Test #
Retest
Of Test Date Proctor ID Method
Soil
Classification
Optimum
Moisture
(%)
Maximum
Dry Density
(pcf)
In Place
Moisture
(%)
In Place
Dry
Density
(pcf)
In Place
Wet
Density
(pcf)
Probe
Depth
(in)
Percent
Compaction
Min Comp.
(%)
Optimum
Moisture
Tolerance
(%)Remark
1 08/16/24 Curve No.
1
698A Cohesive 14.3 117.6 12.4 114.7 128.9 6 98 98 -2 / 2 A
2 08/16/24 Curve No.
1
698A Cohesive 14.3 117.6 12.7 115.5 130.2 6 98 98 -2 / 2 A
3 08/16/24 Curve No.
1
698A Cohesive 14.3 117.6 12.7 115.0 129.6 6 98 98 -2 / 2 A
4 08/16/24 Curve No.
1
698A Cohesive 14.3 117.6 12.3 114.7 128.8 6 98 98 -2 / 2 A
Test Information
Test #Test Location Elevation Reference
Gauge
Make / Model / SN / Calibrated Field Technician
1 Sub-Excavation and Backfill: Structure footings, southwest foundation corner.1.0 Below grade XPLORER / 3500 / 1995 / 04/16/2020 Downing, Thomas
2 Sub-Excavation and Backfill: Structure footings, 30' east of southwest foundation
corner.
0.0 Below grade XPLORER / 3500 / 1995 / 04/16/2020 Downing, Thomas
3 Sub-Excavation and Backfill: Structure footings, southeast foundation corner.1.0 Below grade XPLORER / 3500 / 1995 / 04/16/2020 Downing, Thomas
4 Sub-Excavation and Backfill: Structure footings, 20' north of southeast foundation
corner.
0.0 Below grade XPLORER / 3500 / 1995 / 04/16/2020 Downing, Thomas
Remarks
A: Test results comply with specifications.
Comments
Tests are "Direct Transmission" (Method A) unless probe depth is noted as
"Backscatter". Gauge calibration data on file with the testing agency.
4: As requested, a site visit was made to observe placement and
compaction of the soils being utilized to achieve proposed footing
elevation. The contractor is moisture conditioning the previously
excavated soils and is placing and compacting the soils in 8" to 10"
lifts. Compaction is being achieved with a walk-behind vibratory
sheeps foot compactor. Results of density testing performed today at
the locations indicated met project specifications. The contractor was
notified of our observations and density test results. Future site visits
will be scheduled with our office if needed.
This report presents opinions formed as a result of our observations of fill placement and the test results shown above. Test data are not the sole basis for
opinions whether the fill meets project specifications. The contractor is responsible to apply necessary compaction effort and moisture to comply with project
specifications. Our test results, observations and opinions do not constitute acceptance of the work.
Page 1 of 1
Compaction Testing
Test Method: ASTM D 6938
08/16/2024
Report Date: 09/03/2024
Report #: SNG-000001
Client:
Jonathan Duffy
Glenwood Springs, CO 81601
90 Mountain Shadows Drive
Project:
Duffy Residence
GS06684.000F-345
Garfield County, CO
County Road 331
234 Center Drive
Glenwood Springs, CO 81601
Phone: 970-945-2809
Glenwood Springs