HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT
BLCO-06 -24-87 10
ALBERTO PIZARRO
STORAGE BUILDING WITH ATTACHED OFFICE
TBD COUNTY ROAD 236
SILT, CO
1) THE WAREHOUSE rS BE|NG PRESENTED AS STORAGE ONLY. lF A WOOD SHOP lS
CREATED, AUTOMATIC FIRE SPRINKLERS ARE REQUIRED FOR WOOD SHOPS OVER
2500 so. FT.
2) THE APPROVED PLANS ARE TO BE ON-SITE FOR INSPECTIONS.
3) SANTTARY FACTLTTES ARE REOUIRED TO BE PROVIDED FOR WORKERS.
4) A L|ST OF REOUTRED TNSPECTTONS rS ATTACHED TO THE PLANS. THE STATE lS TO
PERMIT AND APPROVE THE ELECTRICAL WORK.
HTTPS ://WWW.CO LORADO.G OV/PACI FIC/DORA/DPO ELECTRI CAL PLU M B I NG PE
RMITS
5) UNDERGROUND UTlLtTy LOCATES rS THE RESPONSTBTLTry OF THE OWNER OR
CONTRACTOR. 811 IS THE COLORADO UTILIry LOCATE HOT LINE.
6) DRAINAGE ACROSS PROPERry LINES SHALL NOT EXCEED THAT WHICH EXISTED
PRIOR TO GRADING. EXCESS OR CONCENTRATED DRAINAGE SHALL BE
CONTAINED ON SITE OR DIRECTED TO AN APPROVED DRAINAGE FACILIry.
EROSION OF THE GROUND IN THE AREA OF DISCHARGE SHALL BE PREVENTED BY
INSTALLATION OF NON-EROSIVE DOWN DRAINS OR OTHER DEVICES.
7) ALL BACKFLOW PREVENTERS ARE REOUIRED TO BE TESTED AND CERTIFIED BY A
LICENSED BACKFLOW SPECIALIST AFTER INSTALLATION AND PRIOR TO ISSUANCE
OF THE CERTIFICATE OF OCCUPANCY.
B) SEPARATE SIGN PERMITS ARE REOUIRED FOR ANY EXTERNAL SIGNS. PLEASE
CONTACT THE COUNTY WEBSITE FOR THE APPLICATION.
9) ELECTRICAL CODE COMPLIANCE WILL BE DETERMINED BASED ON FIELD
INSPECTIONS PERFORMED BY THE STATE ELECTRICAL INSPECTOR, (303) 869-3458.
PLEASE HAVE THE INSPECTOR SIGN THE BUILDING CARD OR PROVIDE WRITTEN
DOCUMENTATION OF THE INSPECTIONS.
1O)THE ELECTRICAL CODE REOUIRES A SEPARATE ELECTRICAL PERMIT FOR LOW
VOLTAGE FIRE ALARMS THAT HAS AN ALARM PANEL AND SEND A NOTIFICATION
TO THE FIRE DISTRICT WHEN UNDER ALARM. A ROUGH-IN INSPECTION WITH THE
srATE ELECTRTCAL tNSPECTOR rS REOUTRED (303)869-3458. PLEASE HAVE THE
ELECTRICAL INSPECTOR SIGN THE BUILDING CARD OR PROVIDE WRITTEN
DOCUMENTATION OF THE INSPECTION.
11) PLEASE PROVIDE SPECIAL INSPECTIONS REPORTS TO THE BUILDING
DEPARTMENT, WELDING AND BOLTING IS MINIMUM.
12)GEOTECHNICAL OBSERVATION lS REQUIRED WHEN THE EXCAVATION lS
COMPLETE AND WRITTEN VERIFICATION BE SUPPLIED AT FOOTING INSPECTION,
1 500PSF.
13)ALL EXTERTOR LIGHTING lS TO BE DOWNCAST AND SHIELDED.
14)SAFEry GLAZING IS NOT DESIGNATED ON THE PLANS. SAFETY GLAZING WILL BE
cHECKED DURING THE FRAMING AND FINAL INSPECTION. (lBC 2406.4)
15)ANY MEMBRANE AND THROUGH PENETRATIONS OF THE FIRE RESISTIVE
CONSTRUCTION WILL BE REOUIRED TO BE FIRE-STOPPED WITH LISTED FIRE
STOPPING ASSEMBLIES. THE CONTRACTOR IS TO PROVIDE A CUT SHEET FOR THE
ASSEMBLIES AT THE FRAMING INSPECTION. (lBC 713)
16)A KNOX BOX tS REOUTRED TO BE MOUNTED ADJACENT TO THE FRONT DOOR.
PLEASE CONTACT THE LOCAL FIRE DISTRICT FOR EXACT LOCATION.
17)THE WALLS SURROUNDING THE TOILET ARE TO BE NON-ABSORBENT FOR A
HEIGHT OF 48" AND 2' PAST ON EACH SIDE OF THE TOILET.
18)ALL ACCESSIBLE DOOR HARDWARE SHALL HAVE A SHAPE THAT IS EASY TO GRIP,
TNCLUDTNG POCKET AND SLIDING DOORS. (ANSI A117.1 - 404.2.6)
19)GRAB BAR BACKING lS TO BE lN PLACE FOR ALL TOILETS AT FRAMING
INSPECTION.
20) A pASStNG BLOWER DOOR TEST FOR THE OFFTCE lS REOUIRED TO BE SUBMITTED
PRIOR TO ISSUING THE CERTIFICATE OF OCCUPANCY.
21)DOORS 102 AND 104 ARE REOUTRED TO BE SELF-CLOSING OR AUTO-CLOSING.
THERE ARE CHALLENGES WHEN AUTOCLOSURES ARE REOUIRED ON DOUBLE
DOORS.
22)R-10 SLAB EDGE TNSULATTON rS REOUTRED AROUND THE PERIMETER OF THE OF
THE HEATED SPACE.
23)ALL FOAM TNSULATTON tS TO BE SEPARATED FROM OCCUPIABLE SPACE WITH A
THERMAL BARRIER AND SEPARATED FROM AN ATTIC BY AN IGNITION BARRIER.
2 )ELEVATE ALL SOURCES OF IGNITION 18" ABOVE THE FLOOR INSIDE THE
WAREHOUSE, AS VEHICLES CAN BE PULLED INSIDE.
25)WATER STORAGE AND SITE ACCESS FOR EMERGENCY OPERATIONS IS TO BE
APPROVED BY THE LOACAL FIRE DISTRICT PROIR TO OCCUPANCY.