Loading...
HomeMy WebLinkAboutObservation of Excavation 05.02.2024I(tA lfumr & Asoclates,lnc. 6-Jolecln,cal an-O ntateri6ls Engineers 5020 County Road 154 and Environmental Scientists - Glenwood Springs, CO 81601 phone: (970) 945-7988 fax: (970) 945-8454 email: kaglenwood@kumarusa.com An Emdoyac owngd compony wwvv.kumarusa.com Office Locations: Denver (HQ), Parker, Colorado Springs, Fort Collins, Glenwood Springs, and Summit County, Colorado N'{:ay 2,2024 Brackett Pollard Attn: Jonathon Todd 6875 County Road 233 Silt, Colorado 81652 jontoddbja@gmail.com Project No.24-7-246 Subject: Observation of Excavation, Proposed Addition, 6875 County Road 233, Garfield CountY, Colorado Dear Mr. Pollard: As requested, a representative of Kumar & Associates observed the excavation at the subject site on April 26,2024 to evaluate the soils exposed for foundation support. The findings of our observations and recommendations for the foundation support are presented in this report. The services were performed in accordance with our agreement for professional engineering services to you dated April 17,2024. The proposed construction will be a 12 feet by 14 feet addition on the southwest corner of the existing residence. Foundations consist of spread footings designed for an allowable soil bearing pressure of 2,000 psf. At the time of our visit to the site, the foundation excavation had been cut in one level about 3 feet below the adjacent ground surface. The soils exposed in the bottom of the excavation consisted of very stiff sandy silty clay. Results of swell-consolidation testing performed on samples taken from the site, shown on Figures 1 and 2, indicate the soils are compressible under conditions of loading and wetting. No free water was encountered in the excavation and the soils were slightly moist to moist. Considering the conditions exposed in the excavation and the nature of the proposed construction, spread footings placed on the undisturbed natural soil designed for an allowable soil bearing pressure of 2,000 psf can be used for support of the proposed addition. The exposed soils tend to compress when wetted and there could be some post-construction settlement of the foundation if the bearing soils become wet. Footings should be a minimum width of 16 inches for continuous walls and2 feet for columns. Loose and disturbed soils in footing areas should be removed and the bearing level extended down to the undisturbed natural soils. Exterior footings should be provided with adequate soil cover above their bearing elevations for frost protection. Structural fill ptaced within floor slab areaS can consist of the on-site soils compacted to at least 95% of standard Proctor density at a moisture content near optimum. Backfill placed around the structure should be compacted and the surface gfaded to prevent ponding within at least 10 feet of the building. Brackett Pollard May 2,2A24 Page2 The recommendations submitted in this letter are based on our observation of the soils exposed within the foundation excavation and do not include subsurface exploration to evaluate the subsurface conditions within the loaded depth of foundation influence. This study is based on the assumption that soils beneath the footings have equal or better support than those exposed. The risk of foundation movement may be greater than indicated in this report because of possible variations in the subsurface conditions. In order to reveal the nature and extent of variations in the subsurface conditions below the excavation, drilling would be required. It is possible the data obtained by subsurface exploration could change the recommendations contained in this letter. Our services do not include determining the presence, prevention or possibility of mold or other biological contaminants (MOBC) developing in the future. If the client is concerned about MOBC, then a professional in this special field of practice should be consulted. If you have any questions or need further assistance, please call our office. Sincerely, H{. ir c; E ;t r r,* A :.:l+t;t:i :,it s-'.'lu Ewc" Staff Engineer Reviewed by: Robert L. Duran, P SMMlkac attachments Test ResultsFigures I 6t3U2 tloel e Kumar & Associales, lnc. o Projeet No.24-7-246 I SAMPLE OF: Sondy Sllty Cloy FROM: Boltom of Excovotlon ot West Slde Wc = 10.6 %, DD = 99 pcf iiii ilri | .- i.- 1iii.i.-i.iirl i I i i l l i ! I I ADDITIONAL COMPRESSION UNDER CONSTANT PRESSURE DUE TO WETTING ! i I.' I i I I I l iLli ri l ii1j ilti l 0N j-1 lrt =a t_2 zotr $-sonzotr-4 - KSF1.0 Fig. 1SWELL-CONSOLIDATION TEST RESULTS24-7-246 Kumar & Associates I SAMPLE OF: Sondy Sllty Cloy FROM: Bollom of Excovollon qt South Slde WC = 10.7 %, DD = 100 pcf I I I I lI I l I I I-j 1 lri -r ADDITIONAL COMPRESSION UNDER CONSTANT PRESSURE DUE TO WETTING 0 N j-1 LJ =lr7 t_2 z.otr S-souzoo-4 - KSF,1 Fig. 2SWTLL-CONSOLIDATION TEST RESULTS24-7-246 Kumar & Associates