Loading...
HomeMy WebLinkAboutResCheck Compliance CertificateGenerated by REScheck-Web Software Compliance Ceftificate Proiect Andrus Residence Energy Code: Location: Construction Type: Project Type: Conditioned Floor Area Glazing Area Climate Zone: Permit Date: Permit Number: All Electric ls Renewable Has Charger Has Battery: Has Heat Pump: 20x8 tEcc Garfield County, Colorado Single-famlly New Construction 2,545ltz tZolo s (8499 HDD' false false false false false Construction Site Ow Compliance; 16.90lo Befter Than Code Maximum UA: 326 Your UA: 271 The o/o Better or Worse Than Code lndex reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Slab-on-grade tradeofFs are no longer considered in the UA or pefformance compliance path in REScheck. Each siab-on-grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. Envelope Assemblies N N Ceiling: Flat Ceiling or Scissor Truss Wall: Wood Frame, 16" o.c. Door: Solid Door (under 50% glazing) Window: Vinyl Frame Wall 1: Wood Frame, 16" o.c. Door 1: Glass Door (over 50% glazing) Window Ll Vinyl Frame .Wall 2: Wood Fr€rne, 16" o.c. Door 2: Glass Door (over 50% glazing) Window 2: Vinyl Frame 2,545 742 24 8t 754 96 46 747 48 55 49.0 20.0 0.0 6.0 0.026 0.o42 0.166 0.280 o.042 0.280 0.280 4,442 0.280 0.280 0.026 0.060 0.300 0.300 0.060 0.300 0.300 0.060 0.300 0.300 20.0 6.0 66 27 4 23 26 27 13 27 13 15 66 38 7 24 37 29 L4 39 L4 t7 Compliance: Passes using UA trade-off Cavity R-Value Cont, R-Value Prop, Req, U-Factor U-Factor Gross Area Assembly or Perimeter UA UA Prop. Req, 20.0 6.0 Project Title: Andrus Residence Data filename: Report date: o9lo3l24 Page 1 of10 .t: Cavity R-Value Cont. Prop. Req. Prop R-Value U-Factor U-Factor UA Req UA Gross Area Assembly Perimeter or Wall 3: Wood Frame, 16" o,c, Window 3: Vinyl Frame 567 25 332 20.0 6.0 10.o 0.o42 0.280 0.510 0.060 0.300 0.540 3323 Floor: Slab-On-Grade (Unheated) lnsulation depth: 3.0' lnsulation position: Vertical lnsulation Compliance Statement: The proposed building design described here is consistent with the building plans, specifications. and other calculations submitted with the permit application. The proposed building has been designed to meet the 2018 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REscheck lnspection Checklist. Name - Itue Signature Date 8 0 7 0 Project Title: Andrus Residence Data filename: Report dater O9lO3l24 Page 2 of10 ffi REScheck Software Version I REScheck-Web lnspection Checklist Energy Code: 2018 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "CommentslAssumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Additional Comments/Assumptions: 1 High lmpact (Tier 1)2 Medium lmpact (Tier 2)3 Low lmpact (Tier 3) Field Vertfied Value Complies?Comments/AssumptionsPlans Verified Value Sectaon # & Req.lD Pre-lnspection/Plan Review 103.1, 103.2 lPR1l1 *; I documentation demonstrate ienergy code compliance for the building envelope. Thermal envelope represented on , construction documents. iEruot LlNot Construction drawings and ilComplies [Does Not Observable Applicable 103.1, 103.2, 403.7 lPR3li 'tf- IComplies EDoes Not lflNot observable,Druot applicable I i Construction drawings and ; documentation demonstrate :energy code compliance for dwelling units must demonstrate . compliance with the IECC Commercial Provisions. lighting and mechanical systems. Systems serving multiple 302.1, 403.7 lPR2l2 ti , Heating and cooling equipment is sized per ACCA Manual S based on loads calculated per ACCA ManualJ or other methods approved by the code official. Heating:Btu/hr_ Cooling:Btu/hr_ Heating:Btu/hr_ Cooling:Btu/hr_ :[ooes Not lElNot Observable lflruot applicaole res Project Title: Andrus Residence Data filename: Report date: 09l93l24 Page 3 of10 402.t.2 tFour e Slab edge insulation R-value.R-_ I unneated E tteateo R-_ I unheateo fl Heated lEComplies iEooes ttot ifltrtot Ooservabte iflNst npplieaile see the EflveJope Assernbties table for values, 4AZ.L.2 lFo3l1s Slab edge insulation depth/length. ft ft 4ssembtr'es Not Observable A protective covering is lnstalled to protect exposed exterior lnsutatioft and extends a minimum of 6 in. below grade. ElComplies floses trtot ENot Observable ENot Rppllcable Snow- and lce.melting system controls installod.Not Observable Addtional Cornmcnto/AssutFpttonsl L Medium (Tier ('fier 3) Froject Title: Andrus -Residence Data filename: Repoft date: Ogl0tl24 Page zt oflo Field Verified Value Complies?Comments/Assumptions Section # & Req.lD Framing / Rough-ln lnspection Plans Verified Value 402.7.1, 402.3.4 lFR1l1 :Door U-factor U-U-rSee tfre Envelope Assemblies table for values. ilComplies lDoes Not lflNot Observable iEruot npplicable 402.1.1, 402.3.1, 402.3.3, 442.5 lFR2l1 ;DComplies :Dooes ttot ,ENot observable ,flruot npplicable 'U-U-r Glazing U-factor (area-weighted average). See the Envelope Assemblies table for values. 303.1.3 lFR4l1 'j; : U-factors of fenestration products lare determined in accordance :with the NFRC test procedure or : taken from the default table. .flcomplies 'flDoes Not t[Not Observable flNot Applicable ,ICompliesItlDoes Not ,nNot Observable 4O2.4.1.L :Air barrier and thermal barrier :Dwot cable lFR23l1 installed per manufacturer's instructions. 402.4.3 lFR20l1 :',*.i lflDoes Not if]Not Observable Eruot npplicable:or has infiltration rates ,400 that do not exceed :limits. per NFRCcode : Fenestration that is not site built res , is listed and labeled as meeting r AAMA /WDMA/CSA IOl- ll.S.2l A44O 'Supply and return ducts in attics ;insulated >= R-8 where duct isl>: 3 inches in diameter and >= R-6 where < 3 inches. Supply and return ducts in other portions of the building insulated >= R-6 for res ies for < 3 inches in diameter. 442.4.5 lFR16l2 403.3.1 [FR1211 lC-rated recessed lighting fixtures ' sealed at housing/interior finish and labeled to indicate <2.0 cfm leakaqe at 75 Pa. ,DDoes Not ,DNot Observable DNot Applicable ;[Does Not ,EINot observable flNot Applicable :diameter >= 3 inches and R-4.2 403.3.2 lFR13l1 .a: , Ducts, air handlers and filter 'boxes are sealed with joints/seams compliant with .lnternational Mechanical Code or ' ' lnternational Residential Code, as n Does Not res ,INot Observable '[1Not Applicable 403.3.5 lFR15l3 1: Building cavities are not used as ducts or plenums. : rflComplies :EDoes Not INot Observable rDNot Applicable [Not Observable , l[ruot npplicable , 403.5.3 lFR1812 ;Ecomplies :DDoes Not :flNot Observable :nNot Applicable R-R-Hot water pipes are insulated to >R-3. 2 Medium (Tier 2)3 Low lmpact (Tier 3)1 (Tier 1) Project Title: Andrus Residence Data filename: Report date: 09103124 Page 5 of10 Automatic or gravlty dampers lnstalled on all outdoor air lntakes and exhausts. Addittonal Gomarens/Arsunrptlonrl I (Tier 2)Medium Louu 3) ProjectTitlo; Andrus Resi ence Data filename: R€port datet oiuo3il?4 Page 6 ofL0 All installed insulation is labeled or the installed R-values provided. Not Observable Applicable 402.1^1, 402.2.5, 402.2.6 ltN3l1 * watl insulation R-value, lf thls is a mass wall with at least % of the wall insulation on the wall exterior, the exterlor insulation requirement applies tFRl0). Wood Mass Steel itrruot itrnrot iEComplies iEooet t'tot R. nnn R. ntrn Wood Mass Steel See tbe Envelope .Assemblies table for values. Observable Appllcable Observable Not Wall insulation is installed per manufacturer's instructions. 303,2 ltN4l1 Additlonal Comments/Assumptlons: (Tier 3)Low1(Tier L)H Medium (Tier Project Title: Andrus Residence Data filename: Report date: Ogl03l24 Page 7 ofL0 Sectlon # & Req.lD Final lnspection Provisions Plans Verified Value Field Verified Value 4O2.7.7, . Ceiling insulation R-value. 402.2.I, 402.2.2, ; 402.2.6 lFlul , :lDoes trtot iENot observable iENot Applicable : Complies? R-R- Comments/Assumptions I Wood n Steel I Wood I Steel :See the Envelope Assemblies table for values. 303.1.1.1, iCeiling insulation installed per303.2 manufacturer's instructions.[Fl2]1 tBlown insulation marked every :300 ft2. EComplies 'lllDoes Not flNot Observable : [JNot Applicable Vented attics with air permeable : . insulation include baffle adjacent , ,to soffit and eave vents that extends over insulation. 402.2.3 .IComplies ItlDoes Not ENot Observable flruot npplicable , ACH 50 = R-R- ACH 50 = DNot Applicable lDoes Not mplies ,ilNot Observable 402.2.4 lFt3li Attic access hatch and door insulation >R-value of the adjacent assembly. ,ENot Observable :flNot npplicable 402.4.r.2 tFr17F 'Blower door test @ 50 Pa. <=5 , ach in Climate Zones 1-2, and<:3 ach in Climate Zones 3-8. Ducts are pressure tested to ldetermine air leakage with I either: Rough-in test: Total leakage measured with a pressure differential of 0.1 inch w.g. across the system including ithe manufacturer's air handler enclosure if installed at time of ' test. Postconstruction test: Total ,leakage measured with a pressure differential of 0.1 inch w,g. across the entire system tincluding the manufacturer's air cfm1100 cfm/100 ft2 F- handler enclosure. [lComplies403.3.3 LFt2711 .flooes mot ENot Observable :ENot Applicable :Duct tightness test result of <:4 : cfm/100 ft2 across the system orl<=3 cfm/100 ft2 withoui air ;handler @ 25 Pa. For rough-in ,tests, verification may need to cfmi 100 cfm/100 ft2 E:- Frami Does Not ies403.3.4 lFt4l1 ,flNot Observable rflruot applicable i OCCUr 403.3.2.1 'Air handler leakage designated lFl24l1 ,by manufacturer at <=2o/o af :design air flow. l flDoes Not ENot Observable ENot apnlicable Programmable thermostats installed for control of primary heating and cooling systems and initially set by manufacturer to code specifications. DComplies [Does Not ENot observable ENot applicable 403.1.1 lFt9l2 nComplies,r-l^, , ..uu()es l\ot .nNot observable Etrtot Applicable 403.1.2 IFt10 j2 Heat pump thermostat installed on heat pumps. Circulating service hot water systems have automatic or ' accessible manual controls. ENot Obscrvable , Ittot 403.5.1 lFtl 1 12 lComplies EDoes Not lei I High lmpact (Tier 1)2 Medium lmpact (Tier 2)3 Low lmpact (Tier 3) Project Title: Andrus Residence Data filename: Report date: Ogl13l24 Page 8 of10 403.6.1 512 403.2 lFt2612 All mechanical ventilation system : fans not part of tested and listed ' HVAC equipment meet efficacy and air flow limits per Table R403.6,1. Hot water boilers supplying heat ' ,through one- or two-pipe heating ,systems have outdoor setback , control to lower boiler water temperature based on outdoor IComplies DDoes Not ENot observable flNot Applicable plies ,IDoes Not 'ENot observable .flNot npplicable Section # & Reo.lD Final lnspection Provisions Plans Verified Value Field Verified Value Complies?Comments/Assumptions Heated water circulation systems have a circulation pump. The ,system return pipe is a dedicated return pipe or a cold water supply pipe. Gravity and thermos- syphon circulation systems are , not present, Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop .is at set-point temperature and no demand for hot water exists. 403.5.1.1 IFt28]2 'EComplies :[Does Not [Not Observable :ENot Applicable :Electric heat trace systems . comply with IEEE 515.1 or UL , 515. Controls automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the , piping. ,EComplies flDoes Not ,nNot observable rENot npplicable 403.5.t.2 lFl2912 Demand recirculation water systems have controls that manage operation of the pump and Iimit the temperature of the water entering the cold water . piping to <= 104sF. 'IComplies flDoes Not ENot Observable INot Applicable 403.5.2 lFt3ol2 Drain water heat recovery units tested in accordance with CS,A 855.1. Potable water-side pressure loss of drain water heat recovery units < 3 psi for individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 403.5.4 lFr3112 ICompties ,DDoes trtot ,nNot Observable rflNot Applicable 9oo/o ar more of permanent l fixtures have high efficacy lamps. :IComplies [Does Not iflNot observable :INot npplicable 444.L lFl6l1 DComplies EDoes Not [Not Observable flNot Applicable 404.1.1 lFt2313 Fuel gas lighting systems have no continuous pilot light. Compliance certificate posted.401.3 IFIT 12 [Not Observable ; INot Applicable , Complies Does Not 1 lm (Tier 1)2 Medium I (Tier 2)3 Low I (Tier 3) Project Title: Andrus Residence Data filename: Report date: A9lO3l24 Page 9 ofL0 Manufacturer manuals for mechanical and water heating systems have been provlded. Addtrlbmf Ccmmnte/Arennrp.tior,rel I Project Tltle: Andrus Residence Data l$enarme: Report date: Ogl0gl24 Paqe 10 ofn0 201S IECC Energy Efflcie ncy Cert;fi cate Above-Grade Wall Below-Grade Wall Floor Ceiling / Roof Ductwork (unconditioned spaces) : Window Door Heating System: Cooling Water Name: Comments 26.OO o.oo lo.oo 49.O0 o.28 o.28 Date: Glass & Door Rating U-Factor SHGC