HomeMy WebLinkAboutConditions of PermitCONDITIONS OF P ERMIT
BLRE-06-24-87 55
Jeremy & Gloria Keranen
954 SO FT Accessory Dwelling Unit (ADU)
WITH ATTACHED 1 ,414 SO FT GARAGE
449 Ram Lane, Silt
Piffer Sub Div Exemption, Lot 4 - 212532200199
1) ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE (I.R.C.)
AND 2O1B INTERNATIONAL ENERGY CONSERVATION CODE (I.E.C.C.)
2) PROPOSED TMPROVEMENTS ARE SUBJECT TO ALL APPLTCABLE |TEMS CONTAINED lN THE
ATTACHED "GARFIELD COU NTY BU I LDING REOUIREMENTS". NUM BER REFERENCES
NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) ELECTRTCAL pERMtTTtNG AND TNSPECTTONS BY COLORADO STATE ELECTRIC BOARD.
ELECTRICAL ROUGH.IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL
FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.
4) ALL EXTERIOR LIGHTING TO BE DOWNCASTAND SHIELDED.
S) WILDFIRE MITIGATION RECOMMENDATIONS: SHALL COMPLY WITH WILDFIRE MITIGATION
AND DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE FOREST SERVICE
AND LOCAL FIRE DISTRICT. PLEASE REFER TO THE GARFIELD COUNTY COMMUNITY
DEVELOPMENT WEBSITE FOR ADDITIONAL I NFORMATION.
6) OPEN HOLE SOTLS REPORT rS REOUTRED AT FOOTTNG TNSPECTION AND PRrOR TO ANY
CONCRETE POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE
BUILDING INSPECTOR. 2,OOO PSF AS SPECIFIED BY THE GEOTECH.
7) SEPTIC SYSTEM REVIEW / APPROVALS: PRIOR TO FINAL BUILDING INSPECTION &
CERTIFICATE OF OCCUPANCY PROVIDE FINAL APPROVAL /SIGN-OFF FROM GARFIELD
COUNTY'S PUBLIC HEALTH DEPT.
8) CONTRACTOR SHALL ENSURE ADU i GARAGE FrRE SEPARATTON lS INSTALLED PER 2015
IRC TABLE R302.6.
9) A LOT TMPROVEMENT CERT|F|CATE, SEALED BY A COLORADO LICENSED SURVEYOR, lS
REOUIRED AT FOUNDATION INSPECTION TO VERIFY STRUCTURE _ INCLUDING PROPOSED
ROOF OVERHANGS AND OTHER PROJECTIONS _ IS IN COMPLIANCE WITH GARFIELD
COUNTY LAND USE DEVELOPMENT CODE AND RURAL ZONE DISTRICT 1O FT SIDEYARD
SETBACK.
10) BLOWER DOOR TEST tS REOUTRED FOR THE ADU. MUST SUBMIT BLOWER DOOR TEST
REPORT TO GARFIELD COUNry COMMUNITY DEVELOPMENT DEPT. OFFICE PRIOR TO
SCHEDULING FINAL BUILDING INSPECTION / C.O. FINAL.
1 1 ) PRESCRIpIVE PATH WtrH 2018 tECC TABLE R402.1.2 HAS BEEN CHOSEN FOR ENERGY
COMPLIANCE OF THE HOME DESIGN. MANUAL J LOOP CAD 2023 report has been
scanned into Laserfiche. ALL NEW HOMES TO HAVE WHOLE-HOUSE MECHANICAL
VENTILATION SYSTEM INSTALLED (2015 IRC TABLE m1507.3.3(1)AND (2)AS STAMPED ON
covER sHEET)