Loading...
HomeMy WebLinkAboutConditions of Permitco NDITIONS OF PERMIT BLRE-O 8.24-8845 PH ILIP ENSIG N 640 SO FT DETACHED UNHEATED GARAGE SHOP (NO PLUMBING, WATER SUPPLY OR HEATING PROPOSED) 683 Overlook Dr, GWS High Aspen Ranch Planned Community, Lot 23 1 ) ALL WORK SHALL COMply W|TH THE 2015 INTERNATTONAL RESIDENTIAL CODE t.R.c. / t.B.c. AND 2018 TNTERNATTONAL ENERGY CONSERVATION CODE (l.E.C.C.) 2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE ATTACHED "GARFIELD COUNry BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST. 3) ELECTRTCAL PERMtTTtNG AND TNSPECTIONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTI FICATE OF OCCU PANCY. 4) ALL EXTERTOR LIGHTING TO BE DOWNCAST AND SHIELDED. 5) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLYWITH WILDFIRE MITIGATION AND DEFENSIBLE SPACE REOUIREMENTS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE DISTRICT. PLEASE SEE GARFIELD COUNry COMMUNIry DEVELOPMENT WEBSITE FOR FURTHER INFORMATION. 6) OPEN HOLE SOTLS REPORT rS REOUTRED AT FOOTTNG TNSPECTION 2,000 PSF SOIL BEARING CAPACIry. 7) ALL HIGH STRENGTH BOLTING AND FIELD WELDING REOUIRES SPECIAL INSPECTOR. PROVIDE APPROVAL REPORT AT FRAMING INSPECTION. B) SOLAR PERMIT AND FUTURE INSPECTIONS THROUGH COLORADO STATE ELECTRICAL INSPECTION DEPARTMENT. IF SOLAR BATTERY EOUIPMENT IS INSTALLED, THEN SHALL PROVIDE SOLAR BATTER EOUIPMENT INSTALLATION MANUAL TO BUILDING INSPECTOR AT FUTURE INSPECTIONS. 9) ENERGY STORAGE SYSTEMS (ESS)SHALL BE INSTALLED IN ACCORDANCE WITH 2021 R328 (ATTACHED). 1O)THE BUILDING STRUCTURE HAS BEEN REVIEWED AS A PRIVATE USE DETACHED GARAGE SHOP ONLY ACCESSORY TO THE MAIN RESIDENCE. ANY FUTURE CHANGE IN BUILDING OCCUPANCY OR USE, WILL FIRST BE SUBJECT TO A NEW BUILDING PERMIT APPLICATION AND REVIEW FOR COMPLIANCE WITH ZONING REGULATIONS, LAND USE & BUILDING CODES IN EFFECT AT TIME OF FUTURE WORK. * ,E\ N N aNbrTTatV #fBUILDING PLANNING R326.4 Means of egress. The means of egress for habitable attics shall comply with the applicable provisions of Section R311. / sEcTloN R327 SWIMMING POOLS, SPAS AND HOT TUBS F.327.1 General. The design and construction of pools and spas shall comply with the International Swimming Pool qnd Spa Code. sEcfloN R328 ENERGY STORAGE SYSTEMS R328.1 General. Energ,, storage systems (ESS) shall comply with the provisions of this section. Exceptions: 1. ESS listed and lqbeled in accordance with UL 9540 and marked "For use in residential dwelling units" where installed in accordance with the manufacturer's instructions and NFPA 70. 2. ESS less than 1 kWh (3.6 megajoules). R328.2 Equipment listings. Energ,t storage systems (ESS) shall be listed ar,ld labeled in accordance with UL 9540. Exception: Where approved, repurposed unlisted baffery systems from electric vehicles are allowed to be installed outdoors or in detached sheds located not less than 5 feet (1524 rnm) from exterior walls, property lines and public ways. R328.3 lnstallation. ESS shall be installed in accordance with the manufacturer's instructions and thetr listing. R328.3.1 Spacing. Individual units shall be separated from each other by not less than 3 feet (914 mm) except where smaller separation distances are documented to be adequate based on large-scale fire testing complying with Section 1207 .1.5 of the International Fire Code. I{328.4 Locations. ZSS shall be installed only in the follow- ing locations: 1. Detached garages and detached accessory structues. 2. Attached garages separated from the Awelling unit living space in accordance with Section R302.6. 3. Outdoors or on the exterior side of exterior walls located not less than 3 feet (914 mm) from doors and windows directly entering the dwelling unit. 4. Enclosed utility closets, basements, storage or utility spaces within dwelling units with finished or noncombustible walls and ceilings. Walls and ceil- ings of unfinished wood-framed construction shall be provided with not less than s/r-inch (15.9 mm) Type X gypsum wallboard. ES,S shall not be installed in sleeping rooms, or closets or spaces opening directly into sleeping rooms. R328"5 Energy ratings. Individual ESS units shall have a maximum rating of 20 kWh. The aggregate rating of the ESS shall not exceed: 1. 40 kWh within utility closets, basements and storage or utility spaces. 2. 80 kwh in attached or detached garages and detached accessory structures. 3. 80 kwh on exterior walls. 4. 80 kwh outdoors on the ground. ESS installations exceeding the permitted individual or aggregate ratings shall be installed in accordance with Section 1207 of the International Fire Code. R328.6 Electrical installation. ESS shall be installed in accordance with NFPA 70. Inverters shall be listed and labeled in accordance with UL 1741 or provided as part of the UL 9540 listing. Systems connected to the utility grid shall use invefters lis ted for utility interaction. R328.7 Fire detection. Rooms and areas within dwelling units, basements and attached garages in which ES,S are installed shall be protected by smoke alarms in accordance with Section R314. A heat detector, listed and intercon- nected to the smoke alatms, shall be installed in locations within dwelling units and attached garages where smoke alarms cannot be installed based on their listing. R328.8 Protection from impact..E55 installed in a location subject to vehicle damage shall be protected by approved barriers. R328.9 Ventilation. Indoor installations of ES,S that produce hydrogen or other flammable gases during charging shall be provided with mechanical ventilstion in accordance with Section M1307.4. R328.10 Electric vehicle use. The temporary use of an owner or occupant's electric-powered vehicle to power a dwelling unitwhile parked in an attached or detached garage or outdoors shall comply with the vehicle manufacturer's instructions and NFPA 70. 11.328.11 Documentation and labeling. The following information shall be provided: 1. A copy of the manufacturer's installation, operation, maintenance and decommissioning instructions shall be provided to the owner or placed in a conspicuous location near the ESS equipment. 2. A label on the installed system containing the contact information for the qualified maintenance and service providers. sEciloN R329 STATIONARY ENGINE GENERATORS R329.1 General. Stationary engine generators shallbe listed and labeled in accordance with UL 2200 and shall comply with this section. The connection of stationary engine gener- ators to the premise wiring system shall be by means of a I i s t e d tr ansfer switch. N,t .l D 3-66 2021 INTERNATIONAL RESIDENTIAL CODE@