Loading...
HomeMy WebLinkAboutPermit Card Garfield County Public Health 2014 Blake Ave. Glenwood Springs, CO 81601 Phone: (970) 945-6614 ext. 8150 For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable Project Address: 1547 Main Street, Silt, CO Parcel No.: 217910100026 Owner Name: 3M Investors, LLC Owner Phone: (970) 200-6020 Designed By: Boundaries Unlimited, Inc. Designer Phone: (970) 945-5252 Contractor: Moore Construction Contractor Phone: (970) 618-5244 Number of Bedrooms: _N/A_ Minimum Tank Capacity: Existing Minimum Absorption: 2,398 ft2 OWTS PERMIT KEEP AVAILABLE AT PROJECT SITE Permit Number _SEPT-8878_______________________________ Permit Type X New X Repair X Remodel/addition X Tank only Issue Date _09/26/2024____________________ Expiration Date_09/26/2025_________________ Permit Conditions: This OWTS Permit is approved on the condition of compliance with the report and design as submitted by Boundaries Unlimited, Inc. dated September 25, 2024. Changes to the design and permit must be approved by Garfield County Public Health and the designer prior to construction. The new OWTS will expand an existing OWTS and serve an existing three-bedroom residence, six one- bedroom residences and 2 Recreational Vehicle (RV) spots. The design recommends utilizing the existing 1,000-gallon two compartment septic tank and the existing 2,000-gallon single compartment tank with a high-head pump. Access to the tanks is provided at grade. Effluent will be pumped to a new Automatic Distributing Valve (ADV) set at the high point of the system to distribute effluent to a total of 3,744 ft2 of STA. The new STA will consist of two chamber beds consisting of four rows of 13 Quick4 chambers (52 chambers per bed, 104 new chambers, 312 chambers total for the system). Transport lines from the pump chamber are to be 1 ½ inch Schedule 40 PVC. Distribution laterals are to be 1 ¼ inch Schedule 40 PVC with 3/16-inch orifices every 4-feet on center and the laterals ending in flushing valves at the distal end of the laterals. The orifices are to be facing upward. Inspection ports are to be installed at each corner of each bed. The residual head (squirt height) at the end of the system is to be 5-feet. Maintain all setbacks and elevations as designed. To assist in scheduling, please contact Garfield County Public Health (970-945-6614 ext. 8150) to notify the start of OWTS construction. Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final inspection of the installed system prior to backfill. NO OWTS COMPONENT SHALL BE BACKFILLED WITHOUT PRIOR APPROVAL FROM GARFIELD COUNTY PUBLIC HEALTH AND THE DESIGNER. Agreement All installations must comply with all requirements of the Garfield County OWTS regulations including but not limited to the conditions specified above. In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location, construction, and erection of the proposed OWTS and associated structures for which this permit is granted. The applicant further agrees that if the above said regulations are not fully complied with in the zoning, location, erection, and construction of the above described OWTS and structure, the permit may then be revoked by notice from the Health Department and immediately become null and void. The issuance of a permit and specifications of terms and conditions therein will not constitute assumption of liability, nor create presumption that the local public health agency or its employees may be liable for the failure or malfunctioning of any system. Permit issuance will not constitute a certification that the system, the equipment used in the system, or any component used for system operation will ensure continuous compliance with the provision of the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit. Permit Approval Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as-built" drawing must be submitted and inspection of the system must be completed by GCPH before final approval of the system will be issued. 09/26/2024 Issued By: Garfield County Environmental Health Department Date