Loading...
HomeMy WebLinkAboutApplicationGarfield County ,. CommunityDevelopment Department 108 8th Street, Suite 401GA'l cbnrrt'6STYorines. Co 81601 C0h1i,,, ,;, i ; ;. jl Vil.Cpp?tfg qi_Aaf- www.qarfield-cou ntv.com RE TYPE Commerci ulti-Fami Demolition {jl..u d d ,p gme (singl e -o r .l!! ulti1levgl) lex or Townhom Unit AD - MAXIMUM SIZE OF Reroof FEET BUILDING PERMIT APPLICATION INVOLVED PARTIES Property Owner:James M. Mindling Family Trust phone: ( 2O3 t 216-14?B MailinB Address: 32 Buttonball Lane Weston CO 06883 Emait Address: mindling@gmail. com Contractor:Phone:(970 t 309-7155 Mailing Address: 3098 Meadowview Lane. Baslat. CO 81621 Email Address:nalri ck (D,ma larrhr r i ld inn r:nm Architect: KA-Designworks Phone: (€74-) 948-9510 Mailing Address Email Address: 525 BasaltAve., Basalt, CO 81621 Engineer:Rirrerqfnna Sfrr rntr I /-annan{c Mailing Address:7154W. State St.. Ste 297. B Class of Work: Garage: Phone: (fl!_l 343-21192 tD 83714 Emait Addressr jake@riverstonesc. com Manufactured Home lnstaller: N/A Phone: Mailing Address Email Address: PROJECT DETAITS Describe work: A new 2-story 625 sq. ft. accessorv dwellinq unit in the Finnbar subcjivisio n of Garfield Cou ntv over a 699 so. ft. two-car oaraoe JobAddress: 30 St. Finnbar Road, Carbondale, CO 81623 Assessor's Parcel Numbe r: 239131318007 sub. Finnbar Farms Lot 07 Btock Owne/s Valuation of Work:(Property Size (Sq. Ft. or Acres):12.36 ac. Sq. Ft. of Building:I 3?4 Height:25'S of Floors: 2 Addition Attached n Remodel/Alteration Detached tr nity ctric I II ural Gas ne Oriveway Septic Type of Heat: Permit: Authoritv. ThisapplicationforaBuildingPermitmustbesignedbytheOwneroftheproperty,describedabove, oranautho.izedagent. lfthesignaturebelowisnotthatoftheOwner,aseparateletterofauthority,signedby the Owner, must be provided with this Application. legal Access. A Building Permit cannot be issued without proof of legal and adequate access to the property for purposes of inspections by the Building Division, Other Permits. Multiple separate permits may be required: {1) State Electrical Permit, {2} County OWTS Permit, {3) another permit required for use on the property identified above, e,g. State or County Highway/ Road Access or a Stale Wastewater )ischarge Permit, Void Permit. A Building Permit becomes null and void if the work authorized is not commenced within 180 days of the date of issuance and if work is suspended or abandoned for a period of 180 days after commencement. I hereby certiiy that I have read this Application and that the lnformation contained above is true and correct. l understand that the Suilding Division accepts the Application, along with the plans and specifications and other data submitted by me or on my behalf {submlttals), based upon my certification as to accuracy. Assuming completeness of the submittals and approval of this Application, a Building Permit will be issued granti:tg permission to me, as Owner, to conslruct the structure{s) and facilities detailed on the submittals reviewed by the Building Division. ln consideration of the issuance of the Building Permit, I agree that I and my agents will comply with provisions of any federal, state or local law regulating the work and the Garfield County Building Code, OWTS regulations and applicable land use regulations (County iegulation(s)). All County development requiring a permit, except for residential uses are subject to Article ? of the Land Use and Development Code, I acknowledge that the Buildin6 Permit may be suspended or revoked, upon notice from the County, if the location, construct:on or use ol the structure{s) and facility(ies}, described above, are not in compliance with County Regulation{s) or any other applicable law. I lrereby grant permission to the Building Division to enter the property, described above, to inspect the work. I furtlrer acknowledge that the issuance of the Building Permit does not prevent the Building Offlcial from: (1) requiring the correction of orrors in the submittals, if any, discovered after issuance; or {2} stoppinB construction or use of the structure{s) or facility{ies} if such is in violation of County Regulatlonis) or any other applicable law' Review of this Application, including submittals, and inspections of the work by the Building Division do not constitute an acceptance o{ responsibility or liability by the County of errors, omissions or discrepancies. As the Owner, I acknowledge that responsibility for compliance with federal, state and local laws and County Regulations resl with me and my authorized agents, including wilhout limitation mY alchitect designe r, engineer and/ or builder. : I p hereby acknowledge that I have read and und€rstand the Notice and Certification above, as well a5, have required information whlch is cerrect and accurate to the best of my knowledge. ?/-u /*3 Property Ownar Print and Sign Date €ec atte*ea/ aMb/valusSpecial Conditions: Fees:Manu. Home Fee:|\/AoTh'X,'25ury:aw:b4 -56qit{rr OWTS No:ffiu-t33.lI /? I '56q'.1{rl Balance Oue;-,/ 7gv, lo '"flt'Const. Type: ROGroup: BUITD|NG / pLANNING DIVISION Signed Approval I 6-28-fu2 Date ENERGY COMPLIANCE SHEET REQUIREMENTS: Effective June 30, 2023 Please provide details showing how building complies / meets Garfield County's adopted 2018 IECC and Slig1g!g-3ogg-1 Depict and show oulline the structure's building thermal envelope. Outline should clearly show portions of the building to be conditioned inside the envelope (and label or othenruise identify any areas remaining unconditioned outside this envelope) Energy Compliance Plan should fufiher include: Chosen Fnergy Compliance Path. Prescriptive: Cross Sections of insulated assemblies including the selected matedal / R-Value and U-Values to comply with IRC Tabls R402.1.2 r U-FacJor Alternative: Provide a ResCheck Report r Total U-Factor Alternalive: Provide soflware generated submittal design reporls and inspection checklist for any RESNET ERI index ot other performance path designs Air sealing details around openings, pipes, penetrations, joints Fenestration U-factors Provide mechanical system design details including proposed efficiency rates, types of equipment, fuel types, locations Energy efficient lighting specificatiorrs - 90% to be high-efficacy (LED complies) Manual J Report required for new building structures and new equipment installations. STRUCTURAL PLAN$: Please provide the following information on the structural plans. . SOILS,REPORT - lf the project is located in a subdivision with a final plat requiring site specific soils investigation report or if Struciural plans make a specific reference to a sails report, then a copy ol the soils report is required to submit a building permit application. r Design specifications to include roof and deck snow load, wind and seismic design and frost depth.. Foundation plan showing complete footing and foundation dimensions. r Footing and foundation details speci{ying reinforcement and referenced on plans. . Framing plans for each floor level and roof. All beams, columns, joists, rafters and trusses specified. Pre-manufactured structures require lhe engineers stamp, signature and date. . Framing /connection details, braced wall lines, shear wall schedule, location and hold downs. NOTE: lf any required information is missing, delays in issuing the permit are to be expected. lf determined by the Building Official that additional information is necessary to review the application and/or plans for compliance, the application may be placed on hold until the required information is provided. Work may not proceed without the issuance of a permit. The Building Division will collect a Plan Review fee at time of application submittal. The permit fee, as well as any Road lmpact fees will be collected when the permit is issued. The permit application must be signed by the owner or by person having written authority from the owner to act as their representative. Building cannot be occupied until a Certificate of Occupancy (CO) is issued. Using the building without a CO will be considered an illegal occupancy and may be grounds for vacating the premises. (Final/CO inspection requirements will be attached to your approved field set of plans.) I hereby acknowledge I have read, understand and will abide by the requirements of this checklist. owner print: fl f\ -fvl i a dl r A? €* sig \- Date q Gurfield County BUILDING DEPARTMENT 708 Eighth Strcet, Suite 401, Glenwood Springs, CO 81607 Tel: (970) 945-8272 PLAN REVIEW C HECKLIST Permit no: $!a(p-?/-pE-8 ggy' Building lssues Planning/Zoning lssues @pu_c4.a/O,-7lhnu / Engineered Foundation ) /-rc),eeMe/ ewpt_ // /t/ CoN.D ^/4 Driveway Permit Surveyed Site Plan Septic Permit and Setbacks Grade/ Topography 30% Attach Residential Plan Review List Subdivision Plat Notes Fire Department Review Valuation Determination/ Fees Red Line Plans/ Stamps/ Sticker Attach Conditions pplication Signed Parcell Schedule No. 40# Snowload Letter - Manuf. Homes roperty Line SetbacksW- AaL .-Building Height Zoning Sign-Off Grade/ Topography 40% - Planning tssues - subdivision Plate7/Z/ -.-- Kt rasD Descri on&Summa 35 ft. Stream Setbacks Ftood Ptain f r/ioar/ 2/? d/,rc- @Road rmpact Fees Rt n EED eA/D soirs Report ,(ariew re4eb de/4/%/ Fls ozt x 4,66= /b" b76 oo 1.1* bflx "VZ = Z 1n4,oo afae,b-//,*//n ra/4ab>z $vzt a/3,@6? btt above ahlaru?*-,S7arahP ryz /