HomeMy WebLinkAboutOWTS Permit SEPT-8070 Renewed
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 306 County Road 304, Parachute, CO 81635
Parcel No.: 240703400010
Owner Name: Rick and Jennifer Jablonsky Owner Phone: (970) 948-5077
Contractor Name: Rick and Jennifer Jablonsky Contractor Phone: (970) 948-5077
Designed By: SGM, Inc. Designer Phone: (970) 384-9005
Number of Bedrooms _3__Minimum Tank Capacity _1,000-gal__Minimum Absorption_1,575 SF
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT-8070_Renewed_______________________
Permit Type X New X Repair X Remodel/addition X Tank only X Field Only X Amendment
Issue Date: 08/16/2024 Expiration Date: 08/16/2025
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the design as submitted by SGM,
Inc. dated September 8, 2021 and design revision letter dated May 16, 2024. Changes must be
approved by Garfield County Public Health and the designer prior to construction.
The new OWTS will serve a new 3-bedroom residence. The system will consist of a new, two-
compartment 1,500-gallon septic tank set level with access to the compartments provided at grade
and an effluent filter in the outlet tee of the tank. Effluent will gravity flow to a distribution box set
level with access provided at grade that will distribute effluent to 1,584 ft2 of STA. The new STA will
consist of six gravelless chamber trenches with 22 Quick4 chambers per trench (132 Quick4
chambers total). Inspection ports shall be installed at the terminal end of each trench. Maintain all
setbacks and elevations as designed.
To assist in scheduling, please contact Garfield County Public Health (970-945-6614 ext. 8150) to
notify the start of OWTS construction. Contact the designer and Garfield County Public Health at
least 48 hours prior to requesting final inspection of the installed system prior to backfill. NO OWTS
COMPONENT SHALL BE BACKFILLED WITHOUT PRIOR APPROVAL FROM GARFIELD COUNTY PUBLIC
HEALTH AND THE DESIGNER.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as-built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
08/16/2024
Issued By: Garfield County Environmental Health
Department
Date