HomeMy WebLinkAboutCorrespondence<Bu il,d ing Code Requirements - Residentiat.pdf>
/
Good Morning,
Here are the answers to your questions K*;re/ B'27-ZZf
1.1 have attached updated heat loads.
2. We are using 2018 IECC Perspective path tabte R4O2.1.2 However we are insulation better than
code requirements. See insutation sheet attached.
3.Exhaust fans on[y.
4. Attached a wa[[ section showing insutation and catting out attic and craw[ as unconditioned.
S.There wil,t be NO LP equipment located in attic or crawtspace.
6.PLease disregard the pl.an detaitcal,ting out attic access. Truss are not load bearing and there witt NOT
be any storage or tiving space above gage.
Regards,
,Jose Gonzatez
J Cal.iber Construction
(970)314-0489
Jose@jca [i be rconstruction.com
$
N
$
\l
\
BUE-17-2h-87W
Salinas, Jesus E Belen SEFt-07-24-879s
S/F E ZTltllinsta0r, Sih
MlllEIlTA RIDEE ESI SRD' bt 3 PrfZ79l33ll074tl
3
Colleen Wirth
From:
Sent:
To:
Cc:
Subject:
Attachments:
Follow Up Flag:
Flag Status:
Jose Gonzalez <jose@jcaliberconstruction.com >
Thursday, August 29,2024 8:46 AM
Colleen Wirth
salinasjesus23@gmail.com; Mic Bacca; John Plano; Teresa Bianco
Re: BLRE-O7-24-8794 - Salinas SFR2276 Mineota Dr is now UNDER REVIEW
Salinas Heatload.pdf; Wal I sectioninsulation.pdf
Follow up
Flagged
On Aug 19,2024, at 10:00 AM, Cotteen Wirth <cwirth@garfietd-county.com> wrote
BLRE-O7-24-8794 - Salinas SFR 2276 Mineota Dr
Courtesy Message for Satinas residentiaI project team:
l'm finishing initiat code review for your residential, appl,ication / btueprints and have a few
questions or correctionsbefore I finish stamping and issue the pl,an case:
GORREGTIONS / QUESTIONS AS FOLLOWS:
With regard to the EMS HVAC Load Catcutator dated 7/17/2024, the report [ists a
WINTER outdoor temperature of 32 degrees. Garfiel,d County's WINTER DESIGN
TEMPERATURE for sites with etevation at 5,625 ft = MINUS 2 degrees F. Please
re-check the toad cal,cutations and proposed equipment parameters and resubmit
a REVISED report demonstrating comptiance with Garfietd County's Local.ty adopted
buitding code amendments. (adopted WINTER DESIGN TEMPERATURE incLuded in
the attached PDF.)
2. White the architecturat cover sheet states "energy and insutation per 2018", it is
unknown or unclear what ENERGY COMPLIANCE PATH lS CHOSEN? Some
architectural references on the cover sheet list Southe rn Louisiana.
2.a. Areyou designing and instal,ting buitding assembties in accordance with 2018
IECC PRESCRIPTIVE PATH, TABLE R402.1.2?
2.b. Are you instaLl.ing in accordance with the 2018 IECC PRESCRIPTIVE PATH
using UA tradeoffs and a RESCheck Report? lf so, ptease submit your RESCheck
Report....
2.c. Are you instal.l,ing in accordance with an 2018 IECC PERFORMANCE PATH
using a HERSRater or other? lf so, ptease submit the performance software report
prepared by the rater or energy professionat.
3. What method of WHOLE-HOUSE VENTILATION are you proposing for this home
design?
3.a. Exhaust onty fan system(s)?
3.b. Combination system with ERV or HRV? lf so, where is the equipment being
instatted?
4. No graphic depiction of the BUILDING THERMAL ENVELOPE or outtine of the
insutated conditioned spaces was found on prints. Ptease submit a supptementaI
ptan page (cross section) or other cut sheets clearly il,tustrating the outtine of al,t
conditioned spaces and ctearty [abet, if any unconditioned spaces (such as
unconditioned attic space, unconditioned garage attic, unconditioned crawt space,
unconditioned room accessed off the garcge, unheated unconditioned garage
space??? etc)
5. As this property witt be served by LP propane fuettype, can you confirm IF any
propane fuet fired apptiances or equipment witl, be instatted in the craw[ space. lt
woutd be most he[pfut to receive something in writing from the buitder
indicating whether or not any equipmentwil,l, be ptaced in the crawl space, thank
you!
6. Architectural sheet 41.0 depicts a 20- minute attic stair in the garage Lid.
6.a. What is the proposed or intended use of the garage attic? Non-habitabte
garage storage on[y? Unfinished future residentiat tiving space or other?
6.b. No attic access opening is graphicatty depicted in the garcge on Studio M S3.0
and S.4 sheets? Want to ensure there's no field cutting / compromising of the
engineered truss layout. Request the structuraI engineer of record verify attic access
nnanind nn A "i ft ia namna+il-ri^ ..'i+1^ +tr^ ^+^'+r^aA a+vr.^+. '-^i ahaa+avyvr rrr 15 vr r n r .v ro uvr r rPqLrurs vvrLr r Lr rE or,clt I tPE;tl DLt (ltJLtlt clt ot tE;E;Lo.
6.c. lF garcge storage use is the intended function of the garage attic, wit[
ENGINEERED STORAGE TRUSSES be insta[Ied?
6.d. lF future habitabte Living space in intended function of the attic accessed above
the garage, then ptease remit an architecturaI ftoor ptan detail, for the future space and
confirm ENGINEERED TRUSSES witt be suppl,iecj to accommodate future residential
Living.
Ptease respond to questions 1-6 above by email, to Cotteen Wirth, Plans
Examiner, cwirlh@€arfie-[d--county.com. Where fut[ size sheets for supptementaI detaits
pertain, ptease submit to the Garfietd County Community Devetopment Dept front desk in
downtown Gtenwood Springs, (2) FULL SIZE paper copies reference BLRE-07-24-8794
SALINAS, c/o Cotteen Wirth Ptans Examiner.
Thanks for your care with this project -- I took forward to seeing the project move forward,
Cotleen Wirth
Buitding Plans Examiner
Garfleld County Community Development
108 8th Street, Suite 401
(970) 945-1377 ext 1610
cwirth @ga rf ietd -cou nty. co m