Loading...
HomeMy WebLinkAboutCompaction Report 09.13.2024Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%) Optimum Moisture Tolerance (%)Remark 3 09/13/24 263-24 C (D698)SP-SM 7.3 133.8 5.4 134.5 141.8 8 101 98 -2 / 2 DP/MP 4 09/13/24 263-24 C (D698)SP-SM 7.3 133.8 5.6 135.6 143.2 8 101 98 -2 / 2 DP/MP 5 09/13/24 263-24 C (D698)SP-SM 7.3 133.8 6.0 135.6 143.7 8 101 98 -2 / 2 DP/MP 6 09/13/24 263-24 C (D698)SP-SM 7.3 133.8 5.6 133.1 140.6 8 99 98 -2 / 2 DP/MP 7 09/13/24 263-24 C (D698)SP-SM 7.3 133.8 5.3 132.7 139.7 8 99 98 -2 / 2 DP/MP 8 09/13/24 263-24 C (D698)SP-SM 7.3 133.8 5.5 132.9 140.2 8 99 98 -2 / 2 DP/MP 9 09/13/24 263-24 C (D698)SP-SM 7.3 133.8 6.6 134.1 142.9 8 100 98 -2 / 2 DP/MP Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 3 Structural Fill: Structural fill beneath footings. 10' East and 2' North of Southwest corner. 0.0 Footer subgrade Troxler / 3440 / 24678 / 04/12/2024 Wyatt Cummings 4 Structural Fill: Structural fill beneath footings. 20' North and 2' West of Southwest corner. 0.0 Footer subgrade Troxler / 3440 / 24678 / 04/12/2024 Wyatt Cummings 5 Structural Fill: Structural fill beneath footings. 2' North and 20' West of Southeast corner. 0.0 Footer subgrade Troxler / 3440 / 24678 / 04/12/2024 Wyatt Cummings 6 Structural Fill: Structural fill beneath footings. 40' West and 10' North of Southeast corner. -1.0 Footer subgrade Troxler / 3440 / 24678 / 04/12/2024 Wyatt Cummings 7 Structural Fill: Structural fill beneath footings. 40' West and 10' North of Southeast corner. 0.0 Footer subgrade Troxler / 3440 / 24678 / 04/12/2024 Wyatt Cummings 8 Structural Fill: Structural fill beneath footings. 50' West and 15' North of Southeast corner. 0.0 Footer subgrade Troxler / 3440 / 24678 / 04/12/2024 Wyatt Cummings 9 Structural Fill: Structural fill beneath footings. 20' West Northeast corner.-1.0 Footer subgrade Troxler / 3440 / 24678 / 04/12/2024 Wyatt Cummings Remarks DP/MP: Density Pass / Moisture Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. This report presents opinions formed as a result of our observations of soil compaction. We have relied on the contractor to continue applying the recommended compactive effort and moisture to the fill during times when our observer is not observing operations. Tests are made of the soils only as believed necessary to calibrate our observer¶s judgement. Test data are not sole basis for opinions on whether the soils meets specifications. These test results only apply to the samples which were tested. The testing report shall not only be reproduced, except in full, without the written approval of Kumar and Associates, Inc. Nuclear gauge density testing performed in accordance with ASTM D6938. Page 1 of 1 Soil Compaction Report Test Method: ASTM D 6938 Client: Jesus H. Salinas Glenwood Springs, CO 81602 P.O. Box 1799 Project: Lot 3, Mineota Estates 22-7-121.A Silt, CO 81652 Mineota Drive 5020 County Road 154 Glenwood Springs, CO 81601 Phone: 970-945-7988 Glenwood Springs