Loading...
HomeMy WebLinkAboutFoundation Design CalculationsFO UN DATION CALCU LATIONS 26'x25'Metal Building MVE #24-0852 PHIL ENSIGN Glenwood Springs, Golorado Metal Building Supplied By: GREAT WESTERN BUILDINGS 3033 S. Parker Rd 12 Floor Aurora, CO 80014 Foundation Design by: MOUNTAIN VIEW ENGINEERING, INC. 345 No, Moln, Sult6 A . Brlghom Clty, Utoh 84J02 phone (.+35) 734-9700 . rox (+ss) 734-9519 AUG 09 2024 3 pages of Calculations MOUNTAIN VIEW ENGINEERING, INC. Page: 3 Date: 08109124Job: MVE #24-0852 GREAT WESTERN BUILDINGS PHIL ENSIGN345 Nd Moln, Sulte A . Bdghom City, Utoh 84302 Fhons (4J5) 73{-9700 . Fox (+55) 7tr4-9519 Subject Wind Golumn Footinqs (Linesl&3/GridsB&C) PorL = 0.1 FH = 1.1 kips kips Length used for Bearing Calculation = 1.0 ft Check Soil Bearinq Allowable Pressure = 2000 psf B req'd = 0.22 fl Horizontal Force Use rebar hairpins to resist horizontal force. As req'd = 0.03 in2 L req'd = 0.7 ft - reinf. slab (6x6 W1.4xW1.4 min.) L req'd = 1.1 ft - unreinforced slab By:JPD Use 16 in. x 8 in. deep cont. footing reinforced with (2\ #4 bars continuous q= 75 PSf OK Use # 4 hairpin w/ 4 foot legs. MOUNTAIN VIEW ENGINEERING, INC. 545 No Moln, Suite A . Brighom City, Utoh 84J02 Phona (+J5) 754-9700 . Fox (43s) 734-9s19 Job: MVE #24-0852 GREAT WESTERN BUILDINGS Subject:PHIL ENSIGN Sidewall Footinqs (Line2/GridsA&D) Page: Date: By: 2 08109124 JPD Pont =.9kiP" F6 = 4.5 kips Uplift = 2.8 kips Check Soil Bearinq Allowable Pressure = 2000 psf B req'd = 3.08 ft Horizontal Force Use rebar hairpins to resist horizontal force. As req'd = 0.11 in2 L req'd = 2.8 ft - reinf. slab (6x6 W1.4xW1.4 min.) L req'd = 4.5 ft - unreinforced slab Uplift Design uPlift = Slab Thickness = DePth to toP of Ftg. = OS Conc. to CL Footing = Length of Wallfor Uplift = WallThickness = Design uplift = Slab Thickness = DePth to toP of Ftg. = (EW) OS Conc. to CL Footing = (SW) OS Conc. to CL Footing = (SW) Length of Wall for Uplift = (EW) Length of Wall for Uplift = Wall Thickness = Sidewall Gorner Footinqs (Linesl&3/GridsA&D) Pp*; = 8.9 kips F6 = 1.9 kips Uplift = 1.8 kips Gheck Soil Bearinq Allowable Pressure = 2000 psf B req'd = 2.11 fl Horizontal Force Horizontalforces will be resisted by the foundation walls adjacent to the column. Uplift Use 3.5 ft2 x 12 inch deep footing reinforced with 6\ #4 bars each way. q = 1551 psf OK Use # 4 hairpin w/ 6 foot legs Weight of Footing and Soil = 5.00 kips Weight of Concrete Slab = 1.99 kiPs Weight of Foundation Wall & Ftg. = 1 .13 kips Total = 8j2 kips Factor of Safety = 2.90 > 1.0 OK Use 2.5 ft2 x 12 inch deep footing reinforced with (4\ #4 bars each way. q = 1424 psf OK 2.8 kips 5 inches 36 inches 6.0 inches 5 feet 8 inches 1.8 kips 5 inches 36 inches 6.0 inches 4.0 inches 5 feet 5 feet 8 inches Weight of Footing and Soil = 216 kips Weight of Concrete Slab = 0.84 kiPs Weight of Foundation Wall & Ftg. = 2.60 kips Total= 5.60 kips Factor of Safety = 3.11 > 1.0 OK MOUNTAIN VIEW ENGINEERING, INC. 345 No. Mdln, Sult€ A . Brlghom Cliy, Utoh 84302 Phono (+J5) 734-9700 . Fox (455) 734-9519 Job: MVE #24-0852 GREAT WESTERN BUILDINGS Page: 1 Date: 08109124 Subject: PHIL ENSIGN BY: JPD DESIGN CRITERIA: Ground Snow Load Roof Snow Load Frame Live Load Roof Collateral Load Gode 2015 tBC Sos Seismic Design Category Site Class Other Loads: Soil Bearing Frost Depth 110 75 20 0.434 c D 2000 psf (per Geotech Report) 42 inches Wind Speed 115 mPh Exposure C lmportance Factor 1.0 psf psf psf psf5 Notes: Reactions per GREAT WESTERN BUILDINGS drawings. The foundation has been designed, and the site soils should be prepared for the foundation, in accordance with the recommendations in the geotechnical investigation report by: Daniel E. Hardin, P.E. of Hepworth - Pawlak Geotechnical, Inc. 5020 County Road 152, Glenwood Springs, Colorado Phone: (970) 945-7988 Job No. 114 5428 Concrete and Reinforcement: Concrete Strength