HomeMy WebLinkAboutRes CheckCOMcheck Software Version 4.1,5.5 Envelope Gompliance Certificate Project lnformation Energy Code: Project Title: Location: Climate Zone: Project Type: Construction Site: Additional Efficiency Package(s) Credits: 1.0 Required 1.0 Proposed On-site Renewable Energy, 1.0 credit Building Area 2018 |ECC Silt, Colorado 5b New Construction Owner/Agent:Designer/Contractor: Floor Area 1-Workshop : Nonresidential 4800 Envelope Assemblies Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factorr"t Roof 1: Metal Building, Standing Seam, Liner System with Thermal Blocks (b), [Bldg. Use 1 - Workshop] Exterior Wall 1: Metal Building Wall, Single Layer Mineral Fiber (in cavity, thermal block at girt), [Bldg. Use 1 - Workshop] 5059 4860 38.0 30.0 0.030 0.052 0.035 0.052 0.0 0.0 (a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. (b) Thermal spacer block with minimum R-3.5 must be installed above the purlin/batt, and the roof deck secured to the purlins. Envelope Gompliance Statement Compliance Statement; The proposed envelope design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed envelope systems have been designed to meet the 2018 IECC requirements in COMcheck Version 4.1.5.5 and to comply with any applicable mandatory requirements listed in the lnspection Checklist. Name - Title Date Envelope PASSES: Design 6% better than code Project Title: Data filename: Untitled.cck Report dale: 08127 124 Page 1 of 11