Loading...
HomeMy WebLinkAboutBlower Door Test9/17/2024 Air Leakage Test Report In compliance with ASTM E-779 (2019) Building Address:32 River Ridge Dr. Glenwood Springs, Garfield CO USA 81601 Performed for: Performed by: Amanda Poindexter Test date:2024-09-16 Associated Test file: ASTM2019 2024-09-16 1209 Report Number: Unique Property ID Number: Dexter Diagnostics 9/17/2024 Summary 32 River Ridge Dr. FanTestic version: 5.15.86 licensed to: Full Circle Construction Test date: 2024-09-16 By: Amanda Poindexter Customer: Building Lot Number: Building address: 32 River Ridge Dr. Glenwood Springs, Garfield CO USA 81601 Building and Test Information Test file name:ASTM2019 2024-09-16 1209 Building volume [cu ft]:34,942 Envelope Area [sq ft]:0 Floor Area [sq ft]:2,130 Building Height (from ground to top) [ft]:15 Altitude [ft]:5,966 Results CFM at 50 Pa:1545.0 Leakage Area (EqLA) [sq in]:143.7 Leakage Area (EfLA) [sq in]:71.92 Air Changes per hour ACH50:2.65 Dexter Diagnostics