HomeMy WebLinkAboutPermit- Renewed
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: Lot 2 County Rd 259 Rifle, CO
Parcel No.: _212733101002
Owner Name: Jose and Laura Gonzolez Owner Phone: (970)-309-4348
Designed By: Cronk Construction, Inc. Designer Phone: (970) 640-5029
Number of Bedrooms: 8 Minimum Tank Capacity: 1,500-gallon Minimum Absorption: 1470 ft2
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT-7853_Reneewed______________________________
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date _10/04/2024____________________ Expiration Date_10/04/2025_________________
Permit Conditions:
Permit Conditions: This OWTS Permit is approved on the condition of compliance with the design as
submitted by Cronk Construction, Inc. dated Sept 25, 2022. Changes must be approved by Garfield
County Public Health and the designer prior to construction.
The new OWTS will serve a new 5-bedroom residence and a 3-bedroom ADU. The system will consist
of a new, two-compartment minimum 1,500-gallon septic tank set level with access to grade and an
effluent filter in the outlet tee of the tank for the main residence. A new, two-compartment
minimum 1,250-gallon septic tank set level with access to grade and an effluent filter in the outlet
tee of the tank will serve the ADU. Effluent will gravity flow to a distribution box set level with access
to grade that will distribute effluent to 1,470 ft2 of STA. The new STA will consist of 6 gravelless
trenches. Each row will consist of 21 Quick4 chambers, for a total of 126 Quick4 chambers.
Inspection ports are to be installed at the terminal ends of each trench. Maintain all setbacks and
elevations as designed.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction, and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection,
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as-built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
10/04/2024
Issued By: Garfield County Environmental Health
Department
Date