Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Manual J Report
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2024-Oct-03 17:52:25 Right-Suite® Universal 2024 24.0.02 RSU16998 Page 1 ... Grosbeak Place, Glenwood Springs, CO 81601.rup Calc = MJ8 Front Door faces: N 52 Grosbeak PlaceJob:Load Short Form October 2nd 2024Date:AC 1 Main Living Kenneth D. PuzinasBy: 52 Grosbeak PlacePlan:WebREPS, LLC 1880 82nd Avenue Suite # 203, Vero Beach, FL 32966 Phone: 800-810-3280 Fax: 888-971-2999 Email: manualj@webrepsusa.com Web: www.acductdesign.com License: CAC054709 Project Information Kenneth Garrett, Junior's LTDFor: 6372 S Benton Way, Littleton, CO 80123 Phone: 303 359 9671 Fax: N/A Email: kennygarr@gmail.com Design Information InfiltrationClgHtg SimplifiedMethod935Outside db (°F) TightConstruction quality7570Inside db (°F) 0Fireplaces1865Design TD (°F) H-Daily range 5050Inside humidity (%) -4461Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Goodman Mfg. Make Goodman Mfg. Trade GOODMAN Trade GOODMAN Model GM9C960804CNA Cond GSXN404210A AHRI ref 207349261 Coil CAPF4961N6D AHRI ref 209322303 Efficiency 96.1 AFUE Efficiency 11.7 EER2,14.5 SEER2 Heating input Btuh80000 Sensible cooling Btuh29250 Heating output Btuh77000 Latent cooling Btuh9750 Temperature rise °F67 Total cooling Btuh39000 Actual air flow cfm1300 Actual air flow cfm1300 Air flow factor cfm/Btuh0.040 Air flow factor cfm/Btuh0.057 Static pressure in H2O0.60 Static pressure in H2O0.60 Space thermostat Load sensible heat ratio 0.75 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) LIVING AREA 655 7142 5916 288 337 KITCHEN 498 691 2408 28 137 FOYER 200 2958 1139 119 65 BATH 5 45 61 223 2 13 CL 4 18 0 0 0 0 LAUNDRY 177 2686 1582 108 90 BEDROOM 4 175 1260 1387 51 79 WINE CELLAR 51 85 845 3 48 BUTLER PANTRY 58 78 924 3 53 DINING AREA 217 352 1692 14 96 NOOK 35 0 0 0 0 BATH 4 76 691 165 28 9 BATH 3 74 131 272 5 15 BEDROOM 3 171 1355 1448 55 82 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2024-Oct-03 17:52:25 Right-Suite® Universal 2024 24.0.02 RSU16998 Page 2 ... Grosbeak Place, Glenwood Springs, CO 81601.rup Calc = MJ8 Front Door faces: N WIC 2 47 0 0 0 0 BATH 2 75 1266 269 51 15 CL 3 23 0 0 0 0 HALLWAY 140 0 0 0 0 BEDROOM 2 196 2483 1936 100 110 COAT CL 20 0 0 0 0 MAIN CRAWL SP 2990 10980 2624 443 149 ALCO 34 0 0 0 0 AC 1 Main Living 5973 32218 22829 1300 1300 Other equip loads 24154 4867 Equip. @ 1.00 RSM 27696 Latent cooling 9129 TOTALS 5973 56372 36826 1300 1300 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2024-Oct-03 17:52:25 Right-Suite® Universal 2024 24.0.02 RSU16998 Page 3 ... Grosbeak Place, Glenwood Springs, CO 81601.rup Calc = MJ8 Front Door faces: N 52 Grosbeak PlaceJob:Load Short Form October 2nd 2024Date:AC 2 Master Suite Kenneth D. PuzinasBy: 52 Grosbeak PlacePlan:WebREPS, LLC 1880 82nd Avenue Suite # 203, Vero Beach, FL 32966 Phone: 800-810-3280 Fax: 888-971-2999 Email: manualj@webrepsusa.com Web: www.acductdesign.com License: CAC054709 Project Information Kenneth Garrett, Junior's LTDFor: 6372 S Benton Way, Littleton, CO 80123 Phone: 303 359 9671 Fax: N/A Email: kennygarr@gmail.com Design Information InfiltrationClgHtg SimplifiedMethod935Outside db (°F) TightConstruction quality7570Inside db (°F) 0Fireplaces1865Design TD (°F) H-Daily range 5050Inside humidity (%) -4461Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Goodman Mfg. Make Goodman Mfg. Trade GOODMAN Trade GOODMAN Model GM9C960603BNA Cond GSXN3N2410A AHRI ref 207349259 Coil CAPFA3022N6B+GM9C960603BNA+TXV AHRI ref 210545587 Efficiency 96.1 AFUE Efficiency 11.2 EER2, 14 SEER2 Heating input Btuh60000 Sensible cooling Btuh16950 Heating output Btuh58000 Latent cooling Btuh5650 Temperature rise °F87 Total cooling Btuh22600 Actual air flow cfm753 Actual air flow cfm753 Air flow factor cfm/Btuh0.025 Air flow factor cfm/Btuh0.061 Static pressure in H2O0.60 Static pressure in H2O0.60 Space thermostat Load sensible heat ratio 0.75 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) PRIMARY BEDROOM 344 5069 4087 129 250 PWIC 93 126 382 3 23 P WC 28 38 180 1 11 WIC / DRESSING 180 2033 1390 52 85 PANTRY 92 138 250 4 15 ST WIC 29 0 0 0 0 STUDY OFFICE 244 4318 2832 110 173 PRIMARY BATH 265 2639 1998 67 122 DEEP CRAWL SP 344 4548 317 116 19 MASTER CRAWL SP 922 10704 892 272 54 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2024-Oct-03 17:52:25 Right-Suite® Universal 2024 24.0.02 RSU16998 Page 4 ... Grosbeak Place, Glenwood Springs, CO 81601.rup Calc = MJ8 Front Door faces: N AC 2 Master Suite 2541 29613 12328 753 753 Other equip loads 11738 3136 Equip. @ 1.00 RSM 15464 Latent cooling 5021 TOTALS 2541 41351 20485 753 753 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2024-Oct-03 17:52:25 Right-Suite® Universal 2024 24.0.02 RSU16998 Page 1 ... Grosbeak Place, Glenwood Springs, CO 81601.rup Calc = MJ8 Front Door faces: N 52 Grosbeak PlaceJob:Project Summary October 2nd 2024Date:AC 1 Main Living Kenneth D. PuzinasBy: 52 Grosbeak PlacePlan:WebREPS, LLC 1880 82nd Avenue Suite # 203, Vero Beach, FL 32966 Phone: 800-810-3280 Fax: 888-971-2999 Email: manualj@webrepsusa.com Web: www.acductdesign.com License: CAC054709 Project Information Kenneth Garrett, Junior's LTDFor:6372 S Benton Way, Littleton, CO 80123 Phone: 303 359 9671 Fax: N/AEmail: kennygarr@gmail.com 52 Grosbeak Place, Glenwood Springs, CO 81601Notes: Design Information Rifle Garfield County AP, CO, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F5 Outside db °F93Inside db °F70 Inside db °F75 Design TD °F65 Design TD °F18Daily range H Relative humidity %50Ventilation Method ASHRAE 62.2-2019 Moisture difference gr/lb-44 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh32218 Structure Btuh22829 Ducts Btuh0 Ducts Btuh0Central vent (202 cfm) 11554 Btuh Central vent (202 cfm) Btuh3161 Outside air Outside airHumidification Btuh12600 Blower Btuh1707 Piping Btuh0Equipment load Btuh56372 Use manufacturer's data y Rate/swing multiplier 1.00InfiltrationEquipment sensible load Btuh27696 Method Latent Cooling Equipment Load SizingSimplified Construction quality Tight0Fireplaces Structure Btuh14032 Ducts Btuh0Central vent (202 cfm) Btuh-4902 CoolingHeating Outside air59735973Area (ft²) Equipment latent load Btuh9129 4161141611Volume (ft³)Air changes/hour 0.040.07 Equipment Total Load (Sen+Lat)Btuh36826 Equiv. AVF (cfm) 2551 Req. total capacity at 0.75 SHR ton3.1 Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg. Make Goodman Mfg.Trade GOODMAN Trade GOODMAN Model GM9C960804CNA Cond GSXN404210AAHRI ref 207349261 Coil CAPF4961N6D AHRI ref 209322303Efficiency 96.1 AFUE Efficiency 11.7 EER2,14.5 SEER2 Heating input Btuh80000 Sensible cooling Btuh29250Heating output Btuh77000 Latent cooling Btuh9750 Temperature rise °F67 Total cooling Btuh39000Actual air flow cfm1300 Actual air flow cfm1300 Air flow factor cfm/Btuh0.040 Air flow factor cfm/Btuh0.057Static pressure in H2O0.60 Static pressure in H2O0.60 Space thermostat Load sensible heat ratio 0.75 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2024-Oct-03 17:52:25 Right-Suite® Universal 2024 24.0.02 RSU16998 Page 2 ... Grosbeak Place, Glenwood Springs, CO 81601.rup Calc = MJ8 Front Door faces: N 52 Grosbeak PlaceJob:Project Summary October 2nd 2024Date:AC 2 Master Suite Kenneth D. PuzinasBy: 52 Grosbeak PlacePlan:WebREPS, LLC 1880 82nd Avenue Suite # 203, Vero Beach, FL 32966 Phone: 800-810-3280 Fax: 888-971-2999 Email: manualj@webrepsusa.com Web: www.acductdesign.com License: CAC054709 Project Information Kenneth Garrett, Junior's LTDFor:6372 S Benton Way, Littleton, CO 80123 Phone: 303 359 9671 Fax: N/AEmail: kennygarr@gmail.com 52 Grosbeak Place, Glenwood Springs, CO 81601Notes: Design Information Rifle Garfield County AP, CO, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F5 Outside db °F93Inside db °F70 Inside db °F75 Design TD °F65 Design TD °F18Daily range H Relative humidity %50Ventilation Method ASHRAE 62.2-2019 Moisture difference gr/lb-44 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh29613 Structure Btuh12328 Ducts Btuh0 Ducts Btuh0Central vent (91 cfm) 5225 Btuh Central vent (91 cfm) Btuh1430 Outside air Outside airHumidification Btuh6512 Blower Btuh1707 Piping Btuh0Equipment load Btuh41351 Use manufacturer's data y Rate/swing multiplier 1.00InfiltrationEquipment sensible load Btuh15464 Method Latent Cooling Equipment Load SizingSimplified Construction quality Tight0Fireplaces Structure Btuh7238 Ducts Btuh0Central vent (91 cfm) Btuh-2217 CoolingHeating Outside air25412541Area (ft²) Equipment latent load Btuh5021 1737817378Volume (ft³)Air changes/hour 0.080.16 Equipment Total Load (Sen+Lat)Btuh20485 Equiv. AVF (cfm) 2447 Req. total capacity at 0.75 SHR ton1.7 Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg. Make Goodman Mfg.Trade GOODMAN Trade GOODMAN Model GM9C960603BNA Cond GSXN3N2410AAHRI ref 207349259 Coil CAPFA3022N6B+GM9C960603BNA+TXV AHRI ref 210545587Efficiency 96.1 AFUE Efficiency 11.2 EER2, 14 SEER2 Heating input Btuh60000 Sensible cooling Btuh16950Heating output Btuh58000 Latent cooling Btuh5650 Temperature rise °F87 Total cooling Btuh22600Actual air flow cfm753 Actual air flow cfm753 Air flow factor cfm/Btuh0.025 Air flow factor cfm/Btuh0.061Static pressure in H2O0.60 Static pressure in H2O0.60 Space thermostat Load sensible heat ratio 0.75 Job #: 52 Grosbeak Place Performed by Kenneth D. Puzinas for: Kenneth Garrett 6372 S Benton Way Littleton, CO 80123 Phone: 303 359 9671 Fax: N/A kennygarr@gmail.com WebREPS, LLC 1880 82nd Avenue Suite # 203 Vero Beach, FL 32966 Phone: 800-810-3280 Fax: 888-971-2999 License: CAC... www.acductdesign.com manualj@webrepsusa.com Scale: 1 : 172 Page 1 Right-Suite® Universal 2024 24.0.02 RSU16998 2024-Oct-03 17:53:25 ..., Glenwood Springs, CO 81601.rup N Crawl Space DEEP CRAWL SP MAIN CRAWL SP MASTER CRAWL SP 8 x 8 111 c fm 8 x 8 111 cfm 8 x 8 111 c fm 8 x 8 136 cfm 6 x 6 116 cfm 10 x 6 136 cfm 4 " 7 " 6 "6 " 7 " 6 " 6 " 5 " 4 " 10 x 6 12 x 10 4 " 6 " 14 x 12 10 x 10 8 x 8 6 "6 " 16 x 18 12 x 16 8 x 8 111 c fm 6 " 4 " 6 " 5 " 8 x 10 4 " 5 " 5 " 4 "4 " 6 " 4 " 6 " 10 x 10 7 " 6 " 6 " 6 " 6 " 12 x 14 10 x 10 4 " 6 x 8 8 x 10 6 x 10 6 " 8 x 10 6 x 10 6 " Job #: 52 Grosbeak Place Performed by Kenneth D. Puzinas for: Kenneth Garrett 6372 S Benton Way Littleton, CO 80123 Phone: 303 359 9671 Fax: N/A kennygarr@gmail.com WebREPS, LLC 1880 82nd Avenue Suite # 203 Vero Beach, FL 32966 Phone: 800-810-3280 Fax: 888-971-2999 License: CAC... www.acductdesign.com manualj@webrepsusa.com Scale: 1 : 172 Page 2 Right-Suite® Universal 2024 24.0.02 RSU16998 2024-Oct-03 17:53:26 ..., Glenwood Springs, CO 81601.rup N 1st Floor WIC / DRESSING P WC PWIC PRIMARY BATH PRIMARY BEDROOM LIVING AREA PANTR Y ST WIC STUDY OFFICE KITCHEN ALCO FOYER BATH 5 CL 4 LAUNDRY BEDROOM 4 WINE CELLAR BUTLER PANTRY DINING AREA NOOKBATH 4 BATH 3 BEDROOM 3 WIC 2 BATH 2 CL 3 HALLWAY BEDROOM 2 GARAGE DN COAT CL 10 x 6 125 cfm 8 x 4 119 cfm 10 x 6 137 cfm 8 x 4 13 cfm 8 x 4 28 cfm 8 x 4 15 cfm 10 x 6 82 cfm 8 x 4 51 cfm 8 x 4 79 cfm 10 x 6 173 cfm 8 x 4 23 cfm 8 x 4 15 cfm 8 x 4 108 cfm 8 x 4 48 cfm 10 x 6 110 cfm 8 x 4 11 cfm 20 x 12 753 cfm 10 x 6 125 cfm 8 x 4 53 cfm 10 x 6 96 cfm 20 x 20 1300 cfm 10 x 4 122 cfm 10 x 6 85 cfm 10 x 6 112 cfm10 x 6 112 cfm 10 x 6 112 cfm 2024-Oct-03 17:52:25 Right-Suite® Universal 2024 24.0.02 RSU16998 Page 1 ... Grosbeak Place, Glenwood Springs, CO 81601.rup Calc = MJ8 Front Door faces: N 52 Grosbeak PlaceJob:Duct System Summary October 2nd 2024Date:AC 1 Main Living Kenneth D. PuzinasBy: 52 Grosbeak PlacePlan:WebREPS, LLC 1880 82nd Avenue Suite # 203, Vero Beach, FL 32966 Phone: 800-810-3280 Fax: 888-971-2999 Email: manualj@webrepsusa.com Web: www.acductdesign.com License: CAC054709 Project Information Kenneth Garrett, Junior's LTDFor: 6372 S Benton Way, Littleton, CO 80123 Phone: 303 359 9671 Fax: N/A Email: kennygarr@gmail.com CoolingHeating External static pressure in H2O0.60in H2O0.60 Pressure losses in H2O0.24in H2O0.24 Available static pressure in H2O0.36in H2O0.36 Supply / return available pressure 0.252 / 0.108 in H2O in H2O0.252 / 0.108 Lowest friction rate in/100ft0.074in/100ft0.074 Actual air flow cfm1300cfm1300 Total effective length (TEL) ft489 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st6A230.062.0ShMt0x04.00.08615511266hBATH 2 st5210.065.8ShMt0x04.00.092155272cBATH 3 st5215.077.3ShMt0x04.00.086928691hBATH 4 st5B240.088.3ShMt0x04.00.077132223cBATH 5 st6200.056.0ShMt0x06.00.0991101001936cBEDROOM 2 st6A220.064.0ShMt0x05.00.08982551448cBEDROOM 3 st5200.085.3ShMt0x05.00.08879511387cBEDROOM 4 st5B260.082.5ShMt0x04.00.074533924cBUTLER PANTRY st5A220.079.0ShMt0x05.00.08496141692cDINING AREA st4C195.068.0ShMt0x06.00.096651192958hFOYER st4B185.044.8ShMt0x07.00.110137282408cKITCHEN st5C240.098.0ShMt0x06.00.075901082686hLAUNDRY st3125.014.8ShMt0x06.00.181112961972cLIVING AREA st3115.031.3ShMt0x06.00.173112961972cLIVING AREA-A st4A155.020.3ShMt0x06.00.144112961972cLIVING AREA-B st6A235.053.0ShMt0x06.00.088371112745hMAIN CRAWL SP st4135.027.3ShMt0x06.00.156371112745hMAIN CRAWL SP-A st5B250.078.0ShMt0x06.00.077371112745hMAIN CRAWL SP-B st4B175.050.5ShMt0x06.00.112371112745hMAIN CRAWL SP-C st5B255.073.8ShMt0x04.00.077483845cWINE CELLAR 2024-Oct-03 17:52:25 Right-Suite® Universal 2024 24.0.02 RSU16998 Page 2 ... Grosbeak Place, Glenwood Springs, CO 81601.rup Calc = MJ8 Front Door faces: N Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st5 Peak AVF 326 441 0.074 635 10.8 10x10 ShtMetl st3A st4 Peak AVF 465 389 0.096 669 10.4 10x10 ShtMetl st4A Peak AVF 354 352 0.096 637 9.4 8x10 ShtMetl st4 st4B Peak AVF 258 239 0.096 619 8.4 6x10 ShtMetl st4A st4C Peak AVF 119 65 0.096 608 6.0 0x0 ShtMetl st4B st5C Peak AVF 108 90 0.075 552 6.0 0x0 ShtMetl st5B st5B Peak AVF 228 241 0.074 578 8.6 6x10 ShtMetl st5A st5A Peak AVF 242 337 0.074 607 9.8 8x10 ShtMetl st5 st6A Peak AVF 217 135 0.086 650 8.0 6x8 ShtMetl st6 st6 Peak AVF 317 245 0.086 570 9.2 8x10 ShtMetl st3A st3A Peak AVF 643 686 0.074 588 12.7 12x14 ShtMetl st3 st3 Peak AVF 835 911 0.074 683 14.1 12x16 ShtMetl Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb1 0x 13000 1300 146.0 0.074 650 16.1 x18 16 ShMt 2024-Oct-03 17:52:25 Right-Suite® Universal 2024 24.0.02 RSU16998 Page 3 ... Grosbeak Place, Glenwood Springs, CO 81601.rup Calc = MJ8 Front Door faces: N 52 Grosbeak PlaceJob:Duct System Summary October 2nd 2024Date:AC 2 Master Suite Kenneth D. PuzinasBy: 52 Grosbeak PlacePlan:WebREPS, LLC 1880 82nd Avenue Suite # 203, Vero Beach, FL 32966 Phone: 800-810-3280 Fax: 888-971-2999 Email: manualj@webrepsusa.com Web: www.acductdesign.com License: CAC054709 Project Information Kenneth Garrett, Junior's LTDFor: 6372 S Benton Way, Littleton, CO 80123 Phone: 303 359 9671 Fax: N/A Email: kennygarr@gmail.com CoolingHeating External static pressure in H2O0.60in H2O0.60 Pressure losses in H2O0.24in H2O0.24 Available static pressure in H2O0.36in H2O0.36 Supply / return available pressure 0.258 / 0.102 in H2O in H2O0.258 / 0.102 Lowest friction rate in/100ft0.116in/100ft0.116 Actual air flow cfm753cfm753 Total effective length (TEL) ft310 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st1140.016.0ShMt0x06.00.165191164548hDEEP CRAWL SP st2A150.025.3ShMt0x06.00.147271365352hMASTER CRAWL SP st2B185.037.3ShMt0x07.00.116271365352hMASTER CRAWL SP-A st2B190.024.3ShMt0x04.00.120111180cP WC st2A160.024.3ShMt0x04.00.140154250cPANTRY st2130.022.5ShMt0x06.00.169122671998cPRIMARY BATH st1125.024.3ShMt0x06.00.173125642043cPRIMARY BEDROOM st1135.024.5ShMt0x06.00.162125642043cPRIMARY BEDROOM-A st2140.015.8ShMt0x04.00.166233382cPWIC st2B170.044.3ShMt0x07.00.1201731102832cSTUDY OFFICE st2B180.042.0ShMt0x05.00.11685521390cWIC / DRESSING Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st1 Peak AVF 245 269 0.162 646 7.7 10x6 ShtMetl st2 Peak AVF 508 484 0.116 610 10.4 12x10 ShtMetl st2A Peak AVF 438 339 0.116 631 9.8 10x10 ShtMetl st2 st2B Peak AVF 299 296 0.116 672 8.5 8x8 ShtMetl st2A 2024-Oct-03 17:52:25 Right-Suite® Universal 2024 24.0.02 RSU16998 Page 4 ... Grosbeak Place, Glenwood Springs, CO 81601.rup Calc = MJ8 Front Door faces: N Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb2 0x 7530 753 88.0 0.116 645 12.0 x12 14 ShMt