Loading...
HomeMy WebLinkAboutBlower Door Test ReportResidential Air Infiltration Test Report Test date:9/16/2024 Project name:Bleecher/ Nickolay Address:140 Spirit Mountain Rd Garfield Code:2018 IECC Conditioned volume:55,870 Cubic Feet Attic:unvented, conditioned Crawlspace:conditioned Garage:excluded Measured airflow:1,092 CFM50 Cubic Feet per Minute at 50 Pascal Temperature; Inside:63 Temperature; Outside:66 Elevation:6,180 Corrected airflow:1,131 CFM50*Cubic Feet per Minute at 50 Pascal 2015 IECC maximum allowed leakage rate:3.0 ACH50 Air Changes Per Hour at 50 Pascal Tested air leakage rate:1.2 ACH50 Air Changes Per Hour at 50 Pascal Test code compliance:PASS Test notes: Tests were performed by Chris Taylor; Rated Field Inspector, RFIIN #CY5MPL * Test results have been corrected for elevation and air density temperature differential. Passes the 2018 IECC infiltration requirements.