HomeMy WebLinkAboutEngineer's OWTS Design Plan and Spec SheetsI29 CAINS L.ANE CARBONDALE, CO 41623 970.309.5259 CARI.A. oSTBER G@GMAIL.coM sttt>'l'Ia1 ( 1(ti\st l r-'|'IhI(* August 19,2024 Project No. C1906 Todd Chapman poolscum@vahoo.com Subsurface lnvestigation and Onsite Wastewater Treatment System Design 1-Bedroom Accessory Dwelling Unit (ADU) 291 CR 119 Garfield County, Colorado Todd, CBO lnc. performed a subsurface investigation and completed an onsite wastewater treatment system (OWTS) design for the subject residence^ The 10.17S-acre property is located outside of Glenwood Springs, in an area where OWTSs and wells are necessary. Legal Description: Section: 30 Township: 6 Range: 88 Subdivision: CHRISTELEIT SUB AMD Lot: A 10.175 ACRES Parcel lD: 2187-302-01 -001 SITE CONDITIONS The property is cunently developed with a 4-bedroom residence, constructed in 1992. This residence is served by a separate OWTS that is not addressed in this design. A 1-bedroom Accessory Dwelling Unit (ADU) is proposed and will be served by the OWTS described in this design. The ADU will be served by a private well on the property. The well is located to the west of the proposed ADU" The well is located greater than S0-feet from the proposed septic tank and greater than 100-feet from the proposed soil treatment area (STA). The property slopes to the north and northeast towards the County Road. The proposed STA location has an approximate 10% slope and is vegetated with sage and native grasses. There should be no traffic or staging of material over the future STA site to avoid compaction of soils prior to construction of the STA. SUBSURFACE The subsurface was investigated on July 8,2024 by digging two soil profile test pit excavations (Test Pits). A visual and tactile soil analysis was completed by Carla Ostberg at the time of excavation.l The materials encountered in Test Pit #1 consisted of dark brown loamy topsoil to 3.0-feet, underlain by dense, whitish calcareous clay matrix to a maximum depth explored of 4.0-feet where practical digging refusalwas encountered on a large boulder. No bedrock or groundwaterwas encountered. I Carla Ostberg holds a Certificate of Attendance and Examination from the CPOWVisual and Tactile Evaluation of Soils Training. Page2 The materials encountered in Test Pit #2 consisted of dark brown loamy topsoil to 18-inches, underlain by whitish calcareous clay matrix to a maximum depth explored of 7.0-feet. No bedrock or groundwater was encountered. A sample of the soil was taken from Test Pit #1 at 3-feet below grade. Soil structure grade was moderate. The soilformed a ball and a ribbon less approximately 1-inch in length before breaking. Soil structure shape was blocky and consistence was friable. Soil texture was more smooth than gritty. We have researched soils in the area through USGS Web Soil Survey. The report is enclosed. The area of the proposed STA is identified by map unit symbols 19 and 85. The map unit names are Cochetopa- Antrobus association, 25 to 50% slopes, and Morval Loam, 6to25o/o slopes. Both the loamy topsoil and calcareous clay matrix are consistent with Soil Type 2 with moderate structure grade. A long-term acceptance rate (LTAR) of 0.6 gallons per square foot will be used to design the STA. Test Pit #1 / deeper topsoil horizon Page 3 Test Pit #1 / difficult digging with small machine Sieved sample from Test Pit #1 at 3' / topsoil with calcareous clay matrix / ribbon less than 1" Test Pit #2 excavated to 7' Page 4 Desiqn Calculations: Average Design Flow = 75 GPD x 2 people/bedroom x 2 Bedrooms = 300 GPD LTAR = 0.6 GPD/SF 300 GPD / 0.6 GPD/SF = 500 SF x 1,2 (gravity, bed) x 0.7 (chambers) - 420 SF Although the proposed ADU willhave only 1-bedroom, the OWTS design is based on 2-bedrooms2. An average daily wastewater flow of 300 GPD will be used. For the purposes of this OWTS design, Benchmark Elevation has been established as 100' (Finished Floor). GBO lnc. should be notified of any discrepancies or problems with grade elevations of proposed components during installation of the OWTS. *Elevations are based upon standard OWTS installation practices. Component elevations may change during installation due to site conditions. Minimum grade refers to piping between components. The 4-inch SDR-35 sewer line exiting the ADU must have a double-sweep clean out and a minimum 2% grade to the septic tank. The system installation must include a 100O-gallon, two-compartment lnfiltrator@ poly septic tank with an Orenco@ Biotube effluent filter on the outlet tee. Any state-approved poly or concrete septic tank may be substituted. Risers must bring the manhole lids to grade for access. lf more than one riser is added to the septic tank, an extension handle must be installed on the effluent filter. A 4-inch diameter SDR-35 level manifold must be installed to connect each row of the chamber bed. The chamber bed will consist of 3 rows of 12 'Quick 4' lnfiltratol@ chambers for a total of 36 chambers and 432 square feet of infiltrative area. lnspection ports must be installed at each corner of the bed. Ports may be cut to grade and placed in sprinkler boxes for access. COMPONENT SPECIFICATIONS The component manufacturers are typical of applications used by contractors and engineers in this area. CBO lnc. must approve alternative components prior to installation of the OWTS. Requests must be submitted, in writing, to our office for approval prior to installation. Component technical data sheets are available upon request. 2 Garfield County OWTS Regulation 43.6.A. 2. c. "The minimum design flow for a new home must be for a two- bedroom house unless otherwise noted in this regulation..." OWTS Gomponent Minimum Elevation Primary Tank lnlet lnvert Approximate horizontal distance 16' / min. 2o/o tall I min.4" fall lnfiltrative Surface Approximate horizontal distance 43' / min. 1% fall to STA / min. 5.375" fall COMPONENT MANUFACTURER MODEL NO.COMMENTS Septic Tank lnfiltrator@ rM-1060-2CP 1000-gallon, two- compartment poly septic tank Effluent Filter Orenco@ 4" diameter full size filter Tank Risers and Lids Orenco@ Double-walled PVC Risers and Lids (24" diameter) Chambers lnfiltrator@ Plus Standard Chambers 36 'Quick 4' Chambers Page 5 Construction must be according to the jurisdiction's adopted On-Site Wastewater Treatment System Regulations, the OWTS Permit, and this design. PERMIT APPLICATION INSTRUCTIONS An OWTS Permit Application must be submitted to Garfield County Environmental Health Department https://www.qarfield-countv.com/environmental-health/filesqcco/sites/16/OWTS-Application-Comolete- Packet-Dec.-2019.pdf. lf the OWTS Permit Application will be submitted with a Building Permit Application, it should be submitted directly to Garfield County Building Department. Allquestions regarding permit submission can be directed to Garfield County Environmental Health Department, 970-945-6614 x81 50. INSTALLATION CONTRACTOR CBO lnc. expects that the installer be experienced and qualified to perform the scope of work outlined in this design. The installer must review this design thoroughly and coordinate with our office in advance of installation. Any additionalconditions in this design or county permit must be completed and documented prior to final approval of the OWTS installation. Communication between the installer and this office is expected throughout the installation. INSTALLATION OBSERVATIONS CBO lnc, must view the OWTS during construction. The OWTS observation should be performed before backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing siphons, and other plumbing, as applicable, must also be observed. CBO lnc. should be notified 48 hours in advance to observe the installation. ln an effort to improve the accuracy of the record drawing, we request that the installer provide a sketch of the installation, including path of the sewer lines, water line installation (if applicable), septic tank location, STA location, and measurements from building comers or another fixed objects on the property. This sketch is most easily provided on Sheet W2.0 of the OWTS Design Packet. Photographs of the installation and final cover are also requested to supplement our installation documentation. REVEGETATION REQUIREMENTS An adequate layer of good quality topsoil capable of supporting revegetation shall be placed over the entire disturbed area of the OWTS installation. A mixture of native grass seed that has good soil stabilizing characteristics (but without taproots), provides a maximum transpiration rate, and competes well with successional species. No trees or shrubs, or any vegetation requiring regular irrigation shall be placed over the STA. Until vegetation is reestablished, erosion and sediment control measures shall be implemented and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation cover. OPERATION INFORMATION AND MAINTENANCE The property owner shall be responsible for the operation and maintenance of each OWTS servicing the property. The property owner is responsible for maintaining service contracts for manufactured units, alternating STAs, and any other components needing maintenance. Geo-fabrics or plastics should not be used over the STA. No heavy equipment, machinery, or materials should be placed on the backfilled STA. Machines with tracks (not wheels) should be used during Page 6 construction of the STA for better weight distribution. Livestock should not graze on the STA. Plumbing fixtures should be checked to ensure that no additionalwater is being discharged to OWTS. For example, a running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a STA. lf an effluent filter or screen has been installed in the OWTS, we recommend this filter or screen be cleaned annually, or as needed. lf the OWTS consists of a pressurized pump system, we recommend the laterals be flushed annually, or as needed. The homeowner should pump the septic tank every two years, or as needed gauged by measurement of solids in the tank. Garbage disposal use should be minimized, and non-biodegradable materials should not be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS. Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste only. ADDITIONAL CONSTRUCTION NOTES lf design includes a pump, weep holes must be installed to allow pump lines to drain to minimize risk of freezing. The pump shall have an audible and visual alarm notification in the event of excessively high- water conditions and shall be connected to a control breaker separate from the high-water alarm breaker and from any other control system circuits. The pump system shall have a switch so the pump can be manually operated. Excavation equipment must not drive in the excavation of the STA due to the potential to compact soil. Extensions should be placed on all septic tank components to allow access to them from existing grade. Backfill over the STA must be uniform and granular with no material greater than minus 3-inch. LIMITS: The design is based on information submitted. lf soil conditions encountered are different from conditions described in report, CBO lnc. should be notified. All OWTS construction must be according to the county regulations. Requirements not specified in this report must follow applicable county regulations. The contractor should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. Licensing of Systems Contractors may be required by county regulation. Please call with questions. Sincerely, CBO lnc. (s.n(* }stblr'.o6 Carla Ostberg, MPH, REHS TP1 SEPTIC TANK STA TP2 POSED 1-BEDROOM ADU/SHOP ISTING BUILDING THE LOCATION OF PROPOSED IMPROVEMENTS SHOWN ARE NOT THE RESULT OF A PROPERW SURVEY, THE LOCATIONS ARE APPROXIMATE. IT IS THE HOMEOWNERS'DUTY TO ENSURE ALL CONSTRUCTION AND IMPROVEMENT LOCATIONS ARE ACCURATE. PROPERry LINES AND SETBACK DISTANCES SHOULD BE CONFIRMED PRIOR TO EXCAVATION. SCALED FOR PRINTING ON 11" X17" PAPER. '.':: F.. ni. ::: : ti,l: Ghapman ADU 291 CR 119 Garfield County, Colorado Project Number: C1906 Date: 0811912024 Designed by:CBO Drawn by: DD w1 .0 Sheet 1 0F 4 CBO lnc. 129 Cains Lane Carbondale, Colorado 81623 Phone 970.309.5259 carla.ostberg@gmail.com 4' DIA SDR-35 SEWER LINE TO EACH TRENCH (MIN. 1% SLOPE TO TRENCH) SLIP.ON PVC CAP DO NOT GLUE INSULATED INFILTRATOR END PLATE GMVELESS'QUICK-4' CHAMBERS (4' x 3')TRACERWIRE FINISHED GRADE 4' DIA SDR.35 EFFLUENT PIPE (MrN. 1% FALL FROM SEPTTC TANK) 4'DIA SEWER LINE 12 CHAMBERS PER ROW 4" DIA SDR.35 INSPECTION PORT AT EACH CORNER OF STA TO TANK HOUSE 4" DIA SDR.35 PVC LEVEL MANIFOLD - PIPES PLACED IN TOP PORT OF CHAMBER END PLATES 4" SDR 35 PVC INSPECTION PORTAT EACH CORNER OF STA TNFTLTMTOR(R) QUTCK4(TM) CHAMBERS, 3X4' SMALL VALVE COVER BOX OR IRRIGATION VALVE BOXAT GMDE ATTACH CAP ORTHREADED CLEANOUT ASSEMBLY 4' 2',IN COMPACT SOIL BASE TO SUPPORT BOX 4- PVC PIPE CUT TO FIT SCARIFY SURFACE EXTENT OF EXCAVATION USE HOLE SAWTO CUT THRU TOP OF END PLATE AMBER IIT BACKFILL MUST BE MINUS 3-INCH MATERIAL CBO lnc. 129 Cains Lane Carbondale, Colorado 81 623 Phone 970.309.5259 carla.ostberg@gmail.com Chapman ADU 291 CR 119 Garfield County, Colorado Project Number: C1906 Date: 0811912024 Designed by: CBO Drawn by: DD w3.0 Sheet 3 0F 4 DESIGN PROPOSED 1-BEDROOM ADU/SHOP (sizing for2 bedrooms) (75 GPD x 2 PERSONS/BEDROOM x 2 BEDROOMS) WASTEWATER FLOW = 300 GPD USE MIN. lOOO GALLON, TWO-COMPARTMENT SEPTIC TANK SOIL TREATMENT AREA (STA): LONG TERM ACCEPTANCE RATE (LTAR) = 0.6 GAU SF CALCULATED STA = Q/LTAR = 300 / 0.6 = 500 SF 500 SF X 1.2 (GRAVITY, BED) X 0.7 (CHAMBERS) = 420 SF 420 SF I 12 SFICHAMBER = MlN. 35 CHAMBERS 3 ROWS OF 12 'QUICK 4' CHAMBERS IN A BED CONFIGURATION SOIL PROFILE TEST PIT NO. 1 SOIL PROFILE TEST PIT NO.2 LEGEND trq topsoit m calcareous clay matrix 0 1 2 3 4 5 6 7 8 I 10 DARK BROWN TOPSOIL WITH A WHITISH CALCAREOUS CLAY MATRIX DARK BROWN TOPSOIL FINISHED GMDE WHITISH CALCAREOUS CLAY MATRIX WHITISH CALCAREOUS CLAY MATRIX F UJ [rJll- I IFLul6 24',MlN. DIGGING REFUSAL ON LARGE BOULDER 4'DIA SDR-35 SEWER LINE (MrN 2% SLOPE TO TANK) NO GROUNDWATER OR BEDROCK ENCOUNTERED DURING EXCAVATION SCREENED OR SAND FOR BEDDING 3" MlN. 8'MlN. TR OWTS COMPONENTS AND PHYSICAL FEATURES MINIMUM REQUIRED SETBACK APPROXIMATE PROPOSED SETBACK HOUSE TO SEPTIC TANK 5'16' SEPTIC TANKTO WELL 50'235', SEPTIC TANK TO WATER COURSE 50'N/A STATO HOUSE 20'70' STATO WELL 100'289' STA TO WATER COURSE 50'N/A BACKFILL Chapman ADU 291 CR 119 Garfield County, Colorado Project Number: C1906 CBO lnc. 129 Cains Lane Garbondale, Colorado 81623 Phone 970.309.5259 carla.ostberg@gmail.com Date: 0811912024 Designed by: CBO Drawn by: DD w4.0 Sheet 4 0F 4 = h F, 3 Eo io A Soil Map-Aspen-Gypsum Area, Colorado, Parts of Eagle, Garfield, and Pitkin Counties; and Rifle Area, Colorado, Parts of Garfield and Mesa Counties 30m ffi/o 305m w70 304@ 305@ s5c70 s110 305ts)sls 305A 3Mn s5310 ffi l,lap Scah: 1:2,090 itprinEd on A landscape (11" x 8.S) $e€t+ ,lvlebls030@1n180 - 'Feet01m2m4S6m plap troi:dion: Wbb Mercator ConErcoodirffi: WGS84 Rlgetics: UTM Zo,rE 13N WGS84 ffi 39p 3045 N 390 3o36',N o F* 3ff 3046'N 39p 3036"N I F E I t. I q $h Iilt q Ee I F E B s 3 + h Ro 3 b E N A 3053S t6DA - Natral Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 8t2712024 Page 1 of4 Soil Map-Aspen-Gypsum Area, Colorado, Parts of Eagle, Garfield, and Pitkin Counties; and Rifle Area, Colorado, Parts of Garfield and Mesa Counties MAP LEGEND MAP INFORMATION Area of lnterest (AOl) Soils Natural Resources Conservation Service Area of lnterest (AOl) El Spoil Area 0 Stony Spot ffi Very Siony SPot $ wet Spot & Other .. Special Line Features Water Features Streams and Canals Transportation ga1 Rails -d lnterstate Highways *nidf US Routes :r:l:rrr Major Roads Local Roads Background I Aerial Photography I Soil Map Unit Polygons # Soil Map Unit Lines I Soil Map Unit Points Special Point Features E, Blowout Hl Borrow Pit H Glay Spot S Closed Depression H Cravel Pit J" Gravelly Spot f;! Landfill ff," Lava Flow & Marsh orswamP tr Mine or Quarry S Miscellaneous \ hter € Perennial \Aibter tf Rock Outcrop + Saline Spot :,: sandy spot €t Severely Eroded SPot S Sinkhole F Slide or Slip @ Sodic Spot The soil surveys that comprise your AOI were mapped at 1:24,000. Warning: Soil Map may not be valid at this scale. Enlargement of maps beyond the scale of mapping can cause misunderstanding of the detail of mapping and accuracy of soil line placement. The maps do not show the small areas of contrasting soils that could have been shown at a more detailed scale. Please rely on the bar scale on each map sheet for map measurements. Source of Map: Natural Resources Conservation Service Web Soil Survey URL: Coordinate System: Web Mercator (EPSG:3857) Maps from the Web Soil Survey are based on the Web Mercator projection, which preserves direction and shape but distorts distance and area. A projection that preserves area, such as the Albers equal-area conic projection, should be used if more accurate calculations of distance or area are required' This product is generated from the USDA-NRCS certified data as of the version date(s) listed below. Soil Survey Area: Aspen-Gypsum Area, Colorado, Parts of Eagle, Garfield, and Pitkin Counties SurveyArea Data: Version'14, Aug 23,2023 Soil Survey Area: Rifle Area, Colorado, Parts of Garfield and Mesa Counties Survey Area Data: Version 16, Aug 22,2023 Your area of interest (AOl) includes more than one soil survey area. These survey areas may have been mapped at different scales, with a different land use in mind, at different times, or at different levels of detail. This may result in map unit symbols, soil properties, and interpretations that do not completely agree across soil survey area boundaries. Soil map units are labeled (as space allows) for map scales 1:50,000 or larger. Date(s) aerial images were photographed: Aug 25, 2021-Sep 5,2021 USDA - Web Soil Survey National Cooperative Soil Survey 8t27t2024 Page 2 of 4 Soil Map-Aspen-Gypsum Area, Colorado, Parts of Eagle, Garfield, and Pitkin Counties; and Rifle Area, Colorado, Parts of Garfield and Mesa Counties MAP LEGEND MAP INFORMATION The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor of unit boundaries be evident. USD{ - I Natuial Resources Con#rvation Service I Web Soil Survey National Gooperative Soil Survey 8t27t2024 Page 3 of4 i soil Map-Aspen-Gypsum Area, colorado, Parts of Eagle, Garfield, and Pitkin counties; and Rifle Area, Colorado, Farts of Garfield and Mesa Counties Map Unit Legend 45.20/o9.9Cochetopa-Antrobus association, 25 to 50 Percent slopes 19 14-60/o3.2Kilgore silt loam69 25.8o/o5.7Morual loam, 6 to 25 Percent slopes 85 85.6%18.8Subtotals for Soil SurveY Area 100.07o21.9Totals for Area of lnterest Percent.olAOI" AcrEs inAolUapUnltNdrno, llap UnitgYmbol 14.4o/oMorval loam, 3 to 12 Percent slopes 44 14.4o/o3.2Subtotals for Soil SurveY Area 100.0%21.9Totals for Area of lnterest Natural Resources Conservation Service Web Soil SurveY National Cooperative Soil SurveY 8t2712024 Page 4 of4USDA - Map Unit Description: Cochetopa-Antrobus association, 25 to 50 percent slopes--Aspen- Gypsum Area, Colorado, Parts of Eagle, Garfield, and Pitkin Counties; and Rifle Area, Colorado, Parts of Garfield and Mesa Counties Aspen-Gypsum Area, Colorado, Parts of Eagle, Garfield, and Pitkin Counties 1 9-Gochetopa-Antrobus assoc iati on, 25 to 50 percent slopes Map Unit Setting National map unit symbol: iq54 Elevation: 8,500 to 10,500 feet Mean annual precipitation: 18 to 20 inches Mean annualairtemperature: 36 to 38 degrees F Frost-free period: 45 to 60 days Farmland classification; Not prime farmland Map Unit Gomposition Cochetopa and similar soils: 45 percent Antrobus and similar soi/s; 40 percent Minor components: 15 Percent Estimates are based on observations, descriptions, and transects of the mapunit. Description of Cochetopa Setting Landform: Fans, mountains La n dfo rm position (th re e-d i me n si on al) : Lower th i rd of mountai nflan k Down-slope shape: Linear Across-slope sh ape : Linear Parent material: Alluvium derived from basalt Typicalprofile Hl -0 fo3inches: loam H2 - 3 to 38 inches; clay loam H3 - 38 to 60 inches: gravelly clay loam Properties and qualities S/ope: 25 to 40 percent Depth to restrictive feature: More than 80 inches Drai nage class: Well drained Runoff class: Very high Capacity of the most limiting layer to transmit water (Ksat): Moderately high (0.20 to 0.60 in/hr) Depth to water fable; More than B0 inches Frequency of flooding: None Frequency of ponding: None Available water supply, 0 to 60 inches: High (about 10.4 inches) lnterpretive groups La nd capability classifieation (i rrigated); None specified Land cap ability classificatio n (non i nig ated) : 7 e Hydrologic Soil Group: C Ecologicalsrfe: R048AY250CO - Subalpine Loam IJSDA - Natural Resources Gonservation Service Web Soil Survey National Cooperative Soil Survey 8t27t2024 Page 1 of3 Map Unit Description: Cochetopa-Anttobus association, 25 to 50 percent slopes--Aspen- Gypsum Area, Colorado, Parts of Eagle, Garfield, and Pitkin counties; and Rifle Area, Colorado, Parts of Garfield and Mesa Counties Oth e r veg etative cl assification j subalpine loam (n u ll-84) Hydric so,7 rafing; No Description of Antrobus Setting Landform: Fans, mountains La ndfo rm positio n (th re e-di me n si on al) : Lower th ird of mou ntainflan k Down-sloPe shaqe: Linear Across-s/op e sh aPe : Linear Parent material: Alluvium derived from basalt and/or colluvium derived from basalt Typical profile H1 - 0 to 13 inches: very stonY loam H2 - 13 to 60 inches: extremely stony loam Properties and qualities S/ope: 30 to 50 Percent Depth to restrictive feature: More than 80 inches Drainage c/ass; Well drained Runoffclass: High Capacity of the most limiting layer to transmit water (Ksat): Moderately high to high (0'20 to 2.00 in/hr) Depth to water fable; More than 80 inches Frequency of flooding: None FrequencY of Ponding: None Catcium carbonate, maximum content: 1 0 percent Maximum salinity: Nonsaline to very slightly saline (0'0 to 2.0 mmhos/cm) Availabte water suppty, 0 to 60 inches: Low (about 3.4 inches) lnterpretive groups Land capability classification (inigated): None specified Land capability classification (nonirrigated): 7 e Hydrologic Soil GrouP: B Ecologicalslfe; R048AY237CO - Stony Loam Othe r vegetative classification: Stony Loam (null*82) Hydric so/ rafrng; No Minor Gomponents Other soils Percent of maP unit: 15 Percent Oth e r v e g etative c I assif icafrbn ; S OT ( n u I l-80) Natural Resources Conservation Service Web Soil Survey National Cooperative Soil SurveY 812712024 Page 2 of 3USDA - Map Unit Description: Cochetopa-Antrobus association, 25 to 50 percent slopes--Aspen- Gypsum Area, Colorado, Parts of Eagle, Garfteld, and Pitkin Counties; and Rifle Area, Golorado, Parts of Garfield and Mesa Counties Hydric soi/ rafingi No Data Source lnformation {t SoilSurvey Area: Pitkin Counties Survey Area Data: Soil Survey Area: Survey Area Data: Aspen-Gypsum Area, Colorado, Parts of Eagle, Garfield, and Version 14, Aug 23,2423 Rifle Area, Colorado, Parts of Garfield and Mesa Counties Version 16, Aug 22,2023 Natural Resources Conservation Service Web Soil SurveY National Cooperative Soil SurveY 8t27t2024 Page 3 of 3TISDAva Map Unit Description: Morval loam, 6 to 25 percent slopes--Aspen-Gypsum Area, Colorado, Parts of Eagle, Garfield, and Pitkin Counties; and Rifle Area, Colorado, Parts of Garfield and Mesa Counties Aspen-Gyp$um Area, Golorado, Parts of Eaglen Garfield, and Pitkin Counties 85-Morval loam, 6 to 25 percent slopes Map Unit Setting National maP unit sYmbal: iq7h Elevation: 6,800 to 8,000 feet Mean annual precipitation: 14 to 16 inches Mean annual air temperature: 42 to 44 degrees F Frost-free period: 85 to 95 daYs Farmland classification; Not prime farmland Map Unit Composition Morual and similar so/s: 85 Percent Minor components: 15 Percent Esfmafes are based on obseruations, descriptions, and fransecfs of the mapunit. Description of Morval Setting Landform : Alluvial fans Down-slope shaPe: Linear Across-s/op e sh aPe: Linear Parent material: Alluvium derived from sandstone and shale and/or colluvium derived from sandstone and shale Typical profile H1 -}toTinches: loam H2 -7 to 19 inches: claY loam H3 - 19 to 60 inches: loam Properties and qualities S/ope:6 to 25 Percent Depth to restrictive feature: More than B0 inches Drainage c/ass; Well drained Runoff class: High Capacity of the most limiting layer to transmit water (Ksat): Moderately high (0.20 to 0.60 in/hr) Depth to water table: More than 80 inches Frequency of floodlng: None Frequency of Pondrng; None Calcium carbonate, maximum content: 25 percent Maximum satinity: Nonsaline to slightly saline (0.0 to 4'0 mmhos/cm) Avaitabte water supply, 0 to 60 inches: High (about 9.3 inches) lnterpretive groups La nd capability cl assification (irrigated.); None specifi ed Land capability classification (nonirrigated): 6e Hydrologic Soil GrouP: C Natural Resources Conservation Seryice Web Soil Survey National Cooperative Soil SurveY 9t112024 Page 1 ot 2USDA - l, Map Unit Description: Morval loam, 6 to 25 percent slopes--Aspen-Gypsum Area, Golorado, Parts of Eagle, Garfield, and Pitkin Counties; and Rifle Area, Colorado, Parts of Garfield and Mesa Counties Ecologicalsde; R048AY292CO - Deep Loam Other vegetative classification: DEEP LOAM (null-11) Hydric so,l rafrng: No llllinor Gomponents Other soils Percent of maq unit: 15 Percent Hydric soil rating: No Data Source lnformation Soil Survey Area: Pitkin Counties Survey Area Data Soil Survey Area: Survey Area Data Aspen-Gypsum Area, Colorado, Parts of Eagle, Garfield, and Version 14, Aug 23,2A23 Rifle Area, Golorado, Parts of Garfield and Mesa Counties Version 16, Aug 22,2023 Natural Resources Conseryation Service Web Soil Survey National Cooperative Soil Survey 9t1t2024 Page 2 ot 2 t}SDA - '9t1t24,9:24AM Garfield County, CO Summary Account Parcel Propefi Address Legal Descrlptlon Acr€s LandSqFt TaxArea Mllltevy Subdlvlslon Building# Unlts BuildingTYpe Abstract Codes / (Properry Type) Archltectural Style Storles Frame A€turlY.rfBuilt . Gross LivingArea Total Heated SqFt Bedrooms Baths Heating Fuel HeatingType AlrCondltloning RooflVpe RoofCover qPublic.net - Garfield County, CO - Property Recod Card: R050227 RO50227 2187.3f)2DIOO7 291 119 COUNW RD, GLENWOOD SPRINGS, CO 81601 Section: 30 Township: 6 Range: 88 Subdivision: CHRISTELEIT SUB AMD Lot A 10.175 ACRES 70.175 o 5 &.954o CHRISTELEITSUBAMD Map ViewMao Owner CHAPMAN,TODDD 291COUNWROAD119 GLENWOOD SPRINGS CO 81601 Land Unit Typ€ SINGLE FAM.RES'LAND - 1112 (RESIDENTIAL PROPERTY) SquareFeet O Buildings L I SFR SINGLE FAM.RE9IM PROVEMTS.12I2 (RESIDENTIAL PROPERTY) 2-STORY 2 WOODFMME 1992 2,638 2,638 4 2 GAS HOTWATER NONE GABLE COMPSHNGL hftps://qpublic.schneidercorp.com/Application.aspx?ApplD=1038&LayerlD=22381 &PageTypelD=4&PagelD=9,147&Q=1999075260&KeyValue=R050227 1t3 911124,9:244M ActualValues TaxYear Actualvalue AssessedValues Tax Year Assessed Value Sale Date !2/6/2079 u2p/2oo2 sl2noco 9n6/1994 9/L711992 qPublic.net - Garfield County, CO - Property Record Card: R050227 TaxHistory Tax Year Taxes Billed 2023 $3624.32 Click here to viewthe tax informationfor this oarcel on the Garfield CountvTreasurer's website. Transfers DeedTYpe SPECIALWARRANTY DEED QUITCLAIM DEED QUITCLAIM DEED WARRANWDEED WARRANTYDEED 2024 $882470.00 2024 $s9.460.00 2023 $887,470.00 2023 $59,460.00 2022 $s68,220.00 2022 $39,490.00 2022 $2,6e2.36 20'21 $568120.q) 2027 $40,530.(n 2021 $2729.O8 2420 $s34780.00 202r) $38,2.10.00 2020 $2,sss24 Sale Prlce $658500 $s1,ooo Recaptlon Number 929L37 se6+q2 sq!ry Fin+q. 439143 Book- Page 7324-517 LL85-796 0917-0055 o842-W39 $o $o $23o,ooo Propefi Related Public Documents Click here to view Prooerw Related Public Documents Photos Sketches https://qpublic.schneidercorp.com/Application.aspx?ApplD=1O38&LayerlD=22381&PageTypelD=4&Pagelp=${{/fiQ=l$99075260&KeyValue=R050227 43 '911:t24,9:24AM qPublic.net - Garfield County, CO - Property Recod Card: R050227 b 16' WBA 160 sf ONE 240 sf 121 G$t 12i 20t €r{ 6 ?4', TWO 992 sf b 16'1?', 35' u) 4sf WD 553 sf {t, \rEf srlH et\{ 20' Ef\t ooG 400 sf \r 271 4', FOP 221 sf Contact Us Developed by Last Data Up.loaeLS-@!.9:4645.PM The Garfield County Assessor's Office makes every effort to produce the most accurate information possible. No warranties, expressed or implied are provided for the data herein, its ilse or interpretation, Data is subject to constant change and its accuracy and completeness cannot be guaranteed. (-)*lxp^rdg https://qpublic,schneidercorp.com/Application.aspx?ApplD=1O38&LayerlD=2238'l&PageTypelD=4&PagelD=9447&Q=1999075260&KeyValue=R050227 3/3 i GlqPublic.net* Garfield County, Co Account Number Parcel Number Acres Land SqFt TaxArea Mill Levy RO5A227 Physical Address 21873020tOO1 10 OwnerAddress o oo5 60.9540 291 119 COUNTY RD GLENWOODSPRINGS CHAPMAN,TODD D 291 COUNW ROAD 119 GLENWOOD SPRINGS CO 81601 Total Actual Value Overview Legend [-l Parcels Roads Parcel/Account Numbers OwnerName Lakes & Rivers * countyBoundary Line $887,470 Last2Sales Date Price t2/6/2OL9 $5s8,s00 9/26/7994 $230,000 81601 DaIe created:9/t/2O24 Last Data Uploaded:'8/3t/2024 LO:46:,45 PM Deve roned bvf-) Fstxtridrr Item # tM {o60-2GP {060 Gallon Turo Gompartment lnfiltratol@ Poly Tank 1T' 2.I'A@ESSOPENING\ 17' 127' Compliont with CSA ond IAPMO Stondords PVC risers ovoiloble Secondory sofety screen ovoiloble with PVC riser Moximum buriol depth is 48" Minumum buriol depth is 6" Tonk is not roted for vehiculor troffic looding Exterior of monhole cover includes the following worning: "DANGER DO NOT ENTER: POISON GASES,' Digging Specs I n vert Dimensions 2' Long x 7' Wide Top Mew Section 111 SEAM CUP (wPrcAL) UFnNGSTMP CTYHCAL) Net Copocity Weight 1094 gol 320 lbs Mid-Height Seam Section Tank lndudes lids TANKTOP HAIF CONNNUOTJS GASKET 622'.TANK INTERIOR Mew AUGNMENT DOWEL(34) OUTLET TAI{KSOTTOM HAT"F SEAM CUP (84) v.7 EXIERIOR HEIGHT 51.T', I End View lnlet 47" Outlet 44" Length 127" width Heigh 62.2"s4.7"ffirrrr"Silgfi' rnnArctlttHtrc. <- o + o\ \o € o +\ \ o o E E 1 f' Bulkhd Watgr& ,t'.an 6^. -..). ro5OoRd.317 warbwater o{e13e567G4 ;4il6; :FHiH Ferc f/le) s#srzf BHEvlsa'co}1z.1 fnc. o SeMe Webclb: wttw.valbypmetort Ermll : fronUck@Malbyprcetom VALLEY PRtCAgf, Residential Biotube' Effluent Filters Applications Our patented* 4-in. (100-mm) Biotube Effluent Filters, Biotube Jr., Biotube Insert Filters, and Biotube Base Inlet Filters are ideal for residential septic tanks and have a lifetime warranty. They prevent large solids from leaving the tank, dramatically improving wasrewarer qualiry and extending the life of residential drainfields. 4-in.00-Biotube Fiber 4-in. (100-mm) Biotube Jr (4-in. Biotube cartridge auail- able separately as Insert Fiber) f-in. (200-mm) Base Inlet Fiher 4-in. (100-mm) Insert Fiber I 'ltat Orenco's superior effluent fhers resist clogging better than all other brands. Our stan- dard, full-sized 4-in. (100-mm) Biotube Effluent Fiher prouides maxirnum long-term protection in a complere package, with housing. Our 4-in. (100-mm) Biotube Jr., at half the size of our standard rnodel, has more f ltering capacity than the full-sized f lters sold by other manufacturers. For tanks with existing outlet tees, the Biotube Insert Filter is ideal. Andfor lou-profle tanks, therei the Base Inlet Fiber. * Covered by parent numbers 5,492,635 and 4,439,323 To 0rder Call your near€st Orenco Systems@, Inc. distributor. For nearesr distribu- tor, call Orenco at 800-348-9843 or go to www.orenco.com and click on "Distributor Locator. " APS-Ft-1 Rev.3.4 @ tUl0 0renco Systems@, lnc. Standard Features & Benefits . Has 5-10 times more flow area than other brands, so lasts many times longer between clean- ings, increasing homeowner satisfaction . lnstalls in min- utes inside new or existing tanks; extendible tee handle for easy removal . Easyto clean by simply hosing off whenever the tank needs pumping . Removes about two-thirds of sus- pended solids, on average, enending drainfield life . Corrosion-proof construction, to ensure long life . Lifetime warranty 0ptional Features & Benef its . Alarm available, to signal the need for cleaning . Flow modulating discharge orifices available to limit flow rate leaving tank, mitigat- ing surges and increasing retention time . Custom and commercial sizes available Biotube Filtering Process Effluent from the relatively clear zone of the septic tank, between the scum and sludge layers, horizontally enters the Biotube Effluent Filter. Effluent then enters the annular space between the housing and the Biotubes, utilizing the Biotubes'entire surface for filtering. Particles larger than the Biotube's mesh are prevented from leaving the tank. ('funging tfu IYh.y the World Dor lY/attewnkrn *-',*..r € OrencoSystems" lncorporated www.otenco.com Nomenclatures 4-in. Biotube Filter (standard) FT 04 T 0ptions: Blank = no optionsM = flow modulation plate installedA = float bracket attached Cartridge height: 28" and 36" are standard Housinq heioht: 36" and 44" are standard Filter diameter (inches) W = litsType 3034 outlet pipe S = fits Schedule 40 outlet pipe Biotube effluent filter series Blank = 1/S" filtrationP = 1/16" filtration 08 =8' Blank = 1/S" filtrationP = 1/16" liltration Biotube effluent Iilter series Cartridge height (incheg Filter diameter (inches) Blank = l/S" filtrationP = 1/16" filtration lnsert 8-in. Biotube Filter {base intetmodet} FTI oS 22-148 0ptions:A = float bracket FS = 2" outlel orifice FSO = 2" outlet orifice and overllow plate. Base inlet model Cartridge height: 1 4" standard Housing height: 22" standard Filter diameter (inches) - Also avajlable with coupling and sleeve as a "kit": FT-oVERFLOWKIT 4-in. Biotub0 J[. {inctudes cartridge and housing} FT J !!o+ rs 0ptions: Blank = no optionsM = flow modulation plate installedA = float bracket attached Cartridge height (inches) Filter diameter (inches) W = {its Type 3034 outlet teeS = fits Schedule 40 outlet tee Blank = 1/S" filvationP = 1/16" filtration JLrnior series Biolube effluent filter series 4-in. Biotube Filter lnsert (carrridse onty) FT i!04 ls -t- For customized options (e.9., NC indicates North Carolina regions) c_fits fits Type 3034 outlet tee Schedule 40 outlet tee Biotube effluent filter series Distributed By: 4-in. Biotube Effluent Filter Extendible PVC handle Stainless steel set screws Top seal plate Air vents Biotube@ filter cartridge Solid base Filter housing 4-in. Biotube Jr. Tank wall Riser wall Y Double Walled PVG Riser & Lid Options Poly Lid (Static load tested to 5000 lbs). Skid rcsistane surfiace. Available in greeno Highest level of UV Protection induded. lncludes a bam gasketforairtightand watertight applicationso lncludes square drive scfews to discounage unauthorized enty. lnsulation panels achieve R-10 insulation nating 2" ot lnsulation Standard Orenco @ DuraFiber* Access Lids (FLD) Not recommended for vehicular haffic 24" and 30'Diamebrc. Solid, resin{nfused fiberglass conshrction. 20,00G1b breaking stength. Standad green or brorm oolonso Available with or without urethane lid gasket. Available with carbon filtration. 4 stainless steel flathead socket cap scrctfls & hex key wrencfr. lnsulated lids available - 2" or4' Double Walled PVC Riser . Available in 24' and 30" Diamebr. Cut to length. Sold in +l- 2' incremenb. Must be cut between ribs VALLEYn PRECASI, Water & Wastewaler o Slateme o Producils Inc. r SeMce (?191 3956704 2tHOo Rd317 P.O. Bo(@5 Farc fl19) rsf;grn Bsnvlda' @81z-1 Webclb: vurvw.valbyprcetorr Ermll: nonUeef@aalleyprcretorn Ouick4 Plus All-in-One Periscope Ouick4 Plus Standard Chamber Ouick4 Plus All-in-One 12 Endcap Center Structural Columns The Ouick4 Plus Standard Chamber offers maximum strength through its two center structural columns. This chamber can be installed in a 36rinch-wide trench. Like the original line of Ouick4 chambers, it offers advanced contouring capability with its Contour Swivel ConnectionrM which permits 10-degree turns, right and left, lt is also available in four-foot lengths to provide optimal installation flexibility. The Ouick4 Plus All-in-One 12 Endcap, and the Ouick4 Periscope are available with this chamber, providing increased flexibility in system configurations. Quick4 Plus Standard Chamber r Two center structural columns offer increased stability and superior strength . Advanced contouring connections r Latching mechanism allows for quick installation o Four-foot chamber lengths are easy to handle and install r Supports wheel loads of 16,000 lbs/axle with 12" of cover Quick4 Plus All-in-One 12 Endcap e May be used at the end of chamber row for an inlet/ outlet or can be installed mid-trench r Mid-trench connection feature allows construction of chamber rows with center feed, as an alternative to inletting at the ends of chamber rows . Center-feed connection allows for easy installation of serial distribution systems . Pipe connection options include sides, ends or top Quick4 Plus All-in-One Periscope . Allows for raised invert installations r 180" directional inletting . Twelve inch raised invert great for serial applications Vai,pk4,PLUS A\ /l ,/ tr ^ /. ,"ll,l ilr'rii'\ 'f1r i t THE QUICK4@ PLUS STANDARD CHAMBER Quick4 Plus Standard Chamber Side and End Views 48 (EFFECTIVE LENGTH) Quick4 Plus All-in-One 12 Encap Front, Side and End Views 34'. 12" 5.3" INVERT r 11.2" 13' 8'INVERT t l-',r.r" Ouick4 Plus All-in-One Periscope 8" INVERT 33" QUICK4 PLUS ALL-IN.ONE (360"swrvEr ) 6'm !,J 12.7" INVERT OUICK4 PLUS ALL-IN-ONE 12 ENDCAP EU Ouick4 Plus Standard Chamber Specifications Size ftVx Lx H) 34" x53'x 12" (86cm x 135 cm x31 cm)lnvert Height 0.6n, 5,3',, 8,0" 12.7" (1 .5 cm, 8,4 cm, 18,5 cm, 22,6 cm)Effective Length .,,.,.48" (1 22 cm) INFILTRATOR SYSTEMS, INC. STANDARD LIMITED WARRANW (a) The structural integrity of each chamber, end plate, wedge and other accessory manufactured by lnfiltrator ('Units"), when installed and operated in a leachfield of an onsite septic system in accordance with lnfiltrator's inslructions, is warranted to the original purchaser ("Holdea') against defective materials and workmanship for one year from the date that the septic permit is issued for the septic system containing the Units: provided, however. that if a septic permit is not required by applicable law, the warranty period will begin upon the date that install;tion of the septic system commences. To exercise its warranty rights, Holder must notify lnliltrator in writing at its Corporate Headquarters in Old Saybrook, Connecticut within fifteen (15) days of the alleged defect. lnfiltrator will supply replacement Units lor Units determined by lnfiltrator to be covered by this Limited Warranty. lnfiltrator's liability specifically excludes the cost of removal and/or installation of the Units. (b)THE LllvllTED WAFRANTY AND REMEDIES lN SUBPARAGRAPH (a) ARE EXCLUSIVE. THERE AFE NO OTHER WARFANTIES WITH RESPECT TO THE UNITS, INCLUDING NO II\,IPLIED WARRANTIES OF I\4ERCHANTABILIry OR FITNESS FOR A PABTICULAR PUBPOSE (c) This Limited Warranty shall be void if any part of the chamber system is manufactured by anyone other than lnfiltrator. The Limited Warranty does not extend to incidental, consequential, special or indirect damages. lnfiltrator shall not be liable for penalties or liquidated damages, including loss of production and profits, Iabor and materials, overhead costs, or other losses or expenses incurred by the Holder or any third party. Specifically excluded from Limited Warranty coverage are damage to the Units due to ordinary wear and tear, alteration, accident, misuse, abuse or neglect of the Units: the Units being subjected to vehicle traffic or other conditions which are not permitted by the installation insVuctionsi failure to maintain the minimum ground covers set forth in the installation instructions; the placement of improper materials into the system containing the Units; failure of the Units or the septic system due to improper siting or improper sizing, excessive water usage, improper grease disposal, or improper operation; or any other event not caused by lnfiltrator. This Limited Watranly shall be void if the Holder fails to comply with all of the terms set forth in this Limited Warranty. Further, in no event shall lnfiltrator be responsible for any loss or damage to the Holder, the Uniis, or any third pa(y resulting from installation or shipment, or {rom any product liability claims of Holder or any third party. For this Limited Warranty to apply, the Units must be installed in accordance with all site conditions required by state and local codes; all other applicable laws; and lnfiltrator's installation instructions. (d) No repres€ntative of lnliltrator has the aulhority to change or extend this Limited Warranty. No warranly applies to any party other than the oriqinal Holder, The above represents the Standard Limited Waranty offered by lnfiltrator. A limited number of states and counties have different watranty requirements. Any purchaser of Units should contact Infiltratoas Corporate Headquarters in Old Saybrook, Connecticut. prior to such purchase, to obtain a copy of the applicable waranty, and should carefully read that warranty prior to the purchase of Units. 800.221.4436 www. inf iltratorsystems.com ,r IN FILTRATOR' systems inc. 6 Business Park Road r P.O, Box 768 Old Saybrook, CT 06475 860.577.7000 . FAX 860,577.7001 THE QUICK4@ PLUS STANDARD CHAMBER For techn'ical assistance, installation instructions or customer service, call lnfiltrator Systems at 80O.22i.4436 u.S. Patents: 4,759,661; 5,0 1 7,04 1: 5,1 56.488; 5,336,01 7; 5.401,1 r 6: 5.401 ,4s9i s,s I i ,903t 5,7 1 6,1 63; s.s88,778: s.839.944 Canadian Patents: 1,329,959; 2,004,564 Other patents pending. is a registered trademark in Mexico. Contour Swivel Connection is a trademark of Infiltrator Systems lnc. @ 2OO9 lnfihrator Systems lnc. printed in U.S.A.PLUS051 010lSt-2