HomeMy WebLinkAboutCorrespondence<Bu il,d ing Code Requirements - Residentiat.pdf> / Good Morning, Here are the answers to your questions K*;re/ B'27-ZZf 1.1 have attached updated heat loads. 2. We are using 2018 IECC Perspective path tabte R4O2.1.2 However we are insulation better than code requirements. See insutation sheet attached. 3.Exhaust fans on[y. 4. Attached a wa[[ section showing insutation and catting out attic and craw[ as unconditioned. S.There wil,t be NO LP equipment located in attic or crawtspace. 6.PLease disregard the pl.an detaitcal,ting out attic access. Truss are not load bearing and there witt NOT be any storage or tiving space above gage. Regards, ,Jose Gonzatez J Cal.iber Construction (970)314-0489 Jose@jca [i be rconstruction.com $ N $ \l \ BUE-17-2h-87W Salinas, Jesus E Belen SEFt-07-24-879s S/F E ZTltllinsta0r, Sih MlllEIlTA RIDEE ESI SRD' bt 3 PrfZ79l33ll074tl 3 Colleen Wirth From: Sent: To: Cc: Subject: Attachments: Follow Up Flag: Flag Status: Jose Gonzalez <jose@jcaliberconstruction.com > Thursday, August 29,2024 8:46 AM Colleen Wirth salinasjesus23@gmail.com; Mic Bacca; John Plano; Teresa Bianco Re: BLRE-O7-24-8794 - Salinas SFR2276 Mineota Dr is now UNDER REVIEW Salinas Heatload.pdf; Wal I sectioninsulation.pdf Follow up Flagged On Aug 19,2024, at 10:00 AM, Cotteen Wirth <cwirth@garfietd-county.com> wrote BLRE-O7-24-8794 - Salinas SFR 2276 Mineota Dr Courtesy Message for Satinas residentiaI project team: l'm finishing initiat code review for your residential, appl,ication / btueprints and have a few questions or correctionsbefore I finish stamping and issue the pl,an case: GORREGTIONS / QUESTIONS AS FOLLOWS: With regard to the EMS HVAC Load Catcutator dated 7/17/2024, the report [ists a WINTER outdoor temperature of 32 degrees. Garfiel,d County's WINTER DESIGN TEMPERATURE for sites with etevation at 5,625 ft = MINUS 2 degrees F. Please re-check the toad cal,cutations and proposed equipment parameters and resubmit a REVISED report demonstrating comptiance with Garfietd County's Local.ty adopted buitding code amendments. (adopted WINTER DESIGN TEMPERATURE incLuded in the attached PDF.) 2. White the architecturat cover sheet states "energy and insutation per 2018", it is unknown or unclear what ENERGY COMPLIANCE PATH lS CHOSEN? Some architectural references on the cover sheet list Southe rn Louisiana. 2.a. Areyou designing and instal,ting buitding assembties in accordance with 2018 IECC PRESCRIPTIVE PATH, TABLE R402.1.2? 2.b. Are you instaLl.ing in accordance with the 2018 IECC PRESCRIPTIVE PATH using UA tradeoffs and a RESCheck Report? lf so, ptease submit your RESCheck Report.... 2.c. Are you instal.l,ing in accordance with an 2018 IECC PERFORMANCE PATH using a HERSRater or other? lf so, ptease submit the performance software report prepared by the rater or energy professionat. 3. What method of WHOLE-HOUSE VENTILATION are you proposing for this home design? 3.a. Exhaust onty fan system(s)? 3.b. Combination system with ERV or HRV? lf so, where is the equipment being instatted? 4. No graphic depiction of the BUILDING THERMAL ENVELOPE or outtine of the insutated conditioned spaces was found on prints. Ptease submit a supptementaI ptan page (cross section) or other cut sheets clearly il,tustrating the outtine of al,t conditioned spaces and ctearty [abet, if any unconditioned spaces (such as unconditioned attic space, unconditioned garage attic, unconditioned crawt space, unconditioned room accessed off the garcge, unheated unconditioned garage space??? etc) 5. As this property witt be served by LP propane fuettype, can you confirm IF any propane fuet fired apptiances or equipment witl, be instatted in the craw[ space. lt woutd be most he[pfut to receive something in writing from the buitder indicating whether or not any equipmentwil,l, be ptaced in the crawl space, thank you! 6. Architectural sheet 41.0 depicts a 20- minute attic stair in the garage Lid. 6.a. What is the proposed or intended use of the garage attic? Non-habitabte garage storage on[y? Unfinished future residentiat tiving space or other? 6.b. No attic access opening is graphicatty depicted in the garcge on Studio M S3.0 and S.4 sheets? Want to ensure there's no field cutting / compromising of the engineered truss layout. Request the structuraI engineer of record verify attic access nnanind nn A "i ft ia namna+il-ri^ ..'i+1^ +tr^ ^+^'+r^aA a+vr.^+. '-^i ahaa+avyvr rrr 15 vr r n r .v ro uvr r rPqLrurs vvrLr r Lr rE or,clt I tPE;tl DLt (ltJLtlt clt ot tE;E;Lo. 6.c. lF garcge storage use is the intended function of the garage attic, wit[ ENGINEERED STORAGE TRUSSES be insta[Ied? 6.d. lF future habitabte Living space in intended function of the attic accessed above the garage, then ptease remit an architecturaI ftoor ptan detail, for the future space and confirm ENGINEERED TRUSSES witt be suppl,iecj to accommodate future residential Living. Ptease respond to questions 1-6 above by email, to Cotteen Wirth, Plans Examiner, cwirlh@€arfie-[d--county.com. Where fut[ size sheets for supptementaI detaits pertain, ptease submit to the Garfietd County Community Devetopment Dept front desk in downtown Gtenwood Springs, (2) FULL SIZE paper copies reference BLRE-07-24-8794 SALINAS, c/o Cotteen Wirth Ptans Examiner. Thanks for your care with this project -- I took forward to seeing the project move forward, Cotleen Wirth Buitding Plans Examiner Garfleld County Community Development 108 8th Street, Suite 401 (970) 945-1377 ext 1610 cwirth @ga rf ietd -cou nty. co m 2