HomeMy WebLinkAboutBlower Door TestarEhitecture r sLtstainability
Reside ntial Air lnfiltration Tesf Report
lltll Village Road UL-lD Carbondale. In BlE23
S70.883.872[ www.confluencearchitecture.com
Cubic Feet
CFM50 Cubic Feei per Minuie ol 50 Poscol
Test dole:
Project nome:
Address:
Code:
Conditioned volume:
Attic:
Crowlspoce:
Goroge:
Meosured oirflow:
Temperofure; lnside:
Temperoture; Ouiside:
Elevotion:
Conected oirflow:
20l5IECC moximum ollowed leokoge roie:
Tested oir leokoge rote:
Test code complionce:
B/212024
Alionogo
428 Diqmond A Ronch Rood Eost
GorCo
2OIB IECC
55,O22
non-venled
conditioned
excluded
2,O82
6B
75
6,075
2,177
3.0
2.4
PASS
cFM50*
ACH50
ACH50
Cubic Feet per Minute oi 50 Poscql
Air Chonges Per Hour ot 50 Pqscol
Air Chonges Per Hour qt 50 Pqscol
Tests were performed by Chris Toylor; Roted Field lnspector, RFIIN #CYSMPL
* Test resulls hqve been corrected for elevqtion ond oir densily lemperoture differentiql.