HomeMy WebLinkAboutEngineer's OWTS Design PlanI29 CAINS LANE
CaneoNoRLE,CO 81623
970.309.5259
CARLA. oSTBERG@GMAIL.COM
sltlyt ra: (:()lisrf : r.'f I s<;
August 21,202+Project No. C1907
Dave and Suzan Andrus
DmandruslT@qmail.com
Subsurface lnvestigation and Onsite Wastewater Treatment System Design
4-Bedroom Residence
Lot 20, Rapids on the Colorado Subdivision
Garfield County, Colorado
Dave and Suzan,
CBO lnc. performed a subsurface investigation and completed an onsite wastewater treatment system
(OWTS) design for the subject residence. The 2.029-acre property is located outside of New Castle, in
an area where OWTSs are necessary.
Legal Description: Section:4 Township:6 Range: 91 Subdivision: RAPIDS ON THE COLORADO Lot:20
Parcel lD: 21 81 -O43-07-020
SITE CONDITIONS
The property is cunently undeveloped. A 4-bedroom residence is proposed
The residence will be served by a community water system. The water line will not come within 1O-feet
of the proposed septic tank or within 25-feet of the proposed soil treatment area (STA).
Garfield Creek bisects the property along the east side. Garfield Creek is located greater than 200-feet
to the east of the proposed residence. The Colorado River runs to the north of the property.
The proposed STA location has an approximate 1 to 2 percent slope to the southeast toward Garfield
Creek. The proposed area is vegetated with native grasses.
There should be no traffic or staging of material over the future STA site to avoid compaction of soils
priorto constuction of the STA.
SUBSURFACE
The subsurhce was investigated on July 17,2024 by digging two soil profile test pit excavations (fest Pits).
A visual and tactile soilanalysis was completed by Carla Ostberg atthe time of excavation.l
The materials encountered in Test Pit #1 consisted of light brown sandy loam to 4.0-feet, underlain by
moist, light brown sandy loam to a maximum depth explored of 8.O-feet. No bedrock or groundwater was
encountered.
' Carla Ostberg holds a Certificate of Attendance and Examination ftom the CPOWMsualand Tactile
Evaluation of Soils Training.
Page2
The materials encountered in Test Pit #2 were consistent with those encountered in Test Pit #1. Test Pit #2
was excavated to a maximum depth explored of 8.O-feet. No bedrock or groundwater was encountered.
A sample of the soil was taken from Test Pit #1 at 3-feet below grade. Soil structure grade was
moderate. The soilformed a balland a ribbon less than 1-inch in length before breaking. Soil structure
shape was blocky and consistence was firm. Soil texture was more gritty than smooth.
The soil is consistent with Soil Type 2, Sandy Loam, with moderate structure grade. A long-term
acceptance rate (LTAR) of 0.6 gallons per square foot will be used to design the STA.
View of property Test Pit #1
Page 3
sample Ribbon lessthan f -inch
Page 4
Looking towards Test Pit #2 Looking from Test Pit #2 towards Test Pit #1
Test Pit #2
DESIGN SPEGIFIGATIONS
Desiqn Calculations:
Average Design Flow = 75 GPD x 2 people/bedroom x 3 Bedrooms + 75 GPD 14tn Bedroom) = 525 GPD
LTAR = 0.6 GPD/SF
525 GPD / 0.6 GPD/SF = 875 SF x 1.0 (gravity, trenches) x 0.7 (chambersl = 612,5 SF I 12 SFlchamber =
'.i- E,l .r1..i^i- r' ^L^6L^-^rllrr. ut \{uIUNa vttcillltJiil-
The OWTS design is based on 4-bedrooms. An average daily wastewater flow of 525 GPD will be used.
For the purposes of this OWTS design, Benchmark Elevation at grade 5515.5' has been established as
lOO' /trinichor{ Flnnr nf fha rocidanna\ f\Elf'l lna charrl;{ ha na{ifiad af anrr rliaarananaiaa ar *raklam^ i.,:rLttevlt vvv vv rrvrrrlvv vl qllt srgvl9lJqllvlgo Vl l/lvWlgrllD Vvllll
grade elevations of proposed components during installation of the OWTS=
OWTS Gomoonent Minimum Elevation
Primary Tank lnlet lnvert Approximate horizontal distance 9' / min. 2o/o fall I
min.2.25" fall
Distribution Box Approximate horizontal distance 18'/ min. 1Yo rise /
min.2.25" rise
lnfiltrative Surface Approximate horizontal distance 28' to furthest
trench I min. 1%o fall to STA / min. 3.5" fall
Page 5
*Elevations are based upon standard OWTS installation practices. Component elevations may change during
installation due to site conditions. Minimum grade refers to piping between components.
The 4-inch SDR-35 sewer line exiting the residence must have a double'sweep clean out and a minimum
2o/o grade to the septic tank.
The system installation must include a minimum 12SO-gallon, two-compartment lnfiltrator@ poly septic
tank with an Orenco@ Biotube effluent filter on the outlet tee. Any state-approved concrete or poly septic
tank may be substituted. We have specified a 1500-gallon, two-compartment lnfiltrator@ poly septic tank
as they are available locally. Risers must bring the manhole lids to grade for access. lf more than one
riser is added to the septic tank, an extension handle must be instatled on the effluent filter.
Effluent will gravity flow to a distribution box, and then to four gravelless chamber trenches. The
distribution box must be accessible from grade and must have tlow equalizers, or similar product,
installed on each outlet pipe in the distribution box to assure equal flow to each trench.
Each trench will consist of 13 'Quick 4' Standard Plus lnfiltrator@ chambers for a total of 52 chambers
and 624 square feet of infiltrative area. There must be at least 4-feet of undisturbed soil between each
trench. lnspection ports must be installed at the beginning and end of each trench. Ports may be cut to
grade and placed in sprinkler boxes for access.
COMPONENT SPECIFICATIONS
The component manufacturers are typical of applications used by contractors and engineers in this area.
CBO lnc. must approve alternative components prior to installation of the OtftlTS. Requests must
be submitted, in writing, to our office for approval prior to installation. Component technical data
sheets are available upon request.
Construction must be according to the jurisdiction's adopted On€ite Wastewater Treatment System
Regulations, the OWTS Permit, and this design.
COMPONENT MANUFACTURER MODEL NO.COMMENTS
Septic Tank lnfiltrator@ tM-1530-2CP 1SOO-gallon, two-
:ompartment poly septic
lank
Effluent Filter Orenco@ 4" diameter full size filter
Tank Risers and Lids Orenco@ Double-walled PVg Rasers and
rids (24" diameter)
Distribution tsox Polylok Distribution box, risers, lid, flow
:qualizers (4)
chambers lnflltratofl@ 'Qulcl( 4', Plus Stanclard
Chamber
52 'Quick 4'chambers
Page 6
PERMIT APPLICATION INSTRUCTIONS
An OI|UTS Permit Application must be submitted to Garfield County Environmental Health Department.
!ttDS://www.qarfield-countv.com/environmental-health/filesqcco/sites/16/OWTS-Application-Complete-
PacKet-Dec.-2019.0df. lf the OWTS Permit Application will be submifted with a Building Permit -Application, it should be submitted directly to Garfield County Building Department.
Allquestions regarding permit submission can be directed to Garfield County Environmental Health
Departrnent, 970-945€61 4 x81 50,
INSTALLATION CONTRACTOR
CBO lnc. expects that the installer be experienced and qualified to perform the scope of work outlined in this
design. The installer must review this design thoroughly and coordinate with our office in advance of
installation. Any additional conditions in this design or county permit must be completed and documented
prior to final approval of the OWTS installation. Communication between the installer and this office is
expected throughout the installation.
INSTALLATION OBSERVATIONS
CBO lnc. must view the OWTS during construction. The OWTS observation should be performed before
backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing
siphons, and other plumbing, as applicable, must also be observed. CBO lnc. should be notified 48 hours
in advance to observe the installation.
ln an effort to improve the accuracy of the record drawing, we request that the installer provide a
sketch of the installation, including path of the sewer lines, water line installation (ii applicable),
septic tank location, STA location, and measurements from building corners or another fixed
gbiects on the property. This sketch is most easily provided on Sheet tnP.O of tne OWTS Design
Packet. Photographs of the installation and final cover are also requested to supplement our insiallation
documentation.
REVEGETATION REQUIREMENTS
An adequate layer of good quali$ topsoil capable of supporting revegetation shall be placed over the entire
disturbed area of the OWTS installation. A mixture of native grass seed that has good soil stabilizing
characteristics (but without taproots), provides a maximum transpiration rate, and competes well with
successional species. No trees or shrubs, or any vegetation requiring regular irrigation shall be placed over
the STA. Until vegetation is reestablished, erosion and sediment control measures shall be implemented
and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation
cover.
OPERATION INFORMATION AND MAINTENANCE
The proper$ owner shall be responsible for the operation and maintenance of each OWTS servicing theproperty. The property owner is responsible for maintiaining service contracts for manufactured units.
alternating STAs, and any other components needing maintenance.
Geo-fabrics or plastics should not be used over the STA. No heavy equipment, machinery, or materials
should be placed on the backfilled STA. Machines with tracks (not wheels) should be used during
construction of the STA for better weight distribution. Livestock should not graze on the STA. Plumbin[
frxtures should be checked to ensure that no additionalwater is being discharged to OWTS. For example, i
running toiletor leaky faucet can discharge hundreds of gallons of water a day and harm a STA.
PageT
lf an effluent filter or screen has been installed in the OWTS, we recommend this filter or screen be cleaned
annually, or as needed. lf the OWTS consists of a pressurized pump system, we recommend the laterals be
flushed annually, or as needed.
The homeowner should pump the septic tank every two yearc, or as needed gauged by measurement of
solids in the tank. Garbage disposal use should be minimized, and non-biodegradable materials should not
be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener
should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS.
Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste
only.
ADDITIONAL CONSTRUCTION NOTES
lf design includes a pump, weep holes must be installed to allow pump lines to drain to minimize risk of
freezing. The pump shall have an audible and visual alarm notification in the event of excessively high-
water conditions and shall be connected to a control breaker separate from the high-water alarm breaker
and from any other controlsystem circuits. The pump system shall have a switch so the pump can be
manually operated.
Excavation equipment must not drive in the excavation of the STA due to the potential to compact soil.
Extensions should be placed on all septic tank components to allow access to them from existing grade.
Backfill over the STA must be uniform and granular with no material greater than minus 3-inch.
LIMITS:
The design is based on information submitted. lf soil conditions encountered are different from conditions
described in report, CBO lnc. should be notified. All OWTS construction must be according to the county
regulations. Requirements not specified in this report must follow applicable county regulations. The
contractor should have documented and demonstrated knowledge of the requirements and regulations of
the county in which they are working. Licensing of Systems Contractors may be required by county
regulation.
Please call with questions.
Sincerely,
CBO lnc.
('t r' b- 0st6-ctg
Carla Ostberg, MPH, REHS
CBO lnc.
129 Calns Lane
Carbondala, Colorado I 1623
Phone 970,309.5259
carla.ostberg@gmsil.com
Y
SHUT OFF
-ffi
SfrBAcK
a
. GARFIELD
TP2
50'SETBACK
..'.._
\
+TP
SEPTIC. TANK
ro7 /8
Rd.pids on the Colorad,o
LOr t9
t?
43,o
Qepro
t
4
Andrus Residence
Lot 20, Raplds on the Colorado
6arfi eld County, Colorado
ProjectNumber: C1907
Dale: 08121i2024
Dasigned by: CBO
Drawn by: DD
w1.0
Sheet 1 0F 4
N
ffi BRANNON
PRAPERTIES
4039 335
COUNTY
RDSCALE: 1 = 50'E0'
LOT 2I
Rapid; on tl"e Colorod,o
RESIDENCE
PROPERTY
THE LOCATION OF PRoPoSED IMPROVEME\ITS SHOyJN ARE
NOT THE RESULT OF A PROPERW SURVEY, THE LOCATIONS
ARE APPROXIMATE. IT IS THE HOMEOWNERS'DUTY TO
ENSURE ALL CONSTRUCTION AND IMPROVEMENT LOCATIONS
ARE ACCURAIE. PROPFRTY LINES AND SETBACK DISTANCES
SHOULD BE CONFIRI.IED PRIORTO EXCAVANON, SCALED
FOR PRINNNG ON
'
1" X 1/ PAPER.DENNIS MICHAEL &
.SUS/if KATHERINE KRUMPFER,
ESUINE OPEN SPACE
RAPIDS ON THE COLORADO
PUD
3839 335 COUNTY RD
DRAWINGS MUST BE USED IN
CONJUNCTION WITH DESIGN
LETTER DATED 08121 12024
A SITE PLAN
CBO lnc.
129 Calns Lan€
Carbondale, ColoEdo 81 623
Phone 970.309,5259
oarla.oBtberg@gmail.com
.1.
.F
.p
.tL
DNvJ,y4y GARAGE
FF 5515.0
.F
Andrus Residence
Lot 20, Rapids on the Colorado
Garfi eld County, colorado
Project Numbec C1907
Date: 0812112024
Designed by: CBO
Drawn by: DD Sheei 2 0F 4
w2.0
.fr .F.
.r.
&8f '*2 .F
.P .lL N Ini,galion
EasemBnt
.p
.t ffisq
.?.P
.P
SCALE: 1" = 2010"
.F
4.BEDROOM .?
( RESIDENCE
.f'BM '100'= FF 5515.5
.,-?1,:j,
Lorudo €.F.F .f.
rP2.F.f.r .F..?
cg
\\
4'DIA SDR.35 INSPECTION PORT AT
BEGINNING AND ENO OF EACH TRENCH
4" DIA SDR-35 SEWER PIPE CLEANOUT
MIN 2% FALL TO TANK
.?
\ \-\TP1 .F .F
MIN. 12so-GALLON,
+
SEPTIC TANK WITH EFFLUENT SCREENv \v/\
4" DIA SDR.35 SEWER LINE TO STA
.*
.?
\
\
'QUICK-4' CHAMBER TRENCHES.
4 TRENCHES WTH 13 CHAMBERS PER TRENCH
FOR A TOTAL OF 52 CHAMBERS AND 624 SF,
(MtN. 1olo FALL TO STA)\\\$F\
DISTRIBUTION BOX
WITH ACCESS AT GRADE\\ \
.p .?
\
.P
.7..p
4" DIA 8DR.35 DISTRIBUTION LINE TO EACH TRENGH
(MtN. 1% SLoPE rO TRENCH)
BUILDING SETBACK .>
.p
*.?
PROPERTY .P
CALL 811 FOR UTILITY
LOCATES 2z .(,0'.F.N
CBO lnc,
129 Calns Lang
CaDondale, Colorado 81423
Phon€ 970.309.5259
carlaoslberg@gmall.corn
GRAVELLESS'OUICK4' PLUS STANOARD
NOTE: TRENCH INSTALLATION SHOULD BE AS
sHArtow As PoggtBLE.
CFIAITBER (4' x 3')
BOX WTH ACCESS AT GRADE
ENO PLATE DIA SDR-35 EFFLUENT PIPE FROM SEPT]C
TANK DIA SDR-35
INSPECTION
PORT
4'
sl)tL
2',
4' DIA SDR.35 DISTRIBUTION LINE TO EACH
TRENCH
(MtN. 1% SLoPE TO TRENCH)EXCAVATION
4',GRAVELLESS 'QUIgK.C
CHAMBER (4'xs')
PLACED IN
A CIIAMBER TRENCH SEC]ION\rr__--___15,8
TOP PORT OF CHAMBER END
PLATES
DIA SDR.35 INSPEfiION PORTAT BEGINNING
AND END OF EACH TRENCH
A\ CHAMBER TRENCH PLAN\rt___--._T7r6.cE
SMALT'r'AL\€ COVER
3OX OR IRRIGATION
VALVE BOX AT GRAOE
FINISHED GRADE
CAP OR THREAOED
CLEANOWASSEMBLY
4'DIA SDR.35 SEWER L{NE
COMPACT (MtN
MIN,
2% SLOPE TO TANK,
1% TO STA)BASE
'O
SUPPORT
BOX
USE HOLE SAW TO
CUT THRU TOP OF
4" F\rC PIPE CUt TO
FIT
SCREENED
OR SAND FOR
EEDDING
3" MtN.
ENO
ADISIRIBUTION EOXtgr--._mffi
13 CHAMBERS PERTRENCH
E
r .l-.. '
Andrus Residence
Lot 20, Raplds on the Colorado
Garfl eld County, Colorado
ProjectNumb€r: C1907
fat",
oatztnoz+
lDesigneo oy: CBo
lDrawn
bv: DD
w3.0
Sheet 3 0F 4
CBO lnc.
129 Cain6 Lan€
Carbondale, Colorado 81 623
Phone 970,309.5259
carla.ostberg@gmall,com
DESIGN
STA TO WATER COURSE 50'17o',
STA TO WELL 100'
STA TO HOUSE m'25'
SEPNC TANK TO WATER COURSE 50'250'
SEPTIC TANK TO WELL 50 NIA
HOUSE TO SEPTIC TANK 9'
OWTS COMPONENTS AND
PHYSICAL FEATURES
MINIMUM REQUIRED
SETBACK
APPROXIMATE PROPOSED
SETBACK
PROPOSED 4.BEDROOM RESIDENCE
75 GPD x 2 PERSONS/BEDROOM x 3 BEDROOMS + 75 cPD (4th BEDROOM)
WASTEWATER FLOW = 525 GPD
USE MIN, 1250 GALLON, TWO-COMPARTMENT SEPTIC TANK
SOIL TREATMENT AREA (STA):
LONG TERM ACCEPTANCE RATE (LTAR) = 0.6 GAU SF
CALCULATED STA = Q/LTAR = 525 / 0.6 = 875 SF
875 SF X 1,0 (GRAVITY, TRENGHES) X 0.7 (CHAMBERS) = 613 SF
613 SF / 12 SF/CHAMBER = MlN. 51 CHAMBERS
4 TRENCHES, EACH WITH 13'QUICK 4' INFILTRATOR CHAMBERS
/ASEIBAO( CHARTLtF--lrtdll
BOXAND COVER BROUGIfTIO GRADE
CONCRETE
SOIL PROFILE TEST PIT NO. 1 SOIL PROFILE TEST PIT NO. 2 EN-o"fift-
-0
-t
:,
-3
-4
5
-b
-,
-8
-'
-10
LIGHT BROWN SANDY LOAM LIGHT BROWN SANDY LOAM
BAFFLE OR
ANGLED PIPE
TO BE USED
AT INLET
FuuE
EFcUo
ADISIRIBUTION BOX DETAIL\9r-ar'1rEE
MOIST, LIGHT BROWN SANDY LOAM MOIST, LIGHT BROWN SANDY LOAM SLIP-ON PVC
DO NOT GLUE
INSULATEO
TMCERWIRE FINISHED GRADE
4'DIA
NO GROUNDWATER OR BEDROCK ENCOUNTERED
DURING EXCAVATION
SEWER LINE
/iSOlLS LOGLrt____-__rrlfw
!g9E!9.
f';ll sandy
loam
OUTLETS
oooo
Andrus Residence
Lot 20, Raplds on the Colorado
Garfeld County, Colorado
ProjectNumber: C1907
Datet 0812112024
Designed by: C8O
Drawn by: DD
w4.0
Sheet 4 0F 4
Docusign Envelope lD: 30D9F4E$02A2-47S&&1AD€E5'IoCOAEEA8
Chd Utuc
41.51'
35.11'
N38"Dr3{
N31.3615{T
Chod BadnoCdrolAmlo
19"02'&l
20'13r3,
Rodiug
50-00
100.00
A( Lenqifi
17.8t'
Cu*e No.
cl
D^r€ I RfrSd dscRrFuJob No.r 18.013
Ootet Aprit 22, 2A24
.dw9 filer 18.013.120
Cllentr Dovid ond Su:on
Andrug
Drcwn By: 5. Phelps
A26-1/2 Grond Avenue
Post Office Aax 2782
Glenwood Springs, CO, 81602-27A2
SurwCo, Inc.
Professlonal Land SurveyinGlseldgee'ffi-
Sheet
1of 1
Found rebar and 2u
slumlnum cap, PLS
No. 13501.
Set nail "polnt on llne"
Irrlgatlon valve(s) .
tot \lne)
Adjolner wood rall fence
Improvement Location Certilicate
Lot20, The Rapids on the Colorado Subdtu'ision
As Amended
Situated in the SW1/4 Section 4
Township 6 South" Range 91 West of the 6th P.M.
County of Garfield, State of Colorado
l@.
{Cefiifi6iin putssnt ro C.R.S. 3&51 . I 08)
I her€by edit lhd ifijs lmpDmeir bcolion Cen{icoie wos pepored by
Sun4o, lnc., {u Sheilo \nn Smilh, ihot i is iol 0 land suryey pld d improvored
suMy dd ond liot il b nol to b rdied lpon hr lhe doblBhmeni oi f€d€,
boibing, or dher ldu€ inpbwnsl lines. Tlis eriiffde ii rclid only lor
ue by Dovid ond Surcn Andm oni ducrib* ihe poreh oppmom€ on Apd 22, 2C2l.
I fudlFr qdifi ItFl ho improvmenh s lhe obovo d$crib€d porcd on lhb
Me, Apd22,2A24 , ercdr'. unliiy cnrslihs, ore edicly fiihln ihe bovndories
ol tfie poel, exep os s}*n, tfid lhe6 oe m etrrddm.ils upon lhe deiH
premlsr, repr os ldided, ond {Ft'h*e is no oppoeni evtlene or sign ol ony
ft*ment crc$iq of bldening ony p,l ol soid pel, wept os rcted.
By: Somuel D. Phel6
Coloodo Liored PoJesaond
Lmd Suneyor No. 276 I 3
Fo od on bohoffof SuruCo, Inc
A Colorodo spordion
Doo ol @dilidid; AFil 22, 2024
I ) This lnpbwrent lMtion Cediffc& doa d epesnt o {& sffh by fijs
lond suneyo o lond suruyirg conpoff All inlomolis pedoinins lo Mne6hip,
ffiMh ond ollE 6n.umbrence ol reord b hken ftom o fith insunnce
cdmil@i1 isued bl tlnd Tide Guoene Cmpony, ille insonce commlment or&r
No. G86302 I I 39, e{lociivc dolE tlord 08, 2024 d 5100 P.lvl.
2) Thh propedy b $bird ro dntrl dgil csedtuns od U5 pdril 4;ht os nded
in lh6 obove ebr*cd Hle insuFr6 cohmilmd.
3l Thh propd h subled to Foiedi6 covenoils md Brlidions os noled in lhc obow
t€nced fi* hsu'dfte comditmcd.
4)Thb lmprwment looiion Gdihdr is bosed upoi ile mnlmedolion lound in ihe f eld
os indiohd hereon ond tlp recdd .lot lor fie 3ubied popeiy (R@plion No. 639203).
5l Dote ol ffeld suwep April 22, 2024
6)AI I.6rd:r.'tus shorn remn ce in uS surq leer.
4 Csin &l ie opp@ on llE pld dl Tfu Xopids q llB Cdorodo os Amended tlrd
ol{ea fr srbi* prop*ty ond by hh €le6n6 o€ iol6d lt@n,
Ndker lPu&onlb C.R.S. 13.801051:
Aording b Cobftdo h yor muil commen@ ony hd ocJid bd*d upon oiy d{ed ln lhis
lnpomoil Lodbn Cfilical. wilhln +e yeo6 dlH )bu liili disw sd defud.
h no Nrl mq lnv 0.1ion blsd upon orry de{ect in ilris lmpoemni bcofim Cerlficcp be
commnc6d mm,lEn bn Fo6 toft 116 dds of dilicalion shom hmon.
Edge of
Rapids View Lane
Found rebar and 2''
aluminum cap, PLs
20 ond I 0 Uilily, dminos
{ne. No. 639203)
1I
No.13501.
Dralnage
ditch
Electrlc trans.
Tele, rl*r
Found No. 5
Irrlgatlgn
Fosnd rebar and,Z' //
alunlnum mp, PLs
No, 13501.
o-
AdJolner chain link
!@.
Ldm
Tfc RotiJs oi iho Col@do
rerding to tlc omvded plo
thereol os frled br rcrd
Od. 24, 2003 undd ReQplio0 No. d39203
County of Godisld
lloF o, coldodo
50 60
Nol sbmd
NewCosil6, CO.81647
{rci wirhin munjchol limilt
GRAPHIC SCALE
( IN FEET )
1 inch = 60 ft.
N89?8?6't
310.09
Oulll@
J
Lot 20
The Raplds on the Colorrdo
Subdivlelon as Amelded
(Rec. No.639203)
(Vacetrt)
(2.03 acres as pbtted)
23,
-0 0.
SdndO"
6126124,8:14AM
Garfield County, CO
qPublic.net - Garfield County, CO - Poperty Record Card: R170372
Summary
Acount
Parc.l
Property
Addrcss
Legal
D6cdpthn
Ag,e3
lend SqFt
TaxArca
MilllGty
Subdlvlslon
RL70372
218104{tO7020
,NEWCASTLE,CO 81647
Sectlon: 4Toivnship. 6 Range: 91 Subdlvlsion: RAPIDS ON THE
COLOMDOLoh20
zo29
0
!7
5L1150
RAPIDSONTHECOLORADO
View Map
Map
Owner
ANDRUS.DAVIDM&SUZAN M
.133 R|VERVtEW DRTVE #1605
NEW CASILE CO 81647
Land
Unlt Tlpe 1 AC TO t/T 5 AC - O52O {VACANT LAt\tD}
SquaraFoat 0
Actual Values
Taxleer
ActualValug
Assessed Values
.Taf Yaal
Aesesed\rrblue
Tax History
TaxYeal
Ta(esBllled
m24
t1.04.200.00
20iu
rro,asQoo
m23
$1442{n00
m:23
'4DP30SO
ry1
$2,056.36
m22
t47,U2Am
min
$1S,640.m
x)22
20,21
945,640.00
XW
ris,zao.m
2o'21
mm
t21,710.00
2020
i630.OO
mm
$353.e6
Click here to vieldhqlaritlormgllpltblltliqparceljn tbe_tGat]ftqk! tqountv Treasurer's website.
$7szw $825.12
1t2
6/126124,8:14AM
Transfers
qPublio.net - Garfield County, CO - Property Record Card: R170372
ReceptlonNumber
??614e,
e589?3
594733
Book- Pasa
t316-983-987
1032-0948
10s24945
1032-0951.
09960665
o€3+o-233
M79-M29
0!165-0207
0466-0204
o466-N29
foniacl Us
Sale Date
.
5lt6l20?4
ilLOnOn
7U281200r
gtut997
91311e97
uu79@
u1/te0o
uuTry
uutry
uutgw
u7/L90o
uuTw
DerdlVpe
SPECIALWARRANWDEED
EASEMENT
SPECIALWARRANryDEED
ST.IBDIMSION IMPRo\/EMENTS
SPECIALWARRANTY DEED
Deeds
Deeds
Deeds
Deeds
@l
Deeds
Deeds
Sale Prlce
$215,mO
$o
$o
$o
$o
$o
$o
$o
$o
$o
$o
$o
Property Related Public Documents
Click here toview ProoerW Related Publlc Documents
No data avallable ior the follodng module$ Buildlngs, Photos, Sketches.
The Garfield County Assessor's O{fce makes eve.'y effort to produce the most accurate
infcrmati<x possiirie. No wai-ranries, expressed or implieci are provideri fr:r the rjaia herein, its
uce or interpretfitir:n. Daia is subleri to constant change and its accuracy and co$tlcieness
cannoi be guaranteerj.
i User Privacy Policy i 9Qg$PliyasvXslisg
Lasr D ata U dqiAdt 6 / ?9 /2O?4 El9,s 6 AM
lleveleiped by
{.)Fgl'g'g'd*
a2
Item #
IH.{53G2GP
{53O Gallon TIro Gompartment
lnfiltrator@ Poly Tank
TANKTOP
HALF
co'lTrNuot s
ELASTOITiETRIC
175.6"TANK
INIERIOR SEAM CLIP
(86)TOP VIEW
AUqnE|fr
DOTTEL({O TAIIKBOTTOITI
HALF
24" ACGESrSFORT
wllfr LocKrNG uD (s)
Ta{cladttdrsK,
@ up+rercnrsEAM sEcnoN DETATL
OIMETTEE
2ISTOTALVOL lETOTALVOL
srDE vrEw
SEAII CI.JP
r Compliont with CSA ond IAPMO Stondordsr PVC risers ovoilobler Secondory sofety screen ovoiloble with
PVC riserr Moximum buriol depth is 48"r Minumum buriol depth is 6"r Tonk is not roted for vehiculor troffic
loodingr Exterior of monhole cover includes the
following worning: "DANGER Do NoT
S.|TER: POISON GASES"
UFnNoSTRAF
FYFTCAT)
END VIEW
ffir,rr**r,*['
rf,n^nmarc.
16' Long x 7' Wde
43" below inlet
fi o
<-
o
o-
o
<F
o
o-)
o
-o
o-
{t
FtsERGLASS
SUPPORT
I ,,i'
SLOT
Digging Specs lnvert Dimensions Net
Weight
Net lVorkinq Copocity
lnlet
+7"
Outlet
44"
Length
175.6"
width
61.7"
Height
54.5"1006 gol 503 9ol 1509 sol5O1 lbs.
Wd.r&Wrffir
o SYBloms
r Prcduds
I[G. o ssvloo
Fr9) 3St{76{ ztrEcoru'fl7
P.O.Bo(gs
Fu: (f19) 3ff'grn RH€E@8'.a-I
UTobrlb: wrvw.vd$pacaot un
Endl:ffim,
Residential Biotube' Eflluent Filters
Applications
Our patented* 4-in. (100-mm) Biotubc Effluent Filters, Biotube Jr., Biotube
Insert Filters, and Biotube Base Inlet Filters are ideal for residential septic
tanks and have a liGrime warranty. Thcy prcvent large solids from leaving
the mnh dramatically improving wastewafer quality and e.xtending the life
of residential drainfi elds.
4-in. (100-mm) Bionbe Effiuent Filter
4-in. (1 00-rnm) Biowbe Jr.
(4-in. Bionbe cartridge aaail-
ahh separately as Insert Fiher)
*,,
Yj,
ti
;:.
t.
8-in. (200-mrn)
Base Inlet Fiber
4-in. (lA}-mm)
Insert Fiher
.,*
:t,
:
Orenco's sulterior ffiaentfbets resist clogging bener than all other brands. Our stan-
tkni full-sized 4-in. (100-nm) Biotabe Elflaent Fiber prouidzs maximum lang+erm
protection in a comphte package, with hoasing Our 4-in. (100-mm) Bionbe Jr., at
half the size of our standard model, has nore fltering capacity than the full-sizedfilters
sold by other manufacturers. For tanhs ttith existing oatlet tees, the Bioabe Insert Fiber
is idcal. Andfor hw-profh tanhs, there's the Base Inltt Filten
* Covered by patent numbcrs 5,492,635 and4439,323
To 0rder
Call your nearest Orenco Systems@, Inc. distributor. For nearest distribu-
tor, call Orenco at 800-348-9843 or go ro www.orenco.com and click on
"Distributor Locator. "
APS-Fr-l
Rev.3./t @ 11110
orenco Systomso, lnc.
S-anda-rd feature--s & Benelits
. Has 5-10 times
more flow area
than other brands,
so lasts many
times longer
between clean-
ings, increasing
homeowner
satisfaction
. lnstalls in min-
utes inside new
or existing tanks;
eKendible tee
handle for easy
removal
. Easyto clean by
simply hosing off
whenever the tank
needs pumping
. Removes about
two-thirds of sus-
pended solids, on
average, extending
drainfield life
. Corrosion-proof
construction, to
ensure long life
. Ufetime warranty
0ptional
Features &
Benefits
. Alarm available,to
signal the need for
cleaning
- fl-- , ---r -l,a:r FIlu, rillrill[ailtril
discharge orifices
available to limit
flow rate leaving
tank, mitigat-
ing surges and
increasing
retention time
. Custom and
commercial sizes
available
Biotube
Filtering
Process
Effluent from the
relatively clear zone
ofthe septic tank,
between the scun-l
and sludge layers,
horizontally enters
the Biotube Effluent
Filter. Effiuentthen
entersthe annular
space between the
housing and the
Biotubes, utilizing
the Biotubes'entire
surface for filtering.
Particles larger than
the Biotube s mesh
are prevented from
leaving the tank.
,'---\. '\*r'ft-z*.r
€
OrencoSystem*'
ir:r 'r'.rr:n r rl::,d
Cl:tngiry tfu lT/*v thr
V4t rtd t,l o t ; \Yi t.c t t u,at t t' r"'
www.otcnco.eom
Nomenclatures
4-in. Biotube Fifter {standard)
FT 04 !$
Filter diameter (inches)
W = fitsType 3034 outet pipe
S = fits Schedule 40 outlet pipe
0ptions:
Blank = no optionsM = flow modulatlon plate installedA = float bracket attached
Carfldge height 28" and 36" are standard
Housing height 36" and 44" are standard
0ptions:A = float bracket
FS = 2" outletorifice
FSo = 2"oufletorifi$andoverflou/plate"
Base inlet model
Cartridge height: 14" standard
Housing height 22" stafldard
Fllt€r diameter (inches)
Biotube effuent filter series
Blank = 1/8" fillrationP = l/16" llltration
08 =8"
Blank = 1/8" fikationP = 1/16" fllfation
Biotube effluent filter series
f-in. Biotube Fiher base intet modell
FT w22-14 B
"Also a\railable wi$ ff)upling and sleeve as a "kit": FI-OVEHFLOWKII
tl-in. Biotub9 Jr. (includes carridge and housing)
FTJ 04 18
0plions:
Elank = nooptionsM = flor{ modulat0n plate lnstalledA = floatbraclctattacted
C€rf idge heighl (indres)
Filter diameter (inches)
W = iitsType 3034 outletteeS = fitsSchedule40outlettee
Blank = 1/8" filtntimP = 1/16"fiflratbn
Junior se{k}s
Biolube elfluent filter series
4-in. Biotube Fiker lnsert (cartridse onty)
Ft i tro+ ls -[
t:
D
For G'ustomiz€d @tions (e.9., NC
indicates l.loft Carolina r€gions)
= fibType3034oufletbe
= iSSchedule40outlettee
Cartridge height (inches)
Filter diameter (inches)
Blank = 1/S" filtrationP = 1/16'filtalion
lnsert
Biotube effluent filter series
Distributed By:
&in. Biotube
Effluent Filter
Extendible PVC handle
Stainless steel set screws
Top seal plate
Air
Biotube@ filter cartridge
Solid base
Filter housing
4-in. Biotube Jr.
Tank wall
Riser
wall
V
1000
Double Walled PVG Riser & Lid Option$
Poly Lld
(Sffic load bsbd b s(Xn bs). Skid leeistane surfre. Available in gmen. Higheot level of W Protecfion idudod. lndudes a fuam gasket br alrfght aM
water0ght applicalims. Fdrffi sqlrete drlvc snrrg b dbmwqe
unauftodzed onty. lnsulaton pande acfileve R-l0lmdafron mtng
T ol lnsuhtion
Sbndard
Orcnco o DunaFibern Access Lids (FLD)
Not racommended br vehicularffic
A" aN 30" Diamebns. Solid, rcein-lnfrsod fibsglass @nsm&frm. Al,fiXl-lb brcaklng sfi€ngh. Standard gt€n on brcrvn @lorg. Avallable wllh orwithout urcffiane lld gasket. Available wilh ca6on fl,haton. 4 stalnlae sbd f,aftead socket cap sct€l,us & ho(
keyrvramfr. lnsulated llds avallable -T q 4'
Double Walled PVC Riser
. Available in?4r and 30" Diarnsbr. Cutb lengtt. Sold in +Ft iruernenb. Must bo cut betreen rlbe
ffi
ilff.*, fnetrsrrGr ffisrz
:Fffi I-?T grelsss-szzr Hsavtr4@$al
1Inc..bo,il
POTYLOK DISTRIBUTION BOX,
RlsERS, AllD LID
uD€ox6&uD€ox8
'- - --*22'45tt-+DAOXSEALrffi.trfls@@16"SIT'ECUTOt'T
TOACCEPI
FOLYLo|(SEAL
NO.:t001 TEARfl'TFOR
4"SDR€5OR
scflD40
ArorToscAl"E
uDsx6'R|8ER
ROTO#Lffi4'
I
6"
I
uD€ox t2'RlsER NOTTOSCAIE
POLYLOCK E(UAIJZER
'!/-NOTCH'WEIR
1 8E.F I.EYEIIE @
NESFROVDEffiTOI
HTFMAII''P3ED
1 +
20'GO\IER FOR RISER & D€OX ilor70s/uE
GASKETED SEAL ON
LID & RI$ER
Wtrr&
Warffiebr
r Sysbme
r Pmducts
ctiglrgS{?o+ axEooru'3l7
P.O.Bo(S5
F fl19) Wrn BHla\H4ffi8121-1
Webdb: wrvrv.vdlqprccaot on
Enulft fonUe@raqmrcd.mmPRECASI;Inc. eseryle
e F t
,1 t tL
p D
Ouick4 Plus
All-in-One Periscope
Ouick4 Plus Standard Chamber Ouick4 Plus
All-in-One 12 Endcap
Center Structural Columns
The Ouick4 Plus Standard Chamber offers maximum strength through its two center structural columns. This
chamber can be installed in a 36-inch-wide trench. Like the original line of Ouick4 chambers, it offers advanced
contounng capability with its Contour Swivel ConnectionTM which permits 1O-degree turns, right and left. lt is also
available in four-foot lengths to provide optimal installation flexibility. The Ouick4 Plus All-in-One 12 Endcap, and
the Ouick4 Periscope are available with this chamber, providing increased flexibility in system configurations,
Quick4 Plus Standard Chamber
. Two center structural columns offer increased stabilitv and
superior strength
. Advanced contouring connections
. Latching mechanism allows for quick installation
o Four-foot chamber lengths are easy to handle and install
. Supports wheel loads cf I6,000 lbs/axle with 12" of cover
Quick4 Plus All-in-One 12 Endcap
. May be used at the end of chamber row for an inlel/
outlet or can be installed mid-trench
r Mid-trench connection feature allows construction of
chamber rows with center feed, as an alternative to
inletting at the ends of chamber rows
r Center-feed connection allows for easy installation of
serial distribution systems
. Pipe connection options include sides, ends or top
Quick4 Plus All-in-One Periscope
o Allows for raised invert installations
r I80" directional irrletting
o Twelve inch raised invert great {or serial applications
-4ut#H P/'IJS
A I l I fII
Ouiak4 Plus Standard Charnber Side and End Views
(EFFECTIVE LENGTH)
&uiek4 Flus Al!-in-One 12 Eneap Fnont, Side and End Views
1'l
13"
8" INVERT 8'INVERT 5.3" INVERTt
Quick4 Flus All-in-Sne Ferlscope
OUICK4 PTUS
ALL]N.oNE
(3S'SWvEr )
33"
OUICK4 PLUS
ALL.IN-ONE 12
ENDCAP
12.7"LagEat *1,.L [,"-]
Quick4 Plus Standard Chamber Specifications
Size(WxLxH)34'x 53" x 12" (86 cm x 135 cm x 31 cm)lnvert Height .....,,...,...... 0.6n, 5,3', 8.0', 1 2.7'
(1.5 cm, 8.4 cm, 18.5 cm, 22.6 cm)Effective Length 48' (1 22 cm)
TNFILTFATOR SYSTEMS, INC. STANDARD LIMITED WARRANTY
ia) The structural integrity of each chamber, end plate, wedge and other accessory manufaclured by lnfillrator { Units"), when inslalled and
operated in a leachfield of an onsite septic system in accordance with lnliltrator's instructions, is warranted to the original purchaser ("Holdei )
against delective materials and worl(manship for one year from the date that the septic permit is issued for the septic system conlaining the Units;
provided, however, that if a septic permit is not required by applicable lav/, ihe warranly period will begin upon the date that installation o{ the
septic syslem comrnences. To exercise ils watranty rights, Holder must notify lnliltrator in wriling al its Corporate Headquarlers in Old Saybrook.
Cannecticut within fifteen {15) days of the alleged defect. lnfiltrator will supply replacement Units for Units delermined by lnfiltralor to be covered
by this Limiled Warranty. lnlillralor's liability speci{ically excludes lhe cost of removal and/or installation of the Units,
(b)TIlE LIMITED WARRANTY AND REIIIEDIES IN SUBPARAGRAPH (a) ARE EXCLUSIVE. THEFE ARE NO OTHER \'VARRANTIES WITH RESPECT
IO THE UNIIS, INCLUDING NO II\4PLIED WABRANTIES OF MFRCHANTABILITY OF FITNESS FOR A PARTICULAB PUFPOSE
(c) This Limited Warrtrly shall be vojd if any parl of the chamber system is manufaclured by anyone other than lnfiltralor. The Limited Warranty
does not exiend to incidental, consequential, special or indirect damages. lnfilkator shall not be liable for penalties or liquiciated damages,
includlng loss of production and profits, labor and materials, overhead cosls. or otlrer losses cr expenses incurred by the Holder or any third parly.
Specilically excluded from Limited Warranty coverage are damage to the Units due to ordinary wear and tear, alteration, accident, misuse. abuse
or neglect ot the UniLs; the Units belnq subjected to vehiclo lraffic or olher conditions which are nol permitled by the inslallation instruclionsl failure
lo majntain lhe minimum ground covers set to(h in the installation rnslructions; the placement of improper materlals into the system containing
the tjnits: failure of the Units or the seplic system due to improper siling or improper sizing, excessive water usage, improper grease disposal,
or improper operatjon; or any other evenl not caused by lnfiltrator. This Limited Warranly shall be void if lhe Holder lail6 to comply wilh all of lhe
tcrms set forth in thjs Limited Watranty. Furlher, in no cvcnt shall loiiltrator be rcsponsible for any loss or damage to the Holder, thc Units, or any
third party resulting from installation or shipment, or from any product liability claims ot Holder or any lhird pa(y. For this Limited Watranty 1o
apply, the Units must be installed in accordance with all site conditions required by state and local cooes; all other applicable lawsi and ltrfiltrator's
installation instructions.
(d) No representative of lnfiltrator lras the authorily to change or extend this Limited Watranty. l{o waruanty applies io any party other ihan the
original Holder.
The abo!€ represenl$ the Standard Limiled Warranty oflered by lnfiltrator. A limited number of stales and coLrnlies have different warranty
requiremenls. Any purchaser of Units should contact lnfiltrator's Corporate Headquarters in Old Saybrook, Connecticut, prior to such purchase,
to obtain a copy ot the applicable warranty, and should carefully read that warranty prior to the purchase of Units.
IN FILTRATOR'
systems inc.
6 Business Park Road ' P.O. Box 768
Old Saybrook, CT 06475
860.577.7000 . FM 860.577.7001
8AO.221.4436
www,i nf iltratorsystems.com
U.S. Patents: 4,759,661; 5,01 7,041; 5,156,488; 5,336,01 7i 5,401,1 16; 5,401,459: 5,51 1,903; 5,716,1 63: 5'588'778; 5,839'844
Canadian Patenls: 1,329,959; 2,004,564 Olher patenls pending.
is a registered trademark in Mexico. Contour Swivel Conncction is a trademark ol lnlilllator Syslems lnc. (O 2009 lnliltralor Syslems lnc. Prinled in [].S.4.PLUS051 010tSt-2