Loading...
HomeMy WebLinkAboutEngineer's OWTS Design PlanNOTE: _: l LOCATIONS OF ALL COMPONENTS INSTALL DISTFBUTION MAYBE VARIED AS NECESSARY AS i sf K (4 cCl e _F ELI Lf S .L-.11NIMUM DI„TA.,„rS ND.TJ'ES AEET TaOSE REW RED. a 1HP F'✓C , J , ­Ti'. IiHS-A-LA' D' GAL -ON (' 1I II 1UN, - `RECAST TWO (2) CHAMBER SEPTIC TP�1� TANK WITH TEE RISERS ,NO AN -- EFFLUENT FILTER (SEE LE-', I5; l -��� - SECOND,,' DWELL s� v (3 BEDROL-vS ^' risr41 L udu �av CLE�NPUE .,UTSIDE z -HE FCL rill � y � A EJ r.r: c��� l _AC- i PECT C a POET AT EIvD OF EACH .,T.TPAL BOTH ENDS, T'P.� TP�r2Q I(r l� ix I~ I jr oill i EX. RESIDENCE I (3-BEDROOMS) - 1 >l mi I � l N o l l A'PR:;XIMATE I .. LOCATION OF EX l ABSORPTION FIELD I I l l l l i I I EX 'uVELL l I�I I I l it I I I l I I SITE EVALUATION 1. SITE AND SOIL EVALUATIONS WERE PERFORMED BY: DERIC J. WALTER, PE ITV1N DYE, PE BOUNDARIES UNLIMITED INC. GEO QUEST 923 COOPER AVE., STE. 201 PO BOX 1372 GLENWOOD SPRINGS, CO81601 RIFLE, COLOROO81650 970.945.5252 970.318.6784 2. EVALUATION DATE(S): MAY 27, 2024. 3. SETBACK REQUIREMENTS FOR A TREATMENT LEVEL 1 STA TRENCH/BED, UNLINED SAND FILTER OR SEEPAGE PIT (PER TABLE 7-1) AND AN ADWF=450 GRID: 3.A. SPRING, WELL OR POTABLE CISTERN=109 3.B. POTABLE WATER SUPPLY LINE=25' 3.0. STRUCTURE W/ BASEMENT/CRAWL SPACE=20' 3.D. STRUCTURE W/O BASEMENT/C RAWL SPACE=10' 3.E. PROPERTY LINE, PIPE OR LINED IRRIGATION DITCH =10' 3.F. INTERMITTENT IRRIGATION LATERAL, INFILTRATION STRUCTURE=25' 3.G. LAKE, WATER COURSE, IRRIGATION DITCH, STREAM OR WETLAND=50' 3. IT DRY GULCH, CUT BANK OR FILL AREA=25' 3.1. SEPTIC TANK=5' 3.J. RESTRICTIVE LAYER OR GROUNDWATER (VERTICAL): 4' (TREATMENT LEVEL 1, GRAVITY FEED) 3. SETBACK REQUIREMENTS FOR THE SEPTIC TANK SHALL BE (PER TABLE 7-1): 3.A. SPRING, WELL OR POTABLE CISTERN=50' 3.B. POTABLE WATER SUPPLY UNE=1 0' 3.C. STRUCTURE W/ BASEMENT/CRAWL SPACE=5' 3.D. STRUCTURE W/O BASEMENT/CRAWL SPACE=5' 3.E, PROPERTY LINE, PIPE OR LINED IRRIGATION DITCH=10' 3.F. INTERMITTENT IRRIGATION LATERAL, INFILTRATION STRUCTURE=10' 3.G. LAKE WATER COURSE. IRRIGATION DITCH STREAM OR WETLAND=50' 3.H. DRY GULCH CUT BANK OR FILL ARE A=10' 3.1. STA TRENCH/BED, UNLINED SAND FILTER OR SEEPAGE PIT=5' SOIL EVALUATION 1. SOIL WAS CLASSIFIED BY THE GEOTECHNICAL ENGINEER (GEO QUEST (PROJECT #24-162, AUGUST 11, 2024) AS USDA CLAY LOAM; TYPE 3A; WITH AN LTAR OF 0.30 GPD/SF. F >12" SURFACE \ \ \ \ / SAND, SILT, CLAY, ,/ TAN MOIST Site & Soils Evaluation Scale: N.T.S. GENERAL ABSORPTION AREA NOTES 1. INSTALL CHAMBER UNITS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 2. NON -PRESSURIZED ABSORPTION AREAS SHALL NOT EXCEED 100-FEET IN LENGTH, SHALL PARALLEL THE TOPOGRAPHY AND SHALL BE INSTALLED IN A RECTANGULAR/LINEAR PATTERN WHENEVER POSSIBLE, 3. THE BOTTOM OF THE ABSORPTION AREA SHALL BE LEVEL AND THE BOTTOM AND SIDEWALLS MUST BE RAKED TO REMOVE ANY SOIL SMEARS INCURRED DURING THE EXCAVATION. FAILURE TO DO SO MAY REQUIRE THE CONTRACTOR TO REPLACE THE ABSORPTION FIELD AT HIS/HER OWN EXPENSE. 4. DRAINAGE SWALES ARE TO BE PROVIDED ABOVE AND AROUND THE ABSORPTION AREA, AS NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING ABSORPTION AREA. BOX & COVER - LID COLOR PURPLE OR GREEN - LABEL "SEWER" FILL OVER THE CHAMBERS WITH UNCOMPACTED WELL GRADED LOCAL SOILS, \ 5 GRAVELLESS CHAMBER SYSTEM: --`z INFILTRATOR QUICK 4, ADVANCED DRAINAGE SYSTEMS ARC (STANDARD), OR ENGINEER APPROVED EQUAL. OPTIONAL: COVER THE CHAMBERS WITH A NON -WOVEN FILTER/LANDSCAPE FABRIC TO LIMIT THE POTENTIAL FOR FINE MIGRATION INTO THE SYSTEM THE INFLOW PIPE SHALL ENTER THE UPPER PORT OF THE END CAP 5. NO EXCAVATION OF THE ABSORPTION AREA IS TO BE DONE DURING WET WEATHER AND USE OF RUBBER TIRE VEHICLES OVER THE ABSORPTION AREA IS STRICTLY PROHIBITED. 6. UNSUITABLE MATERIAL EXISTING WITHIN THE ABSORPTION AREA SHALL BE EXCAVATED AND BACKFILL SHALL CONSIST OF IMPORTED LOAMY SAND OR SANDY GRAVEL. THE ENGINEER SHALL BE CONTACTED IF BEDROCK OR GROUNDWATER IS ENCOUNTERED IN THE EXCAVATION. 7. TOPSOIL COVER MAY BE VARIED (1-FOOT MINIMUM, 2-FOOT MAXIMUM) TO ALLOW FOR LANDSCAPING. 8. WHEN MULTIPLE LATERALS OR BEDS ARE USED, LATERALS OR BEDS SHALL BE SEPARATED BY 6-FEET MIN, OF UNDISTURBED SOILS, STANDARD INSPECTION PORT, TYP. (4"0 PVC SOLID PIPE CUT TO FIT. LOCATE PER PLAN VIEW. ATTACH A REMOVABLE CAP OR THREADED CLEANOUT ASSEMBLY. COVER WITH 6" OF TOPSOIL I AND REVEGETATE 4"0 PVC PIPE ':. 4"0 COUPLING (UNION). USE A _ HOLE SAW TO CUT OUT THE CIRCLE IN THE UNIT, 4"0 PERFORATED PVC PIPE. ..;'; \/, ,EXTEND PIPE TO REST ON OTTOM OF THE BED BOTTOM TO BE LEVEL AND FLAT OVER ENTIRE AREA TO WITHIN Dl'±. (TYP.). IF NECESSARYTO ACHIEVE THIS SURFACE, IMPORT CONCRETE SAND TO USE AS LEVELING MATERIAL. REMOVE ANY ENCOUNTERED BOULDERS AND BACKFILL WITH LOAMY SAND OR SANDY GRAVELS. DO NOT USE COMPACTED MATERIALS, Gravelless Chamber Absorption Trench Scale: N.T.S. MAINTENANCE NOTES 1. TO ENCOURAGE THE HEALTH AND LONGEVITY OF THE OWTS SYSTEM, THE OWNER SHALL CONSIDER THE FOLLOWING: .A. U F S DOWN THE DRAIN THE BETTER YOUR SYSTEM 1 MINIMIZE THE AMOUNT 0 WATER THAT GOES , WILL WORK. 1.8. MINIMIZE SOLIDS GOING DOWN THE DRAIN. 1.C. ELIMINATE GARBAGE DISPOSALS OR KEEP THE USE OF GARBAGE DISPOSALS TO A MINIMUM. 1.D. MINIMIZE GREASE AND OILS THAT GO DOWN THE DRAIN. 1.E. USE LINT FILTERS ON LAUNDRY MACHINE DRAINS. 1.F. KEEP SAND AND DIRT OUT OF THE BUILDING DRAIN. 1.G. AVOID FLUSHING SANITARY NAPKINS OR PAPER PRODUCTS OTHER THAN TOILET PAPER. 1.H. DO NOT USE LYE -BASED DRAIN UNCLOGGER CHEMICALS SUCH AS DRAINO, OVEN -OFF, OR OTHER STRONG CLEANING AGENTS. 1.1. DO NOT PUT ANY "ROOT DETERRENTS" DOWN THE DRAIN. 1.J. DO NOT POUR PAINT THINNER, PESTICIDES, PAINTS OR PHOTO LAB CHEMICALS DOWN THE DRAIN 1.K. MINIMIZE USE OF CHLORINE BLEACH AND TOILET ADDITIVES. 2. THE OWNER SHALL CONTRACT WITH A SEPTIC TANK INSPECTOR TO INSPECT THE TANK ANNUALLY FOR GREASE AND SEDIMENT ACCUMULATION. THE INSPECTOR SHALL REMOVED AND PROPERLY DISPOSED OF ACCUMULATED GREASE AND SEDIMENT AS NEEDED TO ENSURE PROPER FUNCTION OF THE SYSTEM. ATTACH REMOVABLE CAP OR THREADED CLEANOUT ASSEMBLY. 1 INSTALL MARKER IF CAP IS TO I FINISH GRADE BE BURIED, 4"0 PVC TWO-WAY CLEANOUTTEE 0 4"0 PVC RISER �- 4"0 SEWER LINE Two Way Cleanout Scale, N.T.S. 11 Concrete Distribution Box aoxsc (al Inlet, 7 Outlets) & Riser Top View 28" 15" i Section View End View 28" 15" - 25" - 12" -- 14" i ®®®a ♦� 14" 5.". 7• 1 i Down Baffle REQUIRED REQUIRED _ 28" y ROTO-FLOW r -OR - . POLYLOCK EQUALIZER a a , . ; : 4 p� a //�1� R 4 � "W NOTCH• WEIR SHAPE IS -;ELF ,♦ .. i a II " _ a 20 /\ SELF LEVELING . NOT TO SCALE RIBS PROVIDE FRICTION -- Lid View FIT FOR ALL C PIPE ID NOTE: THIS MANUFACTURER'S CUT SHEET IS FOR REFERENCE NOT TO SCALE PURPOSES ONLY, OTHER MANUFACTURERS SUPPLYING COMPARABLE PRODUCTS MAY BE USED. • 6000 PSI Concrete Riser Section • 7 Outlet equal flow Access to Grade Required • Slide -in Baffle. 4" Pipe penetration ports ---- 28" • Connectors cast into the box - 15" - • 12" Riser available 12" , ♦ d 2" . j 1a 1 Wel9 �ht . I -- 12^ -- D-Box with Baffle - 200 Ibs Side View End View D-Box Lid - 75 Ibs D-Box Riser -140 Ibs 'rALLEY Do PRECAST, Inc. L__ Buena Vista, Colorado Phone: 719-395-6764 www.valleyprecastcom � •On f ! -Kr M•I. 132 Rusty Spur Trail County of Garfield, State of Colorado Parcel No: 2127-332-00-373 �-- fa r7-7v T I J - r nT0»nl9i "`bl nzw,xns Slit,_ 2" ' »-.-�T _ fRii 1, r tiJ' Vicinity Map SYSTEM DESIGN & CONSTRUCTION NOTES: 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH CDPHE REGULATION 43 ONSITE WASTEWATER TREATMENT SYSTEM (OWTS) REGULATION, MOST CURRENT EDITION AND LOCAL AGENCY REQUIREMENTS WHICH MAY OR MAY NOT SPECIFICALLY BE NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR KNOWING AND CONFORMING TO SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS. THIS DRAWING DOES NOT CONSTITUTE AN OWTS PERMIT. A PERMIT MUST BE OBTAINED FROM APPROPRIATE LOCAL AGENCY. THE CONTRACTOR MUST CONTACT THE LOCAL AGENCY HEALTH DEPARTMENT AND THE PROJECT ENGINEER FOR INSPECTIONS OF THE CONSTRUCTED SYSTEM BEFORE BACKFILL. A REQUEST FOR INSPECTION BY THE PROJECT ENGINEER AND THE COUNTY ENVIRONMENTAL HEALTH OFFICER MUST BE MADE AT LEAST 72-HOURS PRIOR TO THE DESIRED TIME OF BACKFILLING. 2. DEMAND CALCULATIONS (SEC.43.6.A.2.h) 2.A. THREE (3) BEDROOM RESIDENCE USING TREATMENT LEVEL 1 (TLI). 2.B. AVERAGE DAILY WASTEWATER FLOW (ADWF) AND ORGANIC LOAD RATE (BODs): 2.6.1. SINGLE FAMILY DWELLING: 75 gpdc & 0.20 BOD5Ibs/day 2.B.2. ADWF: 2.B.2.1. RESIDENCE = 75 gpd * (3 BEDROOMS * 2 PERSONS/BEDROOM) = 450 gpd 2.B.3. B005 = 0,20 Ibs/day * 7 PERSONS =1.40 Ibs/day BOD5 mg/L = BODS*1,OOQ000 = 1.40lbs/daV*1,000,000 = 319.74 mg/L ADWF*8.34 450 gpd*8.34 2.8A. CBOD5 = BOD5 * 0.85 = 272 mg/L 3. SEPTIC TANK (SEC.43.9.8.2.a): 3.A. INSTALL A 1,000-GALLON (MINIMUM) TWO COMPARTMENT SEPTIC TANK (TABLE 9-1). 3.B. THE TANK IS NOT SUBJECT To BUOYANCY. 4. ABSORPTION AREA CALCULATIONS: 4.A. THE ABSORPTION AREA SLOPES GENTLY. 4.B. LONG TERM ACCEPTANCE RATE (LTAR) FOR TREATMENT LEVEL 1 (TL1) OF 0.30 gpd/SF (SEE SITE & SOILS EVALUATION NOTES/DETAIL). 4.C. MINIMUM SOIL TREATMENT AREA, A: A = ADWF = 450 = 1,500 S.F. LTAR 0.30gpd/S.F. 4.D. SIZE ADJUSTMENT FACTORS: GRAVITY TRENCH = 1. 0; CHAMBERS = 0.7 (TABLE 10-1 A), 4. CA A,adj = 1,500 SF * 1.0* 0.7 = 1,050 SF 4.E. GRAVELLESS CHAMBER BED SYSTEM: 4.E.1. INFILTRATOR QUICK4: 1,050 SF / 12 SF/UNIT = 88 UNITS. INSTALL 88 UNITS IN FOUR (4) TRENCHES (22 UNITS PER TRENCH). 4.E.2. ADS ARC: 1,050 SF / 15 SRUNIT = 70 UNITS. INSTALL 72 UNITS IN FOUR (4) TRENCHES (18 UNITS PER TRENCH). 5. THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS (EXCLUDING SMALL UNDER -SINK) OR WATER SOFTENERS AND/OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM. 6. CLEAN OUTS ARE REQUIRED AT THE HOUSE AND AT ALL BENDS AND AT LEAST EVERY 100-FEET BETWEEN THE HOUSE AND THE SEPTIC TANK. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL WATER TIGHT COMPONENTS THROUGHOUT THE SYSTEM TO PREVENT INFILTRATION. 8. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS PORTS TO FINAL GRADE. PORTS SHALL BE MARKED IF CAPS ARE TO BE BURIED. 9. INSTALL 3-INCHES OF BLUEBOARD INSULATION, 3-FEET WIDE, OVER SEWER AND EFFLUENT PIPE WHEREVER DEPTH IS LESS THAN 3-FEET. UNDER NO CIRCUMSTANCES SHALL COVER BE LESS THAN 2-FEET. 10. SITE PLAN INFORMATION FROM OTHERS. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED. Item 0 1000 Gallon Top Seam - 2CP 1000T-2CP DESIGN NOTES • Design per performance test per ASTM C1227 • Tap surface area 46.25 fix • fc O 2a days; concrete = 6,000 PSI Min. installation: • Tank to be set on 5" min. sand bed or pea gravel • Tank to be backfilled uniformly on oil sides In lifts less than 24" and mechanically compacted • Excavated material may be used for backfill, provided large stones ore removed • Excavation should be dewatered and tank filled with water prior to being put in service for Installation with water table less than 2' below grade • Meets C1644-06 for resilient connectors • Inlet and Outlet identified above pipe • Delivered complete with internal piping • 4' Maximum bury depth ALLOWABLE BURY (Based on Water Table) WATER TABLE ALLOWABLE EARTH FILL 0' - 0" 2' - 0" V a" 3' - a" 2' - 0" 3' - 0' 3' - 0' 4' - 0' 6" ORY 4' - Fleftle 4- Top View t3i Grade 1im 7-7 71 "'TAEIIJ:, RTRO NO Section View NOTE: THIS MANUFACTURER'S CUT SHEET IS FOR REFERENCE PURPOSES ONLY OTHER MANUFACTURERS SUPPLYING COMPARABLE PRODUCTS MAY BE USED, -. - -- -. -. _ Net Capacity Net Weight Digging Specs Invert , Dimensions III 11 Long x 7' Wide �lnlet {Outlet Length Width Height Inlet Side Outlet Total Lid Tank Total 56" below inlet 56 53" 111' 60" 68" 687 gal 323 gal 1010 gal 2620 Ibs 9380 Ibs 12000 Ibs I "� I _ I Ir v�L� P AS, Inc. � Buena Vista, Colorado Phone: 719-396.67764 Fax: 719-395-3727 Websiie: www.vaileyprecestoom Email: frorMesk@valleypnxwL om Civil Engineering Surveying & Beyond �rf ed Inc• 923 Cooper Avenue Suite 201 Glenwood Springs, CO 81601 telex 970.945.5252 fax: 970.384.2833 Engineer or Surveyor Seal �P o � \� jON V �qQ 08/19/24 F7;. 37110 5 Client Information: David Mul/enex 132 Rusty Spur Trail Riiis' C0 81650 970.368.2065 NORTH 0 30' 60 Scale: 1" = 39 Know what's below. Call before you dig. y 0 � L Q cc:^ � COD Z � � L W � � Cc Ct ell N as C Q m 0 d 0 o Z +� N a'i R L6 rC ^ ad 01 PROJECT NO Sheet 24025 FILE NAME: 24025-V-tdpo.&I Designer: a1w C. /Dreher arw Date: 08119124