic Welders must be utilized. 5. Proceed along the seam ensuring that the small guide wheel in front of the machine aligns with the edge of the top membrane sheet. Guide the machine from the front only. CAUTION: Ensure the power cord has plenty of slack to prevent dragging the machine off course (which could result from a tightly stretched cord). 6. At all splice intersections, roll the seam with a silicone roller to ensure a continuous heat welded seam (the membrane should be creased into any membrane step-off with the edge of the silicone roller). A false weld may result due to surface irregularities created by multiple thicknesses of VersiWeldA/ersiFlex membrane sheets. When using 60-mil or 80-mil VersiWeld or 80-mil VersiFlex Membrane, a TPO/PVC "T" Joint Cover must be applied over all "T" joint splice intersections. 7. To remove the Automatic Heat Welder from the finished splice, disengage and pull the nozzle from the seam area, the machine will stop automatically. 8. Mark the end of the heat welded seam with a water-soluble marker for easy identification. A Handheld Welder will be necessary to complete the weld in the area between where the Automatic Heat Welder is stopped and restarted. 9. Perform a test weld, at least, at the start of work each morning and afternoon. Test welds should be made if any changes in substrate or weather conditions occur. 10. All membranes, at end laps, a minimum 6" wide, reinforced coverstrip must be used in conjunction with applicable primer. D. Preventing Membrane Creeping During Welding I 1 The operator of automatic welding equipment must apply foot pressure to the membrane, keeping the membrane tight under the welder. Refer to Spec Supplement T-01-18 "Heat Welding Equipment" for additional information. E. Test Cuts Perform a test weld at least at the start of work each morning and afternoon. Refer to Spec Supplement T-01- 18 "Heat Welding Equipmenf' for additional information. F Seam Probing 1. A cotter pin puller (blunt or dull for PVC or KEE HP Membranes) or Versico TPO Seam Probe is recommended to probe all heat-welded seams. Probing seams must be done once heat welds have thoroughly cooled. Refer to Spec Supplement T-01-18 "Heat Welding Equipment" for additional information. Thermoplastics 1/2023 54 G. Gut-Edge Sealant 1. Apply Cut-Edge Sealant on all cut edges of the VersiWeld reinforced membrane (where the scrim reinforcement is exposed) afterseam probing is completed. When a 1/8" diameter bead of TPO Cut-Edge Sealant is applied, approximately 225 - 275linear feet of coverage per squeeze bottle can be achieved. a) Cut-Edge Sealant is not required on cut edges of VersiFlex membrane (Horizontal or Vertical). b) Cut-Edge Sealant is not required on vertical VersiWeld splices. 3.07 Welding Problems I Repairs A Handheld Hot Air Welder and a 2" wide silicone roller must be used when repairing the VersiWeldA/ersiFlex membrane. When the entire heat welded seam is to be overlaid, an Automatic Heat Welder may be used. B. Prior to proceeding with any repair procedure, the area to be repaired must be cleaned with Weathered or PVC and KEE HP Membrane Cleaner fl//eathered Membrane Cleaner should not be used to clean VersiFlex PVC or KEE HP Membrane). The membrane can typically be repaired with standard cleaning methods. ln cases where the standard cleaning method is not sufficient, the following procedures must be used. 1. Scrub the area to be welded with a "Scotch Brite" Pad and Weathered or PVC and KEE HP Membrane Cleaner. 2. Clean all residue from the area to be welded with a Splice Wpe or a clean natural fiber (cotton) rag. 3. Weld the new membrane to the cleaned area using standard welding procedures. Voids in welded seams can be repaired using a Handheld Hot Air Welder and a silicone roller. Depending on conditions, a splice overlay may be required. Position the handheld welder facing into void so hot air is forced between overlapping membranes. Roll the top membrane surface using positive pressure toward the outer edge until the heated membrane surfaces are fused. Exposed scrim-reinforcement (resulting from scorching surface of membrane) and test weld areas must be repaired by overlaying the damaged area with a separate piece of VersiWeldA/ersiFlex reinforced membrane with rounded corners. The overlay must extend a minimum of 2 inches past the area to be repaired. Probe all edges of the overlay once cooled to ensure a proper weld has been achieved. Seal all cut edges of VersiWeld reinforced membrane with TPO Cut-Edge Sealant. Cut-Edge Sealant is not required on cut edges of VersiFlex Membranes. The same overlay repair procedures may be used for puncture in the VersiWeldA/ersiFlex membrane. 3.08 Flashings A. GeneralGonsiderations 1. The height of new wall flashing must extend above the anticipated water level or slush line. 2. On 15- or 2O-year warranty projects, Versico's Termination Bar, in conjunction with Water Cut-Off Mastic, must be specified under all metal counterflashings and surface mounted reglets. 3. To comply with various warranty options, flashing material must equal the required minimum membrane thickness but shall not be less than 60 mils thick. For projects with 25 year or greater warranties Versico Pre- Fabricated accessories must be used when feasible. 4. All Projects, regardless of Warranty Duration, shall incorporate Versico supplied pre-fabricated accessories to seal pipes, corners, sealant pockets, etc., when feasible. When field fabrication is required, the flashing material shall not be less than 60-mils thick. 5. For wall and curb flashing, the required thickness shall equal the deck membrane thickness. On Retrofit Projects Bitumen-based roof cement and asphaltic-based flashing material, if allowed to remain in contact with the membrane, will cause severe membrane discoloration and for PVC and KEE HP membranes, promote premature plasticizer migration. Existing wall and curb flashing must be removed or concealed with a new A c. D. E. F G Note: 6 Thermoplastics 1/2023 55 7 acceptable substrate. a) The specifier must examine structural supports for rooftop equipment to determine if reasonable access to the membrane beneath the equipment is provided. Versico should be consulted for clarification when access to the membrane system will be restricted. b) When hot pipes or other similar penetrations exceed 140"F (60"C) (PVC/KEE HP) or 160"F (71"C) (TPO), they must be designed to incorporate an insulated metal collar and rain hood designed to maintain a surface temperature less than 140'F (60'C) (PVC/KEE HP) or 160"F (71"C) (TPO). When possible, all reinforced membrane splices are heat welded with the Automatic Heat Welder. The Hand Held Hot Air Welder should be utilized in hard to reach areas, smaller curbs, vertical splices and when using non-reinforced mem brane. a) The new VersiWeldA/ersiFlex membrane flashing must not conceal weep holes or cover existing throughwall flashing. b) lnstall surface mounted reglets and compression bar terminations directly to the wall surface. ln areas where metal counterflashing or surface mounted reglets are used as vertical terminations, the counterflashing must be sealed with a rubber grade caulking to prevent moisture migration behind the new wall flashing. 8. B.Application of Bonding Adhesive 1. Membrane shall be fully adhered to vertical surfaces with VersiWeldA/ersiFlex Bonding Adhesive. CAV-GRIP 3V low-VOC aerosol adhesive may be utilized with VersiWeld TPO membranes. CAV-GRIP PVC aerosol adhesive may be utilized with VersiFlex PVC membranes (cannot be used with any KEE or KEE HP bareback membranes). The Bonding Adhesive shall be applied continuously, without globs or puddles. 2. Allow adhesive to flash-off until it is tacky but will not string or transfer to a dry finger touch. 3. Roll the membrane into the adhesive. 4. Care must be taken when setting the flashing to avoid bridging greater than 3/4 inch at angle changes (i.e., where a parapet or roof penetration meets the roof deck). This can be accomplished by creasing the membrane into the angle change. 5. Terminate the edges of the installed membrane in accordance with Versico's applicable details. 6. When using TPO membrane flashing only, bonding adhesive is not required when the flashing height is 12" or less. When Versico termination bar is used beneath the counter-flashing, bonding adhesive can be eliminated when the flashing height is 18" or less. C. Walls, Parapets, Gurbs, Skylights, etc. The flashing height must be calculated so that the VersiFlex membrane flashing includes a minimum 1-1i2 inch heat weld beyond the Fastening Plates. 1. Fasten at angle change as identified in Paragraph 3.05 F, Additional Membrane Securement, with the required Versico Fastener and Plate. 2. Flash the fasteners/plates with a separate piece of VersiWeldA/ersiFlex reinforced membrane; apply heat and crease the flashing into the angle change before attaching it to the vertical surface. D. Metal Edge Terminations Factory-fabricated metal edge systems must be secured to the wood nailer as specified by the manufacturer. Shop- fabricaied edging must be installed in compliance with appropriate Versico Detail using Versico TPO/PVC Coated Metal in orderto achieve ES-1 Compliance. Refer to the appropriate Universal Details for other flashing options and requirements. E Roof Drains 1. VersiWeldA/ersiFlex membrane may extend into the drain sump when the slope of the sump is less than 3" to one horizontal foot. Thermoplastics 112023 56 When the drain sump is greater than 3" to one horizontal foot, additional membrane securement must be installed. 2. Only drain strainers that have been approved by the specifier in accordance with applicable codes may be used. F. VersiWeld/VersiFlex Rib Profiles VersiWeldA,/ersiFlex Rib Profiles are recommended for use with VersiFleece TPO and PVC adhered roofing systems. 2. The VersiWeldA/ersiFlex Rib Profiles should be positioned parallel to the laps of the installed TPO/PVC roofing system and parallel with the roof slope where possible. 3. Ensure that all welding surfaces are clean and dry. lnspect all seam areas for proper weld prior to installing VersiWeldA/ersiFlex Rib Profi le. 4. Rib Profile spacing can be individually determined to achieve the desired appearance. 5. Connecting multiple ribs is achieved by using fiberglass pins. lnsert a pin half-way into the end of one profile. Connect the adjoining rib by inserting the exposed end of the pin into the alignment hole. Repeat previous steps for additional TPO/PVC Rib profiles. 6. Consult the VersiWeld or VersiFlex Rib Profile installation guides for instructions on proper installation techniques. G. Other Penetrations On Mechanically Attached assemblies, additional membrane securement is required around pipes and sealant pockets as shown on the applicable detail. The plates must be positioned a maximum of 12" away from the penetration, spaced a maximum of 12" on center and flashed in accordance with the applicable Versico Detail. 1. Pipes, Round Supports, etc. a) Flash pipes with Molded Pipe Flashings or Split Pipe Seals where their installation is possible. Molded pipe flashings cannot be cut and patched; deck flanges cannot be overlapped or installed over angle changes. b) Where Molded Pipe Flashings or Split Pipe Seals cannot be installed, APPLY FIELD FABRICATED PIPE FLASHING using VersiWeldA/ersiFlex non-reinforced membrane. 2. Flexibte Penetrations (braided cables, conduits, wires, etc.) must be enclosed in a stable "goose neck." Apply a Split Pipe Seal or field fabricated pipe flashing to flash the goose neck. 3. Hot pipes that exceed 140'F (60'C) (PVC/KEE HP) and 160'F (7'1'C) (TPO), must utilize an insulated metal collar and rain hood, flashed with a field fabricated pipe flashing. 4. For pipe clusters or unusually shaped penetrations, a Molded Sealant Pocket and White One-Part Sealant must be utilized. 5. Existing Roof Tielns for PVC or KEE HP PVC membranes require total isolation between the two roofing systems. For TPO membranes refer to applicable Versico details for tie-ins. 6. Flashing of Difficult Penetrations, referto Spec Supplement G-'11-20 for "LIQUISEAL Liquid Flashing" for additional information and specific requirements. H. APEEL Protective Film (Optional) When the optional APEEL Protective Film is utilized on TPO or PVC/KEE HP, remove and discard the APEEL Protective Film after the installation of the entire TPO or PVC/KEE HP Roofing System is complete. 3.09 Roof Walkways Walkways are to be specified at all traffic concentration points (i.e., roof hatches, access doors, rooftop ladders, etc.), and if regular maintenance (once a month or more) is necessary to service rooftop equipment. Refer to Spec Supplement G-05-l8 "Roof Walkway Installation". Thermoplastics 1/2023 57 3.10 Daily Seal On phased roofing, when the completion of flashings and terminations is not possible by the end of each workday, provisions must be taken to temporarily close the membrane to prevent water infiltration. Refer to Spec Supplement G- 06-20 "Daily Seal & Glean Up". Copyright 2023 Versico Roofing Systems Versico, VersiWeld, VersiFlex, VersiCore, VersiTrim, DuraFaceR, LIQUISEAL and Flexible DASH are Trademarks of Versico lnsulfoam, lnsulLam and R-Tech are Trademarks of lnsulfoam Thermapink, Foamular and Durapink are Trademarks of Owens Corning DensDeck, DensDeck Prime and DensDeck StormX Prime are Trademarks of Georgia-Pacific Corporation Securock is a Trademark of USG Styrofoam is Trademark of the DOW Chemical Company Olybond is a Trademark of OMG, lnc. This specification represents the applicable information available at the time of its publication. Owners, specifiers and Versico Authorized Roofing Contractors should consult Versico or their Versico lndependent Sales Representative for any information, which has subsequently been made available. Review the appropriate Versico warranty for specific wananty coverage, terms, conditions and limitations. Thermoplastics 1/2023 58 r THERMOPLASTIC MEMBRANE TD^ /D\/r. i- 3/4" (2cm) ro 8" (2ocm) STAINLESS STEEL CLAMPING RING INCLUDED WATER CUT_OFF MASTIC THERMOPLASTIC PRE_MOLDED PIPE FLASHING HOT A|R-WELD, 1-1/2" (+cm) MrN. BEYoND FASTENING PLATES NOTES: REMOVE ALL EXISTING LEAD AND FLASHING MATERIAL BEFORE INSTALLING PRE_MOLDED PIPE FLASHING. 2. TEMPERATURE OF THE ptpE PENETRATTON MUST NOT EXCEED 140'F (60'C) WHEN USING PVC AND 160'F (71'C) WHEN USING TPO FLASHING. 3. PIPE SEAL MUST HAVE INTACT RIB AT TOP EDGE, REGARDLESS OF PIPE DIAMETER. 4. INSTALL A MINIMUM OF 4 FASTENERS AND PLATES AROUND THE PIPE, EQUALLY SPACED. IF FASTENERS AND PLATES CANNOT BE INSTALLED AS SHOWN, THEY MAY ALSO BE POSITIONED ouTStDE THE ptpE MAXTMUM 12" (30cm) O.C.AND FLASHED WITH THERMOPLASTIC REINFORCED MEMBRANE/CUT-EDGE SEALANT. REFER TO DETAIL TPC-8.2. 5. FASTENERS AND PLATES ARE NOT REQUIRED ON ADHERED SYSTEMS UNLESS PIPE DIAMETER EXCEEDS 18" (46cm). 6. ON MECHANICALLY ATTACHED SYSTEMS, HPVX FASTENERS AND PLATES OR HPV_XL FASTENERS AND PLATES ARE REQUIRED OVER STEEL AND WOOD DECKS. ON CONCRETE DECKS, CD_10 OR MP 14-10 FASTENERS ARE USED WTH HPVX PLATES. 1 3 & SEAM FASTENING PLATE, MAX. 12'' (socm) o.c. 4 5 6 O f.r L-o(o trl o_ o- oJoO THERMOPLASTIC ROOFING SYSTEM TPC_8.1 THERMOPLASNC REINFORCED MEMBRANE o * APPROVED SUBSTRATE - sEE NolE(s) vVERSICO ROOFING SYSTEMS @ 202J VERSTCO PRE_MOLDED FLASHING -THERMOPLASTIC MEMBRANE WATER CUT_OFF MASTIC STAINLESS STEEL CLAMPING RING BY OTHERS TPO ROOF REINFORCED TPO TPO/PVC r PVCIKEE HP ROOF PRE-CUT REINFORCED PVC OR KEE HP HOT AIR-WELD, THERMOPLASTIC NON-REINFORCED FLASHING CUT-EDGE T FOR HOT AIR WELD TPO ONLY NOTES: 1. REMOVE ALL EXISTING LEAD AND FLASHING MATERIAL BEFORE INSTALLING FIELD FABRICATED PIPE FLASHING. 2. TEMPERATURE OF THE PIPE PENETRATION MUST NOT EXCEED 140'F (60'c) WHEN US|NG PVC AND 160'F (71'C) WHEN USING TPO FLASHING. 3. THERMOPLASTIC NON-REINFORCED FLASHING WRAPPED AROUND P|PE SHALL HAVE MTNTMUM 1-1/2" (acm) VERTICAL HOT AIR WELD. 1-1/2" (m) t'lttrl. a. DIMENSIONS cm @ 1-1 /2"4 TO 2"5 @ 1"2.5 MIN. 1 /2"1.5 MIN @ 12"30 APPROX 4. TNSTALL A M|N|MUM OF 4 SEAM FASTENING PLATES FOR PIPES WTH A DIAMETER UP TO 6" (15cm). ADDITTONAL SEAM FASTENING PLATES WLL BE REQUIRED FOR PIPES GREATER THAN 6" (tScm) lN DIAMETER AND SHALL BE SPACED tZ" (30cm) ON CENTER MAXIMUM. 5. FASTENERS/PLATES ARE NOT REQUIRED ON ADHERED SYSTEMS UNLESS PIPE DIAMETER EXCEEDS 18'' (socm). 6. ON MECHANICALLY ATTACHED SYSTEMS, HPVX FASTENERS AND PLATES OR HPV-XL FASTENERS AND PLATES ARE REQUIRED OVER STEEL AND WOOD DECKS. ON CONCRETE DECKS, CD_10 OR MP 14-10 FASTENERS ARE USED WTH HPVX PLATES. 7. APPROXIMATELY 1/A" (O.Scm) DIAMETER BEAD OF CUT-EDGE SEALANT lS REQUIRED ON CUT EDGES OF REINFORCED TPO MEMBRANE. z.oF C) DETAIL NOT FOR USE ON 25 OR 3O_YEAR WARRANTY PROJECTS, PRE_FABRICATED ACCESSORIES MUST BE UTILIZED. ACCEPTABLE PIPE FLASHINGS SHALL CONFORM W THERMOPLASTIC COMMON DETAILS TPC_8.1. TPC-8.3 OR TPC_8.4. /PRE-MOLDED TH o N LJ-o @ LrJL o- oJoO VERSICO FASTENER & SEAM FASTENING PLATE, MAX. 12'' (3ocm) o.C. 4 5 6 THERMOPLASTIC ROOFING SYSTEM THERMOPLASTIC REINFORCED MEMERANE o - APPROVED SUBSTRATE - sEE NoTE(S)TP C _ 8,2 vVERSICO ROOFIN G SYSTEM S @ 2023 VERSTCO FIELD FABRICATED PIPE FLASHING I THERMOPLASTIC MEMBRANE 9.1 MECHANICAL TERMINATION IVITH COUNTER FLASHING IERSICO UNIVERSAL SINGLE-PLY SEALANT OR SEALANT (BY OTHERS) METAL COUNIER-FLASH|NG (BY oTHERS). VERSICO ZINC NAIL-IN ANCHOR VERSICO TERMINATION BAR MlN. 1/4" (1cm) -lL-yax.1/2" (t.scm) rPo/Pvc -NOTES:1. APPLY ON HARD SMOOTH SURFACE ONLY; NOT FOR USE ON EXPOSED WOOD. 2. DO NOT WRAP TERMINATION BAR AROUND CORNERS. 3. DETAIL REQUIRED FOR USE ON WARRANTY PROJECTS EXCEEDING 20_YEARS. 4. DETAIL 9.5 MUST BE USED AT VERTICAL JOINTS IN PANEL WALLS.@ @ 9.2 sHEEr MErAL COPTNG (BY OTHERS) METAL CAP (BY OIHERS), SL0PE DOW\WARD TOWARDS ROOF EXTEND MEMBRANE BELOW JOINT NOTES:1. FOR VERSICO VERSITRIM COPING, REFER TO INSTALLATION INSTRUCTIONS PUBLISHED SEPARATELY. 2. MEMBRANE MUST BE EXTENDED TO CORNERS TO PROVIDE COMPLETE COVERAGE OF THE TOP WALL SURFACE. 9.3 COUNTER FLASHINC IERMINATION IERSICO UNIVERSAL SINGLE-PLY SEALANT OR SEALANT (BY OTHERS) METAL C0UNTER-FLASHING (BY oTHERS). FASTEN MEMBRANE @ 12" (Jocm) 0.C. MAX. NOTES:1. WHEN MECHANICAL FASTENERS ARE USED TO PENETRATE THE METAL COUNTER_FLASHING, USE EPDM WASHERS, APPLY WATER CUT_OFT MASTIC UNDER THE COUNTER-FLASHING OR CAULK THE FASTENER HEADS. 2. DETAIL NOT FOR USE ON WARRANTY PROJECTS EXCEEDING 1O_YEARS. 9.4 MECHANICAL TERMINATION \ERSICO UNIVERSAL SINGLE-PLY SEALANT OR SEALANT (BY OTHERS) VERSICO ZINC NAIL_IN ANCHOR RECoMMENDED @ 6" (15cm) 0.C. IERSICO TERMINATION BAR MlN. 1/a" (1cm) ,IL-llnx.i/2" (t.5cm) NOTES:I. APPLY ON HARD SMOOTH SURFACE ONLY; NOT FOR USE ON EXPOSED WOOD. 2. DO NOT WRAP COMPRESSION TERMINATION BAR AROUND CORNERS. DETAIL NOT FOR USE ON WARRANTY PROJECTS EXCEEDING 20_YEARS. 4. DETAIL 9.5 MUST BE USED AT VERTICAL JOINTS IN PANEL WALLS 3. @ @ APPLICABLE BONDING ADHESIVE.XXXXXXXX WATER CUT-OFF MASTIC _ MUST BE HELD UNDER CONSTANT COMPRESSION. THERMOPLASTIC ROOFING SYSTEM TI.IERMOPLASTIC REINFORCED MEMBRANE 0 - APPROVED SUBSIRATE - sEE NoTE(S)TPC_9.0A v R OOFIN G SY @ 202J VERSTCO MEMBRANE TERMINATIONS, PAGE 1 OF 2 I THERMOPLASTIC MEMBRANE 9.5 MECHANICAL TERMINATION AT VERTICAL JOINT IERSICO UNIVERSAL SINGLE-PLY SEALANT OR SEALANT (BY OTHERS) VERSICO TERMINATION BAR METAL COUNIER FLASHING (BY 0THERS). 5. THIS DETAIL MUST BE USED FOR ANY PROJECT REGARDLESS OF WARRANTY. rPolPVC -NOTES:I. APPLY ON HARD SMOOTH SURFACE ONLY. 2. DO NOT IARAP COMPRESSION TERMINA]ION BAR AROUND CORNERS. 3. VERTICAL JOINTS IN THE PRE-CAST PANEL AS WELL AS ALL GAPS AT THE JUNCTION OF IHE TILT_UP PANEL AND ROOF DECK MUST BE FULLY SEALED TO PREVENT AIR INflLTRATION. +, CONTINUOUS COUNTER FLASHING REQUIRED FOR WARRANTY PROJECTS EXCEEDING 20_YEARS. SEALANT (BY 0THERS) pr 9.6 \ERSITRIM 2OO & 3OO COPING NOTE:1. MEMBRANE SHOULD BE EXTENDED AT CORNERS TO PROVIDE COMPLETE COVERAGE OF THE TOP WALL SURFACE. REFER TO DETAIL TPE 9.0. 2. REFER TO VERSITRIM COPING INSTALLATION INSTRUCTION MANUAL FOR STEP_BY-STEP INSTRUCTION PROCEDURES. 9.7 COPING STONE TERMINA1ION COPING STONE & ANCHORS (BY OTHERS) ttATER CUT-OFF MASIC AROUND DOWEL OR ANCHORS WATER CUT_OFF MASTIC SEALANT (BY OTHERS). UNDER THE MEMBRANE LIP. COPING 20 GA. GALVANIZED ANCHOR CLIPS @ 6 FEET (ta3cm) 0.C. CONCEALED SPLICE PLATE AT EACH JOINT OF COPING HEX_HEAD FASTENERS APPLICABLE BONDING ADHESIVE.XXXXXXXX WATER CUT_OFF MASTIC _ MUST BE HELD UNDER CONSTANT COMPRESSION THERMOPLASTIC ROOFING SYSTEM TP C - 9.0 B MEMBRANE TERMINATIONS, PAGE 2 OF 2 TTIERMOPLASNC REINFORCED MEMBRANE 0 _ APPROVED SUBS1RATE - sEE NorE(s) vVERSICO ROOFING SYSTEMS o 2023 VERSTCO I THERMOPLASTIC MEMBRANE NOTES: 2. APPROXIMATELY BEAD OF CUT_E 1/8" (0.5cm) DGE SEALANT rPolPVC - DIAMETER IS REQUIRED FASTEN COATED METAL FLASHING TO WOOD NATLERS USING 1-1/2" (acm) MlN. RING SHANK NAILS SPACED 6" (15cm) ON CENTER AND STAGGERED APPROX. 1/2" (t.Scm). ON CUT EDGES OF REINFORCED TPO MEMBRANE. 1 CREASE COATED METAL FLASHING ALONG DASHED LINES AFTER CUTTING AND REMOVING SHADED TRIANGLE. CREASE LINE (7.scm) FLANGE r 3"APPROX. VERTICAL LINE OF CORNER COATED METAL WDE DECK CUT ALONG LINES 2 OVERLAP FLANGE AT CORNER AND NAILERS USING 1-tl2" (acm) RlNc SHANK NAILS SPACED 6" (15cm) O.c., STAGGERED 1/2" (t.Scm). IN TO WOOD COATED MET OVER LAP FLANGE OF COATED METAL l/+" (lcm) Glle THERMOPLASTIC 3 HEAT WELD 3" (7.5cm) WDE SECION OF NON-REINFORCED MEMBRANE OVER VERTICAL JOINT IN COATED METAL AND OVER CUT EDGE AT CORNER AS SHOW!. HEAT WELD 3,, NON_REIN (z.scm) wor PIECE OF MEMBRANE OVER JOINT + MEMBRANE OVER 3" (7.5cm) WDE NON-REINFORCED MEMBRANE. HEAT WELD 6" (1 WDE PIECE OF REINFORCED 6" (1scm) WDE NON-REINFORCED MEMBRANE 5 INSTALL FIELD MEMBRANE AND HEAT WELD TO FLANGE OF COATED METAL. ALSO INSTALL INSIDE CORNER FLASHING PER TPC_15,1 OR TPC-.Is.2 DETAILS. INSIDE CORNER FLASHING vVERSICO INSIDE CORNER WITH COATED METAL WALL FLASHINGROOFING SYSTEMS o 2023 VERSTCO THERMOPLASTIC REINFORCED MEMBRANE - APPROVED SUBSIRA'IE 0 - sEE NOTE(S) THERMOPLASTIC ROOFING SYSTEM TPC- 15.3 ITHERMOPLASTIC MEMBRANE rPo/Pvc -z.oF:) O DETATL NOT FOR USE ON 25 OR 3o-YEAR WARRANTY PROJECTS, PRE-FABRICATED/PRE-MOLDED ACCESSORIES MUST BE UTILIZED. ACCEPTABLE FLASHING SHALL CONFORM WTH THERMOPLASTIC COMMON DETAIL TPC-15.4. THERMOPLASTIC NON-REINFORCED. MEMBRANE. PIECE APPLY HEAT TO THERMOPLASTIC NON_REINFORCED MEMBRANE AND FORM BY HAND PRIOR TO HOT AIR WELDING CORNER INTO PLACE POSITION AND HEAT WELD CORNERS IN PLACE AS SHOWN ROUND CORNERS OF NON_REINFORCED MEMBRANE Ml N. r_ ^'fi83*ru"_-_l APPROX. 6" 15cm( C t, 1' . THERMOPLASTIC . .NON_REINFORCED. . MEMBRANE PIECE NON-REINFORCED MEMBRANE I.FIERMOPLASTIC .P[ECE. THERMOPLASTIC ROOFING SYSTEM TPC-15.5 FIELD FABRICATED OUTSIDE CORNER FLASHING THERMOPLASTIC REINFORCED MEMBRANE 0 * APPROVED SUBSTRATE - sEE NOTE(S) vVERSICO ROOFING SYSTEMS @ 202J \GRSTCO ITHERMOPLASTIC MEMBRANE REFER TO APPLTCABLE DETATL(S) IN LATEST EDITION OF SMACNA THERMOPLASTIC COATED SHEET METAL SCUPPER SEALANT (BY OTHERS) NOTES: WOOD NAILERS ARE INSTALLED AT SCUPPERS TO SECURE METAL SLEEVE AND MUST EXTEND PAST THE WIDTH OF METAL SLEEVE FLANGE. 2. METAL SCUPPER BOX MUST HAVE CONTINUOUS FLANGES WITH ROUNDED CORNERS. SOLDER ALL SCUPPER SEAMS WATER_TIGHT. J. WATER CUT_OFF MASTIC UNDER SCUPPER FLANGES MUST BE UNDER CONSTANT COMPRESSION. 4. SCUPPER FLANGES MUST BE TOTALLY COVERED BY NON-REINFORCED FLASHING WITH MINIMUM 2" (5cm) COVERAGE PAST NAIL HEAD. rPo/Pvc - APPLICABLE BONDING ADHESIVE - - - HOT AIR WELD 1-1/2" (+cm) uttrt THERMOPLASTIC NON_REINFORCED FLASHING HOT AIR WELD, 1-1 /2" (acm) MlN.q*ffi A 4 1 (BY oTHERS) WOOD NAI CUT_OFF MASTIC 3 I I J XXX WATER vVERSICO ROOFING SYSTEMS @ 2023 \ERSTCO SCUPPER WITH COATED METAL THERMOPLASTIC REINFORCED MEMBRANE THERMOPLASTIC ROOFING SYSTEM - APPRO\€D SUBSTRATE 0 _ SEE NOTE(S)TPC_ 18.1 -l I I MlN. 2" (5cm) TTHERMOPLASTIC M EMBRANE APPLICABLE BONDING ADHESIV-E REFER TO APPLICABLE DETATL(s) rN LATEST EDITION OF SMACNA VERSICO UNIVERSAL SINGLE_PLY SEALANT TWO LAYERS OF VERSIGARD WHITE QUICK-APPLIED UNCURED EPDM FLASHING WTH EPDM OR TPO PRIMER. FIRST LAYERS 6'' (ts.scm) AND sEcoND LAYER 12" (25.4cm) WIDE rln TPO I I I I I+1 I a. ISHEET METAL SCUPPER (BY oTHERS) MlN. 2" (5cm) SEALANT (BY OTHERS) NOTES: 1. WOOD NAILERS ARE INSTALLED AT SCUPPERS TO SECURE METAL SLEEVE AND MUST EXTEND PAST THE WDTH OF METAL SLEEVE FLANGE. 2. METAL SCUPPER BOX MUST HAVE CONTINUOUS FLANGES WTH ROUNDED CORNERS, SOLDER ALL SCUPPER SEAMS WATER_TIGHT. 3. WATER CUT-OFF MASTIC UNDER SCUPPER FLANGES MUST BE UNDER CONSTANT COMPRESSION. 4. UNIVERSAL SINGLE-PLY SEALANT IS REQUIRED AT FLASHING EDGES ON SCUPPER EDGE. TPO PRIMER MUST BE USED TO PREPARE SURFACES PRIOR TO THE APPLICATION OF SEALANT. L 4 2 wooD NATLER (BY OTHERS) 1 I I J WATER CUT_OFF MAST]C XXX 3 3RD 2ND '7 1ST 5fi 5TH 4lH THERMOPLASTIC ROOFING SYSTEM - -'IPO MEMBRANE - APPRO\ED SUBSTRATE _ sEE NoTE(s)0 TPC _18.2SCUPPER AT DECK_TPOVERSICO ROOFING SYSTEMS o 2023 \ERS|CO I TH ER M OP LASTIC MEMBRANE REFER TO APPLTCABLE DETATL(S) IN LATEST EDITION OF SMACNA SHEET METAL SCUPPER (BY oTHERS) SEALANT (BY OTHERS) NOTES: WOOD NAILERS ARE INSTALLED ONLY AT SCUPPERS TO SECURE METAL SLEEVE AND MUST EXTEND PAST THE WDTH OF METAL SLEEVE FLANGE. 2. METAL SCUPPER BOX MUST HAVE CONTINUOUS FLANGES WITH ROUNDED CORNERS, SOLDER ALL SCUPPER SEAMS WATER_TIGHT. 3. WATER CUT-OFF MASTIC UNDER SCUPPER FLANGE MUST BE UNDER CONSTANT COMPRESSION. 4. SCUPPER FLANGES MUST BE TOTALLY covERED BY NON-REINFORCED PVC/KEE HP FLASHING WITH MINIMUM 2" (scm) COVERAGE PAST NAIL HEAD. 5. UNIVERSAL SINGLE_PLY SEALANT IS REQUIRED AT FLASHING EDGES ON SCUPPER EDGE. VERSIFLEX BONDING ADHESIVE - - - VERSICO UNIVERSAL SINGLE_PLY SEALANT VERSIFLEX NON- REINFORCED FLASHING Pvc/ KEE HP - HOT AIR WELD, 1-1 /2" (acm) MlN.c'r*ffit L I 4 .l I I 4 'l (BY oTHERS) WOOD NAILE5 I I J XXX WATER MASTIC CUT_ 5 a THERMOPLASTIC ROOFING SYSTEM TP C _ 1 B. J--rufi/rJl._?'" ffiif,E-]T+]Tl - AppRovED suBSTRATE 0 - sEE NoTE(s) vVERSICO SCUPPER AT DECK_PVC/KEE HPilROOFING SYSTEMS @ 2023 VERSTCO